If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-059-25687 | | Well ID: 37-059-25687 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="17" | {{#display_map: 39.921961, -80.218236 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 19: | Line 19: | ||
| Farm/Lease Name: GROOMS UNIT 9H | | Farm/Lease Name: GROOMS UNIT 9H | ||
|- | |- | ||
− | | License Status: | + | | License Status: |
|- | |- | ||
− | | Spud Date: | + | | Spud Date: |
|- | |- | ||
| Permit Date: 2011-03-14 | | Permit Date: 2011-03-14 | ||
+ | |- | ||
+ | | Well Type: GAS | ||
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
|- | |- | ||
| Configuration: Horizontal Well | | Configuration: Horizontal Well | ||
+ | |- | ||
+ | | Conservation: Yes | ||
|- | |- | ||
| Latitude: 39.921961 | | Latitude: 39.921961 | ||
Line 49: | Line 53: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Well History == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Date | ||
+ | !scope="col" | Event | ||
+ | |- | ||
+ | | 2011-03-14 | ||
+ | | New Permit Application | ||
+ | |- | ||
+ | | 2011-08-28 | ||
+ | | Performed Spud Operation | ||
+ | |- | ||
+ | | 2012-03-21 | ||
+ | | Drilling Completion | ||
+ | |- | ||
+ | | 2012-09-21 | ||
+ | | Perforation | ||
+ | |- | ||
+ | | 2012-09-26 | ||
+ | | Performed Stimulation | ||
+ | |- | ||
+ | | 2013-07-23 | ||
+ | | DEVIATED | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources | ||
+ | | date = 2020-02-27 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-02-27 }}</ref> | ||
== Fracking Activities == | == Fracking Activities == | ||
==== Fracking Jobs ==== | ==== Fracking Jobs ==== | ||
Line 62: | Line 95: | ||
| 2012-09-21 | | 2012-09-21 | ||
| 2012-09-21 | | 2012-09-21 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 6,491 |
− | | style="text-align: right;" | 4,307,696 | + | | style="text-align: right;" | 4,307,696 |
| style="text-align: right;" | | | style="text-align: right;" | | ||
|- | |- | ||
Line 204: | Line 237: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-06-19 }}</ref> | | accessdate = 2019-06-19 }}</ref> | ||
+ | == Stimulation Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Stimulation Date | ||
+ | !scope="col" | Phase Number | ||
+ | !scope="col" | Chemical Agent | ||
+ | !scope="col" | Volume (gal) | ||
+ | !scope="col" | Treating Pressure (psi) | ||
+ | !scope="col" | Breakdown Pressure (psi) | ||
+ | |- | ||
+ | | 2012-09-26 | ||
+ | | style="text-align: right;" | | ||
+ | |||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Completion Reports - Stimulations | ||
+ | | publisher = Pennsylvania Department of Conservation and Natural Resources | ||
+ | | date = 2020-03-02 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-03-02 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 289: | Line 345: | ||
| 2019 | | 2019 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 266,671.00 |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 365 |
| style="text-align: right;" | 0.00 | | style="text-align: right;" | 0.00 | ||
| style="text-align: right;" | 0 | | style="text-align: right;" | 0 | ||
Line 314: | Line 370: | ||
| 2012 | | 2012 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | | + | | Fracing Fluid Waste |
− | | style="text-align: right;" | 1, | + | | style="text-align: right;" | 3,120.15 Bbl |
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
+ | |- | ||
+ | | 2012 | ||
+ | | [[CHEVRON APPALACHIA LLC]] | ||
+ | | Fracing Fluid Waste | ||
+ | | style="text-align: right;" | 1,170.02 Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| WMGR123SW001 | | WMGR123SW001 | ||
Line 321: | Line 384: | ||
| 2012 | | 2012 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | | + | | Drilling Fluid Waste |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 1,760.00 Bbl |
− | | | + | | CENTRALIZED TREATMENT PLANT FOR RECYCLE |
− | | | + | | WMGR123SW001 |
|- | |- | ||
− | | | + | | 2013 |
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Fracing Fluid Waste | + | | Fracing Fluid Waste |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 17.50 Bbl |
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| WMGR123SW001 | | WMGR123SW001 | ||
Line 335: | Line 398: | ||
