If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 297: | Line 297: | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
!scope="col" | Period | !scope="col" | Period | ||
+ | !scope="col" | Operator | ||
!scope="col" | Waste Type | !scope="col" | Waste Type | ||
!scope="col" | Quantity | !scope="col" | Quantity | ||
Line 302: | Line 303: | ||
!scope="col" | Waste Facility ID | !scope="col" | Waste Facility ID | ||
|- | |- | ||
− | | 2014 | + | | 2014 |
+ | | [[EQT PROD CO]] | ||
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 1,234.81 Tons | | style="text-align: right;" | 1,234.81 Tons | ||
Line 308: | Line 310: | ||
| 101397 | | 101397 | ||
|- | |- | ||
− | | 2014 | + | | 2014 |
+ | | [[EQT PROD CO]] | ||
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 230.00 Bbl |
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
− | | | + | | 2015 |
− | | | + | | [[EQT PROD CO]] |
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 510.00 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-007-21847 | ||
+ | |- | ||
+ | | 2015 | ||
+ | | [[EQT PROD CO]] | ||
+ | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 130.00 Bbl | | style="text-align: right;" | 130.00 Bbl | ||
− | | | + | | INJECTION DISPOSAL WELL |
− | + | | 34-167-23862 | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |- | ||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | 2, | + | | style="text-align: right;" | 2,412.00 Bbl |
| CENT WASTE TRT FAC NPDES DISCHARGE | | CENT WASTE TRT FAC NPDES DISCHARGE | ||
| EPA ID: 748-163 | | EPA ID: 748-163 | ||
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 480.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-133-20525 |
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 130.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-155-21438 |
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 193.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-007-23262 |
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 100.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-031-27241 |
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 200.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-157-25511 |
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 200.00 Bbl |
− | | | + | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) |
− | | | + | | WMGR123 |
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 100.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-031-27178 |
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 230.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-155-21893 |
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 28,466.00 Bbl |
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
− | | 2015 | + | | 2015 |
− | | | + | | [[EQT PROD CO]] |
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 260.00 Bbl | | style="text-align: right;" | 260.00 Bbl | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-155-22403 |
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 200.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-059-24202 |
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 877.00 Bbl |
− | | | + | | CENTRALIZED TREATMENT PLANT FOR RECYCLE |
− | | | + | | WMGR123NW011 |
|- | |- | ||
− | | 2015 | + | | 2015 |
− | | | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Fracing Fluid Waste (in Barrels) |
− | | | + | | style="text-align: right;" | 3,221.00 Bbl |
− | | | + | | REUSE OTHER THAN ROAD SPREADING |
+ | | | ||
|- | |- | ||
− | | 2015 | + | | 2015 |
− | | | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Fracturing Fluid Waste (in Tons) |
− | | | + | | style="text-align: right;" | 96.41 Tons |
− | | | + | | LANDFILL |
+ | | 101397 | ||
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 650.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-155-23223 |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 100.00 Bbl | | style="text-align: right;" | 100.00 Bbl | ||
Line 464: | Line 450: | ||
| 34-119-28780 | | 34-119-28780 | ||
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 300.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-007-24355 |
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 394.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-007-2-3097 |
|- | |- | ||
− | | 2015 | + | | 2015 |
− | | | + | | [[EQT PROD CO]] |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 130.00 Bbl | | style="text-align: right;" | 130.00 Bbl | ||
Line 494: | Line 471: | ||
| 34-155-23795 | | 34-155-23795 | ||
|- | |- | ||
− | | 2015 | + | | 2015 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 90.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-031-27177 |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | 2016 | + | | 2016 |
− | | | + | | [[EQT PROD CO]] |
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 6,820.00 Bbl | | style="text-align: right;" | 6,820.00 Bbl | ||
Line 530: | Line 485: | ||
| WMGR123NW005 | | WMGR123NW005 | ||
|- | |- | ||
− | | 2016 | + | | 2016 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 7,369.00 Bbl |
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
− | | | + | | 2016 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 4,270.00 Bbl |
− | | | + | | CENTRALIZED TREATMENT PLANT FOR RECYCLE |
| WMGR123NW011 | | WMGR123NW011 | ||
|- | |- | ||
− | | 2017 | + | | 2017 |
− | | | + | | [[EQT PROD CO]] |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 10.00 Bbl | | style="text-align: right;" | 10.00 Bbl | ||
Line 572: | Line 506: | ||
| WMGR123NW011 | | WMGR123NW011 | ||
|- | |- | ||
− | | 2017 | + | | 2017 |
− | | | + | | [[EQT PROD CO]] |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 7,778.00 Bbl |
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123NW011 | | WMGR123NW011 | ||
