X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-105-21682"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-105-21682
 
| Well ID: 37-105-21682
| style="height=100%; align=center" rowspan="14" | {{#display_map: 41.846792, -78.156531 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.846792, -78.156531 | width=100% | height=100% }}
 
|-
 
|-
 
| Country: United States
 
| Country: United States
Line 21: Line 21:
 
| License Status: Active
 
| License Status: Active
 
|-
 
|-
| Spud Date: 07/12/2010
+
| Spud Date: 2010-07-12
 
|-
 
|-
| Permit Date: 6/2/2010
+
| Permit Date: 2010-06-02
 
|-
 
|-
 
| Unconventional Well: Y
 
| Unconventional Well: Y
Line 49: Line 49:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 2010-12-02
 +
| 2010-12-02
 +
| style="text-align: right;" | 5800.0
 +
| style="text-align: right;" | 6134378.0
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="19"| 1
 +
| rowspan="1"| AI -2
 +
| rowspan="1"| Superior Well Services
 +
| rowspan="1"| Acid Inhibitor
 +
| Glycol Ether
 +
| 111-76-2
 +
| style="text-align: right;" | 30.0
 +
| style="text-align: right;" | 0.00008000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Super TSC
 +
| rowspan="1"| Superior Well Services
 +
| rowspan="1"| Scale Inhibitor
 +
| Propylene glycol
 +
| 57-55-6
 +
| style="text-align: right;" | 50.0
 +
| style="text-align: right;" | 0.00515
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="12"|
 +
| rowspan="12"|
 +
| rowspan="12"|
 +
| Diethylene Glycol
 +
| 111-46-6
 +
| style="text-align: right;" | 3.5
 +
| style="text-align: right;" | 0.00031
 +
| style="text-align: right;" |
 +
|-
 +
| Proprietary Component
 +
| Proprietary
 +
| style="text-align: right;" | 7.0
 +
| style="text-align: right;" | 0.00002000
 +
| style="text-align: right;" |
 +
|-
 +
| Ethylene Glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 1.0
 +
| style="text-align: right;" | 0.00891
 +
| style="text-align: right;" |
 +
|-
 +
| Polyethylene Glycol
 +
| 25322-68-3
 +
| style="text-align: right;" | 50.0
 +
| style="text-align: right;" | 0.00446
 +
| style="text-align: right;" |
 +
|-
 +
| Anionic copolymer
 +
| Proprietary
 +
| style="text-align: right;" | 10.0
 +
| style="text-align: right;" | 0.00103
 +
| style="text-align: right;" |
 +
|-
 +
| Propargyl Alcohol
 +
| 107-19-7
 +
| style="text-align: right;" | 30.0
 +
| style="text-align: right;" | 0.00008000
 +
| style="text-align: right;" |
 +
|-
 +
| Isopropyl Alcohol
 +
| 67-63-0
 +
| style="text-align: right;" | 30.0
 +
| style="text-align: right;" | 0.00008000
 +
| style="text-align: right;" |
 +
|-
 +
| Anionic polymer
 +
| Proprietary
 +
| style="text-align: right;" | 10.0
 +
| style="text-align: right;" | 0.00103
 +
| style="text-align: right;" |
 +
|-
 +
| Ethoxylated Alcohols
 +
| 68551-12-2
 +
| style="text-align: right;" | 4.0
 +
| style="text-align: right;" | 0.00299
 +
| style="text-align: right;" |
 +
|-
 +
| Mineral Spirits
 +
| 8052-41-3
 +
| style="text-align: right;" | 10.0
 +
| style="text-align: right;" | 0.00747
 +
| style="text-align: right;" |
 +
|-
 +
| 2-Phosphonobutane-1,2,4 tricarboxylic acid
 +
| 37971-36-1
 +
| style="text-align: right;" | 10.0
 +
| style="text-align: right;" | 0.00103
 +
| style="text-align: right;" |
 +
|-
 +
| Propylene Glycol
 +
| 57-55-6
 +
| style="text-align: right;" | 25.0
 +
| style="text-align: right;" | 0.01868
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| WFR-3B
 +
| rowspan="1"| Superior Well Services
 +
| rowspan="1"| Friction Reducer
 +
| Hydrotreated Light Distillate
 +
| 64742-47-8
 +
| style="text-align: right;" | 30.0
 +
| style="text-align: right;" | 0.02242
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| KR-153SL
 +
| rowspan="1"| Superior Well Services
 +
| rowspan="1"| Biocide
 +
| 2,2-Dibromo-3-nitrilo-propionamide
 +
| 10222-01-2
 +
| style="text-align: right;" | 20.0
 +
| style="text-align: right;" | 0.00178
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Sand
 +
| rowspan="1"| Superior Well Services
 +
| rowspan="1"| Proppant
 +
| Crystalline Silica (quartz)
 +
| 14808-60-7
 +
| style="text-align: right;" | 100.0
 +
| style="text-align: right;" | 13.26076
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Acid, Hydrochloric (3)
 +
| rowspan="1"| Superior Well Services
 +
| rowspan="1"| Solvent
 +
| Hydrochloric Acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 3.0
 +
| style="text-align: right;" | 0.03711
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Water*
 +
| rowspan="1"| PGE
 +
| rowspan="1"| Carrier/Base Fluid
 +
|
 +
| 7732-18-5
 +
| style="text-align: right;" | 100.0
 +
| style="text-align: right;" | 85.408
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 165: Line 348:
 
!scope="col" | Waste Facility ID
 
!scope="col" | Waste Facility ID
 
|-
 
|-
| 2010-2
+
| 2010-S02
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
 
| style="text-align: right;" | 807.21 Tons
 
| style="text-align: right;" | 807.21 Tons
Line 171: Line 354:
 
| 100361
 
| 100361
 
|-
 
|-
| 2010-2
+
| 2010-S02
 
| Drilling Fluid Waste (in Barrels)
 
| Drilling Fluid Waste (in Barrels)
 
| style="text-align: right;" | 67.00 Bbl
 
| style="text-align: right;" | 67.00 Bbl
Line 177: Line 360:
 
| PA0101508
 
| PA0101508
 
|-
 
|-
| 2010-2
+
| 2010-S02
 
| Drilling Fluid Waste (in Barrels)
 
| Drilling Fluid Waste (in Barrels)
 
| style="text-align: right;" | 6,642.00 Bbl
 
| style="text-align: right;" | 6,642.00 Bbl
Line 183: Line 366:
 