| 2013 | | 2013 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Fracturing Fluid Waste | + | | Fracturing Fluid Waste |
| style="text-align: right;" | 27.71 Tons | | style="text-align: right;" | 27.71 Tons | ||
| LANDFILL | | LANDFILL | ||
Line 342: | Line 405: | ||
| 2013 | | 2013 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 1,572.00 Bbl |
− | | | + | | REUSE OTHER THAN ROAD SPREADING |
− | | | + | | |
|- | |- | ||
| 2013 | | 2013 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Fracing Fluid Waste | + | | Fracing Fluid Waste |
| style="text-align: right;" | 536.25 Bbl | | style="text-align: right;" | 536.25 Bbl | ||
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
Line 356: | Line 419: | ||
| 2013 | | 2013 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Fracing Fluid Waste | + | | Fracing Fluid Waste |
| style="text-align: right;" | 4,018.38 Bbl | | style="text-align: right;" | 4,018.38 Bbl | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
Line 370: | Line 426: | ||
| 2014 | | 2014 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 23.75 Bbl |
− | | | + | | INJECTION DISPOSAL WELL |
− | | | + | | 34-121-23995 |
|- | |- | ||
| 2014 | | 2014 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Fracturing Fluid Waste | + | | Fracturing Fluid Waste |
| style="text-align: right;" | 2.22 Tons | | style="text-align: right;" | 2.22 Tons | ||
| LANDFILL | | LANDFILL | ||
Line 384: | Line 440: | ||
| 2014 | | 2014 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 390.75 Bbl | | style="text-align: right;" | 390.75 Bbl | ||
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
Line 391: | Line 447: | ||
| 2014 | | 2014 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 1,589.75 Bbl |
− | | | + | | REUSE OTHER THAN ROAD SPREADING |
− | | | + | | |
|- | |- | ||
| 2015 | | 2015 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 1,298.75 Bbl | | style="text-align: right;" | 1,298.75 Bbl | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
Line 405: | Line 461: | ||
| 2016 | | 2016 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 444.13 Bbl | | style="text-align: right;" | 444.13 Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
Line 412: | Line 468: | ||
| 2016 | | 2016 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 756.57 Bbl | | style="text-align: right;" | 756.57 Bbl | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
Line 419: | Line 475: | ||
| 2017 | | 2017 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Soil Contaminated by Oil |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 0.03 Tons |
− | | | + | | RESIDUAL WASTE TRANSFER FACILITY |
− | | | + | | 101532 |
+ | |- | ||
+ | | 2017 | ||
+ | | [[CHEVRON APPALACHIA LLC]] | ||
+ | | Produced Fluid | ||
+ | | style="text-align: right;" | 15.00 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-119-28776 | ||
|- | |- | ||
| 2017 | | 2017 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 136.13 Bbl |
− | | | + | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA |
− | | | + | | |
|- | |- | ||
| 2017 | | 2017 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Soil Contaminated by Oil & Gas Related Spills | + | | Soil Contaminated by Oil & Gas Related Spills |
| style="text-align: right;" | 0.03 Tons | | style="text-align: right;" | 0.03 Tons | ||
| RESIDUAL WASTE TRANSFER FACILITY | | RESIDUAL WASTE TRANSFER FACILITY | ||
Line 440: | Line 503: | ||
| 2017 | | 2017 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 210.10 Bbl |
− | | | + | | RESIDUAL WASTE PROCESSING FACILITY |
− | | | + | | WMGR123SW019 |
|- | |- | ||
| 2017 | | 2017 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 13.75 Bbl |
− | | | + | | RESIDUAL WASTE PROCESSING FACILITY |
− | | | + | | WMGR123SW005 |
|- | |- | ||
| 2017 | | 2017 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 55.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-157-25511 |
|- | |- | ||
| 2017 | | 2017 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 692.51 Bbl |
− | | | + | | REUSE (AT WELL PAD) |
− | | | + | | |
|- | |- | ||
| 2018 | | 2018 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 193.76 Bbl |
− | | REUSE AT | + | | REUSE (AT WELL PAD) |
| | | | ||
|- | |- | ||
| 2018 | | 2018 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 285.40 Bbl |
