X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-005-22987"

m
m
Line 1: Line 1:
__TOC__
+
__TOC__
 
== Well Details ==
 
== Well Details ==
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-005-22987
 
| Well ID: 34-005-22987
| style="height=100%; align=center" rowspan="15" | {{#display_map: 40.81509876, -82.36729778 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 40.815042032, -82.36741178 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Ashland County, Ohio|Ashland]]
+
| Country: United States
 
|-
 
|-
| Municipality:  
+
| State: Ohio
 
|-
 
|-
| Operator Name: [[COLUMBIA GAS TRANSMISSION]]
+
| County: [[Ashland_County,_Ohio|Ashland]]
 +
|-
 +
| Municipality: [[Milton_Township,_Ashland_County,_Ohio|Milton Township]]
 +
|-
 +
| Operator Name: [[COLUMBIA GAS TRANSMISSION LLC]]
 
|-
 
|-
 
| Well Pad ID:  
 
| Well Pad ID:  
 
|-
 
|-
| Farm/Lease Name:  
+
| Farm/Lease Name: PITTENGER RAYMOND N
 
|-
 
|-
| First Permit Date:  
+
| License Status: Storage Well
 
|-
 
|-
| Last Permit Date:  
+
| License Date: 1973-08-14
 
|-
 
|-
 
| Spud Date: 1973-08-01
 
| Spud Date: 1973-08-01
 
|-
 
|-
| Unconventional: No
+
| Spud Drilling Contractor:  
 +
|-
 +
| Final Drill Date: 1973-10-01
 +
|-
 +
| Well Total Depth: 2640 ft
 
|-
 
|-
 
| Configuration: Vertical
 
| Configuration: Vertical
 
|-
 
|-
| Well Status: Storage Well
+
| Latitude: 40.815042032
 +
|-
 +
| Longitude: -82.36741178
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Well Status
 +
!scope="col" style="width: 15%;text-align: center"| Well Status Date
 +
!scope="col" style="text-align: center"| Comment
 +
|-
 +
| Original Spud
 +
| 1973-08-01
 +
| STORAGE,#264 DF=1255.5
 +
|-
 +
| CO
 +
| 1973-08-14
 +
| 22  COLUMBIA GAS TRANSMISSION  GeoDate  8/14/73
 +
|-
 +
| Oil and Gas
 +
| 1973-08-14
 +
| Issued Date 8/14/73 Expired Date  Acres 0156000 Tool Type CT Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
 +
|-
 +
| Completed
 +
| 1973-10-01
 +
| STORAGE,#264 DF=1255.5
 +
|-
 +
| Reached Total Depth
 +
| 1973-10-01
 +
| STORAGE,#264 DF=1255.5
 
|-
 
|-
| Violations: 0
+
| Record Last Modified
 +
| 2013-05-23
 +
| STORAGE,#264 DF=1255.5
 
|-
 
|-
| Latitude: 40.81509876
+
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well and WellHistry Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Perforation Treatments ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Perforation Date
 +
!scope="col" style="text-align: center"| Interval Top (ft)
 +
!scope="col" style="text-align: center"| Interval Base (ft)
 +
!scope="col" style="text-align: center"| Number of Shots
 
|-
 
|-
| Longitude: -82.36729778
+
| 2006-09-11
 +
| style="text-align: right;" | 2616
 +
| style="text-align: right;" | 2626
 +
| style="text-align: right;" | 0
 
