X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-015-22535"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-015-22535
 
| Well ID: 37-015-22535
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.956477, -76.165125 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="14" | {{#display_map: 41.956478, -76.165125 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Bradford County, Pennsylvania|Bradford]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[Warren Township, Bradford County, Pennsylvania|Warren Township]]
+
| State: Pennsylvania
 
|-
 
|-
| Operator Name: [[TALISMAN ENERGY USA INC]]
+
| County: [[Bradford_County,_Pennsylvania|Bradford]]
 
|-
 
|-
| Well Pad ID: [[147691|147691]]
+
| Municipality: [[Warren Township,_Bradford_County,_Pennsylvania|Warren Township]]
 
|-
 
|-
| Farm/Lease Name: ABELL LIVING TRUST 05 082 03 3H
+
| Operator Name: [[REPSOL OIL & GAS USA LLC]]
 
|-
 
|-
| First Permit Date: 2013-02-28
+
| Well Pad ID: [[147691]]
 
|-
 
|-
| Last Permit Date: 2013-02-28
+
| Farm/Lease Name: ABELL LIVING TRUST 05 082 03 3H
 
|-
 
|-
| Spud Date: 2013-05-20
+
| License Status: Active
 
|-
 
|-
| Unconventional: Yes
+
| Spud Date: 05/20/2013
 
|-
 
|-
| Horizontal: Yes
+
| Permit Date: 2/28/2013
 
|-
 
|-
| Well Status: ACTIVE
+
| Unconventional Well: Y
 
|-
 
|-
| Violations: 0
+
| Configuration: Horizontal Well
 
|-
 
|-
| Latitude: 41.956477
+
| Latitude: 41.956478
 
|-
 
|-
 
| Longitude: -76.165125
 
| Longitude: -76.165125
|-
 
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | GAS QUANTITY
+
!scope="col" | Operator Name
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Gas Quantity (mcf)
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Gas Production Days
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Oil Quantity (bbl)
!scope="col" | OIL QUANTITY
+
!scope="col" | Oil Production Days
!scope="col" | OIL PRODUCTION DAYS
+
!scope="col" | Water Quantity (bbl)
|-
+
!scope="col" | Water Production Days
| 2013-1
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2013
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2013-2
+
| 2014
| style="text-align:right;" | 0.0
+
| [[REPSOL OIL & GAS USA LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 490,417.90
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 188
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2015
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| style="text-align: right;" | 510,097.20
 +
| style="text-align: right;" | 362
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2014-1
+
| 2016
| style="text-align:right;" | 38818.3
+
| [[REPSOL OIL & GAS USA LLC]]
| style="text-align:right;" | 9.0
+
| style="text-align: right;" | 350,155.80
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 358
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2017
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| style="text-align: right;" | 266,320.20
 +
| style="text-align: right;" | 364
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2014-2
+
| 2018
| style="text-align:right;" | 451599.6
+
| [[REPSOL OIL & GAS USA LLC]]
| style="text-align:right;" | 179.0
+
| style="text-align: right;" | 243,715.50
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 363
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
|-
+
| 2019
| 2015-02
+
| [[REPSOL OIL & GAS USA LLC]]
| style="text-align:right;" | 49121.0
+
| style="text-align: right;" | 49,995.10
| style="text-align:right;" | 28.0
+
| style="text-align: right;" | 90
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
|-
 
|-
 
| 2015-01
 
| style="text-align:right;" | 57504.9
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-03
 
| style="text-align:right;" | 51458.0
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Production Report
+
  | title =Oil and Gas Production Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-27 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
 
== Waste Data ==
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | TYPE
+
!scope="col" | Waste Type
!scope="col" | QUANTITY
+
!scope="col" | Quantity
!scope="col" | UNITS
+
!scope="col" | Disposal Method
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Waste Facility ID
!scope="col" | WASTE FACILITY PERMIT ID
 
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
 
| 2013-1
 
| 2013-1
| DRILL CUTTINGS
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 219.65
+
| style="text-align: right;" | 219.65 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
 
| 8-0728-0004/013
 
| 8-0728-0004/013
| CHEMUNG COUNTY LANDFILL
 
| LOWMAN
 
| NY
 
|-
 
 
|-
 
|-
 
| 2013-1
 
| 2013-1
| DRILL CUTTINGS
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 113.27
+
| style="text-align: right;" | 113.27 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
 
| 8-4630-00010/00
 
| 8-4630-00010/00
| HAKES C&D LANDFILL
 
| PAINTED POST
 
| NY
 
|-
 
 
|-
 
|-
 
| 2014-1
 
| 2014-1
| FRACING FLUID WASTE
+
| Fracing Fluid Waste (in Barrels)
| style="text-align:right;" | 10.0
+
| style="text-align: right;" | 10,760.38 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2014-1
 
| 2014-1
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 22.45
+
| style="text-align: right;" | 22.45 Bbl
| Bbl
 
