X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-055-22152"

m
 
m
Line 21: Line 21:
 
| License Status: Producing
 
| License Status: Producing
 
|-
 
|-
| License Date: 2016-06-14
+
| License Date: 2016-01-04
 
|-
 
|-
 
| Spud Date: 2016-01-21
 
| Spud Date: 2016-01-21

Revision as of 13:43, 30 July 2019

Well Details

Well ID: 34-055-22152
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Troy Township
Operator Name: DISCOVERY OIL AND GAS
Well Pad ID:
Farm/Lease Name: MATLOCK
License Status: Producing
License Date: 2016-01-04
Spud Date: 2016-01-21
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2016-01-26
Well Total Depth: 4318 ft
Configuration: Vertical
Latitude: 41.365922304
Longitude: -81.18930000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2016-01-04 Proposed Formations:CLINTON, Issued Date:1/4/2016, Expired Date:1/3/2018 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:NWC
Reached Total Depth 2016-01-26
Completion Report Received 2016-06-30
Construction Permit Expires 2018-01-03
Record Last Modified 2018-07-24

For data sources see[2]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 02/17/2016 02/17/2016 4318 90182

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand (Proppant) Reliance Well Services, LLC Proppant Listed Below
ParaClear Reliance Well Services, LLC Paraffin Dispersant Listed Below
AI-600 Reliance Well Services, LLC Acid Inhibitor Listed Below
Water Reliance Well Services, LLC Carrier/Base Fluid Listed Below
CC-200 Reliance Well Services, LLC Stimulation Clay Control Listed Below
WGA-15 Reliance Well Services, LLC Water Geling Agent Listed Below
BioClear 1000 Reliance Well Services, LLC Biocide Listed Below
FRA-409 Reliance Well Services, LLC Friction Reducer Listed Below
Sand 14808-60-7 100 3.92993 600
Cinnamaldehyde 104-55-2 10 0.02339 4
Hydrochloric acid 7647-01-0 7.5 2.41865 369
Nonyl Phenol Ethoxylate, Branched 127087-87-0 10 0.02339 4
2-Butoxyethanol 111-76-2 10 0.02339 4
Hydrochloric acid 7647-01-0 15 5.80476 886
Ethylene glycol 107-21-1 40 0.09358 14
Water 7732-18-5 100 0 0
N,N-dimethylformamide 68-12-2 20 0.04679 7
ICA-400 Reliance Well Services, LLC Iron Control Agent Listed Below
Surf-Max 100NE Reliance Well Services, LLC Non-emulsifier Listed Below
Hydrochloric Acid Reliance Well Services, LLC Acidizing Listed Below

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2016 DISCOVERY OIL AND GAS 8902 358 270
2017 DISCOVERY OIL AND GAS 10425 1532 365
2018 DISCOVERY OIL AND GAS 11549 1218 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2016 DISCOVERY OIL AND GAS Brine 2587 270
2017 DISCOVERY OIL AND GAS Brine 252 365
2018 DISCOVERY OIL AND GAS Brine 134 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0148821780 2016-01-26 Casing String Witnessed No Violations

-Tex was the cement contractor on location. O-Tex broke circulation and pumped 250 sacks of Class A Cement that mudscaled at 14.4 ppg. The plug was displaced using 66 BBLs of water. The plug landed at 450 psi. Pressure was held for 5 minutes. The pressure was released and the plug held. The location is in stable condition. The pit liner is in good repair. No violations found.

0692045249 2016-01-21 Drill / Deepen / Reopen No Violations I was notified by Larry Poulson of Poulson Drilling that they would be spudding the well at 10:00 AM on 01/21/16.
0940511954 2018-06-12 Production Wells No Violations At the time of this inspection, the well was equipped with a plunger lift assembly. The gate valve on the tubing and the 2 inch flow line valve was open. The production records for this well were current. The tank battery consisted of one 210 BBL tank, one 100 BBL tank, one 50 BBL tank, and a mechanical separator. Valves on the separator were open. The tank battery was diked. Legible signage was located at the well and tank battery. The lease access was stable. No violations observed.
1333213295 2016-05-03 Preliminary Restoration No Violations My inspection found the tank battery has been installed. The tank battery consists of a 210 BBL production tank, a 100 BBL production tank, a 50 BBL poly brine tank, and a mechanical separator. The sales line has recently been completed. The company is still in the process of final grading the location. Once vegetation is established preliminary restoration can be passed.
1453922294 2016-01-22 Casing String Witnessed No Violations
1454509327 2016-01-29 Completion Testing No Violations I was notified by the company that they had installed a guage on the annulus to monitor the pressure for the 5 day test period. The guage is currently reading 0 psi. I will return on 2/3/16 to check the pressure to complete the 5 day test. No changes to the location since my last inspection. Pits are in stable condition and are scheduled to be closed on 2/5/16. No violations found.
1458122548 2016-02-09 Preliminary Restoration No Violations My inspection found the pits have been solidified and closed. Dailey Excavating is on location cutting trees into firewood and chipping the smaller brush and trees. The well is scheduled to be perforated on 2/15/16. The lease road and location is in stable condition. No violations found.
1707812427 2016-02-04 Preliminary Restoration No Violations I was notified by Kelly Dailey of Dailey Excavating that he would be solidifying and closing the pits, starting on 2/5/16.
1841808804 2016-02-03 Completion Testing No Violations My inspection found the guage on the annulus to be at 0 psi. The five day annular test showed no increase in pressure on the annulus. No changes to the location since my last inspection. Pits are in stable condition and are scheduled to be closed on 2/5/16. No violations found.

For data sources see[8]

References