X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-059-24337"

m
m
Line 1: Line 1:
__TOC__
+
__TOC__
 
== Well Details ==
 
== Well Details ==
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-059-24337
 
| Well ID: 34-059-24337
| style="height=100%; align=center" rowspan="15" | {{#display_map: 39.9782875, -81.42024933 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 39.978216129, -81.42040948 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Guernsey County, Ohio|Guernsey]]
+
| Country: United States
 
|-
 
|-
| Municipality:  
+
| State: Ohio
 
|-
 
|-
| Operator Name: [[PDC ENERGY INC]]
+
| County: [[Guernsey_County,_Ohio|Guernsey]]
 
|-
 
|-
| Well Pad ID:  
+
| Municipality: [[Richland_Township,_Guernsey_County,_Ohio|Richland Township]]
 
|-
 
|-
| Farm/Lease Name:  
+
| Operator Name: [[UTICA RESOURCE OPERATING LLC]]
 
|-
 
|-
| First Permit Date:  
+
| Well Pad ID: [[US-OH-000877]]
 
|-
 
|-
| Last Permit Date:  
+
| Farm/Lease Name: DYNAMITE
 +
|-
 +
| License Status: Producing
 +
|-
 +
| License Date: 2014-02-24
 
|-
 
|-
 
| Spud Date: 2014-03-22
 
| Spud Date: 2014-03-22
 
|-
 
|-
| Unconventional: No
+
| Spud Drilling Contractor: [[H&P DRILLING]]
 
|-
 
|-
| Configuration: Vertical
+
| Final Drill Date: 2014-09-05
 
|-
 
|-
| Well Status: Producing
+
| Well Total Depth: 13780 ft
 
|-
 
|-
| Violations: 0
+
| Configuration: Horizontal
 
|-
 
|-
| Latitude: 39.9782875
+
| Latitude: 39.978216129
|-
 
| Longitude: -81.42024933
 
 
|-
 
|-
 +
| Longitude: -81.42040948
 
|}
 
|}
== Production Data ==
+
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" style="text-align: center"| Well Status
!scope="col" | GAS QUANTITY
+
!scope="col" style="width: 15%;text-align: center"| Well Status Date
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" style="text-align: center"| Comment
!scope="col" | CONDENSATE QUANTITY
+
|-
!scope="col" | CONDENSATE PRODUCTION DAYS
+
| APP
!scope="col" | OIL QUANTITY
+
| 2014-02-24
!scope="col" | OIL PRODUCTION DAYS
+
| Proposed Formations:POINT PLEASANT, Issued Date:2/24/2014, Expired Date:2/24/2016 12:00:00 PM, Drilling unit acres:560.836, Proposed Well Type:OG, Proposed Well Class:POOL
 
|-
 
|-
| 2015-1
+
| Reached Total Depth
| style="text-align:right;" | 103781.0
+
| 2014-09-05
| style="text-align:right;" | 88.0
+
 
|
 
|
 
| style="text-align:right;" | 28208.0
 
| style="text-align:right;" | 88.0
 
 
|-
 
|-
 +
| Completion Report Received
 +
| 2015-07-23
 +
 
|-
 
|-
| 2014-4
+
| Construction Permit Expires
| style="text-align:right;" | 16518.0
+
| 2016-02-24
| style="text-align:right;" | 13.0
+
 
|  
+
|-
|  
+
| Correction to Well
| style="text-align:right;" | 4513.0
+
| 2016-10-21
| style="text-align:right;" | 13.0
+
| CHANGE IN TARGET/TAKEPOINT/ACREAGE PER AS DRILLED PLAT RCVD 10/19/16-ALE
 +
|-
 +
| Change of Owner
 +
| 2018-05-04
 +
| Operator changed from 8595, PDC ENERGY INC to 10114, UTICA RESOURCE OPERATING LLC
 +
|-
 +
| Record Last Modified
 +
| 2018-05-04
 +
 
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Ohio Department of Natural Resources RBDMS
+
  | title = Risk Based Data Management System - Well and WellHistry Tables
  | publisher = [http://oilandgas.ohiodnr.gov/]
+
  |publisher = [[Ohio Department of Natural Resources]]
  | date = 2015-06-19
+
  | date = 2019-05-07
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Production
+
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2015-06-20 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
== Inspection Data ==
+
<!--== Perforation Treatments ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" style="text-align: center"| Perforation Date
!scope="col" | DATE
+
!scope="col" style="text-align: center"| Interval Top (ft)
!scope="col" | DESCRIPTION
+
!scope="col" style="text-align: center"| Interval Base (ft)
!scope="col" | COMMENT
+
!scope="col" style="text-align: center"| Number of Shots
!scope="col" | VIOLATION ID
 
!scope="col" | VIOLATION CODE
 
!scope="col" | VIOLATION COMMENT
 
 
|-
 
|-
| 1212700983
+
|}-->
| 2014-03-25
+
== Fracking Activities ==
|  
+
==== Fracking Jobs ====
| On the day of my inspection I witnessed that Express Energy Services had drilled a 36 inch diameter hole to the depth of 115 feet and set 115 feet of 30 inch conductor pipe. Express Energy could not get conductor pipe plum. They are pulling pipe back out and will ream hole to 42 inches in diameter and rerun pipe and cement tomorrow.
+
{| class="wikitable sortable" width="95%"
|  
+
!scope="col" style="text-align: center"| Job Number
|  
+
!scope="col" style="text-align: center"| Job Start Date
|  
+
!scope="col" style="text-align: center"| Job End Date
 +
!scope="col" style="text-align: center"| True Vertical Depth (ft)
 +
!scope="col" style="text-align: center"| Total Water Volume (gal)
 +
!scope="col" style="text-align: center"| Total Non-Water Volume (gal)
 
|-
 
|-
 +
| 1
 +
| 10/19/2014
 +
| 11/12/2014
 +
| style="text-align: right;" | 7205
 +
| style="text-align: right;" | 9,398,160.0
 +
| style="text-align: right;" | 0
 
|-
 
|-
| -175625523
+
|}
| 2014-09-07
+
==== Fluid Composition Data ====
|  
+
{| class="wikitable sortable" style="width: 100%"
| On the day of my inspection I witnessed that the site passed preliminary restoration according to ORC 1509.072A.
+
!scope="col" style="text-align: center"| Job Number
|  
+
!scope="col" style="text-align: center"| Trade Name
|  
+
!scope="col" style="text-align: center"| Supplier
|  
+
!scope="col" style="text-align: center"| Purpose
 +
!scope="col" style="text-align: center"| Ingredient Name
 +
!scope="col" style="white-space: nowrap;text-align: center"| CAS Number
 +
!scope="col" style="text-align: center"| Additive Percentage by Mass
 +
!scope="col" style="text-align: center"| Job Percentage by Mass
 +
!scope="col" style="text-align: center"| Mass Used (lb)
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="43"| 1
 +
| rowspan="1"| SP BREAKER
 +
| rowspan="1"| Halliburton
 +
| rowspan="1"| Breaker
 +
| Sodium persulfate
 +
| 7775-27-1
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 0.00159865
 +
| style="text-align: right;" | 1433
 