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| WMGR0123
+
| WMGR123
| HYDRO RECOVERY LP BLOSSBURG FACILITY
 
| BLOSSBURG
 
| PA
 
|-
 
 
|-
 
|-
 
| 2014-1
 
| 2014-1
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 153.01
+
| style="text-align: right;" | 153.01 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2014-2
 
| 2014-2
| FRACING FLUID WASTE
+
| Fracing Fluid Waste (in Barrels)
| style="text-align:right;" | 2.0
+
| style="text-align: right;" | 2,604.80 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
|
 
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
 
|
 
 
|  
 
|  
 
|-
 
|-
 +
| 2014-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 534.54 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123
 
|-
 
|-
 
| 2014-2
 
| 2014-2
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 189.57
+
| style="text-align: right;" | 189.57 Bbl
| Bbl
 
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| WMGR123NC010
 
| WMGR123NC010
| HYDRO RECOVERY LP ANTRIM FACILITY
 
| WELLSBORO
 
| PA
 
 
|-
 
|-
 +
| 2014-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 31.20 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123SW018
 
|-
 
|-
 
| 2014-2
 
| 2014-2
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 534.54
+
| style="text-align: right;" | 6,650.35 Bbl
| Bbl
+
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2015-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 348.04 Bbl
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| WMGR0123
+
| WMGR123
| HYDRO RECOVERY LP BLOSSBURG FACILITY
 
| BLOSSBURG
 
| PA
 
 
|-
 
|-
 +
| 2015-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 377.08 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC010
 
|-
 
|-
| 2014-2
+
| 2015-1
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 6.0
+
| style="text-align: right;" | 1,274.83 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2015-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 285.20 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123
 +
|-
 +
| 2015-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 427.46 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC010
 +
|-
 +
| 2015-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 433.20 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2016-1
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.76 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC010
 +
|-
 +
| 2016-1
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 742.53 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
 +
| 2016-2
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 15.86 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123
 +
|-
 +
| 2016-2
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 117.49 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 
|-
 
|-
| 2014-2
+
| 2016-2
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 31.2
+
| style="text-align: right;" | 460.57 Bbl
| Bbl
+
| REUSE OTHER THAN ROAD SPREADING
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
+
|  
| WMGR123D001X
 
| TERRAQUA RESOURCE MANAGEMENT
 
| WILLIAMSPORT
 
| PA
 
 
|-
 
|-
|}
+
| 2017-01
For data sources see<ref>{{cite web
+
| Produced Fluid (in Barrels) RWC 802
| title = Oil and Gas Historical Waste Report
+
| style="text-align: right;" | 12.40 Bbl
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| RESIDUAL WASTE PROCESSING FACILITY
| date = 2015-05-26
+
| WMGR123NC010
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste
 
| accessdate = 2015-05-26 }}</ref>
 
== Inspection Data ==
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | INSPECTION ID
 
!scope="col" | DATE
 
!scope="col" | DESCRIPTION
 
!scope="col" | COMMENT
 
!scope="col" | VIOLATION ID
 
!scope="col" | VIOLATION CODE
 
!scope="col" | VIOLATION_COMMENT
 
 
|-
 
|-
| 2156000
+
| 2017-01
| 2013-04-10
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 102.50 Bbl
| Cond is set, but covered w/ plastic.
+
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 79.56 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 67.88 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2017-04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 53.53 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 
|-
 
|-
| 2163324
+
| 2017-04
| 2013-05-01
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 26.76 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 12.99 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 +
|-
 +
| 2017-05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 12.99 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 93.98 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 25.30 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2017-08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 37.71 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2184254
+
| 2017-09
| 2013-07-15
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 38.93 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 49.16 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 120.52 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 63.20 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
|}
+
| 2018-01
For data sources see<ref>{{cite web
+
| Produced Fluid (in Barrels) RWC 802
| title = Oil and Gas Historical Inspection Report
+
| style="text-align: right;" | 49.61 Bbl
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| REUSE (AT WELL PAD)
| date = 2015-05-26
+
|  
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections
 
| accessdate = 2015-05-27 }}</ref>
 
[[Category:Has Chemical Data]]
 
==Chemical Data==
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | HF Fluid Concentration
 