− | | REUSE | + | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA |
| | | | ||
|- | |- | ||
| 2018 | | 2018 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 40.63 Bbl | | style="text-align: right;" | 40.63 Bbl | ||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
Line 489: | Line 552: | ||
| 2019 | | 2019 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 31.25 Bbl |
+ | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
+ | | | ||
+ | |- | ||
+ | | 2019 | ||
+ | | [[CHEVRON APPALACHIA LLC]] | ||
+ | | Produced Fluid | ||
+ | | style="text-align: right;" | 290.00 Bbl | ||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | |
Well ID: 37-059-25687 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.921961,"lon":-80.218236,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Greene | |
Municipality: Franklin Township | |
Operator Name: CHEVRON APPALACHIA LLC | |
Well Pad ID: 148450 | |
Farm/Lease Name: GROOMS UNIT 9H | |
License Status: | |
Spud Date: | |
Permit Date: 2011-03-14 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 39.921961 | |
Longitude: -80.218236 |
Date | Event |
---|---|
2011-03-14 | New Permit Application |
2011-08-28 | Performed Spud Operation |
2012-03-21 | Drilling Completion |
2012-09-21 | Perforation |
2012-09-26 | Performed Stimulation |
2013-07-23 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-09-21 | 2012-09-21 | 6,491 | 4,307,696 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | GBW-30 BREAKER | Halliburton Energy Services | Gel Breaker | Hemicellulase enzyme | 9012-54-8 | 15.00 | 0.00001000 | |
Carbohydrates | 95.00 | 0.00009000 | ||||||
WG-36 GELLING AGENT | Halliburton Energy Services | Water Viscosifier | Guar gum | 9000-30-0 | 100.00 | 0.00303000 | ||
FR-66 Friction Reducer | Halliburton Energy Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.03 | ||
ASP 900 | Nalco | Friction Reducer | Ammonium sulfate | 7783-20-2 | 30.00 | |||
Biocide EC 6116A | Nalco | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30.00 | 0.00748000 | ||
Dibromoacetonitrile | 3252-43-5 | 5.00 | 0.00125000 | |||||
Polyethylene glycol | 25322-68-3 | 60.00 | 0.01 | |||||
Proppant (lbs) | Proppant | 8.71 | 9.62 | |||||
Clean Volume (gals) | Carrier/Base Fluid | 91.29 | 100.00 | |||||
EC6673W | Nalco | Iron Control | Ethylene glycol | 107-21-1 | 30.00 | 0.00688000 | ||
7.5 Hcl Acid | Used to open perfs | Hydrochloric acid | 7647-01-0 | 7.50 | 0.30 | |||
EC6486A | Nalco | Scale Inhibitor | Ethylene glycol | 107-21-1 | 30.00 | 0.00740000 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2012-09-26 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | ATLAS RESOURCES LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CHEVRON APPALACHIA LLC | 1,490,081.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | CHEVRON APPALACHIA LLC | 777,181.00 | 365 | 0.00 | 0 | 133.76 | 184 |
2015 | CHEVRON APPALACHIA LLC | 570,798.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CHEVRON APPALACHIA LLC | 452,278.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CHEVRON APPALACHIA LLC | 323,929.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHEVRON APPALACHIA LLC | 239,631.00 | 273 | 0.00 | 0 | 0.00 | 0 |
2019 | CHEVRON APPALACHIA LLC | 266,671.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 3,120.15 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 1,170.02 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2012 | CHEVRON APPALACHIA LLC | Drilling Fluid Waste | 1,760.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2013 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 17.50 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2013 | CHEVRON APPALACHIA LLC | Fracturing Fluid Waste | 27.71 Tons | LANDFILL | 073 114 654 |
2013 | CHEVRON APPALACHIA LLC | Produced Fluid | 1,572.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 536.25 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2013 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 4,018.38 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CHEVRON APPALACHIA LLC | Produced Fluid | 23.75 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2014 | CHEVRON APPALACHIA LLC | Fracturing Fluid Waste | 2.22 Tons | LANDFILL | 100172 |
