X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-035-21956"

m
m
Line 11: Line 11:
 
| County: [[Cuyahoga_County,_Ohio|Cuyahoga]]
 
| County: [[Cuyahoga_County,_Ohio|Cuyahoga]]
 
|-
 
|-
| Municipality:  
+
| Municipality: Mayfield Township
 
|-
 
|-
 
| Operator Name: [[BASS ENERGY CO INC]]
 
| Operator Name: [[BASS ENERGY CO INC]]
Line 21: Line 21:
 
| License Status: Producing
 
| License Status: Producing
 
|-
 
|-
| License Date: 2008-06-30
+
| License Date: 2007-01-24
 
|-
 
|-
 
| Spud Date: 2007-10-03
 
| Spud Date: 2007-10-03

Revision as of 14:16, 25 July 2019

Well Details

Well ID: 34-035-21956
Loading map...
Country: United States
State: Ohio
County: Cuyahoga
Municipality: Mayfield Township
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name: KNOLLWOOD CEMETERY UNIT
License Status: Producing
License Date: 2007-01-24
Spud Date: 2007-10-03
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2007-10-17
Well Total Depth: 3850 ft
Configuration: Directional
Latitude: 41.512739217
Longitude: -81.45105723

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-01-24 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:1/24/2007, Expired Date:1/24/2008 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2007-10-17
Construction Permit Expires 2008-01-24
Completion Report Received 2008-03-04
Correction to Well 2008-03-21 CORRECTION TO TARGET INFORMATION: NEW LOCATION= 375'NL & 4085'EL OF LOT 22, TRACT 3; X= 2,286,500; Y= 674,550.
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-06-30 3552 3574 45

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 48309 Gal 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 BASS ENERGY CO INC 62454 142 365
2009 BASS ENERGY CO INC 55846 157 365
2010 BASS ENERGY CO INC 30046 61 365
2011 BASS ENERGY CO INC 21056 26 0
2012 BASS ENERGY CO INC 15406 45 366
2013 BASS ENERGY CO INC 13079 37 365
2014 BASS ENERGY CO INC 11535 37 365
2015 BASS ENERGY CO INC 7970 0 365
2016 BASS ENERGY CO INC 8463 67 365
2017 BASS ENERGY CO INC 4582 66 365
2018 BASS ENERGY CO INC 2500 44 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 BASS ENERGY CO INC Brine 31 365
2009 BASS ENERGY CO INC Brine 0 365
2010 BASS ENERGY CO INC Brine 80 365
2011 BASS ENERGY CO INC Brine 70
2012 BASS ENERGY CO INC Brine 23 366
2013 BASS ENERGY CO INC Brine 0 365
2014 BASS ENERGY CO INC Brine 0 365
2015 BASS ENERGY CO INC Brine 7 365
2016 BASS ENERGY CO INC Brine 0 365
2017 BASS ENERGY CO INC Brine 12 365
2018 BASS ENERGY CO INC Brine 12 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0507586464 2011-12-27 UrbanPreliminary Restoration No Violations On 12/27/2011, DNR Inspector Richard Skidmore completed an urban preliminary restoration well inspection for DNR Inspector Ray Wallace. The lease road, tank battery, and well head locations are in compliance with 1501:9-9-05. Inspection passed.
0895313555 2017-08-16 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger lift system and associated tank battery in separate chain-link enclosures located on the grounds of a cemetery. The enclosure gates were locked. The load line valves were secure. The secondary containment was intact. The battery is shared with the #1, #2, and #3D wells. Fittings and connections at the wellhead and battery were secure. The surrounding areas are comprised of managed turf grass. I did not observe any signs of problems.
1374687940 2013-07-24 UrbanProduction Wells No Violations The producing unit consists of a wellhead with mechanical plunger-lift unit and above-ground storage tank (AST) battery. The wellhead is located in a chain-link enclosure which is locked. Unit ID is good. The well is currently producing. I did not observe any signs of leakage or problems. The AST battery is comprised on two 140-barreil production tanks, one 50-barrel brine tank in a chain-link enclosure. Two mechanical separstors are located outside the enclosure. The battery is shared with the #1828 and #1829 units. Secondary containment is good and safety equipment is present in accordance with 1501:9-9-05E.
1770906348 2007-10-04 Drill / Deepen / Reopen No Violations surface

For data sources see[9]

References