If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-005-30666 | | Well ID: 37-005-30666 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 40.805791, -79.524886 | width=100% | height=100% }} |
+ | |- | ||
+ | | County: [[Armstrong County, Pennsylvania|Armstrong]] | ||
+ | |- | ||
+ | | Municipality: [[West Kittanning Borough, Armstrong County, Pennsylvania|West Kittanning Borough]] | ||
|- | |- | ||
| Operator Name: [[MDS ENERGY LTD]] | | Operator Name: [[MDS ENERGY LTD]] | ||
+ | |- | ||
+ | | Well Pad ID: | ||
+ | |- | ||
+ | | Farm/Lease Name: FLYNN 1-2 | ||
|- | |- | ||
| First Permit Date: 2010-06-10 | | First Permit Date: 2010-06-10 | ||
Line 17: | Line 25: | ||
| Horizontal: No | | Horizontal: No | ||
|- | |- | ||
− | | Violations: | + | | Well Status: ACTIVE |
+ | |- | ||
+ | | Violations: 0 | ||
|- | |- | ||
| Latitude: 40.805791 | | Latitude: 40.805791 | ||
Line 34: | Line 44: | ||
!scope="col" | OIL PRODUCTION DAYS | !scope="col" | OIL PRODUCTION DAYS | ||
|- | |- | ||
− | | | + | | 2010-0 |
− | | style="text-align:right;" | | + | | style="text-align:right;" | 0.0 |
− | | style="text-align:right;" | | + | | style="text-align:right;" | 0.0 |
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | |- | ||
+ | |- | ||
+ | | 2011-0 | ||
+ | | style="text-align:right;" | 11543.0 | ||
+ | | style="text-align:right;" | 180.0 | ||
| style="text-align:right;" | 0.0 | | style="text-align:right;" | 0.0 | ||
| style="text-align:right;" | 0.0 | | style="text-align:right;" | 0.0 | ||
Line 52: | Line 71: | ||
|- | |- | ||
|- | |- | ||
− | | | + | | 2013-0 |
− | | style="text-align:right;" | | + | | style="text-align:right;" | 7451.0 |
− | | style="text-align:right;" | | + | | style="text-align:right;" | 323.0 |
| style="text-align:right;" | 0.0 | | style="text-align:right;" | 0.0 | ||
| style="text-align:right;" | 0.0 | | style="text-align:right;" | 0.0 | ||
Line 61: | Line 80: | ||
|- | |- | ||
|- | |- | ||
− | | | + | | 2014-0 |
− | | style="text-align:right;" | | + | | style="text-align:right;" | 5421.0 |
− | | style="text-align:right;" | | + | | style="text-align:right;" | 273.0 |
| style="text-align:right;" | 0.0 | | style="text-align:right;" | 0.0 | ||
| style="text-align:right;" | 0.0 | | style="text-align:right;" | 0.0 | ||
Line 70: | Line 89: | ||
|- | |- | ||
|} | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Oil and Gas Historical Production Report | ||
+ | | publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2015-05-26 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production | ||
+ | | accessdate = 2015-05-27 }}</ref> | ||
== Waste Data == | == Waste Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 82: | Line 107: | ||
!scope="col" | FACILITY STATE | !scope="col" | FACILITY STATE | ||
|- | |- | ||
− | | | + | | 2011-0 |
| PRODUCED FLUID | | PRODUCED FLUID | ||
− | | style="text-align:right;" | | + | | style="text-align:right;" | 42.0 |
| Bbl | | Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| PA0101508 | | PA0101508 | ||
− | | | + | | FLUID RECOVERY SERVICE FRANKLIN FACILITY |
| FRANKLIN | | FRANKLIN | ||
| PA | | PA | ||
|- | |- | ||
|- | |- | ||
− | | | + | | 2012-0 |
| PRODUCED FLUID | | PRODUCED FLUID | ||
− | | style="text-align:right;" | | + | | style="text-align:right;" | 33.0 |
| Bbl | | Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| PA0101508 | | PA0101508 | ||
− | | | + | | FLUID RECOVERY SERVICE FRANKLIN FACILITY |
| FRANKLIN | | FRANKLIN | ||
| PA | | PA | ||
|- | |- | ||
|- | |- | ||
− | | | + | | 2014-0 |
| PRODUCED FLUID | | PRODUCED FLUID | ||
− | | style="text-align:right;" | | + | | style="text-align:right;" | 46.0 |
| Bbl | | Bbl | ||
− | | | + | | CENT WASTE TRT FAC NPDES DISCHARGE |
− | | | + | | PA0095443 |
− | | | + | | CREEKSIDE TREATMENT FACILITY |
− | | | + | | CREEKSIDE |
| PA | | PA | ||
|- | |- | ||
|} | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Oil and Gas Historical Waste Report | ||
+ | | publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2015-05-26 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste | ||
+ | | accessdate = 2015-05-26 }}</ref> | ||
== Inspection Data == | == Inspection Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 122: | Line 153: | ||
!scope="col" | COMMENT | !scope="col" | COMMENT | ||
!scope="col" | VIOLATION ID | !scope="col" | VIOLATION ID | ||
+ | !scope="col" | VIOLATION CODE | ||
+ | !scope="col" | VIOLATION_COMMENT | ||
|- | |- | ||
| 1933398 | | 1933398 | ||
Line 127: | Line 160: | ||
| No Violations Noted | | No Violations Noted | ||
| Rigging up and preparing to spud at time of inspection. Proposed TD = 3456' with casing plan as follows: As needed - 13 3/8", as needed - 9 3/8", 1156' - 0.231" wall 7". Pit not lined at time of inspection. Discussed with operator rep Randy Morris that pit wall facing Flynn tire building was falling in and needed addressed. Well has several buildings within 200'; discussed with operator rep Randy Morris that well control (BOP, flare stack, kill-fluids) should be attended to. Inspection conducted w/OGI D. Catalano. | | Rigging up and preparing to spud at time of inspection. Proposed TD = 3456' with casing plan as follows: As needed - 13 3/8", as needed - 9 3/8", 1156' - 0.231" wall 7". Pit not lined at time of inspection. Discussed with operator rep Randy Morris that pit wall facing Flynn tire building was falling in and needed addressed. Well has several buildings within 200'; discussed with operator rep Randy Morris that well control (BOP, flare stack, kill-fluids) should be attended to. Inspection conducted w/OGI D. Catalano. | ||
+ | | | ||
+ | | | ||
| | | | ||
|- | |- | ||
Line 134: | Line 169: | ||
| No Violations Noted | | No Violations Noted | ||
| Cleaning out hole in prep for running 1136' of 0.231" wall 7" casing at time of inspection. Casing set: 40' - 13 3/8" 37 lb/ft, 210' - 9 5/8" 26 lb/ft in 229' of 12 1/4" hole; cement basket set at 120'. On 12/08/10 cemented 9 5/8" with 90 sacks of "A" containing 3% CACL2 & 1/2# flake (yield=1.18 cu ft/sk). Pumping of cement completed at 11:11. Grouted backside of 9 5/8" casing with 9 bbls of cement. Pit lined and freeboard maintained. No E/S control issues on site. | | Cleaning out hole in prep for running 1136' of 0.231" wall 7" casing at time of inspection. Casing set: 40' - 13 3/8" 37 lb/ft, 210' - 9 5/8" 26 lb/ft in 229' of 12 1/4" hole; cement basket set at 120'. On 12/08/10 cemented 9 5/8" with 90 sacks of "A" containing 3% CACL2 & 1/2# flake (yield=1.18 cu ft/sk). Pumping of cement completed at 11:11. Grouted backside of 9 5/8" casing with 9 bbls of cement. Pit lined and freeboard maintained. No E/S control issues on site. | ||
+ | | | ||
+ | | | ||
| | | | ||
|- | |- | ||
Line 144: | Line 181: | ||
No E/S control issues on site. | No E/S control issues on site. | ||
+ | | | ||
+ | | | ||
| | | | ||
|- | |- | ||
Line 154: | Line 193: | ||
+ | | | ||
+ | | | ||
| | | | ||
|- | |- | ||
Line 166: | Line 207: | ||
E/S controls in place and functioning as per available plan. | E/S controls in place and functioning as per available plan. | ||
+ | | | ||
+ | | | ||
| | | | ||
|- | |- | ||
Line 176: | Line 219: | ||
+ | | | ||
+ | | | ||
| | | | ||
|- | |- | ||
Line 181: | Line 226: | ||
| 2203315 | | 2203315 | ||
| 2013-09-05 | | 2013-09-05 | ||
− | |||
− | |||
| No Violations Noted | | No Violations Noted | ||
+ | | Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|} | |} | ||
− | ==References== | + | For data sources see<ref>{{cite web |
− | {{ | + | | title = Oil and Gas Historical Inspection Report |
− | + | | publisher = [[Pennsylvania Department of Environmental Protection]] | |
