| Well ID: 37-111-20229 | | Well ID: 37-111-20229 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 40.09983, -78.989836 | width=100% | height=100% }} |
+ | |- | ||
+ | | County: [[Somerset County, Pennsylvania|Somerset]] | ||
+ | |- | ||
+ | | Municipality: [[Quemahoning Township, Somerset County, Pennsylvania|Quemahoning Township]] | ||
|- | |- | ||
| Operator Name: [[MID EAST OIL CO]] | | Operator Name: [[MID EAST OIL CO]] | ||
+ | |- | ||
+ | | Well Pad ID: | ||
+ | |- | ||
+ | | Farm/Lease Name: MCVICKER 1 | ||
|- | |- | ||
| First Permit Date: 2001-04-18 | | First Permit Date: 2001-04-18 | ||
Line 16: | Line 24: | ||
|- | |- | ||
| Horizontal: No | | Horizontal: No | ||
+ | |- | ||
+ | | Well Status: ACTIVE | ||
|- | |- | ||
| Violations: 4 | | Violations: 4 | ||
Line 43: | Line 53: | ||
|- | |- | ||
|} | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Oil and Gas Historical Production Report | ||
+ | | publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2015-05-26 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production | ||
+ | | accessdate = 2015-05-27 }}</ref> | ||
== Waste Data == | == Waste Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 55: | Line 71: | ||
!scope="col" | FACILITY STATE | !scope="col" | FACILITY STATE | ||
|} | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Oil and Gas Historical Waste Report | ||
+ | | publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2015-05-26 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste | ||
+ | | accessdate = 2015-05-26 }}</ref> | ||
== Inspection Data == | == Inspection Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 62: | Line 84: | ||
!scope="col" | COMMENT | !scope="col" | COMMENT | ||
!scope="col" | VIOLATION ID | !scope="col" | VIOLATION ID | ||
+ | !scope="col" | VIOLATION CODE | ||
+ | !scope="col" | VIOLATION_COMMENT | ||
|- | |- | ||
| 1793924 | | 1793924 | ||
| 2009-04-17 | | 2009-04-17 | ||
| Violation(s) Noted | | Violation(s) Noted | ||
− | | Based on records, well was completed on 6/6/01 to a depth of 5,720 ft. from grade and WCAR submitted and approved by DEP on 3/22/02. During inspection, no well tag was located at the well head. Well was completed with a | + | | Based on records, well was completed on 6/6/01 to a depth of 5,720 ft. from grade and WCAR submitted and approved by DEP on 3/22/02. During inspection, no well tag was located at the well head. Well was completed with a 4﾿ shut off valve assembly. Valve was located in the off position. Two pits remained open at the site with limited plastic liner remaining along the sides. Drill cuttings and fluids remain in the pit. The cut face wall of the hill side pad has collapsed into the pit. Drill casing remain at the site. E&S problems are present with the access road along with the remaining drilling pad. No filter fence remains at the site. |
| 561677 | | 561677 | ||
+ | | 201TAG - Failure to install, in a permanent manner, the permit number on a completed well | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
Line 73: | Line 99: | ||
| 2009-04-17 | | 2009-04-17 | ||
| Violation(s) Noted | | Violation(s) Noted | ||
− | | Based on records, well was completed on 6/6/01 to a depth of 5,720 ft. from grade and WCAR submitted and approved by DEP on 3/22/02. During inspection, no well tag was located at the well head. Well was completed with a | + | | Based on records, well was completed on 6/6/01 to a depth of 5,720 ft. from grade and WCAR submitted and approved by DEP on 3/22/02. During inspection, no well tag was located at the well head. Well was completed with a 4﾿ shut off valve assembly. Valve was located in the off position. Two pits remained open at the site with limited plastic liner remaining along the sides. Drill cuttings and fluids remain in the pit. The cut face wall of the hill side pad has collapsed into the pit. Drill casing remain at the site. E&S problems are present with the access road along with the remaining drilling pad. No filter fence remains at the site. |
| 561678 | | 561678 | ||
+ | | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
Line 80: | Line 108: | ||
| 2009-04-17 | | 2009-04-17 | ||
| Violation(s) Noted | | Violation(s) Noted | ||
− | | Based on records, well was completed on 6/6/01 to a depth of 5,720 ft. from grade and WCAR submitted and approved by DEP on 3/22/02. During inspection, no well tag was located at the well head. Well was completed with a | + | | Based on records, well was completed on 6/6/01 to a depth of 5,720 ft. from grade and WCAR submitted and approved by DEP on 3/22/02. During inspection, no well tag was located at the well head. Well was completed with a 4﾿ shut off valve assembly. Valve was located in the off position. Two pits remained open at the site with limited plastic liner remaining along the sides. Drill cuttings and fluids remain in the pit. The cut face wall of the hill side pad has collapsed into the pit. Drill casing remain at the site. E&S problems are present with the access road along with the remaining drilling pad. No filter fence remains at the site. |