|-
 
|-
 
|}
 
|}
== Inspection Data ==
+
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Perfs Table
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
<!--== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Job Start Date
 +
!scope="col" style="text-align: center"| Job End Date
 +
!scope="col" style="text-align: center"| True Vertical Depth (ft)
 +
!scope="col" style="text-align: center"| Total Water Volume (gal)
 +
!scope="col" style="text-align: center"| Total Non-Water Volume (gal)
 +
|-
 +
|}-->
 +
<!--==== Fluid Composition Data ====
 +
{| class="wikitable sortable" style="width: 100%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Trade Name
 +
!scope="col" style="text-align: center"| Supplier
 +
!scope="col" style="text-align: center"| Purpose
 +
!scope="col" style="text-align: center"| Ingredient Name
 +
!scope="col" style="white-space: nowrap;text-align: center"| CAS Number
 +
!scope="col" style="text-align: center"| Additive Percentage by Mass
 +
!scope="col" style="text-align: center"| Job Percentage by Mass
 +
!scope="col" style="text-align: center"| Mass Used (lb)
 +
|-
 +
|}-->
 +
== Stimulations Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" style="text-align: center"| Stimulation Date
!scope="col" | DATE
+
!scope="col" style="text-align: center"| Chemical Agent
!scope="col" | DESCRIPTION
+
!scope="col" style="text-align: center"| Chemical Agent Concentration (%)
!scope="col" | COMMENT
+
!scope="col" style="text-align: center"| Fracking Fluid Volume
!scope="col" | VIOLATION ID
+
!scope="col" style="text-align: center"| Mass of Proppant Used (lb)
!scope="col" | VIOLATION CODE
+
!scope="col" style="text-align: center"| Fracking Company
!scope="col" | VIOLATION COMMENT
+
!scope="col" style="text-align: center"| Comments
 
|-
 
|-
| -1724863182
 
| 2014-09-10
 
 
|  
 
|  
| ID posted, location maintained.
+
| N2
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 72 Mscf
 +
| style="text-align: right;" | 17850
 +
|
 +
| BDP 3200#; TRT. PRESS. 2150#; WELL SHUT IN @ 1300#.
 +
|-
 
|  
 
|  
 +
| ACID
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 150 Gal
 +
| style="text-align: right;" | 0
 
|  
 
|  
 
|  
 
|  
 
|-
 
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - tblStimulation Table
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
<!--== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Gas Quantity (mcf)
 +
!scope="col" style="text-align: center"| Oil Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 +
|-
 +
|}-->
 +
<!--== Waste Data ==
 +
{| class="wikitable sortable"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Waste Type
 +
!scope="col" style="text-align: center"| Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 +
|-
 +
|}-->
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Inspection ID
 +
!scope="col" style="text-align: center"| Inspection Date
 +
!scope="col" style="text-align: center"| Inspection Type
 +
!scope="col" style="text-align: center"| Inspection Result
 +
!scope="col" style="text-align: center"| Inspection Comments
 +
|-
 +
| 0411552899
 +
| 2017-04-11
 +
| Storage Well
 +
| No Violations
 +
| ID is posted and the location is maintained.  The well is shut in at the gate valve; the annulus is open.  There is no separator at the well.  There is a 10 barrel tank connected to the pipeline tie in.
 
|-
 
|-
| 482869633
+
| 0482869633
 
| 2013-10-28
 
| 2013-10-28
|  
+
| Storage Well
 +
| No Violations
 
| ID posted, well site maintained.
 
| ID posted, well site maintained.
|  
+
|-
|  
+
| 0677869844
|  
+
| 2019-03-11
 +
| Storage Well
 +
| No Violations
 +
| Performed annual inspection for Columbia Gas Storage Well #11506 on 03/11/2019.  The well is equipped with a flanged wellhead with 1-master valve and 1-wing valve, 1-meter with 2-regulators, and 1-25 bbl steel tank.  Well identification is clearly displayed.  No problems were noted at the time of the inspection.
 +
|-
 +
| 0688411594
 +
| 2016-04-05
 +
| Storage Well
 +
| No Violations
 +
| ID is posted and the location is maintained.  The well is shut in at the gate valve; the annulus is open.  There is a fluid tank at the well but there is no separator.
 +
|-
 +
| 1438214137
 +
| 2019-02-25
 +
| Storage Well
 +
| No Violations
 +
| Inspect well, identification is posted.  A steel 150 gallon storage drip tank is on location.  Gas meter is located at well head.
 +
|-
 +
| 1724863182
 +
| 2014-09-10
 +
| Storage Well
 +
| No Violations
 +
| ID posted, location maintained.
 +
|-
 +
| 1791913506
 +
| 2015-07-28
 +
| Storage Well
 +
| No Violations
 +
| ID is posted.  The well is not equipped with a drip.  The backside valve is open and the well location is maintained.
 +
|-
 +
| 1884673473
 +
| 2018-03-27
 +
| Storage Well
 +
| No Violations
 +
| ID is posted and the location is maintained.  The well is shut in at the gate valve; the annulus is open.  There is a 20 barrel tank and a house gas connection at the pipeline tie in.
 
