X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-173-61132"

m
m
Line 1: Line 1:
__TOC__
+
__TOC__
 
== Well Details ==
 
== Well Details ==
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-173-61132
 
| Well ID: 34-173-61132
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.2389974, -83.52963081 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 41.239050799, -83.52956029 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Wood County, Ohio|Wood]]
+
| Country: United States
 
|-
 
|-
| Municipality:  
+
| State: Ohio
 +
|-
 +
| County: [[Wood_County,_Ohio|Wood]]
 +
|-
 +
| Municipality: [[Perry_Township,_Wood_County,_Ohio|Perry Township]]
 
|-
 
|-
 
| Operator Name: [[LANDOWNER GRANT PROGRAM 2008]]
 
| Operator Name: [[LANDOWNER GRANT PROGRAM 2008]]
Line 13: Line 17:
 
| Well Pad ID:  
 
| Well Pad ID:  
 
|-
 
|-
| Farm/Lease Name:  
+
| Farm/Lease Name: HOOT KENNETH
 
|-
 
|-
| First Permit Date:  
+
| License Status: Final Restoration
 
|-
 
|-
| Last Permit Date:  
+
| License Date: 2009-02-26
 
|-
 
|-
 
| Spud Date:  
 
| Spud Date:  
 
|-
 
|-
| Unconventional: No
+
| Spud Drilling Contractor:
 +
|-
 +
| Final Drill Date:
 +
|-
 +
| Well Total Depth:  
 
|-
 
|-
 
| Configuration: Vertical
 
| Configuration: Vertical
 
|-
 
|-
| Well Status: Final Restoration
+
| Latitude: 41.239050799
 
|-
 
|-
| Violations: 0
+
| Longitude: -83.52956029
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Well Status
 +
!scope="col" style="width: 15%;text-align: center"| Well Status Date
 +
!scope="col" style="text-align: center"| Comment
 +
|-
 +
| Oil and Gas
 +
| 2005-04-25
 +
| LOCATED ON THE PROPERTY OF KEN HOOT. MR. HOOT SAID THE WELL WAS LAST OPERATED BY THE BANKRUPT CYGNET OIL & GAS CO.  WELL WILL BE SUBMITTED TO THE I & O PROGRAM.
 
|-
 
|-
| Latitude: 41.2389974
+
| Change of Owner
 +
| 2006-03-23
 +
| Operator changed from 9999, UNKNOWN OWNER to 7952, LANDOWNER GRANT PROGRAM 2006
 