| 561679 | | 561679 | ||
+ | | 206REST - Failure to restore site w/in 9 months of completion of drilling or plugging | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
Line 87: | Line 117: | ||
| 2009-04-17 | | 2009-04-17 | ||
| Violation(s) Noted | | Violation(s) Noted | ||
− | | Based on records, well was completed on 6/6/01 to a depth of 5,720 ft. from grade and WCAR submitted and approved by DEP on 3/22/02. During inspection, no well tag was located at the well head. Well was completed with a | + | | Based on records, well was completed on 6/6/01 to a depth of 5,720 ft. from grade and WCAR submitted and approved by DEP on 3/22/02. During inspection, no well tag was located at the well head. Well was completed with a 4﾿ shut off valve assembly. Valve was located in the off position. Two pits remained open at the site with limited plastic liner remaining along the sides. Drill cuttings and fluids remain in the pit. The cut face wall of the hill side pad has collapsed into the pit. Drill casing remain at the site. E&S problems are present with the access road along with the remaining drilling pad. No filter fence remains at the site. |
| 561680 | | 561680 | ||
+ | | 210UNPLUG - Failure to plug a well upon abandonment | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
Line 95: | Line 127: | ||
| No Violations Noted | | No Violations Noted | ||
| Met with Don Fleming to discuss the steps neccassary to restore site and plug well. It was discussed that the remaining cuttings in the pits are to be removed and landfarmed. The pit liners are to be removed and disposed of at an approved landfill. After proper disposal of the cuttings and liners the pits should be restored and temporarily seeded and mulched. Final restoration is to be completed after the well is plugged. Mid East Oil is to contact the DEP before the work begins | | Met with Don Fleming to discuss the steps neccassary to restore site and plug well. It was discussed that the remaining cuttings in the pits are to be removed and landfarmed. The pit liners are to be removed and disposed of at an approved landfill. After proper disposal of the cuttings and liners the pits should be restored and temporarily seeded and mulched. Final restoration is to be completed after the well is plugged. Mid East Oil is to contact the DEP before the work begins | ||
+ | | | ||
+ | | | ||
| | | | ||
|- | |- | ||
Line 102: | Line 136: | ||
| No Violations Noted | | No Violations Noted | ||
| Revisited the site to evaluate progress of site restoration. There is no progress to the site at the time of the inspection. Mid East Oil is to contact the WQS at 724-925-5426 before the work begins. | | Revisited the site to evaluate progress of site restoration. There is no progress to the site at the time of the inspection. Mid East Oil is to contact the WQS at 724-925-5426 before the work begins. | ||
+ | | | ||
+ | | | ||
| | | | ||
|- | |- | ||
Line 109: | Line 145: | ||
| Outstanding Violations - No Viols Req'd | | Outstanding Violations - No Viols Req'd | ||
| During inspection, no well tag was located at the well head. Two pits remained open at the site with limited plastic liner remaining along the sides. Drill cuttings and fluids remain in the pit. The cut face wall of the hill side pad has collapsed into the pit. Drill casing remain at the site. E&S problems are present with the access road along with the remaining drilling pad. No filter fence remains at the site. | | During inspection, no well tag was located at the well head. Two pits remained open at the site with limited plastic liner remaining along the sides. Drill cuttings and fluids remain in the pit. The cut face wall of the hill side pad has collapsed into the pit. Drill casing remain at the site. E&S problems are present with the access road along with the remaining drilling pad. No filter fence remains at the site. | ||
+ | | | ||
+ | | | ||
| | | | ||
|- | |- | ||
|} | |} | ||
− | ==References== | + | For data sources see<ref>{{cite web |
− | {{ | + | | title = Oil and Gas Historical Inspection Report |
− | + | | publisher = [[Pennsylvania Department of Environmental Protection]] | |
+ | | date = 2015-05-26 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections | ||
+ | | accessdate = 2015-05-27 }}</ref> | ||
+ | == References == | ||
+ | {{reflist}} | ||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
[[Category:Wells]] | [[Category:Wells]] |
Well ID: 37-111-20229 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.09983,"lon":-78.989836,"icon":""}]} |
County: Somerset | |
Municipality: Quemahoning Township | |
Operator Name: MID EAST OIL CO | |
Well Pad ID: | |