| PA0102784
 
| PA0102784
 
|-
 
|-
| 2010-2
+
| 2010-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 273.00 Bbl
 
| style="text-align: right;" | 273.00 Bbl
Line 189: Line 372:
 
| PA0101508
 
| PA0101508
 
|-
 
|-
| 2010-2
+
| 2010-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 251.00 Bbl
 
| style="text-align: right;" | 251.00 Bbl
Line 195: Line 378:
 
| PA0102784
 
| PA0102784
 
|-
 
|-
| 2011-1
+
| 2011-S01
 
| Drilling Fluid Waste (in Barrels)
 
| Drilling Fluid Waste (in Barrels)
 
| style="text-align: right;" | 1,734.29 Bbl
 
| style="text-align: right;" | 1,734.29 Bbl
Line 201: Line 384:
 
| PA0102784
 
| PA0102784
 
|-
 
|-
| 2011-1
+
| 2011-S01
 
| Fracing Fluid Waste (in Barrels)
 
| Fracing Fluid Waste (in Barrels)
 
| style="text-align: right;" | 1,918.89 Bbl
 
| style="text-align: right;" | 1,918.89 Bbl
Line 207: Line 390:
 
| PA0101508
 
| PA0101508
 
|-
 
|-
| 2011-1
+
| 2011-S01
 
| Fracing Fluid Waste (in Barrels)
 
| Fracing Fluid Waste (in Barrels)
 
| style="text-align: right;" | 112.70 Bbl
 
| style="text-align: right;" | 112.70 Bbl
Line 213: Line 396:
 
| PA0102784
 
| PA0102784
 
|-
 
|-
| 2011-1
+
| 2011-S01
 
| Fracturing Fluid Waste (in Tons)
 
| Fracturing Fluid Waste (in Tons)
 
| style="text-align: right;" | 27.43 Tons
 
| style="text-align: right;" | 27.43 Tons
Line 219: Line 402:
 
| 004835146
 
| 004835146
 
|-
 
|-
| 2011-1
+
| 2011-S01
 
| Fracturing Fluid Waste (in Tons)
 
| Fracturing Fluid Waste (in Tons)
 
| style="text-align: right;" | 9.11 Tons
 
| style="text-align: right;" | 9.11 Tons
Line 225: Line 408:
 
| 100361
 
| 100361
 
|-
 
|-
| 2011-1
+
| 2011-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 4,108.57 Bbl
 
| style="text-align: right;" | 4,108.57 Bbl
Line 231: Line 414:
 
| PA0102784
 
| PA0102784
 
|-
 
|-
| 2011-2
+
| 2011-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 539.81 Bbl
 
| style="text-align: right;" | 539.81 Bbl
Line 237: Line 420:
 
| 34-099-23127
 
| 34-099-23127
 
|-
 
|-
| 2011-2
+
| 2011-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 883.11 Bbl
 
| style="text-align: right;" | 883.11 Bbl
Line 243: Line 426:
 
| 34-007-24355
 
| 34-007-24355
 
|-
 
|-
| 2011-2
+
| 2011-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 595.77 Bbl
 
| style="text-align: right;" | 595.77 Bbl
Line 249: Line 432:
 
| 34-133-21076
 
| 34-133-21076
 
|-
 
|-
| 2011-2
+
| 2011-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 222.52 Bbl
 
| style="text-align: right;" | 222.52 Bbl
Line 255: Line 438:
 
| 34-133-24096
 
| 34-133-24096
 
|-
 
|-
| 2011-2
+
| 2011-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 13,098.93 Bbl
 
| style="text-align: right;" | 13,098.93 Bbl
Line 261: Line 444:
 
| UIC 45
 
| UIC 45
 
|-
 
|-
| 2012-1
+
| 2012-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 2,380.00 Bbl
 
| style="text-align: right;" | 2,380.00 Bbl
Line 267: Line 450:
 
| 525-1
 
| 525-1
 
|-
 
|-
| 2012-1
+
| 2012-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,245.00 Bbl
 
| style="text-align: right;" | 1,245.00 Bbl
Line 273: Line 456:
 
| 34-151-23420
 
| 34-151-23420
 
|-
 
|-
| 2012-1
+
| 2012-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 60.00 Bbl
 
| style="text-align: right;" | 60.00 Bbl
Line 279: Line 462:
 
| 34-155-21438
 
| 34-155-21438
 
|-
 
|-
| 2012-1
+
| 2012-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 30.00 Bbl
 
| style="text-align: right;" | 30.00 Bbl
Line 285: Line 468:
 
| 34-155-21447
 
| 34-155-21447
 
|-
 
|-
| 2012-1
+
| 2012-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,957.50 Bbl
 
| style="text-align: right;" | 1,957.50 Bbl
Line 291: Line 474:
 
| 34-155-21893
 
| 34-155-21893
 
|-
 
|-
| 2012-1
+
| 2012-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,620.50 Bbl
 
| style="text-align: right;" | 1,620.50 Bbl
Line 297: Line 480:
 
| 34-155-23795
 
| 34-155-23795
 
|-
 
|-
| 2012-1
+
| 2012-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,716.42 Bbl
 
| style="text-align: right;" | 1,716.42 Bbl
Line 303: Line 486:
 
|  
 
|  
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 566.00 Bbl
 
| style="text-align: right;" | 566.00 Bbl
Line 309: Line 492:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 60.00 Bbl
 
| style="text-align: right;" | 60.00 Bbl
Line 315: Line 498:
 
| 34-007-24355
 
| 34-007-24355
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,453.00 Bbl
 
| style="text-align: right;" | 1,453.00 Bbl
Line 321: Line 504:
 
| 34-133-20525
 
| 34-133-20525
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 242.00 Bbl
 
| style="text-align: right;" | 242.00 Bbl
Line 327: Line 510:
 
| 34-151-23420
 
| 34-151-23420
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 976.00 Bbl
 
| style="text-align: right;" | 976.00 Bbl
Line 333: Line 516:
 
| 34-155-21438
 
| 34-155-21438
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,040.00 Bbl
 
| style="text-align: right;" | 1,040.00 Bbl
Line 339: Line 522:
 
| 34-155-21447
 
| 34-155-21447
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,076.00 Bbl
 
| style="text-align: right;" | 1,076.00 Bbl
Line 345: Line 528:
 