!scope="col" | Ingredient
 
!scope="col" | Additive Concentration
 
!scope="col" | Trade Name
 
!scope="col" | Purpose
 
!scope="col" | CAS number
 
!scope="col" | Supplier
 
 
|-
 
|-
| 7.10669
+
| 2018-02
| Crystalline silica: Quartz (SiO2)
+
| Produced Fluid (in Barrels) RWC 802
| 100.0
+
| style="text-align: right;" | 33.61 Bbl
| 100 Mesh
+
| RESIDUAL WASTE PROCESSING FACILITY
| Trican
+
| WMGR123NC010
| 14808-60-7
 
|  Bulk (over 20K lbs)*
 
 
|-
 
|-
 +
| 2018-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 48.89 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 
|-
 
|-
| 8.02868
+
| 2018-03
| Crystalline silica: Quartz (SiO2)
+
| Produced Fluid (in Barrels) RWC 802
| 100.0
+
| style="text-align: right;" | 16.30 Bbl
| White 40/70
+
| REUSE (AT WELL PAD)
| Proppant
+
|  
| 14808-60-7
 
| Trican
 
 
|-
 
|-
 +
| 2018-04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 15.81 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 
|-
 
|-
| 0.0
+
| 2018-04
| Isopropanol
+
| Produced Fluid (in Barrels) RWC 802
| 0.0
+
| style="text-align: right;" | 16.60 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
| Other Chemicals
+
|-
| 67-63-0
+
| 2018-05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 86.60 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2018-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 78.26 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 0.0
+
| 2018-07
| Sorbitol Tetraoleate
+
| Produced Fluid (in Barrels) RWC 802
| 0.0
+
| style="text-align: right;" | 45.32 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
| Other Chemicals
+
|-
| 61723-83-9
+
| 2018-08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 7.22 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
|-
+
| 2018-09
| 0.0
+
| Produced Fluid (in Barrels) RWC 802
| Ammonium Acrylate
+
| style="text-align: right;" | 58.09 Bbl
| 0.0
+
| REUSE (AT WELL PAD)
|  
 
| Other Chemicals
 
| 10604-69-0
 
 
|  
 
|  
 
|-
 
|-
 +
| 2018-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 30.95 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 
|-
 
|-
| 0.0
+
| 2018-10
| Polyethylene glycol monooleate
+
| Produced Fluid (in Barrels) RWC 802
| 0.0
+
| style="text-align: right;" | 30.34 Bbl
|
+
| REUSE (AT WELL PAD)
| Other Chemicals
 
| 9004-96-0
 
 
|  
 
|  
 
|-
 
|-
 +
| 2018-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 45.41 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 
|-
 
|-
| 0.0
+
| 2018-12
| Trade Secret
+
| Produced Fluid (in Barrels) RWC 802
| 0.0
+
| style="text-align: right;" | 108.24 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
| Other Chemicals
+
|-
| Proprietary
+
| 2019-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 60.58 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2019-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 68.24 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 +
|-
 +
| 2019-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.24 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 
|-
 
|-
| 0.0
+
|}
| Nonionic Surfactant
+
For data sources see<ref>{{cite web
| 0.0
+
| title =Oil and Gas Waste Reports
|  
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| Other Chemicals
+
| date = 2019-03-31
| Proprietary
+
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
|  
+
| accessdate = 2019-05-21 }}</ref>
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Inspection Category
 +
!scope="col" | Inspection Date
 +
!scope="col" | Inspection Type
 +
!scope="col" | Inspection Result
 +
!scope="col" | Inspection Comments
 
|-
 
|-
 +
| 2156000
 +
| Primary Facility
 +
| 04/10/2013
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| Cond is set, but covered w/ plastic.
 
|-
 
|-
| 0.0
+
| 2163324
| Acrylamide P/W acrylic acid ammonium salt
+
| Primary Facility
| 0.0
+
| 05/01/2013
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 
|  
 
|  
| Other Chemicals
+
|-
| 26100-47-0
+
| 2184254
 +
| Primary Facility
 +
| 07/15/2013
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 
|  
 
|  
 
|-
 
|-
 +
| 2279074
 +
| Primary Facility
 +
| 06/11/2014
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|
 
|-
 
|-
| 0.0
+
| 2296656
| Water
+
| Primary Facility
| 0.0
+
| 08/14/2014
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 
|  
 
|  
| Other Chemicals
+
|-
| 7732-18-5
+
| 2486399
 +
| Primary Facility
 +
| 2016-05-19
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 
|  
 
|  
 
|-
 
|-
 +
| 2603365
 +
| Primary Facility
 +
| 2017-06-09
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| On June 9, 2017, at 1120 hrs., the Department conducted a routine inspection at the Repsol Oil & Gas USA LLC, Abell Living Trust (05-082) Well Site in Warren Township, Bradford County.  Andrew Hobbins, Water Quality Specialist, represented the Department.  Nobody was present for Repsol. 
 +
 +
The site sign, E & S plan and weekly inspection logs were on site and available for review.  The site was well vegetated and no erosion issues were observed.  Two PCSM bioretention basins were installed at the site.
 +
 +
Five wells were in production phase during the inspection.  The wells were all labeled and no bubbling was observed in the well cellar.  Two production tanks and four GPUs were also on site.  The tanks and GPUs were on secondary containment.  Puddles on the well pad surface were low in specific conductivity measuring less than 300 uS/cm.  No staining was observed on the well pad surface.
 +
 +
The Department left the site at 1220 hrs.  No violations were observed.
 