Farm/Lease Name: MCVICKER 1 | |
First Permit Date: 2001-04-18 | |
Last Permit Date: 2001-04-18 | |
Spud Date: 2001-05-30 | |
Unconventional: No | |
Horizontal: No | |
Well Status: ACTIVE | |
Violations: 4 | |
Latitude: 40.09983 | |
Longitude: -78.989836 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
2006-0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
For data sources see[1]
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|
For data sources see[2]
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
1793924 | 2009-04-17 | Violation(s) Noted | Based on records, well was completed on 6/6/01 to a depth of 5,720 ft. from grade and WCAR submitted and approved by DEP on 3/22/02. During inspection, no well tag was located at the well head. Well was completed with a 4﾿ shut off valve assembly. Valve was located in the off position. Two pits remained open at the site with limited plastic liner remaining along the sides. Drill cuttings and fluids remain in the pit. The cut face wall of the hill side pad has collapsed into the pit. Drill casing remain at the site. E&S problems are present with the access road along with the remaining drilling pad. No filter fence remains at the site. | 561677 | 201TAG - Failure to install, in a permanent manner, the permit number on a completed well | |
1793924 | 2009-04-17 | Violation(s) Noted | Based on records, well was completed on 6/6/01 to a depth of 5,720 ft. from grade and WCAR submitted and approved by DEP on 3/22/02. During inspection, no well tag was located at the well head. Well was completed with a 4﾿ shut off valve assembly. Valve was located in the off position. Two pits remained open at the site with limited plastic liner remaining along the sides. Drill cuttings and fluids remain in the pit. The cut face wall of the hill side pad has collapsed into the pit. Drill casing remain at the site. E&S problems are present with the access road along with the remaining drilling pad. No filter fence remains at the site. | 561678 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | |
1793924 | 2009-04-17 | Violation(s) Noted | Based on records, well was completed on 6/6/01 to a depth of 5,720 ft. from grade and WCAR submitted and approved by DEP on 3/22/02. During inspection, no well tag was located at the well head. Well was completed with a 4﾿ shut off valve assembly. Valve was located in the off position. Two pits remained open at the site with limited plastic liner remaining along the sides. Drill cuttings and fluids remain in the pit. The cut face wall of the hill side pad has collapsed into the pit. Drill casing remain at the site. E&S problems are present with the access road along with the remaining drilling pad. No filter fence remains at the site. | 561679 | 206REST - Failure to restore site w/in 9 months of completion of drilling or plugging | |
1793924 | 2009-04-17 | Violation(s) Noted | Based on records, well was completed on 6/6/01 to a depth of 5,720 ft. from grade and WCAR submitted and approved by DEP on 3/22/02. During inspection, no well tag was located at the well head. Well was completed with a 4﾿ shut off valve assembly. Valve was located in the off position. Two pits remained open at the site with limited plastic liner remaining along the sides. Drill cuttings and fluids remain in the pit. The cut face wall of the hill side pad has collapsed into the pit. Drill casing remain at the site. E&S problems are present with the access road along with the remaining drilling pad. No filter fence remains at the site. | 561680 | 210UNPLUG - Failure to plug a well upon abandonment | |
1818757 | 2009-08-04 | No Violations Noted | Met with Don Fleming to discuss the steps neccassary to restore site and plug well. It was discussed that the remaining cuttings in the pits are to be removed and landfarmed. The pit liners are to be removed and disposed of at an approved landfill. After proper disposal of the cuttings and liners the pits should be restored and temporarily seeded and mulched. Final restoration is to be completed after the well is plugged. Mid East Oil is to contact the DEP before the work begins | |||
1827103 | 2009-09-09 | No Violations Noted | Revisited the site to evaluate progress of site restoration. There is no progress to the site at the time of the inspection. Mid East Oil is to contact the WQS at 724-925-5426 before the work begins. | |||
1889698 | 2010-06-04 | Outstanding Violations - No Viols Req'd | During inspection, no well tag was located at the well head. Two pits remained open at the site with limited plastic liner remaining along the sides. Drill cuttings and fluids remain in the pit. The cut face wall of the hill side pad has collapsed into the pit. Drill casing remain at the site. E&S problems are present with the access road along with the remaining drilling pad. No filter fence remains at the site. |
For data sources see[3]