If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 11: | Line 11: | ||
| County: [[Hocking_County,_Ohio|Hocking]] | | County: [[Hocking_County,_Ohio|Hocking]] | ||
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[Falls Township,_Hocking_County,_Ohio|Falls Township]] |
|- | |- | ||
| Operator Name: [[LOGAN GAS INC]] | | Operator Name: [[LOGAN GAS INC]] |
Well ID: 34-073-22587 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.582883802,"lon":-82.32614928,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Hocking | |
Municipality: Falls Township | |
Operator Name: LOGAN GAS INC | |
Well Pad ID: | |
Farm/Lease Name: PARKIN JO & STARR LETHIA | |
License Status: Producing | |
License Date: 1993-12-09 | |
Spud Date: 1981-12-07 | |
Spud Drilling Contractor: BEVERLY DRLG | |
Final Drill Date: 1981-12-18 | |
Well Total Depth: 2980 ft | |
Configuration: Vertical | |
Latitude: 39.582883802 | |
Longitude: -82.32614928 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1981-10-30 | 488 DIAMOND OIL CO GeoDate 10/30/81 |
Oil and Gas | 1981-10-30 | Issued Date 10/30/81 Expired Date Acres 0020000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000 |
Original Spud | 1981-12-10 | |
Completed | 1981-12-18 | |
Reached Total Depth | 1981-12-18 | |
Completion Report Received | 1982-01-14 | |
Construction Permit Expires | 1982-04-28 | |
CO | 1992-04-03 | 4074 OIL ENTERPRISES GeoDate 10/30/81 |
Annular Disposal Well | 1993-12-09 | |
Revocation | 2009-05-04 | |
Change of Owner | 2010-02-18 | Operator changed from 4074, OIL ENTERPRISES to 8416, LOGAN GAS INC |
Last Compliance Report | 2014-03-06 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1998-01-13 | 2828 | 2854 | 21 |
2006-09-11 | 2832 | 2840 | 9 |
2006-09-11 | 2845 | 2854 | 1 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 0 | 45000 | AMOUNT OF FLUID USED - UNKNOWN - DID USE 165 GALLONS OF ACID | ||
ACID | 0 | 165 Gal | 45000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | DIAMOND OIL CO | 3000 | 837 | 300 |
1986 | DIAMOND OIL CO | 3550 | 683 | 260 |
1987 | DIAMOND OIL CO | 3400 | 690 | 156 |
1988 | DIAMOND OIL CO | 2321 | 452 | 140 |
1989 | DIAMOND OIL CO | 2181 | 392 | 140 |
1990 | DIAMOND OIL CO | 2494 | 380 | 195 |
1991 | DIAMOND OIL CO | 1020 | 209 | 60 |
1993 | OIL ENTERPRISES | 2450 | 408 | 365 |
1994 | OIL ENTERPRISES | 2095 | 467 | 365 |
1995 | OIL ENTERPRISES | 2275 | 399 | 365 |
1996 | OIL ENTERPRISES | 2669 | 464 | 365 |
1997 | OIL ENTERPRISES | 2086 | 304 | 365 |
1998 | OIL ENTERPRISES | 1943 | 347 | 365 |
1999 | OIL ENTERPRISES | 500 | 218 | 365 |
2000 | OIL ENTERPRISES | 445 | 223 | 365 |
2001 | OIL ENTERPRISES | 360 | 128 | 365 |
2002 | OIL ENTERPRISES | 189 | 0 | 365 |
2003 | OIL ENTERPRISES | 161 | 0 | 365 |
2004 | OIL ENTERPRISES | 137 | 0 | 365 |
2005 | OIL ENTERPRISES | 164 | 153 | 365 |
2006 | OIL ENTERPRISES | 17 | 485 | 365 |
2007 | OIL ENTERPRISES | 0 | 246 | 365 |
2008 | OIL ENTERPRISES | 0 | 267 | 365 |
2009 | OIL ENTERPRISES | 0 | 74 | 365 |
2010 | LOGAN GAS INC | 0 | 178 | 184 |
2011 | LOGAN GAS INC | 0 | 117 | 0 |
2012 | LOGAN GAS INC | 0 | 376 | 366 |
2013 | LOGAN GAS INC | 0 | 263 | 320 |
2014 | LOGAN GAS INC | 0 | 141 | 300 |
2015 | LOGAN GAS INC | 0 | 126 | 300 |
2016 | LOGAN GAS INC | 0 | 53 | 300 |
2017 | LOGAN GAS INC | 0 | 195 | 300 |
2018 | LOGAN GAS INC | 0 | 14 | 300 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | DIAMOND OIL CO | Brine | 900 | 300 |
1986 | DIAMOND OIL CO | Brine | 1100 | 260 |
1987 | DIAMOND OIL CO | Brine | 300 | 156 |
1988 | DIAMOND OIL CO | Brine | 150 | 140 |
1989 | DIAMOND OIL CO | Brine | 200 | 140 |
1990 | DIAMOND OIL CO | Brine | 350 | 195 |
1991 | DIAMOND OIL CO | Brine | 200 | 60 |
1993 | OIL ENTERPRISES | Brine | 470 | 365 |