| 34-155-21893
 
| 34-155-21893
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,076.00 Bbl
 
| style="text-align: right;" | 1,076.00 Bbl
Line 351: Line 534:
 
| 34-155-21894
 
| 34-155-21894
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,076.00 Bbl
 
| style="text-align: right;" | 1,076.00 Bbl
Line 357: Line 540:
 
| 34-155-23203
 
| 34-155-23203
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 2,748.00 Bbl
 
| style="text-align: right;" | 2,748.00 Bbl
Line 363: Line 546:
 
| 34-155-23795
 
| 34-155-23795
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 135.00 Bbl
 
| style="text-align: right;" | 135.00 Bbl
Line 369: Line 552:
 
|  
 
|  
 
|-
 
|-
| 2013-1
+
| 2013-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 431.67 Bbl
 
| style="text-align: right;" | 431.67 Bbl
Line 375: Line 558:
 
| 34-133-20525
 
| 34-133-20525
 
|-
 
|-
| 2013-1
+
| 2013-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 926.67 Bbl
 
| style="text-align: right;" | 926.67 Bbl
Line 381: Line 564:
 
| 34-151-23420
 
| 34-151-23420
 
|-
 
|-
| 2013-1
+
| 2013-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 60.00 Bbl
 
| style="text-align: right;" | 60.00 Bbl
Line 387: Line 570:
 
| 34-155-21438
 
| 34-155-21438
 
|-
 
|-
| 2013-1
+
| 2013-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 574.43 Bbl
 
| style="text-align: right;" | 574.43 Bbl
Line 393: Line 576:
 
| 34-155-21893
 
| 34-155-21893
 
|-
 
|-
| 2013-1
+
| 2013-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 574.45 Bbl
 
| style="text-align: right;" | 574.45 Bbl
Line 399: Line 582:
 
| 34-155-21894
 
| 34-155-21894
 
|-
 
|-
| 2013-1
+
| 2013-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 574.45 Bbl
 
| style="text-align: right;" | 574.45 Bbl
Line 405: Line 588:
 
| 34-155-23203
 
| 34-155-23203
 
|-
 
|-
| 2013-1
+
| 2013-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 60.00 Bbl
 
| style="text-align: right;" | 60.00 Bbl
Line 411: Line 594:
 
| 34-155-23732
 
| 34-155-23732
 
|-
 
|-
| 2013-1
+
| 2013-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,935.00 Bbl
 
| style="text-align: right;" | 1,935.00 Bbl
Line 417: Line 600:
 
| 34-155-23795
 
| 34-155-23795
 
|-
 
|-
| 2013-1
+
| 2013-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 20.00 Bbl
 
| style="text-align: right;" | 20.00 Bbl
Line 423: Line 606:
 
|  
 
|  
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 80.00 Bbl
 
| style="text-align: right;" | 80.00 Bbl
Line 429: Line 612:
 
| 34-007-24355
 
| 34-007-24355
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 778.33 Bbl
 
| style="text-align: right;" | 778.33 Bbl
Line 435: Line 618:
 
| 34-133-20525
 
| 34-133-20525
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 40.00 Bbl
 
| style="text-align: right;" | 40.00 Bbl
Line 441: Line 624:
 
| 34-151-21198
 
| 34-151-21198
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 439.90 Bbl
 
| style="text-align: right;" | 439.90 Bbl
Line 447: Line 630:
 
| 34-151-23420
 
| 34-151-23420
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 20.00 Bbl
 
| style="text-align: right;" | 20.00 Bbl
Line 453: Line 636:
 
| 34-155-21438
 
| 34-155-21438
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 239.40 Bbl
 
| style="text-align: right;" | 239.40 Bbl
Line 459: Line 642:
 
| 34-155-21893
 
| 34-155-21893
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 239.40 Bbl
 
| style="text-align: right;" | 239.40 Bbl
Line 465: Line 648:
 
| 34-155-21894
 
| 34-155-21894
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 58.33 Bbl
 
| style="text-align: right;" | 58.33 Bbl
Line 471: Line 654:
 
| 34-155-22403
 
| 34-155-22403
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 239.40 Bbl
 
| style="text-align: right;" | 239.40 Bbl
Line 477: Line 660:
 
| 34-155-23203
 
| 34-155-23203
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 723.33 Bbl
 
| style="text-align: right;" | 723.33 Bbl
Line 483: Line 666:
 
| 34-155-23795
 
| 34-155-23795
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,149.31 Bbl
 
| style="text-align: right;" | 1,149.31 Bbl
Line 489: Line 672:
 
|  
 
|  
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 280.00 Bbl
 
| style="text-align: right;" | 280.00 Bbl
Line 495: Line 678:
 
| 34-133-20525
 
| 34-133-20525
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 120.00 Bbl
 
| style="text-align: right;" | 120.00 Bbl
Line 501: Line 684:
 
| 34-151-23420
 
| 34-151-23420
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 196.67 Bbl
 
| style="text-align: right;" | 196.67 Bbl
Line 507: Line 690:
 
| 34-155-21438
 
| 34-155-21438
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 333.33 Bbl
 
| style="text-align: right;" | 333.33 Bbl
Line 513: Line 696:
 
| 34-155-21447
 
| 34-155-21447
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 152.79 Bbl
 
| style="text-align: right;" | 152.79 Bbl
Line 519: Line 702:
 
| 34-155-21893
 
| 34-155-21893
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 152.79 Bbl
 
| style="text-align: right;" | 152.79 Bbl
Line 525: Line 708:
 
| 34-155-21894
 
| 34-155-21894
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 20.00 Bbl
 
| style="text-align: right;" | 20.00 Bbl
Line 531: Line 714:
 
| 34-155-22403
 
| 34-155-22403
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 300.03 Bbl
 
| style="text-align: right;" | 300.03 Bbl
Line 537: Line 720:
 
| 34-155-23196
 
| 34-155-23196
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 152.79 Bbl
 
| style="text-align: right;" | 152.79 Bbl
Line 543: Line 726:
 
| 34-155-23203
 
| 34-155-23203
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 219.17 Bbl
 
| style="text-align: right;" | 219.17 Bbl
Line 549: Line 732:
 
| 34-155-23223
 
| 34-155-23223
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 653.41 Bbl
 
| style="text-align: right;" | 653.41 Bbl
Line 555: Line 738:
 
| 34-155-23732
 
| 34-155-23732
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 236.67 Bbl
 
| style="text-align: right;" | 236.67 Bbl
Line 561: Line 744:
 
