Well ID: 34-099-22502 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.942987447,"lon":-80.92767827,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Mahoning | |
Municipality: Goshen Township | |
Operator Name: ENERVEST OPERATING LLC | |
Well Pad ID: | |
Farm/Lease Name: KARLEN UNIT | |
License Status: Producing | |
License Date: 1991-08-16 | |
Spud Date: 1991-08-16 | |
Spud Drilling Contractor: QUAPAW | |
Final Drill Date: 1991-08-23 | |
Well Total Depth: 5561 ft | |
Configuration: Vertical | |
Latitude: 40.942987447 | |
Longitude: -80.92767827 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1991-08-16 | Issued Date 8/16/91 Expired Date 8/15/92 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 05561 Proposed Drill Depth 05561 |
Original Spud | 1991-08-16 | |
Completed | 1991-08-23 | |
Reached Total Depth | 1991-08-23 | |
CO | 1991-09-16 | 3069 MURNANE JOSEPH M GeoDate 8/16/91 |
Completion Report Received | 1991-09-23 | |
Construction Permit Expires | 1992-08-15 | |
CO | 1992-12-28 | 213 LOMAK OPERATING CO GeoDate 8/16/91 |
Change of Owner | 2000-06-27 | Operator changed from 213, RANGE OPERATING COMPANY to 6674, GREAT LAKES ENERGY PTNSHP LLC |
Change of Owner | 2010-04-08 | Operator changed from 6674, RANGE RESOURCES-APPALACHIA LLC to 7578, ENERVEST OPERATING LLC |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5381 | 5430 | 26 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
GEL | 0 | 500 Lbs | 40000 | |||
H2O | 0 | 68000 Gal | 0 | |||
ACID | 8 | 500 Gal | 0 | FRAC W/68M GAL SAND LADEN FLUID |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0000018849 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 3/30/93 INSPECTOR BRETT FARNSWORTH DATE 03/3019/93 DATA FROM OLD VAX INFO | |
001216i416 | 2002-04-22 | Production Wells | No Violations | Attach the power line to the power pole where it has come lose and is laying on the ground. Obtained GPS coordinates. |
001216i601 | 2002-05-29 | Production Wells | No Violations | The power line has ben placed back on the pole. |
0260191081 | 2018-01-16 | Production Wells | No Violations | The purpose of my inspection was to conduct a status check on well #2-2502. ODNR-DOGRM Northeast District Supervisor Stephen Ochs was present during the inspection. Access to the well and tank battery was snow covered. The well was enclosed by a chain-link fence enclosure. The 8.625 well head was below grade. The 4.5 production casing was equipped with an electric pump jack. The drive belts were removed. Production valves were in the open position. No leaks were observed. Staining consistent with a legacy operation was present. A snow covered dike was present around the production equipment. Equipment within the dike consisted of one (1) horizontal separator and one (1) 210 bbl production tank and one (1) 100 steel brine tank. The separator remained in good repair and contained a current 31 day production chart. The production tank remained in good repair and contained correct identification. Valves were closed and plugged. The brine tank remained in good repair. The inlet valve was closed. No violations were observed during this inspection. |
0783087073 | 2002-04-22 | Production Wells | No Violations | FOLLOW UP TO NOV # 1216i416 Attach the power line to the power pole where it has come lose and is laying on the ground. Obtained GPS coordinates. |
2054638037 | 2004-08-26 | Production Wells | No Violations | The power line has been put back on the power pole. Recommend case be resolved. |
For data sources see[9]