X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-167-26070"

m
m
Line 11: Line 11:
 
| County: [[Washington_County,_Ohio|Washington]]
 
| County: [[Washington_County,_Ohio|Washington]]
 
|-
 
|-
| Municipality: [[Liberty_Township,_Washington_County,_Ohio|Liberty Township]]
+
| Municipality: [[Liberty Township,_Washington_County,_Ohio|Liberty Township]]
 
|-
 
|-
 
| Operator Name: [[STEVENS OIL & GAS LLC]]
 
| Operator Name: [[STEVENS OIL & GAS LLC]]

Revision as of 20:01, 15 August 2019

Well Details

Well ID: 34-167-26070
Loading map...
Country: United States
State: Ohio
County: Washington
Municipality: Liberty Township
Operator Name: STEVENS OIL & GAS LLC
Well Pad ID:
Farm/Lease Name: LANTZ JULIA
License Status: Producing
License Date: 1980-10-30
Spud Date: 1980-12-18
Spud Drilling Contractor:
Final Drill Date: 1980-12-23
Well Total Depth: 3993 ft
Configuration: Vertical
Latitude: 39.544784387
Longitude: -81.33367560

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1980-10-30 2412 CITATION ENERGY CO GeoDate 10/30/80
Oil and Gas 1980-10-30 Issued Date 10/30/80 Expired Date Acres 0020000 Tool Type RTAF Proposed Formation OHIO SHALE Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1980-12-18
Completed 1980-12-23
Reached Total Depth 1980-12-23
Completion Report Received 1981-05-21
Change of Owner 2016-08-31 Operator changed from 2412, CITATION ENERGY CO to 6386, STEVENS OIL & GAS LLC
Record Last Modified 2016-08-31

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3524 3528 5
2006-09-11 3586 3590 5

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 690 Mscf 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1993 CITATION ENERGY COMPANY 1665 85 365
1995 CITATION ENERGY COMPANY 1855 85 365
1996 CITATION ENERGY COMPANY 1416 80 365
1999 CITATION ENERGY COMPANY 1137 75 365
2000 CITATION ENERGY COMPANY 1157 0 365
2001 CITATION ENERGY COMPANY 465 60 365
2002 CITATION ENERGY COMPANY 548 0 365
2003 CITATION ENERGY COMPANY 967 75 365
2004 CITATION ENERGY COMPANY 1024 50 365
2005 CITATION ENERGY COMPANY 988 25 365
2006 CITATION ENERGY COMPANY 537 90 365
2008 CITATION ENERGY COMPANY 385 80 365
2009 CITATION ENERGY COMPANY 682 60 305
2012 CITATION ENERGY COMPANY 150 190 275
2014 CITATION ENERGY COMPANY 320 142 185
2015 CITATION ENERGY COMPANY 220 70 180
2016 CITATION ENERGY COMPANY 135 0 180
2017 STEVENS OIL & GAS LLC 1383 46 365
2018 STEVENS OIL & GAS LLC 9 23 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1993 CITATION ENERGY COMPANY Brine 0 365
1995 CITATION ENERGY COMPANY Brine 0 365
1996 CITATION ENERGY COMPANY Brine 0 365
1999 CITATION ENERGY COMPANY Brine 0 365
2000 CITATION ENERGY COMPANY Brine 0 365
2001 CITATION ENERGY COMPANY Brine 0 365
2002 CITATION ENERGY COMPANY Brine 0 365
2003 CITATION ENERGY COMPANY Brine 0 365
2004 CITATION ENERGY COMPANY Brine 0 365
2005 CITATION ENERGY COMPANY Brine 0 365
2006 CITATION ENERGY COMPANY Brine 0 365
2008 CITATION ENERGY COMPANY Brine 0 365
2009 CITATION ENERGY COMPANY Brine 0 305
2012 CITATION ENERGY COMPANY Brine 20 275
2014 CITATION ENERGY COMPANY Brine 0 185
2015 CITATION ENERGY COMPANY Brine 0 180
2016 STEVENS OIL & GAS LLC Brine 0 365
2017 STEVENS OIL & GAS LLC Brine 0 365
2018 STEVENS OIL & GAS LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0790878492 2019-06-04 Production Wells No Violations I was on location today to do a field inspection on this well. The well appears to be capable of production at this time. The well has a pumping unit on it with rods and 2 inch diameter tubing in it. The valves are open from the well to the tank pad. There are no violations at this time.
1408785713 2009-01-13 Production Wells No Violations Inspection this day found well producing, good IDs at tank, need more dike, not sure where meter is but valves open.
1479222047 2016-11-15 Production Wells No Violations The purpose of my inspection today is a status check on a producing well. During my inspection the well was equipped with 8.625 inch diameter surface casing, 4.5 inch diameter production casing, 2.375 inch diameter tubing, rods, and a pumping unit. The valves on the tubing and production casing are opened. There is a 1 inch diameter domestic gas line attached to the production casing with a Little Joe regulator and a valve in the opened position. The production equipment consists of one 100 barrel tank and a vertical separator. The identification is located on the 100 barrel tank.
1826784892 2004-03-04 Production Wells No Violations Inspection this day found no violations, well with jack producing, tank area clean, dry, good dike, good IDs

For data sources see[9]

References