| 34-155-23759
 
| 34-155-23759
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 275.83 Bbl
 
| style="text-align: right;" | 275.83 Bbl
Line 567: Line 750:
 
| 34-155-23795
 
| 34-155-23795
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 461.67 Bbl
 
| style="text-align: right;" | 461.67 Bbl
Line 573: Line 756:
 
|  
 
|  
 
|-
 
|-
| 2014-2
+
| 2014-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 2,020.98 Bbl
 
| style="text-align: right;" | 2,020.98 Bbl
Line 579: Line 762:
 
| 34-007-21847
 
| 34-007-21847
 
|-
 
|-
| 2014-2
+
| 2014-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 20.00 Bbl
 
| style="text-align: right;" | 20.00 Bbl
Line 585: Line 768:
 
| 34-155-21438
 
| 34-155-21438
 
|-
 
|-
| 2014-2
+
| 2014-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 40.00 Bbl
 
| style="text-align: right;" | 40.00 Bbl
Line 591: Line 774:
 
| 34-155-23196
 
| 34-155-23196
 
|-
 
|-
| 2014-2
+
| 2014-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 20.00 Bbl
 
| style="text-align: right;" | 20.00 Bbl
Line 597: Line 780:
 
| 34-155-23223
 
| 34-155-23223
 
|-
 
|-
| 2014-2
+
| 2014-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 20.00 Bbl
 
| style="text-align: right;" | 20.00 Bbl
Line 603: Line 786:
 
| 34-155-23732
 
| 34-155-23732
 
|-
 
|-
| 2014-2
+
| 2014-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 678.33 Bbl
 
| style="text-align: right;" | 678.33 Bbl
Line 609: Line 792:
 
|  
 
|  
 
|-
 
|-
| 2015-1
+
| 2015-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 351.00 Bbl
 
| style="text-align: right;" | 351.00 Bbl
Line 615: Line 798:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2015-1
+
| 2015-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,085.00 Bbl
 
| style="text-align: right;" | 1,085.00 Bbl
Line 621: Line 804:
 
| 34-007-21847
 
| 34-007-21847
 
|-
 
|-
| 2015-1
+
| 2015-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 6.67 Bbl
 
| style="text-align: right;" | 6.67 Bbl
Line 627: Line 810:
 
| 34-155-21893
 
| 34-155-21893
 
|-
 
|-
| 2015-1
+
| 2015-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 6.67 Bbl
 
| style="text-align: right;" | 6.67 Bbl
Line 633: Line 816:
 
| 34-155-21894
 
| 34-155-21894
 
|-
 
|-
| 2015-1
+
| 2015-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 6.67 Bbl
 
| style="text-align: right;" | 6.67 Bbl
Line 639: Line 822:
 
| 34-155-23203
 
| 34-155-23203
 
|-
 
|-
| 2015-1
+
| 2015-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 232.50 Bbl
 
| style="text-align: right;" | 232.50 Bbl
Line 645: Line 828:
 
| WMGR123NC010
 
| WMGR123NC010
 
|-
 
|-
| 2015-1
+
| 2015-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,103.17 Bbl
 
| style="text-align: right;" | 1,103.17 Bbl
Line 651: Line 834:
 
|  
 
|  
 
|-
 
|-
| 2015-2
+
| 2015-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 223.17 Bbl
 
| style="text-align: right;" | 223.17 Bbl
Line 657: Line 840:
 
| WMGR123NW005
 
| WMGR123NW005
 
|-
 
|-
| 2015-2
+
| 2015-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 954.33 Bbl
 
| style="text-align: right;" | 954.33 Bbl
Line 663: Line 846:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2015-2
+
| 2015-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 70.00 Bbl
 
| style="text-align: right;" | 70.00 Bbl
Line 669: Line 852:
 
| 34-007-21847
 
| 34-007-21847
 
|-
 
|-
| 2015-2
+
| 2015-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 119.83 Bbl
 
| style="text-align: right;" | 119.83 Bbl
Line 675: Line 858:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2015-2
+
| 2015-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 136.83 Bbl
 
| style="text-align: right;" | 136.83 Bbl
Line 681: Line 864:
 
| WMGR123NC010
 
| WMGR123NC010
 
|-
 
|-
| 2015-2
+
| 2015-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 574.83 Bbl
 
| style="text-align: right;" | 574.83 Bbl
Line 687: Line 870:
 
|  
 
|  
 
|-
 
|-
| 2016-1
+
| 2016-S01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 231.00 Bbl
 
| style="text-align: right;" | 231.00 Bbl
Line 693: Line 876:
 
| WMGR123NW005
 
| WMGR123NW005
 
|-
 
|-
| 2016-1
+
| 2016-S01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,640.67 Bbl
 
| style="text-align: right;" | 1,640.67 Bbl
Line 699: Line 882:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2016-1
+
| 2016-S01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 7.00 Bbl
 
| style="text-align: right;" | 7.00 Bbl
Line 705: Line 888:
 
| 34-007-2-3097
 
| 34-007-2-3097
 
|-
 
|-
| 2016-1
+
| 2016-S01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 7.00 Bbl
 
| style="text-align: right;" | 7.00 Bbl
Line 711: Line 894:
 
| 34-007-2-3177
 
| 34-007-2-3177
 
|-
 
|-
| 2016-1
+
| 2016-S01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 7.00 Bbl
 
| style="text-align: right;" | 7.00 Bbl
Line 717: Line 900:
 
| 34-007-2-3692
 
| 34-007-2-3692
 
|-
 
|-
| 2016-1
+
| 2016-S01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 70.00 Bbl
 
| style="text-align: right;" | 70.00 Bbl
Line 723: Line 906:
 
| 34-007-21847
 
| 34-007-21847
 
|-
 
|-
| 2016-1
+
| 2016-S01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 7.00 Bbl
 
| style="text-align: right;" | 7.00 Bbl
Line 729: Line 912:
 
| 34-007-23262
 
| 34-007-23262
 
|-
 
|-
| 2016-1
+
| 2016-S01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 7.00 Bbl
 
| style="text-align: right;" | 7.00 Bbl
Line 735: Line 918:
 
| 34-007-24355
 
| 34-007-24355
 
|-
 
|-
| 2016-2
+
| 2016-S02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 102.33 Bbl
 
| style="text-align: right;" | 102.33 Bbl
Line 741: Line 924:
 