|-
 
|-
| Longitude: -83.52963081
+
| APP
 +
| 2006-03-24
 +
| Proposed Formations:TRENTON, Issued Date:3/24/2006, Expired Date:3/24/2007 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
 +
|-
 +
| Change of Owner
 +
| 2008-11-06
 +
| Operator changed from 7952, LANDOWNER GRANT PROGRAM 2006 to 8389, LANDOWNER GRANT PROGRAM 2008
 +
|-
 +
| APP
 +
| 2009-01-08
 +
| Proposed Formations:TRENTON, Issued Date:1/8/2009, Expired Date:1/8/2010 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
 +
|-
 +
| Plugged by Orphan Well Program
 +
| 2009-02-19
 +
| Plugged by Orphan Well Program
 +
|-
 +
| Plugged/Abandoned
 +
| 2009-02-19
 +
| LOCATED ON THE PROPERTY OF KEN HOOT. MR. HOOT SAID THE WELL WAS LAST OPERATED BY THE BANKRUPT CYGNET OIL & GAS CO.  WELL WILL BE SUBMITTED TO THE I & O PROGRAM.
 +
|-
 +
| Construction Permit Expires
 +
| 2010-01-08
 +
| LOCATED ON THE PROPERTY OF KEN HOOT. MR. HOOT SAID THE WELL WAS LAST OPERATED BY THE BANKRUPT CYGNET OIL & GAS CO.  WELL WILL BE SUBMITTED TO THE I & O PROGRAM.
 +
|-
 +
| Record Last Modified
 +
| 2013-03-14
 +
| LOCATED ON THE PROPERTY OF KEN HOOT. MR. HOOT SAID THE WELL WAS LAST OPERATED BY THE BANKRUPT CYGNET OIL & GAS CO.  WELL WILL BE SUBMITTED TO THE I & O PROGRAM.
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well and WellHistry Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
<!--== Perforation Treatments ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Perforation Date
 +
!scope="col" style="text-align: center"| Interval Top (ft)
 +
!scope="col" style="text-align: center"| Interval Base (ft)
 +
!scope="col" style="text-align: center"| Number of Shots
 +
|-
 +
|}-->
 +
<!--== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Job Start Date
 +
!scope="col" style="text-align: center"| Job End Date
 +
!scope="col" style="text-align: center"| True Vertical Depth (ft)
 +
!scope="col" style="text-align: center"| Total Water Volume (gal)
 +
!scope="col" style="text-align: center"| Total Non-Water Volume (gal)
 +
|-
 +
|}-->
 +
<!--==== Fluid Composition Data ====
 +
{| class="wikitable sortable" style="width: 100%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Trade Name
 +
!scope="col" style="text-align: center"| Supplier
 +
!scope="col" style="text-align: center"| Purpose
 +
!scope="col" style="text-align: center"| Ingredient Name
 +
!scope="col" style="white-space: nowrap;text-align: center"| CAS Number
 +
!scope="col" style="text-align: center"| Additive Percentage by Mass
 +
!scope="col" style="text-align: center"| Job Percentage by Mass
 +
!scope="col" style="text-align: center"| Mass Used (lb)
 +
|-
 +
|}-->
 +
<!--== Stimulations Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Stimulation Date
 +
!scope="col" style="text-align: center"| Chemical Agent
 +
!scope="col" style="text-align: center"| Chemical Agent Concentration (%)
 +
!scope="col" style="text-align: center"| Fracking Fluid Volume
 +
!scope="col" style="text-align: center"| Mass of Proppant Used (lb)
 +
!scope="col" style="text-align: center"| Fracking Company
 +
!scope="col" style="text-align: center"| Comments
 +
|-
 +
|}-->
 +
<!--== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Gas Quantity (mcf)
 +
!scope="col" style="text-align: center"| Oil Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 +
|-
 +
|}-->
 +
<!--== Waste Data ==
 +
{| class="wikitable sortable"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Waste Type
 +
!scope="col" style="text-align: center"| Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 +
|-
 +
|}-->
 
== Inspection Data ==
 
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" style="text-align: center"| Inspection ID
!scope="col" | DATE
+
!scope="col" style="text-align: center"| Inspection Date
!scope="col" | DESCRIPTION
+
!scope="col" style="text-align: center"| Inspection Type
!scope="col" | COMMENT
+
!scope="col" style="text-align: center"| Inspection Result
!scope="col" | VIOLATION ID
+
!scope="col" style="text-align: center"| Inspection Comments
!scope="col" | VIOLATION CODE
 
!scope="col" | VIOLATION COMMENT
 
 
|-
 
|-
 
| 1093092715
 
| 1093092715
 
| 2009-02-19
 
| 2009-02-19
|  
+
| Plug / Plug Back
 +
| No Violations
 
| Well cleaned out to depth 1070 feet. Well has 3 inch pipe cemented at surface. Operator used 1 1/2 inch pipe an bit to clean out well. Well checked for circulation. Cement pumped through 1 1/2 inch tubing. Water circulated to tank until cement noted. Water well associated with well was plugged to within 6 feet of surface. Landowner wants wells cut off 6 feet below ground.
 
| Well cleaned out to depth 1070 feet. Well has 3 inch pipe cemented at surface. Operator used 1 1/2 inch pipe an bit to clean out well. Well checked for circulation. Cement pumped through 1 1/2 inch tubing. Water circulated to tank until cement noted. Water well associated with well was plugged to within 6 feet of surface. Landowner wants wells cut off 6 feet below ground.
|
 
|
 
|
 
|-
 
 
|-
 
|-
| 1.15139E+15
+
| 1151387072
 
| 2005-04-18
 
| 2005-04-18
|  
+
| Orphan
 +
| No Violations
 
| The well is located on the property of Ken Hoot. Mr. Hoot said the well was last operated by the bankrupt Cygnet Oil & Gas Co. The well will be submitted to the I&O program and will be designated as well OW-3.
 
