Well Details

Well ID: 34-167-27958
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality: Barlow Township
Operator Name: CARPER WELL SERVICE INC.
Well Pad ID:
Farm/Lease Name: DAVIS-HUFFMAN(SWIW#9)
License Status: Active Injection
License Date: 2008-09-03
Spud Date: 1984-12-23
Spud Drilling Contractor: LOTHES & LOTHES
Final Drill Date: 1984-12-29
Well Total Depth: 1850 ft
Configuration: Vertical
Latitude: 39.413652742
Longitude: -81.65752216

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1984-12-20 3133 PETROEL GeoDate 12/20/84
Oil and Gas 1984-12-20 Issued Date 12/20/84 Expired Date 6/18/85 Acres 0010000 Tool Type RTF Proposed Formation BEREA Proposed Depth 01850 Proposed Drill Depth 01850
Original Spud 1984-12-23
Completed 1984-12-29
Reached Total Depth 1984-12-29
Completion Report Received 1985-02-07
Change of Owner 1998-06-15 Operator changed from 3133, PETROEL to 6158, JONES PERLEY E
Change of Owner 1999-02-03 Operator changed from 6158, JONES PERLEY E to 3133, PETROEL
Change of Owner 2001-06-25 Operator changed from 3133, PETROEL to 7007, CARPER WELL SERVICE
Last Compliance Report 2008-08-07
APP 2008-09-03 Proposed Formations:BEREA, Issued Date:9/3/2008, Expired Date:9/3/2009 6:00:00 AM, Drilling unit acres:10, Proposed Well Type:SWD, Proposed Well Class:SWIW
Construction Permit Expires 2009-09-03
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 1802 1806 14

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 900 Bbl 30000 FRAC;H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1992 STONEBRIDGE OPERATING CO LLC 1906 17 365
2001 CARPER WELL SERVICE INC. 0 100 120
2002 CARPER WELL SERVICE INC. 0 100 120
2003 CARPER WELL SERVICE INC. 0 80 70
2004 CARPER WELL SERVICE INC. 0 79 65
2005 CARPER WELL SERVICE INC. 0 75 70
2006 CARPER WELL SERVICE INC. 0 70 70
2007 CARPER WELL SERVICE INC. 0 75 75
2008 CARPER WELL SERVICE INC. 0 20 40
2011 CARPER WELL SERVICE INC. 0 10 158

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1992 STONEBRIDGE OPERATING CO LLC Brine 0 365
2001 CARPER WELL SERVICE INC. Brine 0 120
2002 CARPER WELL SERVICE INC. Brine 0 120
2003 CARPER WELL SERVICE INC. Brine 20 70
2004 CARPER WELL SERVICE INC. Brine 20 65
2005 CARPER WELL SERVICE INC. Brine 20 70
2006 CARPER WELL SERVICE INC. Brine 20 70
2007 CARPER WELL SERVICE INC. Brine 20 75
2008 CARPER WELL SERVICE INC. Brine 15 40
2011 CARPER WELL SERVICE INC. Brine 0 158

