Revision as of 11:33, 26 July 2019

Well Details

Well ID: 34-005-22660
Loading map...
Country: United States
State: Ohio
County: Ashland
Municipality: Mifflin Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: THE OHIO GAS CO
License Status: Storage Well
License Date: 1968-06-20
Spud Date: 1968-06-22
Spud Drilling Contractor:
Final Drill Date: 1968-08-16
Well Total Depth: 2624 ft
Configuration: Vertical
Latitude: 40.790556811
Longitude: -82.36678181

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1968-06-22
Completed 1968-08-16
Reached Total Depth 1968-08-16
Record Last Modified 2013-05-23

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0172598927 2018-05-01 Storage Well No Violations ID is posted and the location is maintained. The well is shut in at the gate valve; the annulus is open. The well is equipped with a separator.
0690445076 2015-08-05 Storage Well No Violations ID is posted and the location is maintained. The well is shut in at the side gate valve. The backside valves are open.
1046456206 2016-06-22 Storage Well No Violations ID is posted and the location is maintained. The well is shut in at the gate valve; the annulus is open. The well is equipped with a separator.
1128233109 2013-11-20 Storage Well No Violations ID posted, location maintained.
1172800099 2017-05-17 Storage Well No Violations ID is posted and the location is maintained. The well is shut in at the gate valve; the annulus is open. The well is equipped with a separator.
1835313918 2014-10-01 Storage Well No Violations ID posted, location maintained. The side gate valve is closed.
2051110686 2019-03-08 Storage Well No Violations Performed annual inspection for Columbia Gas Storage Well #10779 on 03/08/2019. The well is equipped with a flanged wellhead with 1-master valve and 1-wing valve, and a drip. Well identification is clearly displayed. No problems were noted at the time of the inspection.