If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 305: | Line 305: | ||
|- | |- | ||
|} | |} | ||
− | ==== Penalties Applied ==== | + | <!--==== Penalties Applied ==== |
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
!scope="col" | Violation ID | !scope="col" | Violation ID | ||
Line 316: | Line 316: | ||
!scope="col" | Amount Collected | !scope="col" | Amount Collected | ||
|- | |- | ||
− | | | + | |}--> |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
| title =Oil and Gas Compliance Report | | title =Oil and Gas Compliance Report |
Well ID: 37-117-20486 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.889568,"lon":-76.965601,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Tioga | |
Municipality: Rutland Township | |
Operator Name: SWEPI LP | |
Well Pad ID: 148618 | |
Farm/Lease Name: JENKINS 523 5H | |
License Status: PLUGGED & ABANDONED | |
Spud Date: | |
Permit Date: 2009-10-26 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.889568 | |
Longitude: -76.965601 |
Date | Event |
---|---|
2009-10-26 | New Permit Application |
2009-11-24 | Performed Spud Operation |
2009-11-28 | Drilling Completion |
2016-04-25 | Drilling Completion |
2016-05-24 | NEWLY DRILLED |
2016-07-28 | FULLY PLUGGED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | EAST RESOURCES MGMT LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1901143 | Primary Facility | 2010-07-23 | Compliance Evaluation | Violation(s) Noted | Pit inspection. Follow up done on 10-18-10. Pit removed and violations corrected. TLT |
1920388 | Primary Facility | 2010-10-18 | Follow-up Inspection | No Violations Noted | Follow up inspection to resolve viols from 7-23-10 insp. TLT |
1970332 | Primary Facility | 2011-05-02 | Compliance Evaluation | No Violations Noted | drill cuttings in ditch |
1981223 | Primary Facility | 2011-06-13 | Follow-up Inspection | No Violations Noted | violations on 1V at this site. now it is restored |
2023291 | Primary Facility | 2011-11-28 | Follow-up Inspection | No Violations Noted | closing viols from May 2, 2011 |
2263217 | Primary Facility | 2014-04-08 | Site Restoration | No Violations Noted | Site restored. 1 vertical well and 1 conductor on site. |
2490240 | Primary Facility | 2016-06-01 | Plugging(Includes Plugged/Mined Through) | No Violations Noted |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1901143 | 591912 | 07/23/2010 | 2010-07-23 | 78.56PITCNST - Impoundment not structurally sound, impermeable, 3rd party protected, greater than 20" of seasonal high ground water table | Administrative | 78.56(a)(4) for failure to maintain a pit containing pollutional substances as impermeable. Multiple punctures in the liner were observed along south side of drill pit. TLT |
1901143 | 591913 | 07/23/2010 | 2010-07-23 | 78.56FRBRD - Failure to maintain 2' freeboard in an impoundment | Administrative | 78.56(a)(2) for failure to maintain 2 feet of freeboard in the drill pit. TLT |
1901143 | 591914 | 07/23/2010 | 2010-07-23 | 78.56LINER - Improperly lined pit | Administrative | 78.56(a)(4)(ii) for failure to construct the liner subbase so as not to puncture or tear the liner. Rocks protruding underneath liner in multiple areas. TLT |
For data sources see[6]