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0000PL1620 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0014118249 2014-09-15 Salt Water Injection Well No Violations Inspection revealed that owner has nearly completed rework project at site and I informed him that flow line would need to be tested along with performing annulus test on tubing to ensure the division that they still have good casing integrity.
0029708929 2014-09-23 Salt Water Injection Well No Violations On site to hydro test new flow line and pressure test annulus of tubing company rep pumped fresh water through flow line and we tested it at 560 psi with no decline in pressure and then we moved on to performing annulus testing they placed 530 psi on annulus and we monitored pressure for 15 minutes with no decline in pressure.
0036822680 2017-12-14 Salt Water Injection Well No Violations Well is not in operation at this time.
0042858509 2011-05-24 Salt Water Injection Well No Violations Inspection this day found pump not running, dike area almost full of brine, fresh and skim of oil. Wrote violation on other well - applies to this well also - can called Carper and shut injection down until problems fixed. Large brine kill about 100 x 25 below and off to side of enpoundment - appears pit liner has a hole in it and brine moved under the brim of the dike and down into horse pasture. Millard says will address problems and call me with a plan.
0099312161 2013-07-25 Salt Water Injection Well No Violations Obtained water sample from inside and outside of dike. I was able to obtain sample from dike by dipping water out of it. I had to use a large syringe to obtain the sample from outside of the dike. I tested the water outside of the dike with high range Quantab test strips, and it measured 5.4 on the strip which is representative of 1268 parts per million (ppm) cloride. I then put the samples on ice, and took them directly to Cambridge lab.
0143082761 2014-05-12 Salt Water Injection Well No Violations Inspection revealed that owner has two more old tanks to be removed from site before they can start setting new storage tanks in dike area and it was discussed that they will replace flow line going to well head before placing well into operation.
0210520627 2010-05-25 Salt Water Injection Well No Violations Inspection this day found pump not running, good IDs at well and pump, skim of oil on pit at tanks, #530 on tubing, 0 on annulus.
0269531335 2013-11-04 Salt Water Injection Well No Violations Inspection on this day indicated that owner is presently installing new pit liner in tank area and placing sand on top of liner to help hold it in place.
0391114439 2013-07-29 Salt Water Injection Well No Violations I stopped to look and see if the tank battery dike had been sucked out. Dike had been sucked out with the exception of a few small pools on the bottom. Brush has been cut around the whole site.
0405741539 2011-03-08 Salt Water Injection Well No Violations Inspection this day found pump not running, on pressure on well. Dike area has been pumped free of water, still an oily mess.
0462431287 2014-08-13 Salt Water Injection Well No Violations Inspection revealed that owner has recently placed two 100 bbl. tanks at site and they plan on setting more storage tanks in the near future and also they plan on replacing flow line to both wells on the lease before placing them back into operation.
0499467593 2010-08-23 Salt Water Injection Well No Violations Inspection found well not in production, pump not running. Appears facility not getting much water, dike area needs pumped out with water with thin layer of oil on top. Called operator and asked he to get it cleaned out. No pressure on tubing or annulus.
0550908666 2014-06-26 Salt Water Injection Well No Violations Inspection revealed that owner has removed old tanks from facility and they are waiting on new storage tanks to be delivered to site and placed in storage area.
0577391960 2009-03-24 Salt Water Injection Well No Violations Well passed integrity test on 3/19/2009, holding pressure at 600#. Today, pressure testing the line - 2 3/8 steel line laid on top of ground - pressured up with injection pump to 560# - held and passed test. Will start injecting this afternoon.
0664843207 2013-07-24 Salt Water Injection Well No Violations Accompanied UIC III inspector Dave Ball on inspection of this well and tank battery. The tank battery has an excessive amount of fluid in it with oily fluid on top.
0668015797 2018-07-10 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation and I was on site to witness MIT testing of said well, they applied 580 psi of pressure and we monitored it for thirty minutes with no decline in pressure.
0695713456 2016-01-11 Salt Water Injection Well No Violations Injection pump not in operation during my inspection.
0702846340 2013-07-24 Salt Water Injection Well Violations Noted Inspection revealed that there was brine&oil within dike area and it appeared that someone had recently ran tanks over and owner has not complied with previous Compliance notice issued 5/24/11 for contamination at surface facility and dike not being liquid tight because it appears to be leaking because we ran Quantab test in water hole and they indicated that there was brine present outside of dike.

Note: Photos were taken and water samples were taken to Cambridge lab to be analyzed, Note: To properly fix dike owner will need to have tanks cleaned and removed from dike area and new liner installed after all contaminated material is removed from dike area and replaced with fresh soil.

