If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 21: | Line 21: | ||
| License Status: Producing | | License Status: Producing | ||
|- | |- | ||
− | | License Date: | + | | License Date: |
|- | |- | ||
| Spud Date: 1966-06-04 | | Spud Date: 1966-06-04 |
Well ID: 34-127-20466 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.814113298,"lon":-82.21824517,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Perry | |
Municipality: Clayton Township | |
Operator Name: R C POLING CO INC | |
Well Pad ID: | |
Farm/Lease Name: GROOM THOMAS | |
License Status: Producing | |
License Date: | |
Spud Date: 1966-06-04 | |
Spud Drilling Contractor: | |
Final Drill Date: 1966-06-23 | |
Well Total Depth: 3332 ft | |
Configuration: Vertical | |
Latitude: 39.814113298 | |
Longitude: -82.21824517 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1966-06-04 | RE-OPEN 3-31-66, GL=1022.1 I.P.NAT. O & G, FOUND IN NSR. PF/GRIT |
Completed | 1966-06-23 | RE-OPEN 3-31-66, GL=1022.1 I.P.NAT. O & G, FOUND IN NSR. PF/GRIT |
Reached Total Depth | 1966-06-23 | RE-OPEN 3-31-66, GL=1022.1 I.P.NAT. O & G, FOUND IN NSR. PF/GRIT |
CO | 1987-01-15 | 360 RELIANCE ENERGY INC |
CO | 1996-05-17 | 5236 S&E OILFIELD OPERATIONS GeoDate |
Change of Owner | 2004-06-18 | Operator changed from 5236, S & E OILFIELD OPERATIONS to 7323, PILOT ENERGY LLC |
Change of Owner | 2013-01-24 | Operator changed from 7323, PILOT ENERGY LLC to 236, POLING R C CO INC |
Record Last Modified | 2019-06-04 | RE-OPEN 3-31-66, GL=1022.1 I.P.NAT. O & G, FOUND IN NSR. PF/GRIT |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1000 Bbl | 15000 |
For data sources see[3]
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | RELIANCE OIL CORP | Brine | 0 | 365 |
1985 | RELIANCE OIL CORP | Brine | 0 | 0 |
1986 | DUGAN GUY E | Brine | 0 | 365 |
1987 | RELIANCE ENERGY INC | Brine | 0 | 365 |
1988 | RELIANCE ENERGY INC | Brine | 0 | 365 |
1989 | RELIANCE ENERGY INC | Brine | 0 | 365 |
1990 | RELIANCE ENERGY INC | Brine | 0 | 365 |
1991 | RELIANCE ENERGY INC | Brine | 0 | 365 |
1992 | RELIANCE ENERGY INC | Brine | 0 | 365 |
1993 | RELIANCE ENERGY INC | Brine | 0 | 365 |
1994 | RELIANCE ENERGY INC | Brine | 0 | 365 |
1995 | RELIANCE ENERGY INC | Brine | 0 | 365 |
1996 | RELIANCE ENERGY INC | Brine | 0 | 120 |
1997 | S & E OILFIELD OPERATIONS | Brine | 0 | 365 |
1998 | S & E OILFIELD OPERATIONS | Brine | 0 | 365 |
1999 | S & E OILFIELD OPERATIONS | Brine | 0 | 365 |
2000 | S & E OILFIELD OPERATIONS | Brine | 0 | 365 |
2001 | S & E OILFIELD OPERATIONS | Brine | 0 | 365 |
2004 | PILOT ENERGY LLC | Brine | 0 | 365 |
2005 | PILOT ENERGY LLC | Brine | 0 | 365 |
2006 | PILOT ENERGY LLC | Brine | 0 | 365 |
2007 | PILOT ENERGY LLC | Brine | 0 | 365 |
2008 | PILOT ENERGY LLC | Brine | 0 | 365 |
2009 | PILOT ENERGY LLC | Brine | 0 | 365 |
2010 | PILOT ENERGY LLC | Brine | 0 | 365 |
2011 | PILOT ENERGY LLC | Brine | 0 | 365 |
2012 | PILOT ENERGY LLC | Brine | 0 | 366 |
2013 | R C POLING CO INC | Brine | 0 | 365 |
2014 | R C POLING CO INC | Brine | 0 | 365 |
2015 | R C POLING CO INC | Brine | 0 | 365 |
2016 | R C POLING CO INC | Brine | 0 | 365 |
2017 | R C POLING CO INC | Brine | 20 | 365 |
2018 | R C POLING CO INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0724210561 | 2017-08-02 | Work Over Reconditioning | No Violations | I stopped by this well today to do a field inspection on it. Knox Energy has there service rig on location to service this well. They have pulled the rods and tubing out of the well to clean it out. At this point they ran the tubing and rods back in the well but it would not pump so they just finished pulling the rods back out and dropped a standing valve to bottom to pressure test the tubing. Once this is done they will run a new pump to bottom and try to pump the well again. |
0921210566 | 2017-04-10 | Production Wells | Violations Noted | I am on location today to do a field inspection on this well. The well appears to be capable of production with a pumping unit on it with rods and 2 inch diameter tubing down hole. The valves coming off of the wellhead to the production tank is open. At this time there is no identification at the well or the production tank. I contacted Zack Poling by phone to let him know the well needs to have identification either on the well or the production tank. Zack stated he would get it taken care of. |
1222189702 | 2018-04-17 | Production Wells | No Violations | I am on location today to do a field inspection on this well. The well appears to be capable of production with a pumping unit on it with rods and 2 inch diameter tubing down hole. The valves coming off of the wellhead to the production tank are open. The identification for the well is located on the production tank. There are no violations at this time. |
1416088892 | 2013-03-20 | Production Wells | Violations Noted | This well is capable of producing. It has a pumping unit on it with rods and tubing. The valve is open to the tank. There needs to be a pop off valve for the gas. |
1971740113 | 2013-07-02 | Production Wells | No Violations | The issue has been resolved. The well is now in-compliance. |
2112214990 | 2017-05-08 | Production Wells | No Violations | I returned to this well today to do a follow-up inspection on the identification for this well. The identification has been put on the production tank. The well is now in-compliance. There are no violations at this time. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0921210566 | US-OH-130529 | 2017-05-19 | 9-9-05(A)10 | Failure to legibly identify well |
1416088892 | US-OH-112213 | 2014-04-23 | Unlawful venting or flaring of gas |
For data sources see[8]