If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-085-24663 | | Well ID: 37-085-24663 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="14" | {{#display_map: 41.141408, -80.437222 | width=100% | height=100% }} |
|- | |- | ||
− | | | + | | Country: United States |
|- | |- | ||
− | | Municipality: [[Shenango Township, | + | | State: Pennsylvania |
+ | |- | ||
+ | | County: [[Mercer_County,_Pennsylvania|Mercer]] | ||
+ | |- | ||
+ | | Municipality: [[Shenango Township,_Mercer_County,_Pennsylvania|Shenango Township]] | ||
|- | |- | ||
| Operator Name: [[HILCORP ENERGY CO]] | | Operator Name: [[HILCORP ENERGY CO]] | ||
|- | |- | ||
− | | Well Pad ID: [[ | + | | Well Pad ID: [[147642]] |
|- | |- | ||
| Farm/Lease Name: SHENANGO RADKOWSKI 3H | | Farm/Lease Name: SHENANGO RADKOWSKI 3H | ||
|- | |- | ||
− | | | + | | License Status: Active |
− | |||
− | |||
|- | |- | ||
− | | Spud Date: | + | | Spud Date: 09/28/2013 |
|- | |- | ||
− | | | + | | Permit Date: 7/30/2013 |
|- | |- | ||
− | | | + | | Unconventional Well: Y |
|- | |- | ||
− | | Well | + | | Configuration: Horizontal Well |
− | |||
− | |||
|- | |- | ||
| Latitude: 41.141408 | | Latitude: 41.141408 | ||
|- | |- | ||
| Longitude: -80.437222 | | Longitude: -80.437222 | ||
− | |||
|} | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Permits Issued Detail Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref><ref>{{cite web | ||
+ | | title = Spud Data Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-04-30 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-16 }}</ref><ref>{{cite web | ||
+ | | title = Oil and Gas Well Pad Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Period |
− | !scope="col" | | + | !scope="col" | Operator Name |
− | !scope="col" | | + | !scope="col" | Gas Quantity (mcf) |
− | !scope="col" | | + | !scope="col" | Gas Production Days |
− | !scope="col" | | + | !scope="col" | Oil Quantity (bbl) |
− | !scope="col" | | + | !scope="col" | Oil Production Days |
− | !scope="col" | | + | !scope="col" | Water Quantity (bbl) |
− | + | !scope="col" | Water Production Days | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2013 | ||
+ | | [[HILCORP ENERGY CO]] | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2014 |
− | | style="text-align:right;" | | + | | [[HILCORP ENERGY CO]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 166,326.00 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 95 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 6,531.00 |
+ | | style="text-align: right;" | 95 | ||
|- | |- | ||
+ | | 2015 | ||
+ | | [[HILCORP ENERGY CO]] | ||
+ | | style="text-align: right;" | 473,498.00 | ||
+ | | style="text-align: right;" | 342 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 5,772.00 | ||
+ | | style="text-align: right;" | 342 | ||
|- | |- | ||
− | + | | 2016 | |
− | + | | [[HILCORP ENERGY CO]] | |
− | + | | style="text-align: right;" | 304,677.00 | |
− | + | | style="text-align: right;" | 361 | |
− | + | | style="text-align: right;" | 0.00 | |
− | + | | style="text-align: right;" | 0 | |
− | + | | style="text-align: right;" | 3,193.00 | |
− | + | | style="text-align: right;" | 361 | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | 2016 | ||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | style="text-align:right;" | | ||
− | | style="text-align:right;" | | ||
− | | style="text-align:right;" | 0. | ||
− | | style="text-align:right;" | | ||
− | | style="text-align:right;" | | ||
− | | style="text-align:right;" | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2017 |
− | | | + | | [[HILCORP ENERGY CO]] |
− | | | + | | style="text-align: right;" | 260,063.00 |
− | | | + | | style="text-align: right;" | 355 |
− | | | + | | style="text-align: right;" | 0.00 |
− | | | + | | style="text-align: right;" | 0 |
− | | | + | | style="text-align: right;" | 1,982.00 |
+ | | style="text-align: right;" | 355 | ||
|- | |- | ||
+ | | 2018 | ||
+ | | [[HILCORP ENERGY CO]] | ||
+ | | style="text-align: right;" | 197,176.00 | ||
+ | | style="text-align: right;" | 346 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 1,154.00 | ||
+ | | style="text-align: right;" | 346 | ||
|- | |- | ||
− | | | + | | 2019 |
− | | | + | | [[HILCORP ENERGY CO]] |
− | | | + | | style="text-align: right;" | 55,408.00 |
− | | | + | | style="text-align: right;" | 90 |