|- | |- | ||
− | | 2017 | + | | 2017 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 1,098.00 Bbl | | style="text-align: right;" | 1,098.00 Bbl | ||
Line 596: | Line 520: | ||
| | | | ||
|- | |- | ||
− | | 2017 | + | | 2017 |
− | | | + | | [[EQT PROD CO]] |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 137.00 Bbl | | style="text-align: right;" | 137.00 Bbl | ||
Line 644: | Line 527: | ||
| WMGR123NC010 | | WMGR123NC010 | ||
|- | |- | ||
− | | 2017 | + | | 2017 |
− | | | + | | [[EQT PROD CO]] |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 1,094.00 Bbl |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
− | | 2018 | + | | 2018 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 84.07 Bbl |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123SW019 | | WMGR123SW019 | ||
|- | |- | ||
− | | 2018 | + | | 2018 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 252.32 Bbl |
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
− | | 2018 | + | | 2018 |
− | | | + | | [[EQT PROD CO]] |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 8.80 Bbl | | style="text-align: right;" | 8.80 Bbl | ||
Line 770: | Line 555: | ||
| | | | ||
|- | |- | ||
− | | 2018 | + | | 2018 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 1,307.00 Bbl |
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
− | | | + | | WMGR123SW005 |
|- | |- | ||
− | | 2018 | + | | 2018 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 24.40 Bbl |
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
− | | | + | | WMGR123NC010 |
|- | |- | ||
− | | 2018 | + | | 2018 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 452.81 Bbl |
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
− | | | + | | WMGR123NW005 |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | 2018 | + | | 2018 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 175.53 Bbl |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123NW009 | | WMGR123NW009 | ||
|- | |- | ||
− | | 2018 | + | | 2018 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 4,600.24 Bbl |
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123NW011 | | WMGR123NW011 | ||
|- | |- | ||
− | | | + | | 2019 |
+ | | [[EQT PROD CO]] | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 14.39 Bbl |
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | + | | 2019 | |
− | + | | [[EQT PROD CO]] | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | 2019 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 135.87 Bbl | | style="text-align: right;" | 135.87 Bbl | ||
Line 854: | Line 604: | ||
| WMGR123SW019 | | WMGR123SW019 | ||
|- | |- | ||
− | | 2019 | + | | 2019 |
− | | | + | | [[EQT PROD CO]] |
− | |||
− | |||
− | |||
− | |||
− | |||
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 18.57 Bbl | | style="text-align: right;" | 18.57 Bbl | ||
Line 866: | Line 611: | ||
| | | | ||
|- | |- | ||
− | | 2019 | + | | 2019 |
− | | | + | | [[EQT PROD CO]] |
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 966.29 Bbl |
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | |
Well ID: 37-065-27040 | Your browser is not compatible with Google Maps v3.
|
Country: United States | |
State: Pennsylvania | |
County: Jefferson | |
Municipality: Washington Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 150231 | |
Farm/Lease Name: HORIZON 591667 | |
License Status: Active | |
Spud Date: 2014-01-22 | |
Permit Date: 2013-09-23 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.215147 | |
Longitude: -78.812731 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2015-05-18 | 2015-05-26 | 6994.72 | 12,517,100.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | LSG-100 | C and J Energy Services | Gelling agent | Proprietary non-hazardous polymers | Proprietary | 60 | 0.00133922 | 1571.98 |
Solvent naphtha | 64742-47-8 | 65 | 0.00145082 | 1702.98 | ||||
OB-2 | C and J Energy Services | Gel Breaker | Sillica, crystalline quartz | 7631-86-9 | 30 | 0.00000588 | 6.9 | |
Ammonium Persulfate | 7727-54-0 | 100 | 0.00001959 | 23 | ||||
WFR-12W | C and J Energy Services | Friction reducer | Anionic water-soluble polymer | Proprietary | 100 | 0.078282 | 91887.7 | |
MC MX 437-5 | Multi-Chem | Calcium nitrate solution | Calcium nitrate | 10124-37-5 | 60 | 0.0567035 | 66558.8 | |
Water | C and J Energy Services | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 88.9886 | 104,455,000.0 | |
Super TSC 2 LT | C and J Energy Services | Scale control | Bis(hexamethylene triaminepenta methylenephosphonic acid) | Proprietary | 10 | 0.00136211 | 1598.85 | |
Hydrochloric Acid (15%) | C and J Energy Services | Acidizing | Hydrochloric Acid | 7647-01-0 | 15 | 0.0256737 | 30135.9 | |
Sand (Proppant) | C and J Energy Services | Proppant | Silica Substrate | 14808-60-7 | 100 | 10.6408 | 12,490,200.0 | |
Super TSC LT | C and J Energy Services | Scale control | Proprietary non-hazardous materials | Proprietary | 100 | 0.0105071 | 12333.2 | |
AI-2 | C and J Energy Services | Acid Inhibitor | Benzyl Chloride-Quaternized | 72480-70-7 | 10 | 0.00003167 | 37.177 | |
Ethoxylated Nonylphenol | 68412-54-4 | 13 | 0.00004117 | 48.33 | ||||
Propargyl Alcohol | 107-19-7 | 40 | 0.000126689 | 148.708 | ||||
Isopropyl Alcohol | 67-63-0 | 40 | 0.000126689 | 148.708 | ||||
Glycol Ethers | 111-76-2 | 40 | 0.000126689 | 148.708 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | EQT PROD CO | 284,010.00 | 164 | 0.00 | 0 | 0.00 | 0 |
2016 | EQT PROD CO | 488,337.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | EQT PROD CO | 369,914.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | EQT PROD CO | 373,541.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2019 | EQT PROD CO | 73,820.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2014 | EQT PROD CO | Drill Cuttings (in Tons) | 1,234.81 Tons | LANDFILL | 101397 |
