Revision as of 11:16, 31 August 2019

Well Details

Well ID: 34-103-21711
Loading map...
Country: United States
State: Ohio
County: Medina
Municipality: York Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: BURNSIDE CHARLES C
License Status: Storage Well
License Date: 1968-08-22
Spud Date: 1968-10-11
Spud Drilling Contractor:
Final Drill Date: 1968-12-12
Well Total Depth: 3032 ft
Configuration: Vertical
Latitude: 41.163017436
Longitude: -81.93723329

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1968-10-11 STORAGE 3, REOPEN 8-28-68, GL=978.5
Completed 1968-12-12 STORAGE 3, REOPEN 8-28-68, GL=978.5
Reached Total Depth 1968-12-12 STORAGE 3, REOPEN 8-28-68, GL=978.5
Record Last Modified 2013-04-10 STORAGE 3, REOPEN 8-28-68, GL=978.5

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2014-07-30 H2O 0 13272 Gal 28000 OTHER Nabors Completion and Production Services conducted the fracture stimulation of the well. Guar was used as a cross link agent for the liquid portion of the fluid. Nitrogen gas was also added to the slurry. 54,500 cubic ft of nitrogen was used. Reported breakdown pressure is injection test pressure because there was no actual break of the formation. The job was not witnessed; the operator supplied the records.

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2001 COLUMBIA GAS TRANSMISSION LLC 0 0 0
2002 COLUMBIA GAS TRANSMISSION LLC 0 0 0
2003 COLUMBIA GAS TRANSMISSION LLC 0 0 0
2004 COLUMBIA GAS TRANSMISSION LLC 0 0 0
2005 COLUMBIA GAS TRANSMISSION LLC 0 0 0
2006 COLUMBIA GAS TRANSMISSION LLC 0 0 0

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2001 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
2002 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
2003 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
2004 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
2005 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
2006 COLUMBIA GAS TRANSMISSION LLC Brine 0 0

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0098575216 2015-02-04 Storage Well No Violations Performed annual inspection for Columbia Gas Storage Well #10784 on 02/04/2015. The well is equipped with a wellhead with 1-master valve and 1-wing valve, a drip tank, and 1-10 bbl fiberglass tank located within a fiberglass dike. Well identification is clearly displayed. No problems were noted at the time of the inspection.
0380378940 2019-02-08 Storage Well No Violations Performed annual inspection for Columbia Gas Storage Well #10784 on 02/08/2019. The well is equipped with a flanged wellhead with 1-master valve and 1-wing valve, a drip, and 1-10 bbl fiberglass tank located within a fiberglass dike. Well identification is clearly displayed. The well is located ~140 from its RBDMS location. A map showing the location discrepancy, as well as a request for the location to be updated in RBDMS was sent to Aaron Lantz (DOGRM Columbus). No other problems were noted at the time of the inspection.
0683023258 2014-04-02 Storage Well No Violations Performed annual inspection for Columbia Gas Storage Well# 10784 on 04/02/2014. Well is equipped with a drip tank and 1-5 bbl fiberglass tank within a fiberglass dike. Well identification is clearly displayed. No problems were noted at the time of the inspection.
0883661103 2018-10-04 Storage Well No Violations Conducted annual Inspected for Columbia Gas Storage Well #10784. This well is equipped with a flanged wellhead with a drip bottle. Well identification is clearly displayed. No compliance issues were found at the time of this inspection.
0950000340 2013-01-14 Storage Well No Violations I inspected Columbia Gas Transmission storage well#10784 today. The well is located in the Medina storage field, York Township, Medina County, Ohio. The well is equipped with a main valve, side valve and a 3.00 line to the drip tank. There is a 1.00 line from the drip tank to a 10 BBL storage tank. The well is properly tagged and a well identification sign is mounted on the drip tank and it is legibly marked. No violations found.
1774355590 2017-12-27 Storage Well No Violations Performed annual inspection for Columbia Gas Storage Well #10784 on 12/27/2017. The well is equipped with a flanged wellhead with 1-master valve and 1-wing valve, a drip, and 1-10 bbl fiberglass tank located within a fiberglass dike. Well identification is clearly displayed. No problems were noted at the time of the inspection.

For data sources see[8]

References