|-
 
|-
| 0.0
+
| 2799564
| Acrylamide
+
| Primary Facility
| 0.0
+
| 2018-11-06
|  
+
| Site Restoration
| Other Chemicals
+
| No Violations Noted
| 79-06-1
+
| NOT approval.
|
+
Electrical conductivity readings taken from pooled water on site with an Oakton PCSTestr 35.  A puddle near the production tanks is 0.09 mS/cm today.  JLP
 
|-
 
|-
 +
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 
|-
 
|-
| 0.0
+
|}-->
| Sorbitan monooleate
+
<!--==== Penalties Applied ====
| 0.0
+
{| class="wikitable sortable" width="95%"
|  
+
!scope="col" | Violation ID
| Other Chemicals
+
!scope="col" | Penalty ID
| 1338-43-8
+
!scope="col" | Penalty Code
|  
+
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 
|-
 
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
|-
| 0.0
+
| 1
| Alkyloxypolyethylene oxyethanol
+
| 06/03/2014
| 0.0
+
| 06/03/2014
|  
+
| style="text-align: right;" | 5749
| Other Chemicals
+
| style="text-align: right;" | 3,971,880.0
| 84133-50-6
+
| style="text-align: right;" | 30000
|  
 
 
|-
 
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 
|-
 
|-
| 5.0
+
|- valign="top"
| 2
+
| rowspan="31"| 1
| 10222.0
+
| rowspan="4"| FR-8
| AQUCAR DB 5 (Water Treatment Microbiocide)
+
| rowspan="4"| Trican
| Biocide
+
| rowspan="4"| Friction Reducer
| 2-dibromo-3-nitrilop
+
| Ammonium Chloride
| Trican
+
| 12125-02-9
 +
| style="text-align: right;" | 1.5
 +
| style="text-align: right;" | 0.001027
 +
| style="text-align: right;" | 429.156
 
|-
 
|-
 +
| Petroleum distillates, dewaxed heavy paraffinic
 +
| 64742-65-0
 +
| style="text-align: right;" | 8
 +
| style="text-align: right;" | 0.005476
 +
| style="text-align: right;" | 2288.83
 
|-
 
|-
| 0.000133
+
| Petroleum distillates, hydrotreated heavy paraffinic
| Dibromoacetonitrile
+
| 64742-54-7
| 0.5
+
| style="text-align: right;" | 8
| AQUCAR DB 5 (Water Treatment Microbiocide)
+
| style="text-align: right;" | 0.005476
| Biocide
+
| style="text-align: right;" | 2288.83
| 3252-43-5
 
| Trican
 
 
|-
 
|-
 +
| Mineral oil/ light hydrotreated pet. distillate
 +
| 64742-47-8
 +
| style="text-align: right;" | 28
 +
| style="text-align: right;" | 0.019165
 +
| style="text-align: right;" | 8010.91
 
|-
 
|-
| 0.000398
+
|- valign="top"
| Sodium Bromide
+
| rowspan="2"| LSI-21 (Scale Inhibitor)
| 1.5
+
| rowspan="2"| Trican
| AQUCAR DB 5 (Water Treatment Microbiocide)
+
| rowspan="2"| Scale Inhibitor
| Biocide
+
| Acrylic Polymer
| 7647-15-6
+
| 28205-96-1
| Trican
+
| style="text-align: right;" | 15
 +
| style="text-align: right;" | 0.003842
 +
| style="text-align: right;" | 1605.99
 
|-
 
|-
 +
| Sodium Salt of Phosphate Ester
 +
| 68131-72-6
 +
| style="text-align: right;" | 15
 +
| style="text-align: right;" | 0.003842
 +
| style="text-align: right;" | 1605.99
 
|-
 
|-
| 0.017316
+
|- valign="top"
| Polyethylene glycol
+
| rowspan="1"| White 40/70
| 65.2
+
| rowspan="1"| Trican
| AQUCAR DB 5 (Water Treatment Microbiocide)
+
| rowspan="1"| Proppant
| Biocide
+
| Crystalline silica: Quartz (SiO2)
| 25322-68-3
+
| 14808-60-7
| Trican
+
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 8.02868
 +
| style="text-align: right;" | 3,355,880.0
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="2"| FEAC-20 (Iron Control)
 +
| rowspan="2"| Trican
 +
| rowspan="2"| Iron Control
 +
| Acetic acid
 +
| 64-19-7
 +
| style="text-align: right;" | 45
 +
| style="text-align: right;" | 0.001611
 +
| style="text-align: right;" | 673.576
 