| PA0102784
 
| PA0102784
 
|-
 
|-
| 2016-2
+
| 2016-S02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 35.00 Bbl
 
| style="text-align: right;" | 35.00 Bbl
Line 747: Line 930:
 
| WMGR123NW005
 
| WMGR123NW005
 
|-
 
|-
| 2016-2
+
| 2016-S02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,805.83 Bbl
 
| style="text-align: right;" | 1,805.83 Bbl
Line 753: Line 936:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2017-01
+
| 2017-M01
 
| Other Oil & Gas Wastes (in Barrels) RWC 899
 
| Other Oil & Gas Wastes (in Barrels) RWC 899
 
| style="text-align: right;" | 56.67 Bbl
 
| style="text-align: right;" | 56.67 Bbl
Line 759: Line 942:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2017-01
+
| 2017-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 35.00 Bbl
 
| style="text-align: right;" | 35.00 Bbl
Line 765: Line 948:
 
| WMGR123NW005
 
| WMGR123NW005
 
|-
 
|-
| 2017-01
+
| 2017-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 247.33 Bbl
 
| style="text-align: right;" | 247.33 Bbl
Line 771: Line 954:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2017-02
+
| 2017-M02
 
| Other Oil & Gas Wastes (in Barrels) RWC 899
 
| Other Oil & Gas Wastes (in Barrels) RWC 899
 
| style="text-align: right;" | 30.00 Bbl
 
| style="text-align: right;" | 30.00 Bbl
Line 777: Line 960:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2017-02
+
| 2017-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 264.67 Bbl
 
| style="text-align: right;" | 264.67 Bbl
Line 783: Line 966:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2017-03
+
| 2017-M03
 
| Other Oil & Gas Wastes (in Barrels) RWC 899
 
| Other Oil & Gas Wastes (in Barrels) RWC 899
 
| style="text-align: right;" | 21.67 Bbl
 
| style="text-align: right;" | 21.67 Bbl
Line 789: Line 972:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2017-03
+
| 2017-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 280.17 Bbl
 
| style="text-align: right;" | 280.17 Bbl
Line 795: Line 978:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2017-05
+
| 2017-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 298.33 Bbl
 
| style="text-align: right;" | 298.33 Bbl
Line 801: Line 984:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2017-06
+
| 2017-M06
 
| Other Oil & Gas Wastes (in Barrels) RWC 899
 
| Other Oil & Gas Wastes (in Barrels) RWC 899
 
| style="text-align: right;" | 25.83 Bbl
 
| style="text-align: right;" | 25.83 Bbl
Line 807: Line 990:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2017-06
+
| 2017-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 54.17 Bbl
 
| style="text-align: right;" | 54.17 Bbl
Line 813: Line 996:
 
| WMGR123NW005
 
| WMGR123NW005
 
|-
 
|-
| 2017-06
+
| 2017-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 261.67 Bbl
 
| style="text-align: right;" | 261.67 Bbl
Line 819: Line 1,002:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2017-07
+
| 2017-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 353.67 Bbl
 
| style="text-align: right;" | 353.67 Bbl
Line 825: Line 1,008:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2017-08
+
| 2017-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 271.50 Bbl
 
| style="text-align: right;" | 271.50 Bbl
Line 831: Line 1,014:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2017-09
+
| 2017-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 18.33 Bbl
 
| style="text-align: right;" | 18.33 Bbl
Line 837: Line 1,020:
 
| WMGR123NC010
 
| WMGR123NC010
 
|-
 
|-
| 2017-09
+
| 2017-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 324.17 Bbl
 
| style="text-align: right;" | 324.17 Bbl
Line 843: Line 1,026:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2017-09
+
| 2017-M09
 
| Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811
 
| Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811
 
| style="text-align: right;" | 0.03 Tons
 
| style="text-align: right;" | 0.03 Tons
Line 849: Line 1,032:
 
| 101397
 
| 101397
 
|-
 
|-
| 2017-10
+
| 2017-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 256.67 Bbl
 
| style="text-align: right;" | 256.67 Bbl
Line 855: Line 1,038:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2017-11
+
| 2017-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 310.00 Bbl
 
| style="text-align: right;" | 310.00 Bbl
Line 861: Line 1,044:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2017-12
+
| 2017-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 287.50 Bbl
 
| style="text-align: right;" | 287.50 Bbl
Line 867: Line 1,050:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2018-01
+
| 2018-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 30.00 Bbl
 
| style="text-align: right;" | 30.00 Bbl
Line 873: Line 1,056:
 
| 34-007-21847
 
| 34-007-21847
 
|-
 
|-
| 2018-01
+
| 2018-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 35.83 Bbl
 
| style="text-align: right;" | 35.83 Bbl
Line 879: Line 1,062:
 
| WMGR123NC010
 
| WMGR123NC010
 
|-
 
|-
| 2018-01
+
| 2018-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 73.00 Bbl
 
| style="text-align: right;" | 73.00 Bbl
Line 885: Line 1,068:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2018-01
+
| 2018-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 93.33 Bbl
 
| style="text-align: right;" | 93.33 Bbl
Line 891: Line 1,074:
 
|  
 
|  
 
|-
 
|-
| 2018-02
+
| 2018-M02
 
| Other Oil & Gas Wastes (in Barrels) RWC 899
 
| Other Oil & Gas Wastes (in Barrels) RWC 899
 
| style="text-align: right;" | 45.00 Bbl
 
| style="text-align: right;" | 45.00 Bbl
Line 897: Line 1,080:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2018-02
+
| 2018-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 161.67 Bbl
 
| style="text-align: right;" | 161.67 Bbl
Line 903: Line 1,086:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2018-02
+
| 2018-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 73.33 Bbl
 
| style="text-align: right;" | 73.33 Bbl
Line 909: Line 1,092:
 
|  
 
|  
 
|-
 
|-
| 2018-03
+
| 2018-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 330.83 Bbl
 
| style="text-align: right;" | 330.83 Bbl
Line 915: Line 1,098:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2018-04
+
| 2018-M04
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 18.33 Bbl
 
| style="text-align: right;" | 18.33 Bbl
Line 921: Line 1,104:
 
| WMGR123NW005
 
| WMGR123NW005
 
|-
 
|-
| 2018-04
+
| 2018-M04
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 200.00 Bbl
 
| style="text-align: right;" | 200.00 Bbl
Line 927: Line 1,110:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2018-05
+
| 2018-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 300.00 Bbl
 