|-
 
|-
| -226322298
+
|- valign="top"
| 2014-06-23
+
| rowspan="1"| FR-66
|
+
| rowspan="1"| Halliburton
| On the day of my inspection, I witnessed Universal break circulation with fresh water then mix and displace five hundred forty two barrel of Type-1 cement to a depth of 315 foot, I witnessed 20 barrels of cement returns to surface with a weight of 15.6 and a yield of 1.20. My site inspection revealed no erosion and good vegetation, no spills to report and all fluid storage is setting inside containment.
+
| rowspan="1"| Friction Reducer
|
 
|
 
|
 
|-
 
|}
 
For data sources see<ref>{{cite web
 
| title = Ohio Department of Natural Resources RBDMS
 
| publisher = [http://oilandgas.ohiodnr.gov/]
 
| date = 2015-06-19
 
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection
 
| accessdate = 2015-06-20 }}</ref>
 
[[Category:Has Chemical Data]]
 
==Chemical Data==
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | HF Fluid Concentration
 
!scope="col" | Ingredient
 
!scope="col" | Additive Concentration
 
!scope="col" | Trade Name
 
!scope="col" | Purpose
 
!scope="col" | CAS number
 
!scope="col" | Supplier
 
|-
 
| 0.0115683
 
 
| Hydrotreated light petroleum distillate
 
| Hydrotreated light petroleum distillate
| 30.0
 
| FR-66
 
| Friction Reducer
 
 
| 64742-47-8
 
| 64742-47-8
| Halliburton
+
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.0115683
 +
| style="text-align: right;" | 10364
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| WG-36 GELLING AGENT
 +
| rowspan="1"| Halliburton
 +
| rowspan="1"| Gelling Agent
 +
| Guar gum
 +
| 9000-30-0
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 0.0704475
 +
| style="text-align: right;" | 63108
 
|-
 
|-
| 0.000385609
+
|- valign="top"
| Sorbitan monooleate polyoxyethylene derivative
+
| rowspan="2"| BC-140
| 0.0
+
| rowspan="2"| Halliburton
|  
+
| rowspan="2"| Crosslinker
| Other Ingredient(s)
+
| Ethylene glycol
| 9005-65-6
+
| 107-21-1
|  
+
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.0270769
 +
| style="text-align: right;" | 24256
 
|-
 
|-
 +
| Monoethanolamine borate
 +
| 26038-87-9
 +
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.0541539
 +
| style="text-align: right;" | 48512
 
|-
 
|-
| 0.00126202
+
|- valign="top"
| Sodium sulfate
+
| rowspan="2"| OPTIFLO-HTE
| 0.0
+
| rowspan="2"| Halliburton
|  
+
| rowspan="2"| Breaker
| Other Ingredient(s)
+
| Walnut hulls
| 7757-82-6
+
| NA
|  
+
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 0.00308311
 +
| style="text-align: right;" | 2762
 
|-
 
|-
 +
| Crystalline silica, quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.000924933
 +
| style="text-align: right;" | 829
 
|-
 
|-
| 0.000154155
+
|- valign="top"
| Enzyme
+
| rowspan="26"|
| 0.0
+
| rowspan="26"|
|  
+
| rowspan="26"| Other Ingredient(s)
| Other Ingredient(s)
+
| Olefins
 
| Confidential
 
| Confidential
|  
+
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00000546
 +
| style="text-align: right;" | 5
 
|-
 
|-
 +
| 2,7-Naphthalenedisulfonic acid, 5-(acetylamino) -4-hydroxy-3-[(2-methoxyphenyl) azo] -, disodium salt
 +
| 6625-46-3
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00000252
 +
| style="text-align: right;" | 3
 
|-
 
|-
| 0.00192805
+
| Silica gel
| Fatty acid tall oil amide
+
| 112926-00-8
| 0.0
+
| style="text-align: right;" | 0
|  
+
| style="text-align: right;" | 0.000704475
| Other Ingredient(s)
+
| style="text-align: right;" | 632
| Confidential
+
|-
|  
+
| Sorbitan, mono-9-octadecenoate, (Z)
 +
| 1338-43-8
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.000385609
 +
| style="text-align: right;" | 346
 
|-
 
|-
 +
| Alcohols, C12-16, ethoxylated
 +
| 68551-12-2
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00192805
 +
| style="text-align: right;" | 1728
 
|-
 
|-
| 0.00192805
+
| Fatty acids, tall oil
| Sodium chloride
+
| Confidential
| 0.0
+
| style="text-align: right;" | 0
|  
+
| style="text-align: right;" | 0.000163781
| Other Ingredient(s)
+
| style="text-align: right;" | 147
| 7647-14-5
 
|  
 
 
|-
 
|-
 +
| Crystalline Silica, Quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00007045
 +
| style="text-align: right;" | 64
 
|-
 
|-
| 0.000704475
 
 
| Surfactant mixture
 
| Surfactant mixture
| 0.0
 
|
 
| Other Ingredient(s)
 
 
| Confidential
 
| Confidential
|  
+
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.000704475
 +
| style="text-align: right;" | 632
 +
|-
 +
| Food red 10
 +
| 3734-67-6
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00000252
 +
| style="text-align: right;" | 3
 
|-
 
|-
 +
| Alcohols, C14-C15, ethoxylated
 +
| 68951-67-7
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.000163781
 +
| style="text-align: right;" | 147
 
|-
 
|-
| 1338.0
+
| Reaction product of acetophenone, formaldehyde, thiourea and oleic acid in dimethyl formamide
| Sorbitan
+
| 68527-49-1
| 0.0
+
| style="text-align: right;" | 0
|  
+
| style="text-align: right;" | 0.000163781
| Other Ingredient(s)
+
| style="text-align: right;" | 147
| mono-9-octadecenoat
 
|  
 
 
|-
 
|-
 +
| Propylene glycol
 +
| 57-55-6
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.013227
 +
| style="text-align: right;" | 11849
 
|-
 
|-
| 68551.0
+
| Cured acrylic resin
| Alcohols
+
| Confidential
| 0.0
+
| style="text-align: right;" | 0
|  
+
| style="text-align: right;" | 0.000924933
| Other Ingredient(s)
+
| style="text-align: right;" | 829
| C12-16
 
|  
 
 
|-
 
|-
 +
| Bentonite, benzyl(hydrogenated tallow alkyl) dimethylammonium stearate complex
 +
| 121888-68-4
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00352237
 +
| style="text-align: right;" | 3156
 
|-
 
|-
| 0.00159865
+
| Fatty acid tall oil amide
| Sodium persulfate
+
| Confidential
| 100.0
+
| style="text-align: right;" | 0
| SP BREAKER
+
| style="text-align: right;" | 0.00192805
| Breaker
+
| style="text-align: right;" | 1728
| 7775-27-1
 