|-
 
|-
| 0.012424
+
| Citric acid
| Hydrochloric acid
+
| 77-92-9
| 7.5
+
| style="text-align: right;" | 30
| 7 1/2% HCL
+
| style="text-align: right;" | 0.001074
| Carrier
+
| style="text-align: right;" | 449.05
| 7647-01-0
 
| Trican
 
|-
 
 
|-
 
|-
| 4.83255
+
|- valign="top"
 +
| rowspan="1"| 100 Mesh, Bulk (over 20K lbs)*
 +
| rowspan="1"| Trican
 +
| rowspan="1"| Proppant
 
| Crystalline silica: Quartz (SiO2)
 
| Crystalline silica: Quartz (SiO2)
| 100.0
 
| White 30/50
 
| Proppant
 
 
| 14808-60-7
 
| 14808-60-7
| Trican
+
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 7.10669
 +
| style="text-align: right;" | 2,970,500.0
 +
|-
 +
|- valign="top"
 +
| rowspan="12"|
 +
| rowspan="12"|
 +
| rowspan="12"| Other Chemicals
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| Alkyloxypolyethylene oxyethanol
 +
| 84133-50-6
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 1.5e-05
+
| Trade Secret
| Prop-2-yn-1-ol
+
| Proprietary
| 1.0
+
| style="text-align: right;" | 0
| AI-7NR (Acid Inhibitor)
+
| style="text-align: right;" | 0
| Acid Inhibitor
+
| style="text-align: right;" | 0
| 107-19-7
 
| Trican
 
 
|-
 
|-
 +
| Ammonium Acrylate
 +
| 10604-69-0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.015374
+
| Acrylamide P/W acrylic acid ammonium salt
| Hydrochloric acid
+
| 26100-47-0
| 3.5
+
| style="text-align: right;" | 0
| 3 1/2% HCL
+
| style="text-align: right;" | 0
| Carrier
+
| style="text-align: right;" | 0
| 7647-01-0
 
| Trican
 
 
|-
 
|-
 +
| Nonionic Surfactant
 +
| Proprietary
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 8.0
+
| Anionic polyacrylamide copolymer
| Petroleum distillates
+
| Proprietary
| 64742.0
+
| style="text-align: right;" | 0
| FR-8
+
| style="text-align: right;" | 0
| Friction Reducer
+
| style="text-align: right;" | 0
| hydrotreated heavy
 
| Trican
 
 
|-
 
|-
 +
| Sorbitol Tetraoleate
 +
| 61723-83-9
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.001027
+
| Isopropanol
| Ammonium Chloride
+
| 67-63-0
| 1.5
+
| style="text-align: right;" | 0
| FR-8
+
| style="text-align: right;" | 0
| Friction Reducer
+
| style="text-align: right;" | 0
| 12125-02-9
 
| Trican
 
 
|-
 
|-
 +
| Acrylamide
 +
| 79-06-1
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.019165
+
| Polyethylene glycol monooleate
| Mineral oil/ light hydrotreated pet. distillate
+
| 9004-96-0
| 28.0
+
| style="text-align: right;" | 0
| FR-8
+
| style="text-align: right;" | 0
| Friction Reducer
+
| style="text-align: right;" | 0
| 64742-47-8
 
| Trican
 
 
|-
 
|-
 +
| Sorbitan monooleate
 +
| 1338-43-8
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 8.0
+
|- valign="top"
| Petroleum distillates
+
| rowspan="1"| 7 1/2% HCL
| 64742.0
+
| rowspan="1"| Trican
| FR-8
+
| rowspan="1"| Carrier
| Friction Reducer
+
| Hydrochloric acid
| dewaxed heavy paraf
+
| 7647-01-0
| Trican
+
| style="text-align: right;" | 7.5
 +
| style="text-align: right;" | 0.012424
 +
| style="text-align: right;" | 5193.04
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| 3 1/2% HCL
 +
| rowspan="1"| Trican
 +
| rowspan="1"| Carrier
 +
| Hydrochloric acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 3.5
 +
| style="text-align: right;" | 0.015374
 +
| style="text-align: right;" | 6425.96
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| AI-7NR (Acid Inhibitor)
 +
| rowspan="1"| Trican
 +
| rowspan="1"| Acid Inhibitor
 +
| Prop-2-yn-1-ol
 +
| 107-19-7
 +
| style="text-align: right;" | 1
 +
| style="text-align: right;" | 0.00001500
 +
| style="text-align: right;" | 6.34252
 