| style="text-align: right;" | 300.00 Bbl
Line 933: Line 1,116:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2018-06
+
| 2018-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 287.50 Bbl
 
| style="text-align: right;" | 287.50 Bbl
Line 939: Line 1,122:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2018-06
+
| 2018-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 18.33 Bbl
 
| style="text-align: right;" | 18.33 Bbl
Line 945: Line 1,128:
 
|  
 
|  
 
|-
 
|-
| 2018-07
+
| 2018-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 139.17 Bbl
 
| style="text-align: right;" | 139.17 Bbl
Line 951: Line 1,134:
 
| 34-007-21847
 
| 34-007-21847
 
|-
 
|-
| 2018-07
+
| 2018-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 94.17 Bbl
 
| style="text-align: right;" | 94.17 Bbl
Line 957: Line 1,140:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2018-07
+
| 2018-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 17.50 Bbl
 
| style="text-align: right;" | 17.50 Bbl
Line 963: Line 1,146:
 
|  
 
|  
 
|-
 
|-
| 2018-08
+
| 2018-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 124.17 Bbl
 
| style="text-align: right;" | 124.17 Bbl
Line 969: Line 1,152:
 
| 34-007-21847
 
| 34-007-21847
 
|-
 
|-
| 2018-08
+
| 2018-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 195.00 Bbl
 
| style="text-align: right;" | 195.00 Bbl
Line 975: Line 1,158:
 
|  
 
|  
 
|-
 
|-
| 2018-09
+
| 2018-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 35.00 Bbl
 
| style="text-align: right;" | 35.00 Bbl
Line 981: Line 1,164:
 
| 34-007-21847
 
| 34-007-21847
 
|-
 
|-
| 2018-09
+
| 2018-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 62.50 Bbl
 
| style="text-align: right;" | 62.50 Bbl
Line 987: Line 1,170:
 
| WMGR123NW005
 
| WMGR123NW005
 
|-
 
|-
| 2018-09
+
| 2018-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 266.67 Bbl
 
| style="text-align: right;" | 266.67 Bbl
Line 993: Line 1,176:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2018-09
+
| 2018-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 18.33 Bbl
 
| style="text-align: right;" | 18.33 Bbl
Line 999: Line 1,182:
 
|  
 
|  
 
|-
 
|-
| 2018-10
+
| 2018-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 18.33 Bbl
 
| style="text-align: right;" | 18.33 Bbl
Line 1,005: Line 1,188:
 
| WMGR123NW005
 
| WMGR123NW005
 
|-
 
|-
| 2018-10
+
| 2018-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 223.33 Bbl
 
| style="text-align: right;" | 223.33 Bbl
Line 1,011: Line 1,194:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2018-10
+
| 2018-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 55.00 Bbl
 
| style="text-align: right;" | 55.00 Bbl
Line 1,017: Line 1,200:
 
|  
 
|  
 
|-
 
|-
| 2018-11
+
| 2018-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 66.67 Bbl
 
| style="text-align: right;" | 66.67 Bbl
Line 1,023: Line 1,206:
 
| 34-007-21847
 
| 34-007-21847
 
|-
 
|-
| 2018-11
+
| 2018-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 55.00 Bbl
 
| style="text-align: right;" | 55.00 Bbl
Line 1,029: Line 1,212:
 
| WMGR123NW005
 
| WMGR123NW005
 
|-
 
|-
| 2018-11
+
| 2018-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 91.67 Bbl
 
| style="text-align: right;" | 91.67 Bbl
Line 1,035: Line 1,218:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2018-11
+
| 2018-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 18.33 Bbl
 
| style="text-align: right;" | 18.33 Bbl
Line 1,041: Line 1,224:
 
|  
 
|  
 
|-
 
|-
| 2018-12
+
| 2018-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 201.67 Bbl
 
| style="text-align: right;" | 201.67 Bbl
Line 1,047: Line 1,230:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2018-12
+
| 2018-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 55.00 Bbl
 
| style="text-align: right;" | 55.00 Bbl
Line 1,053: Line 1,236:
 
|  
 
|  
 
|-
 
|-
| 2019-01
+
| 2019-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 88.33 Bbl
 
| style="text-align: right;" | 88.33 Bbl
Line 1,059: Line 1,242:
 
| 34-007-21847
 
| 34-007-21847
 
|-
 
|-
| 2019-01
+
| 2019-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 55.00 Bbl
 
| style="text-align: right;" | 55.00 Bbl
Line 1,065: Line 1,248:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2019-01
+
| 2019-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 18.33 Bbl
 
| style="text-align: right;" | 18.33 Bbl
Line 1,071: Line 1,254:
 
|  
 
|  
 
|-
 
|-
| 2019-02
+
| 2019-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 73.33 Bbl
 
| style="text-align: right;" | 73.33 Bbl
Line 1,077: Line 1,260:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2019-02
+
| 2019-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 108.33 Bbl
 
| style="text-align: right;" | 108.33 Bbl
Line 1,083: Line 1,266:
 
|  
 
|  
 
|-
 
|-
| 2019-03
+
| 2019-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 60.00 Bbl
 
| style="text-align: right;" | 60.00 Bbl
Line 1,089: Line 1,272:
 
| 34-155-24079
 
| 34-155-24079
 
|-
 
|-
| 2019-03
+
| 2019-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 36.67 Bbl
 
| style="text-align: right;" | 36.67 Bbl
Line 1,095: Line 1,278:
 
| PAS2D215BWAR
 
| PAS2D215BWAR
 
|-
 
|-
| 2019-03
+
| 2019-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 91.67 Bbl
 
| style="text-align: right;" | 91.67 Bbl
Line 1,120: Line 1,303:
 
| 1946129
 
| 1946129
 
| Primary Facility
 
| Primary Facility
| 01/27/2011
+
| 2011-01-27
 
| Routine/Partial Inspection
 
| Routine/Partial Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 1,127: Line 1,310:
 
| 1947488
 
| 1947488
 
| Primary Facility
 
| Primary Facility
| 01/27/2011
+
| 2011-01-27
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| Violation(s) Noted
 
| Violation(s) Noted
Line 1,134: Line 1,317:
 
| 1972506
 
| 1972506
 
| Primary Facility
 
| Primary Facility
| 05/12/2011
+
| 2011-05-12
 
| Routine/Partial Inspection
 
| Routine/Partial Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 1,141: Line 1,324:
 