| Halliburton
 
 
|-
 
|-
 +
| C.I. Pigment Red 5
 +
| 6410-41-9
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00003083
 +
| style="text-align: right;" | 28
 
|-
 
|-
| 0.00308311
+
| Olefins
| Walnut hulls
+
| Confidential
| 100.0
+
| style="text-align: right;" | 0
| OPTIFLO-HTE
+
| style="text-align: right;" | 0.00002730
| Breaker
+
| style="text-align: right;" | 25
| NA
 
| Halliburton
 
 
|-
 
|-
 +
| Enzyme
 +
| Confidential
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.000154155
 +
| style="text-align: right;" | 139
 
|-
 
|-
| 0.0704475
+
| Polyacrylamide copolymer
| Guar gum
+
| Confidential
| 100.0
+
| style="text-align: right;" | 0
| WG-36 GELLING AGENT
+
| style="text-align: right;" | 0.0115683
| Gelling Agent
+
| style="text-align: right;" | 10364
| 9000-30-0
 
| Halliburton
 
 
|-
 
|-
 +
| Sorbitan monooleate polyoxyethylene derivative
 +
| 9005-65-6
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.000385609
 +
| style="text-align: right;" | 346
 
|-
 
|-
| 0.0
+
| Ammonium chloride
| 2
+
| 12125-02-9
| 3.0
+
| style="text-align: right;" | 0
|  
+
| style="text-align: right;" | 0.00192805
| Other Ingredient(s)
+
| style="text-align: right;" | 1728
| 7-Naphthalenedisulfo
 
|  
 
 
|-
 
|-
 +
| Sodium chloride
 +
| 7647-14-5
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00192805
 +
| style="text-align: right;" | 1728
 
|-
 
|-
| 3.08311e-05
 
 
| Cured acrylic resin
 
| Cured acrylic resin
| 0.0
 
|
 
| Other Ingredient(s)
 
 
| Confidential
 
| Confidential
|  
+
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00003083
 +
| style="text-align: right;" | 28
 +
|-
 +
| 2,7-Naphthalenedisulfonic acid, 3-hydroxy-4-[(4-sulfor-1-naphthalenyl) azo] -, trisodium salt
 +
| 915-67-3
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00000252
 +
| style="text-align: right;" | 3
 
|-
 
|-
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.783397
 +
| style="text-align: right;" | 701780
 
|-
 
|-
| 2.72969e-05
+
| Sodium sulfate
| Olefins
+
| 7757-82-6
| 0.0
+
| style="text-align: right;" | 0
|  
+
| style="text-align: right;" | 0.00126202
| Other Ingredient(s)
+
| style="text-align: right;" | 1131
| Confidential
+
|-
|  
+
|- valign="top"
 +
| rowspan="1"| 100 Mesh - COMMON WHITE
 +
| rowspan="1"| Halliburton
 +
| rowspan="1"| Proppant
 +
| Crystalline silica, quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 1.02559
 +
| style="text-align: right;" | 918741
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| HYDROCHLORIC ACID 5-10%
 +
| rowspan="1"| Halliburton
 +
| rowspan="1"| Solvent
 +
| Hydrochloric acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.0634894
 +
| style="text-align: right;" | 56875
 
|-
 
|-
| 0.783397
+
|- valign="top"
| Water
+
| rowspan="1"| Fresh Water
| 0.0
+
| rowspan="1"| Operator
|  
+
| rowspan="1"| Base Fluid
| Other Ingredient(s)
+
| Fresh Water
 
| 7732-18-5
 
| 7732-18-5
|  
+
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 87.3911
 +
| style="text-align: right;" | 78,286,400.0
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| SCALECHEK LP-55 SCALE INHIBITOR
 +
| rowspan="1"| Halliburton
 +
| rowspan="1"| Scale Inhibitor
 +
| Polyacrylate
 +
| Confidential
 +
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.0151251
 +
| style="text-align: right;" | 13550
 
|-
 
|-
| 0.0
+
|- valign="top"
| 2
+
| rowspan="1"| HYDROCHLORIC ACID 10-30%
| 5.0
+
| rowspan="1"| Halliburton
|  
+
| rowspan="1"| Solvent
| Other Ingredient(s)
+
| Hydrochloric acid
| 7-Naphthalenedisulfo
+
| 7647-01-0
|  
+
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.00149528
 +
| style="text-align: right;" | 1340
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| BE-9W
 +
| rowspan="1"| Halliburton
 +
| rowspan="1"| Biocide
 +
| Tributyl tetradecyl phosphonium chloride
 +
| 81741-28-8
 +
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00220449
 +
| style="text-align: right;" | 1975
 
|-
 
|-
| 5.45938e-06
+
|- valign="top"
| Olefins
+
| rowspan="1"| 30/50 - PREMIUM WHITE
| 0.0
+
| rowspan="1"| Halliburton
|  
+
| rowspan="1"| Proppant
| Other Ingredient(s)
+
| Crystalline silica, quartz
| Confidential
+
| 14808-60-7
|  
+
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 10.6727
 +
| style="text-align: right;" | 9,560,790.0
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="2"| HAI-OS ACID INHIBITOR
 +
| rowspan="2"| Halliburton
 +
| rowspan="2"| Corrosion Inhibitor
 +
| Propargyl alcohol
 +
| 107-19-7
 +
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00005459
 +
| style="text-align: right;" | 49
 
|-
 
|-
| 0.00189753
+
| Methanol
 +
| 67-56-1
 +
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.000327563
 +
| style="text-align: right;" | 294
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| BE-9
 +
| rowspan="1"| Halliburton
 +
| rowspan="1"| Biocide
 
| Tributyl tetradecyl phosphonium chloride
 
| Tributyl tetradecyl phosphonium chloride
| 10.0
 
| BE-9
 
| Biocide
 
 
| 81741-28-8
 
| 81741-28-8
| Halliburton
+
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00189753
 +
| style="text-align: right;" | 1700
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 +
<!--== Stimulations Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Stimulation Date
 +
!scope="col" style="text-align: center"| Chemical Agent
 +
!scope="col" style="text-align: center"| Chemical Agent Concentration (%)
 +
!scope="col" style="text-align: center"| Fracking Fluid Volume
 +
!scope="col" style="text-align: center"| Mass of Proppant Used (lb)
 +
!scope="col" style="text-align: center"| Fracking Company
 +
!scope="col" style="text-align: center"| Comments
 
|-
 
|-
 +
|}-->
 +
== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Gas Quantity (mcf)
 +
!scope="col" style="text-align: center"| Oil Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 
|-
 