− | | | + | | style="text-align: right;" | 390.00 |
− | | | + | | style="text-align: right;" | 90 |
− | | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = Oil and Gas | + | | title =Oil and Gas Production Reports |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2019-03-31 | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
== Waste Data == | == Waste Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Period |
− | !scope="col" | | + | !scope="col" | Waste Type |
− | !scope="col" | | + | !scope="col" | Quantity |
− | !scope="col" | | + | !scope="col" | Disposal Method |
− | !scope="col" | | + | !scope="col" | Waste Facility ID |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2013-2 | | 2013-2 | ||
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 2,514.04 Tons |
− | |||
| CENT WASTE TRT FAC NPDES DISCHARGE | | CENT WASTE TRT FAC NPDES DISCHARGE | ||
| EPA ID: 748-163 | | EPA ID: 748-163 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2014-1 | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 5,718.42 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-155-24076 | ||
|- | |- | ||
| 2015-1 | | 2015-1 | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align:right;" | 190. | + | | style="text-align: right;" | 190.00 Bbl |
− | |||
| CENT WASTE TRT FAC NPDES DISCHARGE | | CENT WASTE TRT FAC NPDES DISCHARGE | ||
| EPA ID: 748-163 | | EPA ID: 748-163 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2015-2 | | 2015-2 | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 212.00 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-007-24355 |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2015-2 | | 2015-2 | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align:right;" | 253. | + | | style="text-align: right;" | 253.00 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-133-24096 | | 34-133-24096 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2015-2 | | 2015-2 | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 638.00 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-155-21893 |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2015-2 | | 2015-2 | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 460.00 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34-155- | + | | 34-155-24063 |
− | |||
− | |||
− | |||
|- | |- | ||
− | |- | + | | 2016-1 |
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 471.00 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-155-24063 |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2016-2 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 3,040.00 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-099-23158 | | 34-099-23158 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | |- | + | | 2016-2 |
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 902.00 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-133-22523 |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2016-2 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 262.00 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-155-24079 |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2017-01 | | 2017-01 | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | 582.75 | + | | style="text-align: right;" | 582.75 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-099-23158 | | 34-099-23158 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2017-02 | |
− | | 2017- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 402.38 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-099-23158 | | 34-099-23158 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2017-03 | | 2017-03 | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | 465.75 | + | | style="text-align: right;" | 465.75 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-099-23158 | | 34-099-23158 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2017-03 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 2.50 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-133-22523 | ||
|- | |- | ||
− | | 2017- | + | | 2017-04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 482.00 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-099-23158 | | 34-099-23158 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2017-05 | |
− | | 2017- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 443.38 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-099-23158 | | 34-099-23158 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2017-06 | |