| 2045183
 
| 2045183
 
| Primary Facility
 
| Primary Facility
| 02/24/2012
+
| 2012-02-24
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 1,148: Line 1,331:
 
| 2106233
 
| 2106233
 
| Primary Facility
 
| Primary Facility
| 10/10/2012
+
| 2012-10-10
 
| Routine/Partial Inspection
 
| Routine/Partial Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 1,155: Line 1,338:
 
| 2127818
 
| 2127818
 
| Primary Facility
 
| Primary Facility
| 12/11/2012
+
| 2012-12-11
 
| Follow-up Inspection
 
| Follow-up Inspection
 
| Violation(s) Noted
 
| Violation(s) Noted
Line 1,162: Line 1,345:
 
| 2221374
 
| 2221374
 
| Primary Facility
 
| Primary Facility
| 11/12/2013
+
| 2013-11-12
 
| Routine/Partial Inspection
 
| Routine/Partial Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 1,236: Line 1,419:
 
| 604081
 
| 604081
 
| 01/27/2011
 
| 01/27/2011
|  
+
| 2011-01-27
 
| 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days
 
| 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days
 
| Administrative
 
| Administrative
Line 1,244: Line 1,427:
 
| 657136
 
| 657136
 
| 12/11/2012
 
| 12/11/2012
| 11/12/2013
+
| 2012-12-11
 
| 201H - Failure to properly install the permit number, issued by the department, on a completed well.
 
| 201H - Failure to properly install the permit number, issued by the department, on a completed well.
 
| Administrative
 
| Administrative
Line 1,294: Line 1,477:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
== Fracking Activities ==
 
==== Fracking Jobs ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Job Start Date
 
!scope="col" | Job End Date
 
!scope="col" | True Vertical Depth (ft)
 
!scope="col" | Total Water Volume (gal)
 
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
| 1
 
| 12/02/2010
 
| 12/02/2010
 
| style="text-align: right;" | 5800.0
 
| style="text-align: right;" | 6134378.0
 
| style="text-align: right;" |
 
|-
 
|}
 
==== Fluid Composition Data ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Trade Name
 
!scope="col" | Supplier
 
!scope="col" | Purpose
 
!scope="col" | Ingredient Name
 
!scope="col" | CAS Number
 
!scope="col" | Additive Percentage by Mass
 
!scope="col" | Job Percentage by Mass
 
!scope="col" | Mass Used (lb)
 
|-
 
|- valign="top"
 
| rowspan="19"| 1
 
| rowspan="1"| AI -2
 
| rowspan="1"| Superior Well Services
 
| rowspan="1"| Acid Inhibitor
 
| Glycol Ether
 
| 111-76-2
 
| style="text-align: right;" | 30.0
 
| style="text-align: right;" | 0.00008000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| Super TSC
 
| rowspan="1"| Superior Well Services
 
| rowspan="1"| Scale Inhibitor
 
| Propylene glycol
 
| 57-55-6
 
| style="text-align: right;" | 50.0
 
| style="text-align: right;" | 0.00515
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="12"|
 
| rowspan="12"|
 
| rowspan="12"|
 
| Diethylene Glycol
 
| 111-46-6
 
| style="text-align: right;" | 3.5
 
| style="text-align: right;" | 0.00031
 
| style="text-align: right;" |
 
|-
 
| Proprietary Component
 
| Proprietary
 
| style="text-align: right;" | 7.0
 
| style="text-align: right;" | 0.00002000
 
| style="text-align: right;" |
 
|-
 
| Ethylene Glycol
 
| 107-21-1
 
| style="text-align: right;" | 1.0
 
| style="text-align: right;" | 0.00891
 
| style="text-align: right;" |
 
|-
 
| Polyethylene Glycol
 
| 25322-68-3
 
| style="text-align: right;" | 50.0
 
| style="text-align: right;" | 0.00446
 
| style="text-align: right;" |
 
|-
 
| Anionic copolymer
 
| Proprietary
 
| style="text-align: right;" | 10.0
 
| style="text-align: right;" | 0.00103
 
| style="text-align: right;" |
 
|-
 
| Propargyl Alcohol
 
| 107-19-7
 
| style="text-align: right;" | 30.0
 
| style="text-align: right;" | 0.00008000
 
| style="text-align: right;" |
 
|-
 
| Isopropyl Alcohol
 
| 67-63-0
 
| style="text-align: right;" | 30.0
 
| style="text-align: right;" | 0.00008000
 
| style="text-align: right;" |
 
|-
 
| Anionic polymer
 
| Proprietary
 
| style="text-align: right;" | 10.0
 
| style="text-align: right;" | 0.00103
 
| style="text-align: right;" |
 
|-
 
| Ethoxylated Alcohols
 
| 68551-12-2
 
| style="text-align: right;" | 4.0
 
| style="text-align: right;" | 0.00299
 
| style="text-align: right;" |
 
|-
 
| Mineral Spirits
 
| 8052-41-3
 
| style="text-align: right;" | 10.0
 
| style="text-align: right;" | 0.00747
 
| style="text-align: right;" |
 
|-
 
| 2-Phosphonobutane-1,2,4 tricarboxylic acid
 
| 37971-36-1
 
| style="text-align: right;" | 10.0
 
| style="text-align: right;" | 0.00103
 
| style="text-align: right;" |
 
|-
 
| Propylene Glycol
 
| 57-55-6
 
| style="text-align: right;" | 25.0
 
| style="text-align: right;" | 0.01868
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| WFR-3B
 
| rowspan="1"| Superior Well Services
 
| rowspan="1"| Friction Reducer
 
| Hydrotreated Light Distillate
 
| 64742-47-8
 
| style="text-align: right;" | 30.0
 
| style="text-align: right;" | 0.02242
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| KR-153SL
 
| rowspan="1"| Superior Well Services
 
| rowspan="1"| Biocide
 
| 2,2-Dibromo-3-nitrilo-propionamide
 
| 10222-01-2
 
| style="text-align: right;" | 20.0
 
| style="text-align: right;" | 0.00178
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| Sand
 
| rowspan="1"| Superior Well Services
 
| rowspan="1"| Proppant
 
| Crystalline Silica (quartz)
 
| 14808-60-7
 
| style="text-align: right;" | 100.0
 
| style="text-align: right;" | 13.26076
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| Acid, Hydrochloric (3)
 
| rowspan="1"| Superior Well Services
 
| rowspan="1"| Solvent
 
| Hydrochloric Acid
 
| 7647-01-0
 
| style="text-align: right;" | 3.0
 
| style="text-align: right;" | 0.03711
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| Water*
 
| rowspan="1"| PGE
 
| rowspan="1"| Carrier/Base Fluid
 
|
 
| 7732-18-5
 
| style="text-align: right;" | 100.0
 
| style="text-align: right;" | 85.408
 
| style="text-align: right;" |
 
|-
 
|}
 
For data sources see<ref>{{cite web
 
| title =FracFocus Fracking Chemicals Database
 
| date = 2019-04-02
 
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
| accessdate = 2019-06-19 }}</ref>
 