|-
| 0.0151251
+
| 2014
| Polyacrylate
+
| [[PDC ENERGY INC]]
| 60.0
+
| style="text-align: right;" | 16518
| SCALECHEK LP-55 SCALE INHIBITOR
+
| style="text-align: right;" | 4513
| Scale Inhibitor
+
| style="text-align: right;" | 13
| Confidential
+
|-
| Halliburton
+
| 2015
 +
| [[PDC ENERGY INC]]
 +
| style="text-align: right;" | 324317
 +
| style="text-align: right;" | 77269
 +
| style="text-align: right;" | 363
 +
|-
 +
| 2016
 +
| [[PDC ENERGY INC]]
 +
| style="text-align: right;" | 175151
 +
| style="text-align: right;" | 30592
 +
| style="text-align: right;" | 366
 
|-
 
|-
 +
| 2017
 +
| [[PDC ENERGY INC]]
 +
| style="text-align: right;" | 125198
 +
| style="text-align: right;" | 18106
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 87.3911
+
| 2018
| Fresh Water
+
| [[UTICA RESOURCE OPERATING LLC]]
| 100.0
+
| style="text-align: right;" | 88211
| Fresh Water
+
| style="text-align: right;" | 7444
| Base Fluid
+
| style="text-align: right;" | 288
| 7732-18-5
 
| Operator
 
 
|-
 
|-
 +
| 2019
 +
| [[UTICA RESOURCE OPERATING LLC]]
 +
| style="text-align: right;" | 25575
 +
| style="text-align: right;" | 2414
 +
| style="text-align: right;" | 68
 
|-
 
|-
| 0.0634894
+
|}
| Hydrochloric acid
+
For data sources see<ref>{{cite web
| 10.0
+
| title = Risk Based Data Management System - Production Table - Oil and Gas Data
| HYDROCHLORIC ACID 5-10%
+
|publisher = [[Ohio Department of Natural Resources]]
| Solvent
+
| date =  2019-05-07
| 7647-01-0
+
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
| Halliburton
+
| accessdate = 2019-05-21 }}</ref>
 +
<ref>{{cite web
 +
| title = Combined Production - Oil and Gas Data
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date = 2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Waste Data ==
 +
{| class="wikitable sortable"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Waste Type
 +
!scope="col" style="text-align: center"| Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 
|-
 
|-
 +
| 2014
 +
| [[PDC ENERGY INC]]
 +
| Brine
 +
| style="text-align: right;" | 3711
 +
| style="text-align: right;" | 13
 
|-
 
|-
| 0.013227
+
| 2015
| Propylene glycol
+
| [[PDC ENERGY INC]]
| 0.0
+
| Brine
|  
+
| style="text-align: right;" | 27569
| Other Ingredient(s)
+
| style="text-align: right;" | 363
| 57-55-6
 
|  
 
 
|-
 
|-
 +
| 2016
 +
| [[PDC ENERGY INC]]
 +
| Brine
 +
| style="text-align: right;" | 7170
 +
| style="text-align: right;" | 366
 
|-
 
|-
| 68527.0
+
| 2017
| Reaction product of acetophenone
+
| [[PDC ENERGY INC]]
| 0.0
+
| Brine
|  
+
| style="text-align: right;" | 4230
| Other Ingredient(s)
+
| style="text-align: right;" | 365
| formaldehyde
 
|  
 
 
|-
 
|-
 +
| 2018
 +
| [[UTICA RESOURCE OPERATING LLC]]
 +
| Brine
 +
| style="text-align: right;" | 1772
 +
| style="text-align: right;" | 197
 
|-
 
|-
| 68951.0
+
| 2019
| Alcohols
+
| [[UTICA RESOURCE OPERATING LLC]]
| 0.0
+
| Brine
|  
+
| style="text-align: right;" | 204
| Other Ingredient(s)
+
| style="text-align: right;" | 68
| C14-C15
 
|  
 
 
|-
 
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Production Table - Brine Data
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
<ref>{{cite web
 +
| title = Combined Production - Brine Data
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date = 2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Inspection ID
 +
!scope="col" style="text-align: center"| Inspection Date
 +
!scope="col" style="text-align: center"| Inspection Type
 +
!scope="col" style="text-align: center"| Inspection Result
 +
!scope="col" style="text-align: center"| Inspection Comments
 
|-
 
|-
| 0.00192805
+
| 0058954358
| Ammonium chloride
+
| 2018-08-16
| 0.0
+
| Production Wells
|  
+
| No Violations
| Other Ingredient(s)
+
| The purpose of my inspection was a status check. During my inspection the well was equipped with a plunger lift system with production valves in the open position. Gauges were present on all casing strings. The production equipment consisted of fifteen 500-barrel tanks, four gas production units, two gas compression skid, four vapor recovery towers, horizontal vent scrubber, and one combustor. QES was on location with a nitrogen truck injecting nitrogen into the 4H well for Enhanced Recovery.
| 12125-02-9
 
|
 
 
|-
 
|-
 +
| 0175625523
 +
| 2014-09-07
 +
| Preliminary Restoration
 +
| No Violations
 +
| On the day of my inspection I witnessed that the site passed preliminary restoration according to ORC 1509.072A.
 
|-
 
|-
| 0.000924933
+
| 0207100833
| Cured acrylic resin
+
| 2018-10-29
| 0.0
+
| Production Wells
|  
+
| No Violations
| Other Ingredient(s)
+
| During my inspection Cameron was on location in the process of installing valve removal plugs and back pressure valves on the 1H, 2H, and 3H.
| Confidential
 
|
 
 
|-
 
|-
 +
| 0226322298
 +
| 2014-06-23
 +
| Drill / Deepen /  Reopen
 +
| No Violations
 +
| On the day of my inspection, I witnessed Universal break circulation with fresh water then mix and displace five hundred forty two barrel of Type-1 cement to a depth of 315 foot, I witnessed 20 barrels of cement returns to surface with a weight of 15.6 and a yield of 1.20. My site inspection revealed no erosion and good vegetation, no spills to report and all fluid storage is setting inside containment.
 
|-
 
|-
| 0.00149528
+
| 0230212310
| Hydrochloric acid
+
| 2015-07-16
| 30.0
+
| Production Wells
| HYDROCHLORIC ACID 10-30%
+
| No Violations
| Solvent
+
| On the day of my inspection I witnessed that the well is online and equipped with a plunger lift system with valves in the open position. Gauges present read 1100psi on the tubing and 1500psi on the casing. Production equipment included a sand trap, a GP Unit, a vapor recovery system and a total of 12-500bbl tanks all within containment and shared with the 1H, 3H and 4H.
| 7647-01-0
 
| Halliburton
 
 
|-
 
|-
 +
| 0336188179
 +
| 2018-10-22
 +
| Production Wells
 +
| No Violations
 +
| The well had been decommissioned with tubing plugs while 2 new wells are being drilled on the pad.
 