− | | 2017- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 408.13 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-133-22523 |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2017-07 | | 2017-07 | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | 395.38 | + | | style="text-align: right;" | 395.38 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-099-23158 | | 34-099-23158 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2017-07 | | 2017-07 | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | 8.13 | + | | style="text-align: right;" | 8.13 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-133-22523 | | 34-133-22523 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2017-08 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 390.25 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-099-23158 | ||
|- | |- | ||
− | | 2017- | + | | 2017-09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 264.63 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-099-23158 |
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2017-10 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 285.18 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-099-23158 | ||
|- | |- | ||
− | | 2017- | + | | 2017-11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 339.38 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-099-23158 |
− | |||
− | |||
− | |||
|- | |- | ||
− | |- | + | | 2017-12 |
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 420.25 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-099-23158 | | 34-099-23158 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2018-01 | |
− | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 2,255.00 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-155-24079 | | 34-155-24079 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2018-02 | |
− | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 3,245.00 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-155-24079 | | 34-155-24079 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2018-03 | |
− | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 3,110.00 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-155-24079 | | 34-155-24079 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2018-04 | |
− | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 2,760.00 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-155-24079 | | 34-155-24079 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2018-05 | |
− | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 2,805.00 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-155-24079 | | 34-155-24079 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2018-06 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 18.75 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-099-23158 | ||
|- | |- | ||
− | | 2018- | + | | 2018-06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 1,900.00 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-155-24079 | | 34-155-24079 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2018-07 | |
− | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 2,198.00 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-155-24079 | | 34-155-24079 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2018-08 | |
− | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 2,195.00 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-155-24079 | | 34-155-24079 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2018-09 | |
− | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 1,330.00 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-155-24079 | | 34-155-24079 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2018-10 | |
− | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 1,633.00 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-155-24079 | | 34-155-24079 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2018-11 | | 2018-11 | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 2,695.00 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-155-24079 | | 34-155-24079 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2018-12 | |