|-
 
|-
| 0.003842
+
|- valign="top"
| Acrylic Polymer
+
| rowspan="4"| AQUCAR DB 5 (Water Treatment Microbiocide)
| 15.0
+
| rowspan="4"| Trican
| LSI-21 (Scale Inhibitor)
+
| rowspan="4"| Biocide
| Scale Inhibitor
+
| Sodium Bromide
| 28205-96-1
+
| 7647-15-6
| Trican
+
| style="text-align: right;" | 1.5
 +
| style="text-align: right;" | 0.000398
 +
| style="text-align: right;" | 166.514
 
|-
 
|-
 +
| Polyethylene glycol
 +
| 25322-68-3
 +
| style="text-align: right;" | 65.2
 +
| style="text-align: right;" | 0.017316
 +
| style="text-align: right;" | 7237.79
 
|-
 
|-
| 0.003842
+
| Dibromoacetonitrile
| Sodium Salt of Phosphate Ester
+
| 3252-43-5
| 15.0
+
| style="text-align: right;" | 0.5
| LSI-21 (Scale Inhibitor)
+
| style="text-align: right;" | 0.000133
| Scale Inhibitor
+
| style="text-align: right;" | 55.5045
| 68131-72-6
 
| Trican
 
 
|-
 
|-
 +
| 2,2-dibromo-3-nitrilopropionamide
 +
| 10222-01-2
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.001328
 +
| style="text-align: right;" | 555.045
 
|-
 
|-
| 79.3015
+
|- valign="top"
| Water
+
| rowspan="1"| Water
| 100.0
+
| rowspan="1"| Customer
 +
| rowspan="1"| Carrier
 
| Water
 
| Water
| Carrier
 
 
| 7732-18-5
 
| 7732-18-5
| Customer
+
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 79.3015
 +
| style="text-align: right;" | 33,146,900.0
 
|-
 
|-
|-
+
|- valign="top"
| 0.001611
+
| rowspan="1"| White 30/50
| Acetic acid
+
| rowspan="1"| Trican
| 45.0
+
| rowspan="1"| Proppant
| FEAC-20 (Iron Control)
+
| Crystalline silica: Quartz (SiO2)
| Iron Control
+
| 14808-60-7
| 64-19-7
+
| style="text-align: right;" | 100
| Trican
+
| style="text-align: right;" | 4.83255
 +
| style="text-align: right;" | 2,019,940.0
 
|-
 
|-
 
|}
 
|}
For data sources see<ref>{{cite web | title = FracFocus Chemical Disclosure Registry |publisher = [http://www.fracfocusdata.org/DisclosureSearch/]| date = 2015-08-10 | url = http://wellwiki.org/wiki/Well_Chemicals_Data_Sources | accessdate = 2015-08-10 }}</ref>
+
For data sources see<ref>{{cite web
== References ==
+
| title =FracFocus Fracking Chemicals Database
{{reflist}}
+
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 +
==References==
 +
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Revision as of 22:21, 13 July 2019

Well Details

Well ID: 37-015-22535
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Warren Township
Operator Name: REPSOL OIL & GAS USA LLC
Well Pad ID: 147691
Farm/Lease Name: ABELL LIVING TRUST 05 082 03 3H
License Status: Active
Spud Date: 05/20/2013
Permit Date: 2/28/2013
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.956478
Longitude: -76.165125