1994 | OIL ENTERPRISES | Brine | 470 | 365 |
1995 | OIL ENTERPRISES | Brine | 470 | 365 |
1996 | OIL ENTERPRISES | Brine | 470 | 365 |
1997 | OIL ENTERPRISES | Brine | 470 | 365 |
1998 | OIL ENTERPRISES | Brine | 470 | 365 |
1999 | OIL ENTERPRISES | Brine | 470 | 365 |
2000 | OIL ENTERPRISES | Brine | 470 | 365 |
2001 | OIL ENTERPRISES | Brine | 350 | 365 |
2002 | OIL ENTERPRISES | Brine | 300 | 365 |
2003 | OIL ENTERPRISES | Brine | 300 | 365 |
2004 | OIL ENTERPRISES | Brine | 300 | 365 |
2005 | OIL ENTERPRISES | Brine | 300 | 365 |
2006 | OIL ENTERPRISES | Brine | 300 | 365 |
2007 | OIL ENTERPRISES | Brine | 210 | 365 |
2008 | OIL ENTERPRISES | Brine | 210 | 365 |
2009 | OIL ENTERPRISES | Brine | 100 | 365 |
2010 | LOGAN GAS INC | Brine | 260 | 184 |
2011 | LOGAN GAS INC | Brine | 320 | |
2012 | LOGAN GAS INC | Brine | 560 | 366 |
2013 | LOGAN GAS INC | Brine | 215 | 320 |
2014 | LOGAN GAS INC | Brine | 140 | 300 |
2015 | LOGAN GAS INC | Brine | 140 | 300 |
2016 | LOGAN GAS INC | Brine | 0 | 300 |
2017 | LOGAN GAS INC | Brine | 0 | 300 |
2018 | LOGAN GAS INC | Brine | 0 | 300 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0002872736 | 2009-05-20 | Annular Disposal | No Violations | An inspection was conducted to verify the status of Annular Disposal connection. It was noted that AD has been disconnected and is not being utilized. (2) 100 bbl tanks are a source for brine storage. At the time of the inspection, the knockout tank was found not connected. |
0044270325 | 2014-02-26 | Production Wells | No Violations | Compliance notice follow-up. The well has a legible identification, this satisfies the compliance notice. |
0096079345 | 2004-02-25 | Annular Disposal | No Violations | Follow-up on NOV, In-Compliance. |
0154737019 | 2011-02-02 | Annular Disposal | No Violations | FOLLOW UP TO NOV # 1296671350 Inspected by Andy Thomas. Identification tag faded on well head. Will need rewritten. Fitting on bottom of separator need repaired or replaced. Small leak starting to appear. Corrosion on bottom of knockout tank, and liquid underneath of it indicated that it may be leaking. Results of the high range quantab test revealed that the liquid under it was over 2000 ppm. Appears a fitting had been replaced or repaired on the bottom of production tank which allowed a small amount of oil to contaminate dike area. ID tag needs replaced, all producing leases shall be legibly identified in a conspicuous place on or near the well-head or the storage tank(s) as to owner, lease name, well number, permit number where available, county, and an emergency telephone number. Fitting on bottom of separator needs repaired/replaced. All surface equipment must be pressure rated to withstand operating pressures to which it is subjected. Knockoff tank needs repaired or replaced. All wells must be equipped so that no oil, gas or condensate is allowed to escape with the exception of gas flares. Clean up all oily material and dispose of in proper manner. At 3:20 PM spoke with Ray St. Clair via telephone and explained violations and what was needed to correct problem. He was already aware of the issues that the tank battery was having and had already bypassed knockout tank. |