− | | 2018- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | | + | | style="text-align: right;" | 389.13 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-155-24079 | | 34-155-24079 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2019-01 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 315.63 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-099-23158 | ||
|- | |- | ||
| 2019-02 | | 2019-02 | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | 407.88 | + | | style="text-align: right;" | 407.88 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-099-23158 | | 34-099-23158 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2019-03 | | 2019-03 | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
− | | style="text-align:right;" | 299.38 | + | | style="text-align: right;" | 299.38 Bbl |
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-099-23158 | | 34-099-23158 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =Oil and Gas Waste Reports | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-03-31 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Inspection Data == | ||
+ | ==== Inspections Performed ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Inspection ID | ||
+ | !scope="col" | Inspection Category | ||
+ | !scope="col" | Inspection Date | ||
+ | !scope="col" | Inspection Type | ||
+ | !scope="col" | Inspection Result | ||
+ | !scope="col" | Inspection Comments | ||
|- | |- | ||
− | | 2019-01 | + | | 2189510 |
− | | | + | | Primary Facility |
− | | style="text-align:right;" | | + | | 08/01/2013 |
− | | | + | | Routine/Partial Inspection |
− | | | + | | No Violations Noted |
− | | 34- | + | | |
− | | | + | |- |
− | | | + | | 2196899 |
− | | | + | | Primary Facility |
+ | | 08/14/2013 | ||
+ | | Routine/Partial Inspection | ||
+ | | No Violations Noted | ||
+ | | | ||
+ | |- | ||
+ | | 2200894 | ||
+ | | Primary Facility | ||
+ | | 08/30/2013 | ||
+ | | Routine/Partial Inspection | ||
+ | | No Violations Noted | ||
+ | | | ||
+ | |- | ||
+ | | 2208467 | ||
+ | | Primary Facility | ||
+ | | 09/30/2013 | ||
+ | | Drilling/Alteration | ||
+ | | No Violations Noted | ||
+ | | | ||
+ | |- | ||
+ | | 2221090 | ||
+ | | Primary Facility | ||
+ | | 11/05/2013 | ||
+ | | Drilling/Alteration | ||
+ | | No Violations Noted | ||
+ | | | ||
+ | |- | ||
+ | | 2284942 | ||
+ | | Primary Facility | ||
+ | | 07/08/2014 | ||
+ | | Routine/Partial Inspection | ||
+ | | No Violations Noted | ||
+ | | | ||
+ | |- | ||
+ | | 2676052 | ||
+ | | Primary Facility | ||
+ | | 2017-12-28 | ||
+ | | Routine/Complete Inspection | ||
+ | | Violation(s) Noted | ||
+ | | Routine inspection of multiple well pad. Eight producing unconventional wells on site; seven gas wells and one combination oil and gas well (Photo # 2). | ||
+ | |||
+ | 9H (085-24673), unconventional gas well | ||
+ | 10H (085-24676), unconventional gas well | ||
+ | 11H (085-24674), unconventional gas well | ||
+ | 12H (085-24675), unconventional gas well | ||
+ | 6H (085-24672), unconventional gas well | ||
+ | 5H (085-24671), unconventional gas well | ||
+ | 4H (085-24670), unconventional gas well | ||
+ | 3H (085-24663), unconventional combination oil and gas well | ||
+ | |||
+ | Compressor running and stock tank vent flare lit during inspection. Four double gas processing/drier units on site. One 3,000 gal open-top box steel tank with a spreader bar mounted on top is located near well heads (Photo # 1). All wells are also plumbed to spreader bar at box tank. Liner with berm is inadequate; it is full of ice, production fluid, and/or precipitation. Liner is also folded down to 2" high at NE corner. Brine tank is not covered. Spreader bar sprays/splashes production fluid outside of dike. | ||
+ | |- | ||
+ | | 2702047 | ||
+ | | Primary Facility | ||
+ | | 2018-03-01 | ||
+ | | Routine/Partial Inspection | ||
+ | | No Violations Noted | ||
+ | | Wells 3H & 9H share a gas separator unit. Wells 4H & 10H share a gas separator unit. Wells 5H and 11H share a gas separator unit. Wells 6H & 12H share a gas separator unit. Flare stack onsite burning. Compressor on location. | ||
+ | |- | ||
+ | | 2738230 | ||
+ | | Primary Facility | ||
+ | | 2018-06-06 | ||
+ | | Compliance Evaluation | ||
+ | | No Violations Noted | ||
