If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 11: | Line 11: | ||
| County: [[Cuyahoga_County,_Ohio|Cuyahoga]] | | County: [[Cuyahoga_County,_Ohio|Cuyahoga]] | ||
|- | |- | ||
− | | Municipality: Mayfield | + | | Municipality: [[Mayfield Village,_Cuyahoga_County,_Ohio|Mayfield Village]] |
|- | |- | ||
| Operator Name: [[BASS ENERGY CO INC]] | | Operator Name: [[BASS ENERGY CO INC]] | ||
Line 33: | Line 33: | ||
| Configuration: Vertical | | Configuration: Vertical | ||
|- | |- | ||
− | | Latitude: | + | | Latitude: <Latitude> |
|- | |- | ||
| Longitude: -81.42452150 | | Longitude: -81.42452150 |
Well ID: 34-035-22131 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.547710674,"lon":-81.4245215,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Cuyahoga | |
Municipality: Mayfield Village | |
Operator Name: BASS ENERGY CO INC | |
Well Pad ID: | |
Farm/Lease Name: PETERSON UNIT | |
License Status: Producing | |
License Date: 2009-09-09 | |
Spud Date: 2009-09-29 | |
Spud Drilling Contractor: H A D INC | |
Final Drill Date: 2009-10-07 | |
Well Total Depth: 3440 ft | |
Configuration: Vertical | |
Latitude: <Latitude> | |
Longitude: -81.42452150 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2009-09-09 | Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:9/9/2009, Expired Date:9/9/2010 6:00:00 AM, Drilling unit acres:21.55, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2009-10-07 | |
Completion Report Received | 2009-12-10 | |
Construction Permit Expires | 2010-09-09 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2010-02-18 | 3232 | 3254 | 47 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 70011 Gal | 40000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | BASS ENERGY CO INC | 98333 | 565 | 365 |
2011 | BASS ENERGY CO INC | 93850 | 284 | 0 |
2012 | BASS ENERGY CO INC | 71951 | 214 | 366 |
2013 | BASS ENERGY CO INC | 52432 | 154 | 365 |
2014 | BASS ENERGY CO INC | 39374 | 79 | 365 |
2015 | BASS ENERGY CO INC | 30192 | 162 | 365 |
2016 | BASS ENERGY CO INC | 25118 | 72 | 365 |
2017 | BASS ENERGY CO INC | 21838 | 94 | 365 |
2018 | BASS ENERGY CO INC | 19531 | 0 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | BASS ENERGY CO INC | Brine | 488 | 365 |
2011 | BASS ENERGY CO INC | Brine | 190 | |
2012 | BASS ENERGY CO INC | Brine | 166 | 366 |
2013 | BASS ENERGY CO INC | Brine | 116 | 365 |
2014 | BASS ENERGY CO INC | Brine | 185 | 365 |
2015 | BASS ENERGY CO INC | Brine | 115 | 365 |
2016 | BASS ENERGY CO INC | Brine | 60 | 365 |
2017 | BASS ENERGY CO INC | Brine | 114 | 365 |
2018 | BASS ENERGY CO INC | Brine | 120 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0274914659 | 2009-10-05 | Drill / Deepen / Reopen | No Violations | rig check drilling at 3000 on fluid. |
0451203920 | 2009-10-07 | Drill / Deepen / Reopen | No Violations | cementing 4.5 casing in. |
0626452153 | 2009-09-28 | Drill / Deepen / Reopen | No Violations | Trees cut company working in site grading topsoil. |
0935217306 | 2010-09-30 | Preliminary Restoration | No Violations | |
0971642212 | 2009-10-02 | Drill / Deepen / Reopen | No Violations | rig drilling cement from surface. |
1255450193 | 2009-09-30 | Drill / Deepen / Reopen | No Violations | surface cementing. |
1260205977 | 2009-10-20 | Drill / Deepen / Reopen | No Violations | Pits closed area graded. |
1270340781 | 2009-10-26 | Drill / Deepen / Reopen | No Violations | well service perforating the 4.5 casing.
No violation at time of inspection |
1409161504 | 2014-08-27 | UrbanProduction Wells | No Violations | I inspected this producing unit as part of routine inspection activity. The well was completed in 10/07/2009. The unit is producing and production reports are current. The well is located in a upscale suburban area with large lots, and densely wooded areas around the well and battery. The producing unit is accessed via an extension from the existing residential driveway. The access road is primarily gravel and slopes downward towards the battery. Elements of the well consist of a production wellhead with standard valve assembly and mechanical plunger-lift system and aboveground storage tank (AST) battery in separate board-on-board enclosures. The valve fittings, connections, and other production appurtenances appear to be well maintained and are free from signs of leakage or other problems. The battery is comprised of 1 steel 140-barrel production tank, 1 50-barrel poly brine tank, and separator unit. Spacing from well to battery, and spacing of elements within the battery meet regulations. The load-outs are bull-plugged. There is secondary containment at the battery and the interior areas are dry. I did not observe any signs or evidence of leakage, spills, or problems. Unit identification placards are present at both the battery and wellhead and are in good condition. I observed no issues or problems requiring attention at the time of my inspection. |
1610135766 | 2009-10-07 | Drill / Deepen / Reopen | No Violations | drilling 3200 no fluid loss |
For data sources see[9]