0199065538 | 2011-02-02 | Annular Disposal | No Violations | FOLLOW UP TO NOV # 1296671350 Inspected by Andy Thomas. Identification tag faded on well head. Will need rewritten. Fitting on bottom of separator need repaired or replaced. Small leak starting to appear. Corrosion on bottom of knockout tank, and liquid underneath of it indicated that it may be leaking. Results of the high range quantab test revealed that the liquid under it was over 2000 ppm. Appears a fitting had been replaced or repaired on the bottom of production tank which allowed a small amount of oil to contaminate dike area. ID tag needs replaced, all producing leases shall be legibly identified in a conspicuous place on or near the well-head or the storage tank(s) as to owner, lease name, well number, permit number where available, county, and an emergency telephone number. Fitting on bottom of separator needs repaired/replaced. All surface equipment must be pressure rated to withstand operating pressures to which it is subjected. Knockoff tank needs repaired or replaced. All wells must be equipped so that no oil, gas or condensate is allowed to escape with the exception of gas flares. Clean up all oily material and dispose of in proper manner. At 3:20 PM spoke with Ray St. Clair via telephone and explained violations and what was needed to correct problem. He was already aware of the issues that the tank battery was having and had already bypassed knockout tank. |
0203131527 | 2010-10-07 | Annular Disposal | No Violations | An inspection revealed locations inside the earthen dike have been remediated. Also noted, the (2) 100 bbl tanks now contain fresh paint. No violations were noted. |
0818425852 | 2010-02-08 | Annular Disposal | No Violations | A follow-up inspection revealed new black plastic line from separator to 100 bbl tank. Gas is still being vented without use of flare. Note: snow cover at time of inspection. |
1009865562 | 2011-02-02 | Annular Disposal | No Violations | FOLLOW UP TO NOV # 199065538 FOLLOW UP TO NOV # 1296671350 Inspected by Andy Thomas. Identification tag faded on well head. Will need rewritten. Fitting on bottom of separator need repaired or replaced. Small leak starting to appear. Corrosion on bottom of knockout tank, and liquid underneath of it indicated that it may be leaking. Results of the high range quantab test revealed that the liquid under it was over 2000 ppm. Appears a fitting had been replaced or repaired on the bottom of production tank which allowed a small amount of oil to contaminate dike area. ID tag needs replaced, all producing leases shall be legibly identified in a conspicuous place on or near the well-head or the storage tank(s) as to owner, lease name, well number, permit number where available, county, and an emergency telephone number. Fitting on bottom of separator needs repaired/replaced. All surface equipment must be pressure rated to withstand operating pressures to which it is subjected. Knockoff tank needs repaired or replaced. All wells must be equipped so that no oil, gas or condensate is allowed to escape with the exception of gas flares. Clean up all oily material and dispose of in proper manner. At 3:20 PM spoke with Ray St. Clair via telephone and explained violations and what was needed to correct problem. He was already aware of the issues that the tank battery was having and had already bypassed knockout tank. |
1022196298 | 2004-01-30 | Annular Disposal | Violations Noted | An inspection of the well revealed the wrong Permit # at the well. |
1206622232 | 2008-03-05 | Production Wells | No Violations | No violations were noted. |
1266867243 | 2010-02-01 | Annular Disposal | Violations Noted | An inspection revealed that gas is being vented from the well without the use of a flare. Inside the earthen dike at tank battery, pollution and contamination was observed at two locations. The first observed location was a fitting leak from a separator. The second location was underneath a knockout (standing) containing corrosion and found leaking at time of inspection. High Range Quantabs placed in fluid showed 10 units. A 1 line black plastic line was observed connected to bottom of knockout and no connection on opposite end of line. At conclusion of inspection, the well owner, Oil Enterprises, was notified in person of inspection results. The well owner states violations will be taken care of tomorrow. |