0747898934 2010-11-29 Salt Water Injection Well No Violations Inspection this day found pump not running, wells not in use. Pressures showed 0#. Tickets from brine haulers showed last water brought in 11/23/2010. Dike area contained small amt. fresh water, very little oil - they seem to be doing better job of keeping oil out of dike area.
0823005044 2019-02-11 Salt Water Injection Well Violations Noted The Division has not received the 4th quarter brine disposal fees for 2018. Please forward disposal fees and sheets to the Division by 3/12/2019.
0858871157 2009-08-27 Salt Water Injection Well No Violations Inspection this day found Millard Carper changing filters, then starting pump up. Other well (#7401) still down. Pressure on this well to the limits - told him not to go any higher on the presssure - should reduce when get 2nd well going again.
0969939026 2012-01-31 Salt Water Injection Well No Violations I met with John Jack and Dylan from Triad and Jeff Jones from J & L Water Services to discuss plans for re-working the site and resolving the violation. See #7401 for full inspection The wells are still not in production.
1076431758 2004-02-10 Production Wells No Violations Inspection this day found no violations, well capable of producing with jack, belt off motor but can be put back on, tank area clean, fresh water in pit, IDs good, good dike
1083859212 2004-05-06 Production Wells No Violations Reinspect this well as last time visited was oily mess - pin hole in line at well to flowline - well not capable of producing. Today, hole fixed, still a little oily but much better, well capable of producing - have fixed jack.
1106082689 2017-02-08 Salt Water Injection Well No Violations Inspection revealed that well is not in operation at this time but I had owner come out and perform mini pressure test on annulus of tubing to ensure the division of casing integrity.
1140602274 2018-02-18 Salt Water Injection Well No Violations Injection pump not in operation today.


Called company rep and requested that fresh water within dike area be removed and properly disposed of.

1168715853 2010-03-09 Salt Water Injection Well No Violations Inspection this day found pump running, 370# on tubing, 0# on annulus. Good IDs at pump house and at well, small amount of fluid in dike area but they are working on clearing that. Very muddy, had to walk in.
1221736147 2017-08-24 Salt Water Injection Well No Violations Well not in operation at this time.
1237389802 2009-03-18 Salt Water Injection Well No Violations Running packer in well this day. Running a Halliburton R-4 tension packer - rebuilt - on 2 7/8 tubing. Packer appears in good working order and watched go in hole. Bond log shows cement on backside of 4.5 casing to 1479. 3/19/2009 - Packer set at 1773 - had originally put in 16 more but had to be pulled when packer wouldnt set. Well passed integrity test at 600# for 15 minutes.
1253014942 2017-01-06 Salt Water Injection Well No Violations Inspection today revealed that well is currently not in operation due to lack of brine hauling activity.
1275774418 2015-05-29 Salt Water Injection Well No Violations On site to witness MIT Testing of annulus of tubing and ensuring that they have good casing integrity company rep applied 585 psi of pressure and we monitored pressure for 15 minutes with no decline in pressures.(TEST PASSED)
1312230760 2011-07-27 Salt Water Injection Well No Violations Inspection this day found facility still down due to brine escape outside the dike. Appears brine kill area has not been treated with lime or re-seeded. Have heard facility is for sale but believe they need to follow thru on their violation. Oil very heavy on gravel inside dike - this should all be cleaned up - seems to be short-lived when it does get resolved. Will continue to monitor.
1332664684 2018-04-25 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation during my inspection.
1336326888 2002-03-14 Production Wells No Violations
1361342926 2017-05-02 Salt Water Injection Well No Violations Inspetion today indicated that injection pump was not in operation and it appears that wells are not being used much at this time.
1367615308 2013-08-20 Salt Water Injection Well No Violations On site to witness clean up efforts being made at site, owner is removing material from tank area and hauling it to a approved landfill and once all solids and liquids are removed they will remove tanks and then start rebuilding process of entire storage facility.
1381300462 2015-03-02 Salt Water Injection Well No Violations Inspection revealed that well is not in operation at this time, owner has rebuilt facility and they are waiting on better weather so they can cover exposed portions of containment liner so it wont rot due to exposure to the sunlight.
1383782406 2016-10-14 Salt Water Injection Well No Violations Well not in operation at this time.
1455390301 2014-03-10 Salt Water Injection Well No Violations Inspection revealed that well is down waiting on owner to complete rebuilding of storage tank facility.
1473185878 2016-09-06 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation and it was noted that injection line right away has been recently brush hogged and there was a worker on site weed eating around containment area during my inspection.
1491272739 2016-07-06 Salt Water Injection Well No Violations Inspection revealed that well is currently not being used.
1504393425 2015-11-17 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today.
1584860842 2009-12-01 Salt Water Injection Well No Violations Inspection this day found pump not running, pressures were 320# on tubing, 0# on annulus. No IDs at well or on house - asked operator to get IDs up and would recheck next week. Reclamation has been done on this well and looks very nice - grass growing. 12/7/09 - IDs now up at well, will add sticker at pump house.
1625795754 2015-07-01 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and we measured dike area and recorded total amount of tanks with in dike area.