+ | | Compliance Evaluation Inspection to address outstanding violations against well 3H (085-24663) for use of an open-top tank to collect/store production water (PA Code 78a.57a), and spill of production water on 12/28/17 (SWMA301). Violations originally noted on inspections from 12/28/17 (ID# 2676052) and 3/15/18 (ID# 2707008). Operator has removed the open top roll-off tank that was being used to collect/store production fluid correcting the violation. Cleanup of contaminated gravel/soil cement complete. Tank and spill violations corrected. | ||
+ | |||
+ | Site restoration violations against the ESCGP permit are still open and will be addressed on a separate inspection when restoration violations are corrected. | ||
+ | |- | ||
+ | |} | ||
+ | ==== Violations Commited ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Inspection ID | ||
+ | !scope="col" | Violation ID | ||
+ | !scope="col" | Violation Date | ||
+ | !scope="col" | Date Resolved | ||
+ | !scope="col" | Violation Code | ||
+ | !scope="col" | Violation Type | ||
+ | !scope="col" | Violation Comments | ||
+ | |- | ||
+ | | 2676052 | ||
+ | | 804988 | ||
+ | | 2017-12-28 | ||
+ | | 2018-06-06 | ||
+ | | 78a64(b) | ||
+ | | Environmental Health & Safety | ||
+ | | Secondary containment or dike (liner with berm) is inadequate to hold the volume of the open-top tank because it is full of ice, production fluid and/or precipitation. | ||
+ | |- | ||
+ | | 2676052 | ||
+ | | 804989 | ||
+ | | 2017-12-28 | ||
+ | | 2018-06-06 | ||
+ | | 78A57(A) | ||
+ | | Environmental Health & Safety | ||
+ | | Open-top 3,000 gal box tank used to contain production water (brine and oil) | ||
+ | |- | ||
+ | | 2676052 | ||
+ | | 804990 | ||
+ | | 2017-12-28 | ||
+ | | 2018-06-06 | ||
+ | | SWMA 301 | ||
+ | | Environmental Health & Safety | ||
+ | | Production water (brine & oil) has overtopped and flowed from dike, and is also sprayed to ground outside of dike from use of spreader bar. Unknown volume discharged from ground; estimated at <5 gal. Spray/spill area of approx. 10'x15'. See Photo #1. | ||
+ | |- | ||
+ | |} | ||
+ | ==== Penalties Applied ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Violation ID | ||
+ | !scope="col" | Penalty ID | ||
+ | !scope="col" | Penalty Code | ||
+ | !scope="col" | Penalty Status | ||
+ | !scope="col" | Penalty Date | ||
+ | !scope="col" | Enforcement Date | ||
+ | !scope="col" | Penalty Amount | ||
+ | !scope="col" | Amount Collected | ||
+ | |- | ||
+ | | 804988 | ||
+ | | 360665 | ||
+ | | NOV - Notice of Violation | ||
+ | | | ||
+ | | | ||
+ | | 2018-06-06 | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | 804989 | ||
+ | | 360665 | ||
+ | | NOV - Notice of Violation | ||
+ | | | ||
+ | | | ||
+ | | 2018-06-06 | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | 804990 | ||
+ | | 360665 | ||
+ | | NOV - Notice of Violation | ||
+ | | | ||
+ | | | ||
+ | | 2018-06-06 | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =Oil and Gas Compliance Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | | 1 | ||
+ | | 05/18/2014 | ||
+ | | 05/26/2014 | ||
+ | | style="text-align: right;" | 7435 | ||
+ | | style="text-align: right;" | 10,687,100.0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="14"| 1 | ||
+ | | rowspan="1"| Scale Hib A | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Scale Inhibitor | ||
+ | | Ethylene Glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00210126 | ||
+ | | style="text-align: right;" | 2179.05 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Water | ||
+ | | rowspan="1"| Hilcorp | ||
+ | | rowspan="1"| Carrier/Base Fluid | ||
+ | | Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 86.0004 | ||
+ | | style="text-align: right;" | 89,183,900.0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Hydrochloric Acid (7.5%) | ||
+ | | rowspan="1"| Axiall | ||
+ | | rowspan="1"| Acidizing | ||
+ | | Hydrogen Chloride | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 7.5 | ||
+ | | style="text-align: right;" | 0.0988999 | ||
+ | | style="text-align: right;" | 102561 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Unislick ST50 | ||
+ | | rowspan="1"| CESI | ||
+ | | rowspan="1"| Friction Reducer | ||
+ | | Petroleum Distillates, Hydrotreated Light | ||
+ | | 64742-47-8 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.0200906 | ||
+ | | style="text-align: right;" | 20834.3 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Sand (Proppant) | ||
+ | | rowspan="1"| Sargent | ||
+ | | rowspan="1"| Proppant | ||
+ | | Silica | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 99.9 | ||