|-
 
|-
 
|}
 
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Inspection ID
 +
!scope="col" style="text-align: center"| Violation ID
 +
!scope="col" style="text-align: center"| Violation Date
 +
!scope="col" style="text-align: center"| Violation Code
 +
!scope="col" style="text-align: center"| Violation Comments
 +
|-
 +
|}-->
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Ohio Department of Natural Resources RBDMS
+
  | title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables
  | publisher = [http://oilandgas.ohiodnr.gov/]
+
  |publisher = [[Ohio Department of Natural Resources]]
  | date = 2015-06-19
+
  | date = 2019-05-07
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection
+
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2015-06-20 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
== References ==
+
==References==
{{reflist}}
+
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Ohio Wells]]

Revision as of 05:30, 24 July 2019

Well Details

Well ID: 34-005-22987
Loading map...
Country: United States
State: Ohio
County: Ashland
Municipality: Milton Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: PITTENGER RAYMOND N
License Status: Storage Well
License Date: 1973-08-14
Spud Date: 1973-08-01
Spud Drilling Contractor:
Final Drill Date: 1973-10-01
Well Total Depth: 2640 ft
Configuration: Vertical
Latitude: 40.815042032
Longitude: -82.36741178

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1973-08-01 STORAGE,#264 DF=1255.5
CO 1973-08-14 22 COLUMBIA GAS TRANSMISSION GeoDate 8/14/73
Oil and Gas 1973-08-14 Issued Date 8/14/73 Expired Date Acres 0156000 Tool Type CT Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Completed 1973-10-01 STORAGE,#264 DF=1255.5
Reached Total Depth 1973-10-01 STORAGE,#264 DF=1255.5
Record Last Modified 2013-05-23 STORAGE,#264 DF=1255.5

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 2616 2626 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 72 Mscf 17850 BDP 3200#; TRT. PRESS. 2150#; WELL SHUT IN @ 1300#.
ACID 0 150 Gal 0

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0411552899 2017-04-11 Storage Well No Violations ID is posted and the location is maintained. The well is shut in at the gate valve; the annulus is open. There is no separator at the well. There is a 10 barrel tank connected to the pipeline tie in.
0482869633 2013-10-28 Storage Well No Violations ID posted, well site maintained.
0677869844 2019-03-11 Storage Well No Violations Performed annual inspection for Columbia Gas Storage Well #11506 on 03/11/2019. The well is equipped with a flanged wellhead with 1-master valve and 1-wing valve, 1-meter with 2-regulators, and 1-25 bbl steel tank. Well identification is clearly displayed. No problems were noted at the time of the inspection.
0688411594 2016-04-05 Storage Well No Violations ID is posted and the location is maintained. The well is shut in at the gate valve; the annulus is open. There is a fluid tank at the well but there is no separator.
1438214137 2019-02-25 Storage Well No Violations Inspect well, identification is posted. A steel 150 gallon storage drip tank is on location. Gas meter is located at well head.
1724863182 2014-09-10 Storage Well No Violations ID posted, location maintained.
1791913506 2015-07-28 Storage Well No Violations ID is posted. The well is not equipped with a drip. The backside valve is open and the well location is maintained.
1884673473 2018-03-27 Storage Well No Violations ID is posted and the location is maintained. The well is shut in at the gate valve; the annulus is open. There is a 20 barrel tank and a house gas connection at the pipeline tie in.

For data sources see[5]