| The well is located on the property of Ken Hoot. Mr. Hoot said the well was last operated by the bankrupt Cygnet Oil & Gas Co. The well will be submitted to the I&O program and will be designated as well OW-3.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1233256688
 
| 1233256688
 
| 2009-01-29
 
| 2009-01-29
|  
+
| Orphan
 +
| No Violations
 
| When operator excavated around 8 inch pipe exposed at surface to begin work, another 8 inch pipe below ground was discovered approximately 3 feet from the first. The buried 8 inch pipe had 6 inch and 3 inch pipe cemented inside the 8 inch. The open 8 inch at surface is a water well. Operator reached depth of 160 feet at bottom of well. Well will be plugged with cement. Operator waiting for decision from Columbus on plugging other casing since they do not have equipment for small diameter hole and would not have bid job at price awarded.
 
| When operator excavated around 8 inch pipe exposed at surface to begin work, another 8 inch pipe below ground was discovered approximately 3 feet from the first. The buried 8 inch pipe had 6 inch and 3 inch pipe cemented inside the 8 inch. The open 8 inch at surface is a water well. Operator reached depth of 160 feet at bottom of well. Well will be plugged with cement. Operator waiting for decision from Columbus on plugging other casing since they do not have equipment for small diameter hole and would not have bid job at price awarded.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1235064658
 
| 1235064658
 
| 2009-02-17
 
| 2009-02-17
|  
+
| Orphan
 +
| No Violations
 
| Operator attempted to plug well. Cement truck on site. Could not get circulation in well before starting to pump cement. Cement load returned. Operator called later in day and said 2 inch pipe was plugged 300 feet from bottom.
 
| Operator attempted to plug well. Cement truck on site. Could not get circulation in well before starting to pump cement. Cement load returned. Operator called later in day and said 2 inch pipe was plugged 300 feet from bottom.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1236029866
 
| 1236029866
 
| 2009-02-26
 
| 2009-02-26
|  
+
| Final Restoration
 +
| No Violations
 
| All equipment has been removed. Well has been cut off below ground and ID plate attached.  Pit backfilled. This is farm field so no planting needed. Final restoration acceptable.
 
| All equipment has been removed. Well has been cut off below ground and ID plate attached.  Pit backfilled. This is farm field so no planting needed. Final restoration acceptable.
|
 
|
 
|
 
|-
 
 
|-
 
|-
| -1989991907
+
| 1989991907
 
| 2009-02-03
 
| 2009-02-03
|  
+
| Orphan
 +
| No Violations
 
| Pit has been excavated to expose both casing for the well. The open 8 inch water well casing had water at a depth of about 10 feet below ground elevation. The oil/gas well had 3 inch tubing cemented inside 6 inch casing. Both wells will be plugged.
 
| Pit has been excavated to expose both casing for the well. The open 8 inch water well casing had water at a depth of about 10 feet below ground elevation. The oil/gas well had 3 inch tubing cemented inside 6 inch casing. Both wells will be plugged.
|
 
|
 
|
 
 
|-
 
|-
 
|}
 
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Inspection ID
 +
!scope="col" style="text-align: center"| Violation ID
 +
!scope="col" style="text-align: center"| Violation Date
 +
!scope="col" style="text-align: center"| Violation Code
 +
!scope="col" style="text-align: center"| Violation Comments
 +
|-
 +
|}-->
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Ohio Department of Natural Resources RBDMS
+
  | title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables
  | publisher = [http://oilandgas.ohiodnr.gov/]
+
  |publisher = [[Ohio Department of Natural Resources]]
  | date = 2015-06-19
+
  | date = 2019-05-07
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection
+
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2015-06-20 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
== References ==
+
==References==
{{reflist}}
+
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Ohio Wells]]