|-
 
|-
| 2.52085e-06
+
| 0378609914
| Food red 10
+
| 2018-08-29
| 0.0
+
| Production Wells
|  
+
| No Violations
| Other Ingredient(s)
+
| The purpose of my inspection was a status check. The well was equipped with a production tree style wellhead with a plunger lift system. Production valves were in the open position. The cellar had been filled with pea gravel. Gauges were present for all casing strings, but the annulus gauges were not identified.  The production equipment consisted of fifteen 500-barrel tanks, four gas production units, two gas compression skid, four vapor recovery towers, horizontal vent scrubber, and one combustor. Identification was present and production records were current. Utica Operating Resources has been notified to identify the gauges for annular pressure monitoring.
| 3734-67-6
 
|
 
 
|-
 
|-
 +
| 0433231876
 +
| 2017-06-29
 +
| Production Wells
 +
| No Violations
 +
| On the day of my inspection I witnessed that the well was equipped with a plunger lift system with valves in the open position. Gauges present read 325 pounds per square inch on the tubing and 505 pounds per square inch on the casing. Production equipment included a sand trap, a GP Unit, a vapor recovery system and a total of 12-500 barrel tanks all within containment and shared with the 1H, 3H and 4H.
 
|-
 
|-
| 0.0115683
+
| 0480989814
| Polyacrylamide copolymer
+
| 2018-09-25
| 0.0
+
| Production Wells
|  
+
| No Violations
| Other Ingredient(s)
+
| The purpose of my inspection was to document the status of Utica Resource Operatings Dynamite Pad prior to SIMOPS activities.  Guerney County Inspector Austin Gutridge was present during the inspection.  At the time of inspection well #2-4337 remained in production.  Correct identification was present.  A total of four (4) production wells were on the pad.  Well #2-4337 will be within the fall radius of the anticipated rig contracted to drill the two permitted wells on the West side of the pad.  Approved temporary abandonment permit conditions will need to be completed on well #2-4337 prior to the commencement of drilling activities that include well #2-4337 within the fall radius of the derrick.
| Confidential
 
|
 
 
|-
 
|-
 +
| 0501190999
 +
| 2018-10-09
 +
| Production Wells
 +
| No Violations
 +
| During my inspection the pad was being prepared for the rig to arrive to drill the surface boreholes for 3405924532 and 3405924533. During my inspection the well was caged and still appeared to be in production. Rig components were being brought on location.
 
|-
 
|-
| 0.000704475
+
| 0530952458
| Silica gel
+
| 2019-01-11
| 0.0
+
| Production Wells
|  
+
| No Violations
| Other Ingredient(s)
+
| The inspection was conducted as a simultaneous operation inspection on a production well. The well is equipped with a large Texas Style gas plunger lift system with a steel cage built over the well. The production master valves are open, and the annular valves are open measuring pressure. The tubing pressure is 0 psi and the annulus are reading 0 psi.
| 112926-00-8
 
|
 
 
|-
 
|-
 +
| 0675723424
 +
| 2018-09-27
 +
| Production Wells
 +
| No Violations
 +
| Accompanied by ODNR Southeast Regional Supervisor Brent Bear, during our inspection rig mats were being place on the pad. The well was equipped with a plunger lift system with production valves in the open position. Annular pressure monitoring was present. The production equipment consisted of fifteen 500-barrel tanks, four gas production units, two gas compression skids, four vapor recovery towers, horizontal vent scrubber, and one combustor. Kevin Rothenbuhler contacted me and stated that the pea gravel was removed from the cellar, the valves for annular pressure monitoring were tightened, and while utilizing a gas sniffer no leaks were detected. The pea gravel was placed back in the cellars today and no bubbling was present.
 
|-
 
|-
| 0.0
+
| 0718330116
| Fatty acids
+
| 2018-09-25
| 0.0
+
| Production Wells
|  
+
| No Violations
| Other Ingredient(s)
+
| Accompanied by ODNR Kenn Frye, during our inspection a berm was being constructed around the pad with the cuttings from the conductors. Conductors had been cemented for 3405924532 and 3405924533. The well was equipped with a plunger lift system with production valves in the open position. Annular pressure monitoring was present. The production equipment consisted of fifteen 500-barrel tanks, four gas production units, two gas compression skids, four vapor recovery towers, horizontal vent scrubber, and one combustor. Kevin Rothenbuhler was contacted about the cellars bubbling on the 3H and 4H. Mr. Rothenbuhler stated that they would remove the pea gravel from the cellars on all wells and tighten valves and fittings that are plumbed up for annular pressure monitoring to remediate the bubbling.
|  tall oil
 
|
 
 
|-
 
|-
 +
| 0973841038
 +
| 2018-04-26
 +
| Production Wells
 +
| No Violations
 +
| The purpose of my inspection was a status check. During my inspection the well was equipped with a plunger lift system with production valves in the open position. Annular pressure monitoring was present. The production equipment consisted of fifteen 500 barrel tanks, four gas production units, two gas compression skid, four vapor recovery towers, horizontal vent scrubber, and one combustor. Identification was present and production records were current.
 
|-
 
|-
| 0.00220449
+
| 0985021196
| Tributyl tetradecyl phosphonium chloride
+
| 2019-04-15
| 10.0
+
| Production Wells
| BE-9W
+
| No Violations
| Biocide
+
| The purpose of my inspection was a status check. During my inspection the well was equipped with a plunger lift system with production valves in the open position. Annular pressure monitoring was present. The production equipment consisted of sixteen 500-barrel tanks, four gas production units, two gas compression skids, four vapor recovery towers, horizontal vent scrubber, and two combustors. The well was caged while the 2 wells that were recently added to the pad endure drill-out operations.
| 81741-28-8
 
| Halliburton
 
 
|-
 
|-
 +
| 1043645262
 +
| 2018-11-05
 +
| Production Wells
 +
| No Violations
 +
| During my inspection there was not a drilling rig on location. The well was temporarily abandoned and caged.
 
|-
 
|-
| 5.45938e-05
+
| 1055609994
| Propargyl alcohol
+
| 2018-11-08
| 10.0
+
| Production Wells
| HAI-OS ACID INHIBITOR
+
| No Violations
| Corrosion Inhibitor
+
| The purpose of my inspection was to conduct a status check on well #2-4337.  At the time of my inspection the well was temporarily abandoned and caged while Patterson #343 was rigging up to drill two additional wells on the pad.  Jersey barriers were placed outside of the cage to prevent a collision with the well head.  Pressure gauges to monitor annular, production, and tubing pressure remained in place.  The intermediate casing annular pressure gauge indicated 60 psi.  The production casing annulus indicated 0 psi.  The casing pressure gauge indicated 900 psi.  The tubing gauges indicated 200 psi.  All valves remained in the closed position.  No leaks were observed.  The flare stack was positioned in the Southwest corner of the pad and away from the well head and surface equipment.  While I was on location I met with company representative Dave Gray to discuss the condition of the well.  I will contact Utica Resources VP of Operations Kevin Rothenbuhler to investigate the situation and make DOGRM Inspector Patrick Shreve aware of the situation for monitoring.
| 107-19-7
 
| Halliburton
 
 
|-
 
|-
 +
| 1212700983
 +
| 2014-03-25
 +
| Casing String Witnessed
 +
| No Violations
 +
| On the day of my inspection I witnessed that Express Energy Services had drilled a 36 inch diameter hole to the depth of 115 feet and set 115 feet of 30 inch conductor pipe. Express Energy could not get conductor pipe plum. They are pulling pipe back out and will ream hole to 42 inches in diameter and rerun pipe and cement tomorrow.
 