+ | | style="text-align: right;" | 12.5669 | ||
+ | | style="text-align: right;" | 13,032,100.0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="3"| EC6116A | ||
+ | | rowspan="3"| Nalco | ||
+ | | rowspan="3"| Biocide | ||
+ | | Dibromoacetonitrile | ||
+ | | 3252-43-5 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00135473 | ||
+ | | style="text-align: right;" | 1404.88 | ||
+ | |- | ||
+ | | 2,2-Dibromo-3-nitrilopropionamide | ||
+ | | 10222-01-2 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00812839 | ||
+ | | style="text-align: right;" | 8429.28 | ||
+ | |- | ||
+ | | Polyethylene Glycol | ||
+ | | 25322-68-3 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.0162568 | ||
+ | | style="text-align: right;" | 16858.6 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="6"| Unihib G | ||
+ | | rowspan="6"| GeoSafe | ||
+ | | rowspan="6"| Acid Inhibitor | ||
+ | | Acetophenone | ||
+ | | 98-86-2 | ||
+ | | style="text-align: right;" | 1 | ||
+ | | style="text-align: right;" | 0.00000434 | ||
+ | | style="text-align: right;" | 4.501 | ||
+ | |- | ||
+ | | Short chained glycol ether | ||
+ | | 112-34-5 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.000260437 | ||
+ | | style="text-align: right;" | 270.078 | ||
+ | |- | ||
+ | | Ethoxylated alcohol | ||
+ | | 68002-97-1 | ||
+ | | style="text-align: right;" | 35 | ||
+ | | style="text-align: right;" | 0.000151921 | ||
+ | | style="text-align: right;" | 157.545 | ||
+ | |- | ||
+ | | Thiourea | ||
+ | | 62-56-6 | ||
+ | | style="text-align: right;" | 1 | ||
+ | | style="text-align: right;" | 0.00000434 | ||
+ | | style="text-align: right;" | 4.501 | ||
+ | |- | ||
+ | | Methanol | ||
+ | | 67-56-1 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00002170 | ||
+ | | style="text-align: right;" | 22.506 | ||
+ | |- | ||
+ | | Formaldehyde | ||
+ | | 50-00-0 | ||
+ | | style="text-align: right;" | 1 | ||
+ | | style="text-align: right;" | 0.00000434 | ||
+ | | style="text-align: right;" | 4.501 | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = | + | | title =FracFocus Fracking Chemicals Database |
− | + | | date = 2019-04-02 | |
− | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | accessdate = 2019-06-19 }}</ref> |
− | | accessdate = | + | ==References== |
− | == References == | + | <references/> |
− | |||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
− | [[Category:Wells]] | + | [[Category:Pennsylvania Wells]] |
+ | [[Category:FracFocus]] |
Well ID: 37-085-24663 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.141408,"lon":-80.437222,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Mercer | |
Municipality: Shenango Township | |
Operator Name: HILCORP ENERGY CO | |
Well Pad ID: 147642 | |
Farm/Lease Name: SHENANGO RADKOWSKI 3H | |
License Status: Active | |
Spud Date: 09/28/2013 | |
Permit Date: 7/30/2013 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.141408 | |
Longitude: -80.437222 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | HILCORP ENERGY CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | HILCORP ENERGY CO | 166,326.00 | 95 | 0.00 | 0 | 6,531.00 | 95 |
2015 | HILCORP ENERGY CO | 473,498.00 | 342 | 0.00 | 0 | 5,772.00 | 342 |
2016 | HILCORP ENERGY CO | 304,677.00 | 361 | 0.00 | 0 | 3,193.00 | 361 |
2017 | HILCORP ENERGY CO | 260,063.00 | 355 | 0.00 | 0 | 1,982.00 | 355 |
2018 | HILCORP ENERGY CO | 197,176.00 | 346 | 0.00 | 0 | 1,154.00 | 346 |
2019 | HILCORP ENERGY CO | 55,408.00 | 90 | 390.00 | 90 | 0.00 | 0 |
For data sources see[4]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2013-2 | Drill Cuttings (in Tons) | 2,514.04 Tons | CENT WASTE TRT FAC NPDES DISCHARGE | EPA ID: 748-163 |
2014-1 | Fracing Fluid Waste (in Barrels) | 5,718.42 Bbl | INJECTION DISPOSAL WELL | 34-155-24076 |
2015-1 | Produced Fluid (in Barrels) | 190.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | EPA ID: 748-163 |
2015-2 | Produced Fluid (in Barrels) | 212.00 Bbl | INJECTION DISPOSAL WELL | 34-007-24355 |
2015-2 | Produced Fluid (in Barrels) | 253.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24096 |
