| County: [[Cuyahoga_County,_Ohio|Cuyahoga]] | | County: [[Cuyahoga_County,_Ohio|Cuyahoga]] | ||
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[Cuyahoga Heights Village,_Cuyahoga_County,_Ohio|Cuyahoga Heights Village]] |
|- | |- | ||
| Operator Name: [[DUCK CREEK ENERGY INC]] | | Operator Name: [[DUCK CREEK ENERGY INC]] | ||
Line 33: | Line 33: | ||
| Configuration: Vertical | | Configuration: Vertical | ||
|- | |- | ||
− | | Latitude: | + | | Latitude: <Latitude> |
|- | |- | ||
| Longitude: -81.68171330 | | Longitude: -81.68171330 |
Well ID: 34-035-21775 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.444291095,"lon":-81.6817133,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Cuyahoga | |
Municipality: Cuyahoga Heights Village | |
Operator Name: DUCK CREEK ENERGY INC | |
Well Pad ID: | |
Farm/Lease Name: 550 HARVARD UNIT | |
License Status: Producing | |
License Date: 2003-04-04 | |
Spud Date: 2003-04-29 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2003-05-04 | |
Well Total Depth: 2878 ft | |
Configuration: Vertical | |
Latitude: <Latitude> | |
Longitude: -81.68171330 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2003-04-04 | Proposed Formations:CLINTON, Issued Date:4/4/2003, Expired Date:4/3/2004 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 2003-04-29 | RBDMS Rec |
Completed | 2003-05-04 | RBDMS Rec |
Reached Total Depth | 2003-05-04 | RBDMS Rec |
Correction to Well | 2003-07-03 | TOWNSHIP CORRECTED TO "INDEPENDENCE". |
Completion Report Received | 2003-07-17 | RBDMS Rec |
Construction Permit Expires | 2004-04-03 | RBDMS Rec |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2003-08-29 | 2743 | 2797 | 36 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 59000 Gal | 0 | 500 GALLONS HCL ACID |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2003 | DUCK CREEK ENERGY INC | 0 | 0 | 0 |
2004 | DUCK CREEK ENERGY INC | 10488 | 119 | 310 |
2005 | DUCK CREEK ENERGY INC | 8382 | 66 | 365 |
2006 | DUCK CREEK ENERGY INC | 2969 | 0 | 365 |
2007 | DUCK CREEK ENERGY INC | 500 | 0 | 365 |
2008 | DUCK CREEK ENERGY INC | 2557 | 106 | 365 |
2009 | DUCK CREEK ENERGY INC | 1881 | 0 | 365 |
2010 | DUCK CREEK ENERGY INC | 1421 | 0 | 365 |
2011 | DUCK CREEK ENERGY INC | 1320 | 0 | 365 |
2012 | DUCK CREEK ENERGY INC | 1831 | 0 | 366 |
2013 | DUCK CREEK ENERGY INC | 1559 | 0 | 365 |
2014 | DUCK CREEK ENERGY INC | 1514 | 83 | 365 |
2015 | DUCK CREEK ENERGY INC | 362 | 0 | 365 |
2016 | DUCK CREEK ENERGY INC | 0 | 0 | 365 |
2017 | DUCK CREEK ENERGY INC | 0 | 0 | 365 |
2018 | DUCK CREEK ENERGY INC | 0 | 0 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2003 | DUCK CREEK ENERGY INC | Brine | 1830 | 0 |
2004 | DUCK CREEK ENERGY INC | Brine | 1695 | 310 |
2005 | DUCK CREEK ENERGY INC | Brine | 948 | 365 |
2006 | DUCK CREEK ENERGY INC | Brine | 297 | 365 |
2007 | DUCK CREEK ENERGY INC | Brine | 1789 | 365 |
2008 | DUCK CREEK ENERGY INC | Brine | 1390 | 365 |
2009 | DUCK CREEK ENERGY INC | Brine | 1357 | 365 |
2010 | DUCK CREEK ENERGY INC | Brine | 995 | 365 |
2011 | DUCK CREEK ENERGY INC | Brine | 1426 | 365 |
2012 | DUCK CREEK ENERGY INC | Brine | 1167 | 366 |
2013 | DUCK CREEK ENERGY INC | Brine | 1119 | 365 |
2014 | DUCK CREEK ENERGY INC | Brine | 946 | 365 |
2015 | DUCK CREEK ENERGY INC | Brine | 173 | 365 |
2016 | DUCK CREEK ENERGY INC | Brine | 0 | 365 |
2017 | DUCK CREEK ENERGY INC | Brine | 0 | 365 |
2018 | DUCK CREEK ENERGY INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
1371843126 | 2013-06-21 | UrbanProduction Wells | No Violations | The producing unit consists of a production wellhead and an above-ground storage tank (AST) battery. The battery is comprised of 1 210-barrel and 1 100-barrel steel AST, and mechanical separator. ID is present. Secondary containment is present at the battery. The wellhead is fitted with a pump jack system and is producing. I did not observe any leaks or problems. |
1592657966 | 2017-09-14 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery in separate enclosures, both located on a parcel occupied by a church. The enclosure gates were locked and secure. The load-line valves were secure. Tank lids were closed and secure. The secondary containment was intact and dry. I walked the areas surrounding the well and battery and found no signs of impacts or problems. I had noted during a previous inspection that the 2-inch cross-over line at the battery was corroded. The condition remained at this inspection, although there was no sign of leakage or loss of integrity. I notified Dave Mansbury with Duck Creek about the potential problem. |
2135577048 | 2016-11-16 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following elements: a wellhead with pump jack system and associated tank battery, both located within the confines of a materials supply and storage operation. Fittings and connections at the wellhead were secure and free from signs of leakage or problems. Tank lids were closed and secure. Secondary containment was intact and free from signs of spills or leakage. Load lines were plugged and secure. I noted the following: the 2-inch cross-over line between the production tank and brine tank was corroded and should be replaced before it fails. I contacted Dave Mansbury with Duck Creek Energy and advised about the need for maintenance at the cross-over lines. |
For data sources see[9]