| License Status: Producing | | License Status: Producing | ||
|- | |- | ||
− | | License Date: | + | | License Date: 2008-06-04 |
|- | |- | ||
| Spud Date: 2008-09-10 | | Spud Date: 2008-09-10 |
Well ID: 34-167-29662 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.397331793,"lon":-81.4990475,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Washington | |
Municipality: Warren Township | |
Operator Name: HEINRICH ENTERPRISES INC DBA W | |
Well Pad ID: | |
Farm/Lease Name: WILFONG UNIT | |
License Status: Producing | |
License Date: 2008-06-04 | |
Spud Date: 2008-09-10 | |
Spud Drilling Contractor: G & L DRILLING | |
Final Drill Date: 2008-09-19 | |
Well Total Depth: 6360 ft | |
Configuration: Vertical | |
Latitude: 39.397331793 | |
Longitude: -81.49904750 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2008-06-04 | Proposed Formations:DEVONIAN SHALE THRU MEDINA, Issued Date:6/4/2008, Expired Date:6/4/2009 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:EOUT |
Reached Total Depth | 2008-09-19 | |
Completion Report Received | 2009-01-09 | |
Construction Permit Expires | 2009-06-04 | |
Record Last Modified | 2015-09-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2009-02-26 | 6120 | 6260 | 72 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 3000 Bbl | 55000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | HEINRICH ENTERPRISES INC DBA W | 0 | 0 | 0 |
2008 | HEINRICH ENTERPRISES INC DBA W | 0 | 0 | 0 |
2009 | HEINRICH ENTERPRISES INC DBA W | 5802 | 0 | 0 |
2010 | HEINRICH ENTERPRISES INC DBA W | 2231 | 0 | 365 |
2011 | HEINRICH ENTERPRISES INC DBA W | 1574 | 0 | 0 |
2012 | HEINRICH ENTERPRISES INC DBA W | 1057 | 0 | 366 |
2013 | HEINRICH ENTERPRISES INC DBA W | 905 | 0 | 365 |
2014 | HEINRICH ENTERPRISES INC DBA W | 721 | 0 | 365 |
2015 | HEINRICH ENTERPRISES INC DBA W | 467 | 0 | 365 |
2016 | HEINRICH ENTERPRISES INC DBA W | 346 | 0 | 365 |
2017 | HEINRICH ENTERPRISES INC DBA W | 587 | 0 | 365 |
2018 | HEINRICH ENTERPRISES INC DBA W | 537 | 0 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | HEINRICH ENTERPRISES INC DBA W | Brine | 0 | 0 |
2008 | HEINRICH ENTERPRISES INC DBA W | Brine | 1219 | 0 |
2009 | HEINRICH ENTERPRISES INC DBA W | Brine | 2459 | 0 |
2010 | HEINRICH ENTERPRISES INC DBA W | Brine | 0 | 365 |
2011 | HEINRICH ENTERPRISES INC DBA W | Brine | 274 | |
2012 | HEINRICH ENTERPRISES INC DBA W | Brine | 0 | 366 |
2013 | HEINRICH ENTERPRISES INC DBA W | Brine | 0 | 365 |
2014 | HEINRICH ENTERPRISES INC DBA W | Brine | 0 | 365 |
2015 | HEINRICH ENTERPRISES INC DBA W | Brine | 210 | 365 |
2016 | HEINRICH ENTERPRISES INC DBA W | Brine | 0 | 365 |
2017 | HEINRICH ENTERPRISES INC DBA W | Brine | 0 | 365 |
2018 | HEINRICH ENTERPRISES INC DBA W | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0404965479 | 2009-12-07 | Preliminary Restoration | No Violations | Inspection this day found area around the well hasnow been seeded and mulched, which they were originally refusing to do. Also area below location along the lease road is seeded and mulched where water bars were cut - should take care of any problems. Will wait until Spring to see if grass grows but should fix the problemand they have made the effort. |
1131667592 | 2008-09-22 | Drill / Deepen / Reopen | No Violations | Inspection this day found rig gone, moved off well last week, pits still open, one containing oil. Called to see when they were going to get it emptied, water in the other one. Well has had casing cemented, waiting to be completed. |
1215606713 | 2009-08-06 | Preliminary Restoration | No Violations | Inspection this day found grass growing alittle better but still several large, bare spots. It has been 1 year since TD reached, well started producing in 1/09? Good IDs, good dike, still some equipment (a gas heater) sitting around not being used. Lease road rutted and asked them to smooth it as they dont want to plant in gas. Am working with them so will not write NOV at this time, only if |
1228758783 | 2008-12-08 | Preliminary Restoration | No Violations | Inspection this day found service rig at well, running tubing. Well producing from Clinton/Medina and making some water. Location has not been reclaimed yet. |
1256817784 | 2009-10-27 | Preliminary Restoration | No Violations | Inspection this day was meeting between Supervisor Stonerock, inspector VanDyke, Carl Heinrich, Christy and Brian Chavez to discuss reclamation still needed for well. Inspector felt grass needed to be growing on approx. 100 x 100 area at the well, they claim they have tried, cant grow grass there and need that much area to service well. They agreed to fix erosional problems on road running into well but refused to plant more grass seed on flat area between well and lease road. Location is still very rough, ground would be very rough to mow with a tractor and due to new housing development going in next door, inspector felt location should look better. They have removed the heater that was being stored on location but gave numerous excuses as to why they couldnt fix road better. Will continue to monitor but cannot pass at this time. |
1499218588 | 2009-10-20 | Preliminary Restoration | No Violations | |
1542454698 | 2009-07-14 | Preliminary Restoration | No Violations | Inspection this day due to PRD - still does not look good enough to pass but will ask Supervisor to look at. 100 bbl lay down brine tank - is it being used? - and heater for gas nearby that needs removed. Good IDs, good dike, appear to be hauling their brine. 7/15/09 Looked at location with Supervisor -- told her what else needed done before could pass inspection. We offered to meet out there on 7/17 to discuss, Khristy said they would be out of town, were going out on 7/16 to give additional work to location. |
1597205051 | 2009-11-10 | Preliminary Restoration | No Violations | Inspection this day found erosion coming up onto location has been fixed, scuffed up with dozer and filled in with large rock, ground around the well and between the well and erosion (the edge of location) has also been scuffed up and any grass that was growing has been destroyed. Not sure if they are going to reseed or not. Did add a water bar or ditch at base of slope and another water bar half way up and I think that will fix the problem. Should have done that initially. |
1625501601 | 2009-06-10 | Preliminary Restoration | No Violations | Inspection found location has been reclaimed - am not going to pass today as grass very sparse, still holes where water standing, location should have been smoothed better and lines buried but were not. Tank needs IDs, current chart in meter, lease road very muddy and rutted, probably need culvert. May eventually pass it but too early now to see how it will grow in and cover. |
For data sources see[9]