2014 | EQT PROD CO | Fracing Fluid Waste (in Barrels) | 230.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 510.00 Bbl | INJECTION DISPOSAL WELL | 34-007-21847 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 130.00 Bbl | INJECTION DISPOSAL WELL | 34-167-23862 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 2,412.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | EPA ID: 748-163 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 480.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20525 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 130.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 193.00 Bbl | INJECTION DISPOSAL WELL | 34-007-23262 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 100.00 Bbl | INJECTION DISPOSAL WELL | 34-031-27241 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 200.00 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 200.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 100.00 Bbl | INJECTION DISPOSAL WELL | 34-031-27178 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 230.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 28,466.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 260.00 Bbl | INJECTION DISPOSAL WELL | 34-155-22403 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 200.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 877.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2015 | EQT PROD CO | Fracing Fluid Waste (in Barrels) | 3,221.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EQT PROD CO | Fracturing Fluid Waste (in Tons) | 96.41 Tons | LANDFILL | 101397 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 650.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 100.00 Bbl | INJECTION DISPOSAL WELL | 34-119-28780 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 300.00 Bbl | INJECTION DISPOSAL WELL | 34-007-24355 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 394.00 Bbl | INJECTION DISPOSAL WELL | 34-007-2-3097 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 130.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2015 | EQT PROD CO | Produced Fluid (in Barrels) | 90.00 Bbl | INJECTION DISPOSAL WELL | 34-031-27177 |
2016 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 6,820.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2016 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 7,369.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 4,270.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2017 | EQT PROD CO | Other Oil & Gas Wastes (in Barrels) RWC 899 | 10.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 7,778.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 1,098.00 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2017 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 137.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 1,094.00 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 84.07 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 252.32 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 8.80 Bbl | RESIDUAL WASTE PROCESSING FACILITY | |
2018 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 1,307.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 24.40 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 452.81 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2018 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 175.53 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2018 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 4,600.24 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 14.39 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 135.87 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2019 | EQT PROD CO | Other Oil & Gas Wastes (in Barrels) RWC 899 | 18.57 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid (in Barrels) RWC 802 | 966.29 Bbl | REUSE (AT WELL PAD) |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2245676 | Primary Facility | 2014-02-12 | Drilling/Alteration | No Violations Noted | |
2247773 | Primary Facility | 2014-02-20 | Drilling/Alteration | No Violations Noted | |
2259387 | Primary Facility | 2014-04-03 | Routine/Complete Inspection | No Violations Noted | |
2286866 | Primary Facility | 2014-06-26 | Drilling/Alteration | No Violations Noted | |
2405920 | Primary Facility | 2015-09-08 | Routine/Complete Inspection | No Violations Noted | |
2494080 | Primary Facility | 2016-06-14 | Routine/Complete Inspection | No Violations Noted | |
2511322 | Primary Facility | 2016-08-16 | Site Restoration | No Violations Noted | |
2527232 | Primary Facility | 2016-10-12 | Routine/Complete Inspection | No Violations Noted | |
2544869 | Primary Facility | 2016-12-13 | Routine/Complete Inspection | No Violations Noted | |
2624841 | Primary Facility | 2017-08-11 | Routine/Partial Inspection | No Violations Noted | Well is connected to sales line producing. Each well is equipped with a production unit, 210 Bbl brine tank, and corrosion and scale inhibitor tank. Both annuli are vented. |
2716647 | Primary Facility | 2018-04-10 | Routine/Complete Inspection | No Violations Noted | This well was drilled in a former surface mining area off of Tin Can Road in January 2014. No violations were noted during this inspection. |
2788634 | Primary Facility | 2018-10-15 | Administrative/File Review | No Violations Noted | |
2795690 | Primary Facility | 2018-10-29 | Administrative/File Review | No Violations Noted | |
2844571 | Primary Facility | 2019-02-26 | Routine/Complete Inspection | No Violations Noted | Inspected location. Follow up on previous noise complaint. Compressor being removed off of location at this time. |
For data sources see[7]