2014 | CHEVRON APPALACHIA LLC | Produced Fluid | 390.75 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014 | CHEVRON APPALACHIA LLC | Produced Fluid | 1,589.75 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | CHEVRON APPALACHIA LLC | Produced Fluid | 1,298.75 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CHEVRON APPALACHIA LLC | Produced Fluid | 444.13 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016 | CHEVRON APPALACHIA LLC | Produced Fluid | 756.57 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | CHEVRON APPALACHIA LLC | Soil Contaminated by Oil | 0.03 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 15.00 Bbl | INJECTION DISPOSAL WELL | 34-119-28776 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 136.13 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017 | CHEVRON APPALACHIA LLC | Soil Contaminated by Oil & Gas Related Spills | 0.03 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 210.10 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 13.75 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 55.00 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 692.51 Bbl | REUSE (AT WELL PAD) | |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 193.76 Bbl | REUSE (AT WELL PAD) | |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 285.40 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 40.63 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | CHEVRON APPALACHIA LLC | Produced Fluid | 31.25 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019 | CHEVRON APPALACHIA LLC | Produced Fluid | 290.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2006244 | Primary Facility | 2011-09-21 | Drilling/Alteration | No Violations Noted | CONDUCTOR IS SET AT 100'. NO OTHER DRILLING. |
2027571 | Primary Facility | 2011-09-13 | Routine/Complete Inspection | No Violations Noted | The Department was at the above referenced Marcellus Well to conduct a Routine Inspection. The operator is finishing up construction of the pad and lining the pits. The Department reviewed the E/S Plan on site. The E/S controls appear to be in good condition. The Operator is currently adding E/S controls to make sure all the sediment stays on site. Temporary stabilization has been obtained on this site. Grass is beginning to grow on the fill slopes. |
2035020 | Primary Facility | 2012-01-09 | Drilling/Alteration | No Violations Noted | WELL DRILLED TO KOP. WILL BE COMPLETED WITH A BIGGER RIG. |
2051389 | Primary Facility | 2012-03-13 | Drilling/Alteration | No Violations Noted | Patterson 334 drilling for Chevron.Rig had just skidded over getting ready to start driling Grooms 9-H.Site in good condition. |
2051462 | Primary Facility | 2012-03-13 | Drilling/Alteration | No Violations Noted | |
2108321 | Primary Facility | 2012-09-25 | Administrative/File Review | In Compliance with Policy | The Department received a spill notification from the Operator on 9/25/12. 50 gallons of re-use water was spilled to the ground on secondary containment. The Operator vacuumed up the re-use water and disposed. The Department did not conduct a site inspection. The Operator is in compliance with the spill policy. |
2449064 | Primary Facility | 2016-01-09 | Routine/Partial Inspection | No Violations Noted | On 01/09/16 at approximately 0800 hours I conducted a routine partial inspection of the Grooms Unit. The Act 9 sign was in place and all required documents were present at the site. I met with Nick Staffieri of Chevron to discuss changes at the site.
One of the forebays on the site (#3) was moved within the same drainage area as proposed, but without Departmental approval. This is a violation of 102.5(m)(4). It is recommended that Chevron submit for a minor modification to reflect current conditions at the site. |
2636961 | Primary Facility | 2017-09-15 | Site Restoration | No Violations Noted | A site restoration inspection was conducted in response to an NOT submittal by Chevron. The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and meets and exceeds 70% uniform vegetative cover. There were no signs of erosion observed at the time of inspection. The production equipment appeared to be in good condition. The site meets the requirements for permit termination. The NOT is approved. |
For data sources see[9]