X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-111-24855"

m
m
Line 15: Line 15:
 
| Operator Name: [[ECLIPSE RESOURCES I LP]]
 
| Operator Name: [[ECLIPSE RESOURCES I LP]]
 
|-
 
|-
| Well Pad ID: [[001589]]
+
| Well Pad ID: [[US-OH-001589]]
 
|-
 
|-
 
| Farm/Lease Name: PITTMAN
 
| Farm/Lease Name: PITTMAN
Line 21: Line 21:
 
| License Status: Drilling
 
| License Status: Drilling
 
|-
 
|-
| License Date: 2018-12-01
+
| License Date: 2018-11-13
 
|-
 
|-
 
| Spud Date: 2018-12-01
 
| Spud Date: 2018-12-01

Revision as of 01:07, 26 July 2019

Well Details

Well ID: 34-111-24855
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Switzerland Township
Operator Name: ECLIPSE RESOURCES I LP
Well Pad ID: US-OH-001589
Farm/Lease Name: PITTMAN
License Status: Drilling
License Date: 2018-11-13
Spud Date: 2018-12-01
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Horizontal
Latitude: 39.798171086
Longitude: -80.96298805

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2018-11-13 Proposed Formations:UTICA/POINT PLEASANT, Issued Date:11/13/2018, Expired Date:11/12/2020 12:00:00 PM, Drilling unit acres:665.903, Proposed Well Type:OG, Proposed Well Class:POOL
Record Last Modified 2018-12-04
Construction Permit Expires 2020-11-12

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1371526661 2018-12-02 Casing String Witnessed No Violations On site inspection at 14:45 hours to witness the conductor casing cement job that was called out for 15:00 hours. Upon arrival it was observed that Precision Drilling had (2) auger rigs on location and had drilled both the Craig Miller A 4-H and the Pittman 2-H conductor boreholes to a measured depth of 120 from ground level elevation. The conductor boreholes were 30 in diameter and the rigs inserted 24 diameter .375 wall casing into the well bores. The well bores did have surface water in them to elevation. C&J Cement Service arrived on location at 17:30 hours and commenced to cementing the casing using a 56 barrel cement mx consisting of 305 sacks of class A cement. The cement weight was verified by weight of scale at 15.6 pound per gallon. The cement yield was 1.2 with 50% cement excess ran and the cement displaced to 110 with 57 barrels of fresh water. 15 barrels of cement returns were witnessed to surface.

For data sources see[3]

References