Revision as of 08:12, 15 August 2019

Well Details

Well ID: 34-129-20202
Loading map...
Country: United States
State: Ohio
County: Pickaway
Municipality: Jackson Township
Operator Name: HOUGHTON INVESTMENTS LLC
Well Pad ID:
Farm/Lease Name: GIBSON H & A
License Status: Final Restoration
License Date: 2014-06-04
Spud Date: 2004-04-06
Spud Drilling Contractor: L & S DRLG
Final Drill Date: 2004-04-13
Well Total Depth: 2430 ft
Configuration: Vertical
Latitude: 39.610158368
Longitude: -83.06321564

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2004-03-08 Proposed Formations:TREMPEALEAU, Issued Date:3/8/2004, Expired Date:3/8/2005 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2004-04-06 RBDMS Rec
Completed 2004-04-13 RBDMS Rec
Reached Total Depth 2004-04-13 RBDMS Rec
Change of Owner 2004-07-22 Operator changed from 7077, D T ATHA INC to 6227, HOUGHTON INVESTMENTS, L.L.C.
Completion Report Received 2004-07-22 RBDMS Rec
APP 2014-06-04 Proposed Formations:TREMPEALEAU, Issued Date:6/4/2014, Expired Date:6/3/2016 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2014-06-16 RBDMS Rec
Construction Permit Expires 2016-06-03 RBDMS Rec
Record Last Modified 2018-11-20 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2004-09-28 2368 2372 16

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 500 Gal 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2004 HOUGHTON INVESTMENTS LLC 0 830 365
2005 HOUGHTON INVESTMENTS LLC 0 958 365
2006 HOUGHTON INVESTMENTS LLC 0 517 365
2007 HOUGHTON INVESTMENTS LLC 0 428 365
2008 HOUGHTON INVESTMENTS LLC 0 214 365
2009 HOUGHTON INVESTMENTS LLC 0 209 365
2010 HOUGHTON INVESTMENTS LLC 0 285 365
2011 HOUGHTON INVESTMENTS LLC 0 134 365
2012 HOUGHTON INVESTMENTS LLC 0 188 366
2013 HOUGHTON INVESTMENTS LLC 0 185 365
2014 HOUGHTON INVESTMENTS LLC 0 0 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2004 HOUGHTON INVESTMENTS LLC Brine 2484 365
2005 HOUGHTON INVESTMENTS LLC Brine 42 365
2006 HOUGHTON INVESTMENTS LLC Brine 304 365
2007 HOUGHTON INVESTMENTS LLC Brine 0 365
2008 HOUGHTON INVESTMENTS LLC Brine 0 365
2009 HOUGHTON INVESTMENTS LLC Brine 0 365
2010 HOUGHTON INVESTMENTS LLC Brine 0 365
2011 HOUGHTON INVESTMENTS LLC Brine 20 365
2012 HOUGHTON INVESTMENTS LLC Brine 0 366
2013 HOUGHTON INVESTMENTS LLC Brine 0 365
2014 HOUGHTON INVESTMENTS LLC Brine 65 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0114424080 2018-11-09 Final Restoration No Violations My inspection revealed the well was plugged on 6.16.14. I walked to the coordinates listed for this well and found no evidence of a well. The area were the well was located is a agriculture field. Final restoration is passed.
0178733289 2004-07-29 Preliminary Restoration No Violations Joint inspection with Jeff Fry.

- Operator has well in production, 2 - 210 barrel tanks and 1 - 100 barrel water tank. - Operator is pumping water to McCloud # 1 for disposal. Water meter reading 200749

0318950419 2006-01-10 Production Wells No Violations - Pump unit not operating while on site, ID on tanks.

- Water meter reading 307348 gallons = 7317 barrels - Weather Cloudy temp 30s

0474837620 2009-04-01 Production Wells No Violations - ID on tank, pump jack not operating while on site.

- Notice that production line has been repaired, band clamp around pipeline. Operator is in the process of cleaning and removing soil.

0825888289 2005-04-05 Production Wells No Violations Pump unit operating while on site, tank area clean and ID in place.

Water meter reading 305330 gal. = 7269 barrels.

1107189784 2005-01-26 Production Wells Violations Noted - Well not operating while on site, notice oil leaking to surface from production pipe between pump unit and tank battery. Notify Tom Atha and shut power off to pump unit area of oil is about 10ft X 20ft.

- Water reading from meter 305330 gals = 7269 barrels

1118237701 2005-06-07 Production Wells No Violations - Pump unit operating while on site, ID on tanks, area clean.

- Water meter reading 305877 gallons = 7282 barrels 13 barrels since last reading in April 2005.

1157739821 2006-03-08 Production Wells No Violations - Pump unit not operating while on site. ID on tank.

- Well and tank area clean and well maintained, area between well and tanks has had topsoil removed, this area is where production line broke last year. - Water meter not working, has same reading that was taken at last inspection. - Weather Overcast light rain temp 40s

1353147595 2009-06-10 Production Wells No Violations - ID on tank pump jack not operating while on site.
1366181508 2005-02-02 Production Wells Violations Noted Follow up inspection to NOV issued 1/26/2005. Operator has lay temporary production line from pump unit to tanks, operator has removed soil that was saturated with oil.
1377184369 2013-08-22 Production Wells No Violations - Pump unit not operating while on site. ID on Tank.
 1- 210 steel tank and 1-100 steel tank
Area clean and free of debris.
1402927455 2014-06-16 Plug / Plug Back No Violations - On site for plugging well, tubing and rods has been removed prior to arriving on site today.

- Berry Well Service doing service work, Formation Cementing Co. cement contactor. - 1st plug set at 2430 to 2130 - - - - Pull last 4 joints of casing and top off with cement to surface.

1441016795 2008-09-10 Production Wells No Violations - Pump unit operating while on site. ID on tanks.
1710793945 2004-10-06 Production Wells No Violations well not operating while on site, area around well and tank clean and free of water.

Water meter reading 294298 gal = 7007 barrels

1836097590 2008-06-11 Production Wells No Violations - ID on tank, pump unit operating while on site, area around well and tanks clean.
1965846471 2011-04-21 Production Wells No Violations - ID on tank, Pump jack not operating while on site. No Violations
1987175469 2009-01-06 Production Wells No Violations - Pump Jack not operating while on site. ID on Tank. Dike area free of water.

- Weather light freezing rain, Temp high 20s

2098154115 2005-10-04 Production Wells No Violations - Pump unit not operating while on site.

- Water meter reading 306977 gallons = 7,308 barrels

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1107189784 US-OH-102648 2005-01-31 Well operation causing pollution and contamination
1366181508 US-OH-110763 2005-01-31 Well operation causing pollution and contamination

For data sources see[9]

References