2015-2 | Produced Fluid (in Barrels) | 638.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2015-2 | Produced Fluid (in Barrels) | 460.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24063 |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 471.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24063 |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 3,040.00 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 902.00 Bbl | INJECTION DISPOSAL WELL | 34-133-22523 |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 262.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2017-01 | Produced Fluid (in Barrels) RWC 802 | 582.75 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2017-02 | Produced Fluid (in Barrels) RWC 802 | 402.38 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2017-03 | Produced Fluid (in Barrels) RWC 802 | 465.75 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2017-03 | Produced Fluid (in Barrels) RWC 802 | 2.50 Bbl | INJECTION DISPOSAL WELL | 34-133-22523 |
2017-04 | Produced Fluid (in Barrels) RWC 802 | 482.00 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2017-05 | Produced Fluid (in Barrels) RWC 802 | 443.38 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2017-06 | Produced Fluid (in Barrels) RWC 802 | 408.13 Bbl | INJECTION DISPOSAL WELL | 34-133-22523 |
2017-07 | Produced Fluid (in Barrels) RWC 802 | 395.38 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2017-07 | Produced Fluid (in Barrels) RWC 802 | 8.13 Bbl | INJECTION DISPOSAL WELL | 34-133-22523 |
2017-08 | Produced Fluid (in Barrels) RWC 802 | 390.25 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2017-09 | Produced Fluid (in Barrels) RWC 802 | 264.63 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2017-10 | Produced Fluid (in Barrels) RWC 802 | 285.18 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2017-11 | Produced Fluid (in Barrels) RWC 802 | 339.38 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2017-12 | Produced Fluid (in Barrels) RWC 802 | 420.25 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2018-01 | Produced Fluid (in Barrels) RWC 802 | 2,255.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2018-02 | Produced Fluid (in Barrels) RWC 802 | 3,245.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2018-03 | Produced Fluid (in Barrels) RWC 802 | 3,110.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2018-04 | Produced Fluid (in Barrels) RWC 802 | 2,760.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2018-05 | Produced Fluid (in Barrels) RWC 802 | 2,805.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2018-06 | Produced Fluid (in Barrels) RWC 802 | 18.75 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2018-06 | Produced Fluid (in Barrels) RWC 802 | 1,900.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2018-07 | Produced Fluid (in Barrels) RWC 802 | 2,198.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2018-08 | Produced Fluid (in Barrels) RWC 802 | 2,195.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2018-09 | Produced Fluid (in Barrels) RWC 802 | 1,330.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2018-10 | Produced Fluid (in Barrels) RWC 802 | 1,633.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2018-11 | Produced Fluid (in Barrels) RWC 802 | 2,695.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2018-12 | Produced Fluid (in Barrels) RWC 802 | 389.13 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2019-01 | Produced Fluid (in Barrels) RWC 802 | 315.63 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2019-02 | Produced Fluid (in Barrels) RWC 802 | 407.88 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2019-03 | Produced Fluid (in Barrels) RWC 802 | 299.38 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2189510 | Primary Facility | 08/01/2013 | Routine/Partial Inspection | No Violations Noted | |
2196899 | Primary Facility | 08/14/2013 | Routine/Partial Inspection | No Violations Noted | |
2200894 | Primary Facility | 08/30/2013 | Routine/Partial Inspection | No Violations Noted | |
2208467 | Primary Facility | 09/30/2013 | Drilling/Alteration | No Violations Noted | |
2221090 | Primary Facility | 11/05/2013 | Drilling/Alteration | No Violations Noted | |
2284942 | Primary Facility | 07/08/2014 | Routine/Partial Inspection | No Violations Noted | |
2676052 | Primary Facility | 2017-12-28 | Routine/Complete Inspection | Violation(s) Noted | Routine inspection of multiple well pad. Eight producing unconventional wells on site; seven gas wells and one combination oil and gas well (Photo # 2).