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2014 REPSOL OIL & GAS USA LLC 490,417.90 188 0.00 0 0.00 0
2015 REPSOL OIL & GAS USA LLC 510,097.20 362 0.00 0 0.00 0
2016 REPSOL OIL & GAS USA LLC 350,155.80 358 0.00 0 0.00 0
2017 REPSOL OIL & GAS USA LLC 266,320.20 364 0.00 0 0.00 0
2018 REPSOL OIL & GAS USA LLC 243,715.50 363 0.00 0 0.00 0
2019 REPSOL OIL & GAS USA LLC 49,995.10 90 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2013-1 Drill Cuttings (in Tons) 219.65 Tons LANDFILL 8-0728-0004/013
2013-1 Drill Cuttings (in Tons) 113.27 Tons LANDFILL 8-4630-00010/00
2014-1 Fracing Fluid Waste (in Barrels) 10,760.38 Bbl REUSE OTHER THAN ROAD SPREADING
2014-1 Produced Fluid (in Barrels) 22.45 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014-1 Produced Fluid (in Barrels) 153.01 Bbl REUSE OTHER THAN ROAD SPREADING
2014-2 Fracing Fluid Waste (in Barrels) 2,604.80 Bbl REUSE OTHER THAN ROAD SPREADING
2014-2 Produced Fluid (in Barrels) 534.54 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014-2 Produced Fluid (in Barrels) 189.57 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014-2 Produced Fluid (in Barrels) 31.20 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2014-2 Produced Fluid (in Barrels) 6,650.35 Bbl REUSE OTHER THAN ROAD SPREADING
2015-1 Produced Fluid (in Barrels) 348.04 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015-1 Produced Fluid (in Barrels) 377.08 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015-1 Produced Fluid (in Barrels) 1,274.83 Bbl REUSE OTHER THAN ROAD SPREADING
2015-2 Produced Fluid (in Barrels) 285.20 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015-2 Produced Fluid (in Barrels) 427.46 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015-2 Produced Fluid (in Barrels) 433.20 Bbl REUSE OTHER THAN ROAD SPREADING
2016-1 Produced Fluid (in Barrels) RWC 802 13.76 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016-1 Produced Fluid (in Barrels) RWC 802 742.53 Bbl REUSE OTHER THAN ROAD SPREADING
2016-2 Produced Fluid (in Barrels) RWC 802 15.86 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2016-2 Produced Fluid (in Barrels) RWC 802 117.49 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2016-2 Produced Fluid (in Barrels) RWC 802 460.57 Bbl REUSE OTHER THAN ROAD SPREADING
2017-01 Produced Fluid (in Barrels) RWC 802 12.40 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017-01 Produced Fluid (in Barrels) RWC 802 102.50 Bbl REUSE (AT WELL PAD)
2017-02 Produced Fluid (in Barrels) RWC 802 79.56 Bbl REUSE (AT WELL PAD)
2017-03 Produced Fluid (in Barrels) RWC 802 67.88 Bbl REUSE (AT WELL PAD)
2017-04 Produced Fluid (in Barrels) RWC 802 53.53 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017-04 Produced Fluid (in Barrels) RWC 802 26.76 Bbl REUSE (AT WELL PAD)
2017-05 Produced Fluid (in Barrels) RWC 802 12.99 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017-05 Produced Fluid (in Barrels) RWC 802 12.99 Bbl REUSE (AT WELL PAD)
2017-06 Produced Fluid (in Barrels) RWC 802 93.98 Bbl REUSE (AT WELL PAD)
2017-07 Produced Fluid (in Barrels) RWC 802 25.30 Bbl REUSE (AT WELL PAD)
2017-08 Produced Fluid (in Barrels) RWC 802 37.71 Bbl REUSE (AT WELL PAD)
2017-09 Produced Fluid (in Barrels) RWC 802 38.93 Bbl REUSE (AT WELL PAD)
2017-10 Produced Fluid (in Barrels) RWC 802 49.16 Bbl REUSE (AT WELL PAD)
2017-11 Produced Fluid (in Barrels) RWC 802 120.52 Bbl REUSE (AT WELL PAD)
2017-12 Produced Fluid (in Barrels) RWC 802 63.20 Bbl REUSE (AT WELL PAD)
2018-01 Produced Fluid (in Barrels) RWC 802 49.61 Bbl REUSE (AT WELL PAD)
2018-02 Produced Fluid (in Barrels) RWC 802 33.61 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-03 Produced Fluid (in Barrels) RWC 802 48.89 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-03 Produced Fluid (in Barrels) RWC 802 16.30 Bbl REUSE (AT WELL PAD)
2018-04 Produced Fluid (in Barrels) RWC 802 15.81 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-04 Produced Fluid (in Barrels) RWC 802 16.60 Bbl REUSE (AT WELL PAD)
2018-05 Produced Fluid (in Barrels) RWC 802 86.60 Bbl REUSE (AT WELL PAD)
2018-06 Produced Fluid (in Barrels) RWC 802 78.26 Bbl REUSE (AT WELL PAD)
2018-07 Produced Fluid (in Barrels) RWC 802 45.32 Bbl REUSE (AT WELL PAD)
2018-08 Produced Fluid (in Barrels) RWC 802 7.22 Bbl REUSE (AT WELL PAD)
2018-09 Produced Fluid (in Barrels) RWC 802 58.09 Bbl REUSE (AT WELL PAD)
2018-10 Produced Fluid (in Barrels) RWC 802 30.95 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-10 Produced Fluid (in Barrels) RWC 802 30.34 Bbl REUSE (AT WELL PAD)
2018-11 Produced Fluid (in Barrels) RWC 802 45.41 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-12 Produced Fluid (in Barrels) RWC 802 108.24 Bbl REUSE (AT WELL PAD)
2019-01 Produced Fluid (in Barrels) RWC 802 60.58 Bbl REUSE (AT WELL PAD)
2019-02 Produced Fluid (in Barrels) RWC 802 68.24 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019-03 Produced Fluid (in Barrels) RWC 802 13.24 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2156000 Primary Facility 04/10/2013 Drilling/Alteration No Violations Noted Cond is set, but covered w/ plastic.
2163324 Primary Facility 05/01/2013 Routine/Complete Inspection No Violations Noted
2184254 Primary Facility 07/15/2013 Routine/Complete Inspection No Violations Noted
2279074 Primary Facility 06/11/2014 Routine/Complete Inspection No Violations Noted
2296656 Primary Facility 08/14/2014 Routine/Complete Inspection No Violations Noted
2486399 Primary Facility 2016-05-19 Routine/Complete Inspection No Violations Noted
2603365 Primary Facility 2017-06-09 Routine/Complete Inspection No Violations Noted On June 9, 2017, at 1120 hrs., the Department conducted a routine inspection at the Repsol Oil & Gas USA LLC, Abell Living Trust (05-082) Well Site in Warren Township, Bradford County. Andrew Hobbins, Water Quality Specialist, represented the Department. Nobody was present for Repsol.