|-
 
|-
| 0.000327563
+
| 1425870260
| Methanol
+
| 2017-10-24
| 60.0
+
| Production Wells
| HAI-OS ACID INHIBITOR
+
| No Violations
| Corrosion Inhibitor
+
| On the day of my inspection I witnessed that the well was equipped with a plunger lift system with valves in the open position. Gauges present read 375 pounds per square inch on the tubing and 555 pounds per square inch on the casing. Production equipment included a sand trap, a GP Unit, a vapor recovery system and a total of 12-500 barrel tanks all within containment and shared with the 1H, 3H and 4H.
| 67-56-1
 
| Halliburton
 
 
|-
 
|-
 +
| 1476978276
 +
| 2016-10-20
 +
| Production Wells
 +
| No Violations
 +
| At 0830, I received a call from PDC EHS Supervisor Tony Long who stated that Senecaville Fire Department was dispatched to the location last night as flames were coming out of the combustor. Upon arrival I met with PDC Production Superintendent Kevin Rothenbuhler who stated that the incident occurred this morning approximately at 0700 with the wells being shut-in remotely. Mr. Rothenbuhler stated that when he arrived it was determined that the dump valve for the tower of the 2H malfunctioned resulting in the float sticking. The tower then filled with oil, overflowing into the vapor recovery line, filling up the slug catcher and making its way to the combustor where it was ignited. The vapor recovery towers had been converted to separators approximately 2months ago resulting in reducing the working pressure of the vessel from 260 pounds per square inch to 30 pounds per square inch. There were no visible signs of the fire or the product reaching the well pad. Well technicians were on site making repairs to the dump valve and ECM was pulling fluids from the system. Upon repairs to the valve the wells will be brought back online.
 
|-
 
|-
| 0.0270769
+
| 1586268907
| Ethylene glycol
+
| 2016-12-20
| 30.0
+
| Production Wells
| BC-140
+
| No Violations
| Crosslinker
+
| On the day of my inspection I witnessed that the well was equipped with a plunger lift system with valves in the open position. Gauges present read 375 pounds per square inch on the tubing and 770 pounds per square inch on the casing. Production equipment included a sand trap, a GP Unit, a vapor recovery system and a total of 12-500 barrel tanks all within containment and shared with the 1H, 3H and 4H.
| 107-21-1
 
| Halliburton
 
 
|-
 
|-
 +
| 1713767486
 +
| 2019-02-06
 +
| Production Wells
 +
| No Violations
 +
| The purpose of my inspection was a status check. The well was recently turned back on after being temporarily abandon in order for two addition wells to be drilled on pad. During my inspection the well was equipped with a plunger lift system with production valves in the open position. Annular pressure monitoring was present. The production equipment consisted of sixteen 500-barrel tanks, four gas production units, two gas compression skids, four vapor recovery towers, horizontal vent scrubber, and two combustors.
 
|-
 
|-
| 0.0541539
+
| 1770352598
| Monoethanolamine borate
+
| 2018-10-11
| 60.0
+
| Production Wells
| BC-140
+
| No Violations
| Crosslinker
+
| During my inspection Fountain Quail Rig 4 was on location preparing to drill two additional wells on pad. The well was still producing during inspection. I spoke with Dave Grey, the company man on location for Utica Resources and Mr. Grey stated that they plan to produce the well until the super triple rig comes on location to drill the curves and laterals on the other two wells 7H and 8H.
| 26038-87-9
 
| Halliburton
 
 
|-
 
|-
 
|}
 
|}
For data sources see<ref>{{cite web | title = FracFocus Chemical Disclosure Registry |publisher = [http://www.fracfocusdata.org/DisclosureSearch/]| date = 2015-08-10 | url = http://wellwiki.org/wiki/Well_Chemicals_Data_Sources | accessdate = 2015-08-10 }}</ref>
+
<!--==== Violations Commited ====
== References ==
+
{| class="wikitable sortable" width="95%"
{{reflist}}
+
!scope="col" style="text-align: center"| Inspection ID
 +
!scope="col" style="text-align: center"| Violation ID
 +
!scope="col" style="text-align: center"| Violation Date
 +
!scope="col" style="text-align: center"| Violation Code
 +
!scope="col" style="text-align: center"| Violation Comments
 +
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date = 2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
==References==
 +
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Ohio Wells]]
 +
[[Category:FracFocus]]

Revision as of 20:23, 30 July 2019

Well Details

Well ID: 34-059-24337
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Richland Township
Operator Name: UTICA RESOURCE OPERATING LLC
Well Pad ID: US-OH-000877
Farm/Lease Name: DYNAMITE
License Status: Producing
License Date: 2014-02-24
Spud Date: 2014-03-22
Spud Drilling Contractor: H&P DRILLING
Final Drill Date: 2014-09-05
Well Total Depth: 13780 ft
Configuration: Horizontal
Latitude: 39.978216129
Longitude: -81.42040948

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2014-02-24 Proposed Formations:POINT PLEASANT, Issued Date:2/24/2014, Expired Date:2/24/2016 12:00:00 PM, Drilling unit acres:560.836, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2014-09-05
Completion Report Received 2015-07-23
Construction Permit Expires 2016-02-24
Correction to Well 2016-10-21 CHANGE IN TARGET/TAKEPOINT/ACREAGE PER AS DRILLED PLAT RCVD 10/19/16-ALE
Change of Owner 2018-05-04 Operator changed from 8595, PDC ENERGY INC to 10114, UTICA RESOURCE OPERATING LLC
Record Last Modified 2018-05-04