1267214964 | 2010-02-02 | Annular Disposal | No Violations | A follow-up inspection revealed non-compliance. |
1267469988 | 2010-02-04 | Annular Disposal | No Violations | A follow-up inspection revealed non-compliance. The knock-out tank is no longer leaking. P&C and venting gas still exists. |
1296671350 | 2011-02-02 | Annular Disposal | Violations Noted | Inspected by Andy Thomas. Identification tag faded on well head. Will need rewritten. Fitting on bottom of separator need repaired or replaced. Small leak starting to appear. Corrosion on bottom of knockout tank, and liquid underneath of it indicated that it may be leaking. Results of the high range quantab test revealed that the liquid under it was over 2000 ppm. Appears a fitting had been replaced or repaired on the bottom of production tank which allowed a small amount of oil to contaminate dike area. ID tag needs replaced, all producing leases shall be legibly identified in a conspicuous place on or near the well-head or the storage tank(s) as to owner, lease name, well number, permit number where available, county, and an emergency telephone number. Fitting on bottom of separator needs repaired/replaced. All surface equipment must be pressure rated to withstand operating pressures to which it is subjected. Knockoff tank needs repaired or replaced. All wells must be equipped so that no oil, gas or condensate is allowed to escape with the exception of gas flares. Clean up all oily material and dispose of in proper manner. At 3:20 PM spoke with Ray St. Clair via telephone and explained violations and what was needed to correct problem. He was already aware of the issues that the tank battery was having and had already bypassed knockout tank. |
1326632992 | 2010-03-01 | Annular Disposal | No Violations | A follow-up inspection revealed compliance. No gas was being vented at time of inspection. It was also noted that well ownership has now changed to Logan Gas Inc. Note: snow cover at time of inspection. |
1401847342 | 2019-02-05 | Production Wells | No Violations | My inspection revealed that the well was equipped with a pumping unit and motor. The tank battery consists of (2) 100 barrel tanks, (1) knockout tank, and a separator inside an earthen dike. I observed partial identification at the well. I contacted pumper Larry Howdyshell at 9:55 AM on 2/7/2019 and advised him that identification needs posted. Time of inspection: 2:10 PM. Weather: 52 degrees F, Overcast |
1572614357 | 2013-11-26 | Production Wells | No Violations | Compliance notice follow up. The well has a legible identification, this satisfies the compliance notice. |
1948556564 | 2004-03-03 | Annular Disposal | No Violations | AD test on well, well passed test. |
2057990010 | 2005-03-28 | Annular Disposal | No Violations | No violations. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1022196298 | US-OH-100469 | 2004-01-30 | Failure to legibly identify well | |
1022196298 | US-OH-100470 | 2004-01-30 | No SPCC dike/or failure to keep dike free of water or oil | |
1266867243 | US-OH-107152 | 2010-02-22 | Well operation causing pollution and contamination | |
1266867243 | US-OH-107153 | 2010-02-22 | Equipment pressure rated below operating pressure | |
1266867243 | US-OH-107154 | 2010-02-22 | Unlawful venting or flaring of gas | |
1296671350 | US-OH-108339 | 2011-02-02 | Well operation causing pollution and contamination | |
1296671350 | US-OH-108340 | 2011-02-02 | Failure to legibly identify well | |
1296671350 | US-OH-108341 | 2011-02-02 | Equipment pressure rated below operating pressure |
For data sources see[9]