The site sign, E & S plan and weekly inspection logs were on site and available for review. The site was well vegetated and no erosion issues were observed. Two PCSM bioretention basins were installed at the site.

Five wells were in production phase during the inspection. The wells were all labeled and no bubbling was observed in the well cellar. Two production tanks and four GPUs were also on site. The tanks and GPUs were on secondary containment. Puddles on the well pad surface were low in specific conductivity measuring less than 300 uS/cm. No staining was observed on the well pad surface.

The Department left the site at 1220 hrs. No violations were observed.

2799564 Primary Facility 2018-11-06 Site Restoration No Violations Noted NOT approval.

Electrical conductivity readings taken from pooled water on site with an Oakton PCSTestr 35. A puddle near the production tanks is 0.09 mS/cm today. JLP

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 06/03/2014 06/03/2014 5749 3,971,880.0 30000

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FR-8 Trican Friction Reducer Ammonium Chloride 12125-02-9 1.5 0.001027 429.156
Petroleum distillates, dewaxed heavy paraffinic 64742-65-0 8 0.005476 2288.83
Petroleum distillates, hydrotreated heavy paraffinic 64742-54-7 8 0.005476 2288.83
Mineral oil/ light hydrotreated pet. distillate 64742-47-8 28 0.019165 8010.91
LSI-21 (Scale Inhibitor) Trican Scale Inhibitor Acrylic Polymer 28205-96-1 15 0.003842 1605.99
Sodium Salt of Phosphate Ester 68131-72-6 15 0.003842 1605.99
White 40/70 Trican Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100 8.02868 3,355,880.0
FEAC-20 (Iron Control) Trican Iron Control Acetic acid 64-19-7 45 0.001611 673.576
Citric acid 77-92-9 30 0.001074 449.05
100 Mesh, Bulk (over 20K lbs)* Trican Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100 7.10669 2,970,500.0
Other Chemicals Water 7732-18-5 0 0 0
Alkyloxypolyethylene oxyethanol 84133-50-6 0 0 0
Trade Secret Proprietary 0 0 0
Ammonium Acrylate 10604-69-0 0 0 0
Acrylamide P/W acrylic acid ammonium salt 26100-47-0 0 0 0
Nonionic Surfactant Proprietary 0 0 0
Anionic polyacrylamide copolymer Proprietary 0 0 0
Sorbitol Tetraoleate 61723-83-9 0 0 0
Isopropanol 67-63-0 0 0 0
Acrylamide 79-06-1 0 0 0
Polyethylene glycol monooleate 9004-96-0 0 0 0
Sorbitan monooleate 1338-43-8 0 0 0
7 1/2% HCL Trican Carrier Hydrochloric acid 7647-01-0 7.5 0.012424 5193.04
3 1/2% HCL Trican Carrier Hydrochloric acid 7647-01-0 3.5 0.015374 6425.96
AI-7NR (Acid Inhibitor) Trican Acid Inhibitor Prop-2-yn-1-ol 107-19-7 1 0.00001500 6.34252
AQUCAR DB 5 (Water Treatment Microbiocide) Trican Biocide Sodium Bromide 7647-15-6 1.5 0.000398 166.514
Polyethylene glycol 25322-68-3 65.2 0.017316 7237.79
Dibromoacetonitrile 3252-43-5 0.5 0.000133 55.5045
2,2-dibromo-3-nitrilopropionamide 10222-01-2 5 0.001328 555.045
Water Customer Carrier Water 7732-18-5 100 79.3015 33,146,900.0
White 30/50 Trican Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100 4.83255 2,019,940.0

For data sources see[7]

References