For data sources see[2]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 10/19/2014 11/12/2014 7205 9,398,160.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 SP BREAKER Halliburton Breaker Sodium persulfate 7775-27-1 100 0.00159865 1433
FR-66 Halliburton Friction Reducer Hydrotreated light petroleum distillate 64742-47-8 30 0.0115683 10364
WG-36 GELLING AGENT Halliburton Gelling Agent Guar gum 9000-30-0 100 0.0704475 63108
BC-140 Halliburton Crosslinker Ethylene glycol 107-21-1 30 0.0270769 24256
Monoethanolamine borate 26038-87-9 60 0.0541539 48512
OPTIFLO-HTE Halliburton Breaker Walnut hulls NA 100 0.00308311 2762
Crystalline silica, quartz 14808-60-7 30 0.000924933 829
Other Ingredient(s) Olefins Confidential 0 0.00000546 5
2,7-Naphthalenedisulfonic acid, 5-(acetylamino) -4-hydroxy-3-[(2-methoxyphenyl) azo] -, disodium salt 6625-46-3 0 0.00000252 3
Silica gel 112926-00-8 0 0.000704475 632
Sorbitan, mono-9-octadecenoate, (Z) 1338-43-8 0 0.000385609 346
Alcohols, C12-16, ethoxylated 68551-12-2 0 0.00192805 1728
Fatty acids, tall oil Confidential 0 0.000163781 147
Crystalline Silica, Quartz 14808-60-7 0 0.00007045 64
Surfactant mixture Confidential 0 0.000704475 632
Food red 10 3734-67-6 0 0.00000252 3
Alcohols, C14-C15, ethoxylated 68951-67-7 0 0.000163781 147
Reaction product of acetophenone, formaldehyde, thiourea and oleic acid in dimethyl formamide 68527-49-1 0 0.000163781 147
Propylene glycol 57-55-6 0 0.013227 11849
Cured acrylic resin Confidential 0 0.000924933 829
Bentonite, benzyl(hydrogenated tallow alkyl) dimethylammonium stearate complex 121888-68-4 0 0.00352237 3156
Fatty acid tall oil amide Confidential 0 0.00192805 1728
C.I. Pigment Red 5 6410-41-9 0 0.00003083 28
Olefins Confidential 0 0.00002730 25
Enzyme Confidential 0 0.000154155 139
Polyacrylamide copolymer Confidential 0 0.0115683 10364
Sorbitan monooleate polyoxyethylene derivative 9005-65-6 0 0.000385609 346
Ammonium chloride 12125-02-9 0 0.00192805 1728
Sodium chloride 7647-14-5 0 0.00192805 1728
Cured acrylic resin Confidential 0 0.00003083 28
2,7-Naphthalenedisulfonic acid, 3-hydroxy-4-[(4-sulfor-1-naphthalenyl) azo] -, trisodium salt 915-67-3 0 0.00000252 3
Water 7732-18-5 0 0.783397 701780
Sodium sulfate 7757-82-6 0 0.00126202 1131
100 Mesh - COMMON WHITE Halliburton Proppant Crystalline silica, quartz 14808-60-7 100 1.02559 918741
HYDROCHLORIC ACID 5-10% Halliburton Solvent Hydrochloric acid 7647-01-0 10 0.0634894 56875
Fresh Water Operator Base Fluid Fresh Water 7732-18-5 100 87.3911 78,286,400.0
SCALECHEK LP-55 SCALE INHIBITOR Halliburton Scale Inhibitor Polyacrylate Confidential 60 0.0151251 13550
HYDROCHLORIC ACID 10-30% Halliburton Solvent Hydrochloric acid 7647-01-0 30 0.00149528 1340
BE-9W Halliburton Biocide Tributyl tetradecyl phosphonium chloride 81741-28-8 10 0.00220449 1975
30/50 - PREMIUM WHITE Halliburton Proppant Crystalline silica, quartz 14808-60-7 100 10.6727 9,560,790.0
HAI-OS ACID INHIBITOR Halliburton Corrosion Inhibitor Propargyl alcohol 107-19-7 10 0.00005459 49
Methanol 67-56-1 60 0.000327563 294
BE-9 Halliburton Biocide Tributyl tetradecyl phosphonium chloride 81741-28-8 10 0.00189753 1700

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2014 PDC ENERGY INC 16518 4513 13
2015 PDC ENERGY INC 324317 77269 363
2016 PDC ENERGY INC 175151 30592 366
2017 PDC ENERGY INC 125198 18106 365
2018 UTICA RESOURCE OPERATING LLC 88211 7444 288
2019 UTICA RESOURCE OPERATING LLC 25575 2414 68

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 PDC ENERGY INC Brine 3711 13
2015 PDC ENERGY INC Brine 27569 363
2016 PDC ENERGY INC Brine 7170 366
2017 PDC ENERGY INC Brine 4230 365
2018 UTICA RESOURCE OPERATING LLC Brine 1772 197
2019 UTICA RESOURCE OPERATING LLC Brine 204 68