9H (085-24673), unconventional gas well 10H (085-24676), unconventional gas well 11H (085-24674), unconventional gas well 12H (085-24675), unconventional gas well 6H (085-24672), unconventional gas well 5H (085-24671), unconventional gas well 4H (085-24670), unconventional gas well 3H (085-24663), unconventional combination oil and gas well Compressor running and stock tank vent flare lit during inspection. Four double gas processing/drier units on site. One 3,000 gal open-top box steel tank with a spreader bar mounted on top is located near well heads (Photo # 1). All wells are also plumbed to spreader bar at box tank. Liner with berm is inadequate; it is full of ice, production fluid, and/or precipitation. Liner is also folded down to 2" high at NE corner. Brine tank is not covered. Spreader bar sprays/splashes production fluid outside of dike. |
2702047 | Primary Facility | 2018-03-01 | Routine/Partial Inspection | No Violations Noted | Wells 3H & 9H share a gas separator unit. Wells 4H & 10H share a gas separator unit. Wells 5H and 11H share a gas separator unit. Wells 6H & 12H share a gas separator unit. Flare stack onsite burning. Compressor on location. |
2738230 | Primary Facility | 2018-06-06 | Compliance Evaluation | No Violations Noted | Compliance Evaluation Inspection to address outstanding violations against well 3H (085-24663) for use of an open-top tank to collect/store production water (PA Code 78a.57a), and spill of production water on 12/28/17 (SWMA301). Violations originally noted on inspections from 12/28/17 (ID# 2676052) and 3/15/18 (ID# 2707008). Operator has removed the open top roll-off tank that was being used to collect/store production fluid correcting the violation. Cleanup of contaminated gravel/soil cement complete. Tank and spill violations corrected.
Site restoration violations against the ESCGP permit are still open and will be addressed on a separate inspection when restoration violations are corrected. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2676052 | 804988 | 2017-12-28 | 2018-06-06 | 78a64(b) | Environmental Health & Safety | Secondary containment or dike (liner with berm) is inadequate to hold the volume of the open-top tank because it is full of ice, production fluid and/or precipitation. |
2676052 | 804989 | 2017-12-28 | 2018-06-06 | 78A57(A) | Environmental Health & Safety | Open-top 3,000 gal box tank used to contain production water (brine and oil) |
2676052 | 804990 | 2017-12-28 | 2018-06-06 | SWMA 301 | Environmental Health & Safety | Production water (brine & oil) has overtopped and flowed from dike, and is also sprayed to ground outside of dike from use of spreader bar. Unknown volume discharged from ground; estimated at <5 gal. Spray/spill area of approx. 10'x15'. See Photo #1. |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
804988 | 360665 | NOV - Notice of Violation | 2018-06-06 | ||||
804989 | 360665 | NOV - Notice of Violation | 2018-06-06 | ||||
804990 | 360665 | NOV - Notice of Violation | 2018-06-06 |
For data sources see[6]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 05/18/2014 | 05/26/2014 | 7435 | 10,687,100.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Scale Hib A | Nalco | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 30 | 0.00210126 | 2179.05 |
Water | Hilcorp | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 86.0004 | 89,183,900.0 | |
Hydrochloric Acid (7.5%) | Axiall | Acidizing | Hydrogen Chloride | 7647-01-0 | 7.5 | 0.0988999 | 102561 | |
Unislick ST50 | CESI | Friction Reducer | Petroleum Distillates, Hydrotreated Light | 64742-47-8 | 30 | 0.0200906 | 20834.3 | |
Sand (Proppant) | Sargent | Proppant | Silica | 14808-60-7 | 99.9 | 12.5669 | 13,032,100.0 | |
EC6116A | Nalco | Biocide | Dibromoacetonitrile | 3252-43-5 | 5 | 0.00135473 | 1404.88 | |
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30 | 0.00812839 | 8429.28 | ||||
Polyethylene Glycol | 25322-68-3 | 60 | 0.0162568 | 16858.6 | ||||
Unihib G | GeoSafe | Acid Inhibitor | Acetophenone | 98-86-2 | 1 | 0.00000434 | 4.501 | |
Short chained glycol ether | 112-34-5 | 60 | 0.000260437 | 270.078 | ||||
Ethoxylated alcohol | 68002-97-1 | 35 | 0.000151921 | 157.545 | ||||
Thiourea | 62-56-6 | 1 | 0.00000434 | 4.501 | ||||
Methanol | 67-56-1 | 5 | 0.00002170 | 22.506 | ||||
Formaldehyde | 50-00-0 | 1 | 0.00000434 | 4.501 |
For data sources see[7]