61x40x48 high with a calculated volume of 1733 bbl and there is 5-210 bbl placed within dike area.

1655151667 2013-12-03 Salt Water Injection Well No Violations Owner is presently placing sand on top of liner making preparation for spotting of new storage tanks when are delivered.

Note: Before placing well back into operation we will need to perform pressure test on annulus of tubing.

1670145972 2002-03-14 Production Wells No Violations
1724166923 2015-03-23 Salt Water Injection Well No Violations Inspection revealed that owner has completed remedial work required at site and is ready to place wells on the lease back into operation.

Note: Witnessed MIT testing on annulus of tubing today owner applied 550 psi and we monitored pressure for 15 minutes with no decline in pressure. Dike measurements are as follows 25X50X48TALL with a calculated volume of 888 bbl.

1728242773 2013-02-12 Salt Water Injection Well No Violations Inspection revealed that well is not in operation at this time, walked flow line to check for leaks none were found.

Note: Called company and requested that they have positive pressure applied to annulus of tubing and also remove fresh water build up in tank area.

1801031880 2018-12-06 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.


Note: Well does not appear to be used much at this time.

1947441163 2012-04-12 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today and it appears that well has been out of service for quite some time, it has been noted that Green Hunter is working on service agreement with Carper to operate well and clean up existing issues at facility.
1947703385 2012-03-05 Salt Water Injection Well No Violations My inspection this day is routine - facility still has citation, no changes have been made. The dike area this day full of fresh rain water. Hopefully, Triad will get started soon and reworking the site and get wells into production.
1967576347 2011-11-23 Salt Water Injection Well No Violations My inspection this day found facility was still down. Fresh water, about 1 deep, is inside the diked area. This is due to heavy rains in last few days. The operator has been pumping area out. The brine kill area is growing back slowly. Proper identification is posted. The Notice of Violation cannot be resolved yet. Did not go to well this day.
1971638443 2017-06-12 Salt Water Injection Well No Violations Well not in operation at this time.

Note: Walked flowline area to both wells on the lease today.

2012194893 2013-10-04 Salt Water Injection Well No Violations Clean up continues at site owner has removed all storage tanks from dike area and is in process of removing all contaminated material from dike area and once all material is removed they will begin rebuilding facility.
2022100403 2013-09-09 Salt Water Injection Well No Violations Clean up continues within tank area.
2038859740 2003-02-11 Production Wells No Violations no violations noted day of inspection.
2070598164 2013-03-18 Salt Water Injection Well No Violations Inspection revealed that well was not in operation and owner still needs to have tanks removed and cleaned out and containment area fixed up and drains from pump house plumbed to vault area.
2094693522 2009-05-29 Salt Water Injection Well No Violations Inspection this day found well/pump not in use. Walked out to well, checked pressures. IDs still needed at well, on pumphouse building and tanks for this well.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0702846340 US-OH-127939 2017-06-29 9-3-04(A) Pollution/Contamination
0702846340 US-OH-127940 2017-06-29 9-3-05(B)7 Contamination at surface facility (permit before 6-1-82)
0702846340 US-OH-127941 2017-06-29 9-3-06(G) Permit not displayed
0702846340 US-OH-127942 2017-06-29 9-3-08(D) Failure to repair pits/Unlawful use of pits
0823005044 US-OH-129284 2019-04-08 Failure to report disposal fees

For data sources see[9]

References