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0058954358 2018-08-16 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a plunger lift system with production valves in the open position. Gauges were present on all casing strings. The production equipment consisted of fifteen 500-barrel tanks, four gas production units, two gas compression skid, four vapor recovery towers, horizontal vent scrubber, and one combustor. QES was on location with a nitrogen truck injecting nitrogen into the 4H well for Enhanced Recovery.
0175625523 2014-09-07 Preliminary Restoration No Violations On the day of my inspection I witnessed that the site passed preliminary restoration according to ORC 1509.072A.
0207100833 2018-10-29 Production Wells No Violations During my inspection Cameron was on location in the process of installing valve removal plugs and back pressure valves on the 1H, 2H, and 3H.
0226322298 2014-06-23 Drill / Deepen / Reopen No Violations On the day of my inspection, I witnessed Universal break circulation with fresh water then mix and displace five hundred forty two barrel of Type-1 cement to a depth of 315 foot, I witnessed 20 barrels of cement returns to surface with a weight of 15.6 and a yield of 1.20. My site inspection revealed no erosion and good vegetation, no spills to report and all fluid storage is setting inside containment.
0230212310 2015-07-16 Production Wells No Violations On the day of my inspection I witnessed that the well is online and equipped with a plunger lift system with valves in the open position. Gauges present read 1100psi on the tubing and 1500psi on the casing. Production equipment included a sand trap, a GP Unit, a vapor recovery system and a total of 12-500bbl tanks all within containment and shared with the 1H, 3H and 4H.
0336188179 2018-10-22 Production Wells No Violations The well had been decommissioned with tubing plugs while 2 new wells are being drilled on the pad.
0378609914 2018-08-29 Production Wells No Violations The purpose of my inspection was a status check. The well was equipped with a production tree style wellhead with a plunger lift system. Production valves were in the open position. The cellar had been filled with pea gravel. Gauges were present for all casing strings, but the annulus gauges were not identified. The production equipment consisted of fifteen 500-barrel tanks, four gas production units, two gas compression skid, four vapor recovery towers, horizontal vent scrubber, and one combustor. Identification was present and production records were current. Utica Operating Resources has been notified to identify the gauges for annular pressure monitoring.
0433231876 2017-06-29 Production Wells No Violations On the day of my inspection I witnessed that the well was equipped with a plunger lift system with valves in the open position. Gauges present read 325 pounds per square inch on the tubing and 505 pounds per square inch on the casing. Production equipment included a sand trap, a GP Unit, a vapor recovery system and a total of 12-500 barrel tanks all within containment and shared with the 1H, 3H and 4H.
0480989814 2018-09-25 Production Wells No Violations The purpose of my inspection was to document the status of Utica Resource Operatings Dynamite Pad prior to SIMOPS activities. Guerney County Inspector Austin Gutridge was present during the inspection. At the time of inspection well #2-4337 remained in production. Correct identification was present. A total of four (4) production wells were on the pad. Well #2-4337 will be within the fall radius of the anticipated rig contracted to drill the two permitted wells on the West side of the pad. Approved temporary abandonment permit conditions will need to be completed on well #2-4337 prior to the commencement of drilling activities that include well #2-4337 within the fall radius of the derrick.
0501190999 2018-10-09 Production Wells No Violations During my inspection the pad was being prepared for the rig to arrive to drill the surface boreholes for 3405924532 and 3405924533. During my inspection the well was caged and still appeared to be in production. Rig components were being brought on location.
0530952458 2019-01-11 Production Wells No Violations The inspection was conducted as a simultaneous operation inspection on a production well. The well is equipped with a large Texas Style gas plunger lift system with a steel cage built over the well. The production master valves are open, and the annular valves are open measuring pressure. The tubing pressure is 0 psi and the annulus are reading 0 psi.
0675723424 2018-09-27 Production Wells No Violations Accompanied by ODNR Southeast Regional Supervisor Brent Bear, during our inspection rig mats were being place on the pad. The well was equipped with a plunger lift system with production valves in the open position. Annular pressure monitoring was present. The production equipment consisted of fifteen 500-barrel tanks, four gas production units, two gas compression skids, four vapor recovery towers, horizontal vent scrubber, and one combustor. Kevin Rothenbuhler contacted me and stated that the pea gravel was removed from the cellar, the valves for annular pressure monitoring were tightened, and while utilizing a gas sniffer no leaks were detected. The pea gravel was placed back in the cellars today and no bubbling was present.
0718330116 2018-09-25 Production Wells No Violations Accompanied by ODNR Kenn Frye, during our inspection a berm was being constructed around the pad with the cuttings from the conductors. Conductors had been cemented for 3405924532 and 3405924533. The well was equipped with a plunger lift system with production valves in the open position. Annular pressure monitoring was present. The production equipment consisted of fifteen 500-barrel tanks, four gas production units, two gas compression skids, four vapor recovery towers, horizontal vent scrubber, and one combustor. Kevin Rothenbuhler was contacted about the cellars bubbling on the 3H and 4H. Mr. Rothenbuhler stated that they would remove the pea gravel from the cellars on all wells and tighten valves and fittings that are plumbed up for annular pressure monitoring to remediate the bubbling.
0973841038 2018-04-26 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a plunger lift system with production valves in the open position. Annular pressure monitoring was present. The production equipment consisted of fifteen 500 barrel tanks, four gas production units, two gas compression skid, four vapor recovery towers, horizontal vent scrubber, and one combustor. Identification was present and production records were current.
0985021196 2019-04-15 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a plunger lift system with production valves in the open position. Annular pressure monitoring was present. The production equipment consisted of sixteen 500-barrel tanks, four gas production units, two gas compression skids, four vapor recovery towers, horizontal vent scrubber, and two combustors. The well was caged while the 2 wells that were recently added to the pad endure drill-out operations.
1043645262 2018-11-05 Production Wells No Violations During my inspection there was not a drilling rig on location. The well was temporarily abandoned and caged.
1055609994 2018-11-08 Production Wells No Violations The purpose of my inspection was to conduct a status check on well #2-4337. At the time of my inspection the well was temporarily abandoned and caged while Patterson #343 was rigging up to drill two additional wells on the pad. Jersey barriers were placed outside of the cage to prevent a collision with the well head. Pressure gauges to monitor annular, production, and tubing pressure remained in place. The intermediate casing annular pressure gauge indicated 60 psi. The production casing annulus indicated 0 psi. The casing pressure gauge indicated 900 psi. The tubing gauges indicated 200 psi. All valves remained in the closed position. No leaks were observed. The flare stack was positioned in the Southwest corner of the pad and away from the well head and surface equipment. While I was on location I met with company representative Dave Gray to discuss the condition of the well. I will contact Utica Resources VP of Operations Kevin Rothenbuhler to investigate the situation and make DOGRM Inspector Patrick Shreve aware of the situation for monitoring.
1212700983 2014-03-25 Casing String Witnessed No Violations On the day of my inspection I witnessed that Express Energy Services had drilled a 36 inch diameter hole to the depth of 115 feet and set 115 feet of 30 inch conductor pipe. Express Energy could not get conductor pipe plum. They are pulling pipe back out and will ream hole to 42 inches in diameter and rerun pipe and cement tomorrow.
1425870260 2017-10-24 Production Wells No Violations On the day of my inspection I witnessed that the well was equipped with a plunger lift system with valves in the open position. Gauges present read 375 pounds per square inch on the tubing and 555 pounds per square inch on the casing. Production equipment included a sand trap, a GP Unit, a vapor recovery system and a total of 12-500 barrel tanks all within containment and shared with the 1H, 3H and 4H.
1476978276 2016-10-20 Production Wells No Violations At 0830, I received a call from PDC EHS Supervisor Tony Long who stated that Senecaville Fire Department was dispatched to the location last night as flames were coming out of the combustor. Upon arrival I met with PDC Production Superintendent Kevin Rothenbuhler who stated that the incident occurred this morning approximately at 0700 with the wells being shut-in remotely. Mr. Rothenbuhler stated that when he arrived it was determined that the dump valve for the tower of the 2H malfunctioned resulting in the float sticking. The tower then filled with oil, overflowing into the vapor recovery line, filling up the slug catcher and making its way to the combustor where it was ignited. The vapor recovery towers had been converted to separators approximately 2months ago resulting in reducing the working pressure of the vessel from 260 pounds per square inch to 30 pounds per square inch. There were no visible signs of the fire or the product reaching the well pad. Well technicians were on site making repairs to the dump valve and ECM was pulling fluids from the system. Upon repairs to the valve the wells will be brought back online.
1586268907 2016-12-20 Production Wells No Violations On the day of my inspection I witnessed that the well was equipped with a plunger lift system with valves in the open position. Gauges present read 375 pounds per square inch on the tubing and 770 pounds per square inch on the casing. Production equipment included a sand trap, a GP Unit, a vapor recovery system and a total of 12-500 barrel tanks all within containment and shared with the 1H, 3H and 4H.
1713767486 2019-02-06 Production Wells No Violations The purpose of my inspection was a status check. The well was recently turned back on after being temporarily abandon in order for two addition wells to be drilled on pad. During my inspection the well was equipped with a plunger lift system with production valves in the open position. Annular pressure monitoring was present. The production equipment consisted of sixteen 500-barrel tanks, four gas production units, two gas compression skids, four vapor recovery towers, horizontal vent scrubber, and two combustors.
1770352598 2018-10-11 Production Wells No Violations During my inspection Fountain Quail Rig 4 was on location preparing to drill two additional wells on pad. The well was still producing during inspection. I spoke with Dave Grey, the company man on location for Utica Resources and Mr. Grey stated that they plan to produce the well until the super triple rig comes on location to drill the curves and laterals on the other two wells 7H and 8H.

For data sources see[8]

References