Revision as of 22:41, 24 July 2019

Well Details

Well ID: 34-173-61132
Loading map...
Country: United States
State: Ohio
County: Wood
Municipality: Perry Township
Operator Name: LANDOWNER GRANT PROGRAM 2008
Well Pad ID:
Farm/Lease Name: HOOT KENNETH
License Status: Final Restoration
License Date: 2009-02-26
Spud Date:
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 41.239050799
Longitude: -83.52956029

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 2005-04-25 LOCATED ON THE PROPERTY OF KEN HOOT. MR. HOOT SAID THE WELL WAS LAST OPERATED BY THE BANKRUPT CYGNET OIL & GAS CO. WELL WILL BE SUBMITTED TO THE I & O PROGRAM.
Change of Owner 2006-03-23 Operator changed from 9999, UNKNOWN OWNER to 7952, LANDOWNER GRANT PROGRAM 2006
APP 2006-03-24 Proposed Formations:TRENTON, Issued Date:3/24/2006, Expired Date:3/24/2007 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Change of Owner 2008-11-06 Operator changed from 7952, LANDOWNER GRANT PROGRAM 2006 to 8389, LANDOWNER GRANT PROGRAM 2008
APP 2009-01-08 Proposed Formations:TRENTON, Issued Date:1/8/2009, Expired Date:1/8/2010 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Plugged by Orphan Well Program 2009-02-19 Plugged by Orphan Well Program
Plugged/Abandoned 2009-02-19 LOCATED ON THE PROPERTY OF KEN HOOT. MR. HOOT SAID THE WELL WAS LAST OPERATED BY THE BANKRUPT CYGNET OIL & GAS CO. WELL WILL BE SUBMITTED TO THE I & O PROGRAM.
Construction Permit Expires 2010-01-08 LOCATED ON THE PROPERTY OF KEN HOOT. MR. HOOT SAID THE WELL WAS LAST OPERATED BY THE BANKRUPT CYGNET OIL & GAS CO. WELL WILL BE SUBMITTED TO THE I & O PROGRAM.
Record Last Modified 2013-03-14 LOCATED ON THE PROPERTY OF KEN HOOT. MR. HOOT SAID THE WELL WAS LAST OPERATED BY THE BANKRUPT CYGNET OIL & GAS CO. WELL WILL BE SUBMITTED TO THE I & O PROGRAM.

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1093092715 2009-02-19 Plug / Plug Back No Violations Well cleaned out to depth 1070 feet. Well has 3 inch pipe cemented at surface. Operator used 1 1/2 inch pipe an bit to clean out well. Well checked for circulation. Cement pumped through 1 1/2 inch tubing. Water circulated to tank until cement noted. Water well associated with well was plugged to within 6 feet of surface. Landowner wants wells cut off 6 feet below ground.
1151387072 2005-04-18 Orphan No Violations The well is located on the property of Ken Hoot. Mr. Hoot said the well was last operated by the bankrupt Cygnet Oil & Gas Co. The well will be submitted to the I&O program and will be designated as well OW-3.
1233256688 2009-01-29 Orphan No Violations When operator excavated around 8 inch pipe exposed at surface to begin work, another 8 inch pipe below ground was discovered approximately 3 feet from the first. The buried 8 inch pipe had 6 inch and 3 inch pipe cemented inside the 8 inch. The open 8 inch at surface is a water well. Operator reached depth of 160 feet at bottom of well. Well will be plugged with cement. Operator waiting for decision from Columbus on plugging other casing since they do not have equipment for small diameter hole and would not have bid job at price awarded.
1235064658 2009-02-17 Orphan No Violations Operator attempted to plug well. Cement truck on site. Could not get circulation in well before starting to pump cement. Cement load returned. Operator called later in day and said 2 inch pipe was plugged 300 feet from bottom.
1236029866 2009-02-26 Final Restoration No Violations All equipment has been removed. Well has been cut off below ground and ID plate attached. Pit backfilled. This is farm field so no planting needed. Final restoration acceptable.
1989991907 2009-02-03 Orphan No Violations Pit has been excavated to expose both casing for the well. The open 8 inch water well casing had water at a depth of about 10 feet below ground elevation. The oil/gas well had 3 inch tubing cemented inside 6 inch casing. Both wells will be plugged.