+ | | date = 2015-05-26 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections | ||
+ | | accessdate = 2015-05-27 }}</ref> | ||
+ | == References == | ||
+ | {{reflist}} | ||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
[[Category:Wells]] | [[Category:Wells]] |
Well ID: 37-005-30666 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.805791,"lon":-79.524886,"icon":""}]} |
County: Armstrong | |
Municipality: West Kittanning Borough | |
Operator Name: MDS ENERGY LTD | |
Well Pad ID: | |
Farm/Lease Name: FLYNN 1-2 | |
First Permit Date: 2010-06-10 | |
Last Permit Date: 2010-06-10 | |
Spud Date: 2010-12-07 | |
Unconventional: No | |
Horizontal: No | |
Well Status: ACTIVE | |
Violations: 0 | |
Latitude: 40.805791 | |
Longitude: -79.524886 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
2010-0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2011-0 | 11543.0 | 180.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2012-0 | 16738.0 | 347.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2013-0 | 7451.0 | 323.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2014-0 | 5421.0 | 273.0 | 0.0 | 0.0 | 0.0 | 0.0 |
For data sources see[1]
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|---|---|---|---|---|---|---|---|
2011-0 | PRODUCED FLUID | 42.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 | FLUID RECOVERY SERVICE FRANKLIN FACILITY | FRANKLIN | PA |
2012-0 | PRODUCED FLUID | 33.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 | FLUID RECOVERY SERVICE FRANKLIN FACILITY | FRANKLIN | PA |
2014-0 | PRODUCED FLUID | 46.0 | Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095443 | CREEKSIDE TREATMENT FACILITY | CREEKSIDE | PA |
For data sources see[2]
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
1933398 | 2010-12-07 | No Violations Noted | Rigging up and preparing to spud at time of inspection. Proposed TD = 3456' with casing plan as follows: As needed - 13 3/8", as needed - 9 3/8", 1156' - 0.231" wall 7". Pit not lined at time of inspection. Discussed with operator rep Randy Morris that pit wall facing Flynn tire building was falling in and needed addressed. Well has several buildings within 200'; discussed with operator rep Randy Morris that well control (BOP, flare stack, kill-fluids) should be attended to. Inspection conducted w/OGI D. Catalano. | |||
1933407 | 2010-12-09 | No Violations Noted | Cleaning out hole in prep for running 1136' of 0.231" wall 7" casing at time of inspection. Casing set: 40' - 13 3/8" 37 lb/ft, 210' - 9 5/8" 26 lb/ft in 229' of 12 1/4" hole; cement basket set at 120'. On 12/08/10 cemented 9 5/8" with 90 sacks of "A" containing 3% CACL2 & 1/2# flake (yield=1.18 cu ft/sk). Pumping of cement completed at 11:11. Grouted backside of 9 5/8" casing with 9 bbls of cement. Pit lined and freeboard maintained. No E/S control issues on site. | |||
1937681 | 2010-12-15 | No Violations Noted | Well shut-in on 7" x 2" swage.
Pit lined and freeboard maintained. No E/S control issues on site. |
|||
1939573 | 2010-12-21 | No Violations Noted | Well Drilled. Not equipped for production. Site ID sign and E&S plan located. Pit on-site / appears to be in sound condition. There are no signs of erosion or sedimentation on the well site or access road.
|
|||
1943086 | 2011-01-11 | No Violations Noted | Well shut in on 2" tubing.
Rods installed. Pump jack not yet installed. 7" x 2" annulus closed. Drilling pit lined and freeboard maintained. E/S controls in place and functioning as per available plan. |
|||
1949884 | 2011-02-08 | No Violations Noted | Well Drilled. Not equipped for production. Site ID sign and E&S plan located. Site has been re-graded. There are 4 roll-off boxes still on-site. There are no signs of erosion or sedimentation.
|
|||
2203315 | 2013-09-05 | No Violations Noted | Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. |
For data sources see[3]