 
==References==
 
==References==
 
<references/>
 
<references/>

Revision as of 04:59, 2 August 2019

Well Details

Well ID: 37-105-21682
Loading map...
Country: United States
State: Pennsylvania
County: Potter
Municipality: Pleasant Valley Township
Operator Name: PA GEN ENERGY CO LLC
Well Pad ID: 148343
Farm/Lease Name: FISK HOLLOW PAD A 2448
License Status: Active
Spud Date: 2010-07-12
Permit Date: 2010-06-02
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.846792
Longitude: -78.156531

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2010-12-02 2010-12-02 5800.0 6134378.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 AI -2 Superior Well Services Acid Inhibitor Glycol Ether 111-76-2 30.0 0.00008000
Super TSC Superior Well Services Scale Inhibitor Propylene glycol 57-55-6 50.0 0.00515
Diethylene Glycol 111-46-6 3.5 0.00031
Proprietary Component Proprietary 7.0 0.00002000
Ethylene Glycol 107-21-1 1.0 0.00891
Polyethylene Glycol 25322-68-3 50.0 0.00446
Anionic copolymer Proprietary 10.0 0.00103
Propargyl Alcohol 107-19-7 30.0 0.00008000
Isopropyl Alcohol 67-63-0 30.0 0.00008000
Anionic polymer Proprietary 10.0 0.00103
Ethoxylated Alcohols 68551-12-2 4.0 0.00299
Mineral Spirits 8052-41-3 10.0 0.00747
2-Phosphonobutane-1,2,4 tricarboxylic acid 37971-36-1 10.0 0.00103
Propylene Glycol 57-55-6 25.0 0.01868
WFR-3B Superior Well Services Friction Reducer Hydrotreated Light Distillate 64742-47-8 30.0 0.02242
KR-153SL Superior Well Services Biocide 2,2-Dibromo-3-nitrilo-propionamide 10222-01-2 20.0 0.00178
Sand Superior Well Services Proppant Crystalline Silica (quartz) 14808-60-7 100.0 13.26076
Acid, Hydrochloric (3) Superior Well Services Solvent Hydrochloric Acid 7647-01-0 3.0 0.03711
Water* PGE Carrier/Base Fluid 7732-18-5 100.0 85.408

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 PA GEN ENERGY CO LLC 0.00 0 0.00 0 0.00 0
2011 PA GEN ENERGY CO LLC 234,262.00 312 0.00 0 0.00 0
2012 PA GEN ENERGY CO LLC 198,474.00 366 0.00 0 0.00 0
2013 PA GEN ENERGY CO LLC 132,737.00 365 0.00 0 0.00 0
2014 PA GEN ENERGY CO LLC 114,719.00 364 0.00 0 0.00 0
2015 PA GEN ENERGY CO LLC 98,740.00 365 0.00 0 0.00 0
2016 PA GEN ENERGY CO LLC 82,774.00 366 0.00 0 0.00 0
2017 PA GEN ENERGY CO LLC 75,982.00 365 0.00 0 0.00 0
2018 PA GEN ENERGY CO LLC 72,528.00 361 0.00 0 0.00 0
2019 PA GEN ENERGY CO LLC 16,843.00 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2010-S02 Drill Cuttings (in Tons) 807.21 Tons LANDFILL 100361
2010-S02 Drilling Fluid Waste (in Barrels) 67.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010-S02 Drilling Fluid Waste (in Barrels) 6,642.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2010-S02 Produced Fluid (in Barrels) 273.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010-S02 Produced Fluid (in Barrels) 251.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2011-S01 Drilling Fluid Waste (in Barrels) 1,734.29 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2011-S01 Fracing Fluid Waste (in Barrels) 1,918.89 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011-S01 Fracing Fluid Waste (in Barrels) 112.70 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2011-S01 Fracturing Fluid Waste (in Tons) 27.43 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE 004835146
2011-S01 Fracturing Fluid Waste (in Tons) 9.11 Tons LANDFILL 100361
2011-S01 Produced Fluid (in Barrels) 4,108.57 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2011-S02 Produced Fluid (in Barrels) 539.81 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 34-099-23127
2011-S02 Produced Fluid (in Barrels) 883.11 Bbl INJECTION DISPOSAL WELL 34-007-24355
2011-S02 Produced Fluid (in Barrels) 595.77 Bbl INJECTION DISPOSAL WELL 34-133-21076
2011-S02 Produced Fluid (in Barrels) 222.52 Bbl INJECTION DISPOSAL WELL 34-133-24096
2011-S02 Produced Fluid (in Barrels) 13,098.93 Bbl INJECTION DISPOSAL WELL UIC 45
2012-S01 Produced Fluid (in Barrels) 2,380.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 525-1
2012-S01 Produced Fluid (in Barrels) 1,245.00 Bbl INJECTION DISPOSAL WELL 34-151-23420
2012-S01 Produced Fluid (in Barrels) 60.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2012-S01 Produced Fluid (in Barrels) 30.00 Bbl INJECTION DISPOSAL WELL 34-155-21447
2012-S01 Produced Fluid (in Barrels) 1,957.50 Bbl INJECTION DISPOSAL WELL 34-155-21893
2012-S01 Produced Fluid (in Barrels) 1,620.50 Bbl INJECTION DISPOSAL WELL 34-155-23795
2012-S01 Produced Fluid (in Barrels) 1,716.42 Bbl REUSE OTHER THAN ROAD SPREADING
2012-S02 Produced Fluid (in Barrels) 566.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012-S02 Produced Fluid (in Barrels) 60.00 Bbl INJECTION DISPOSAL WELL 34-007-24355
2012-S02 Produced Fluid (in Barrels) 1,453.00 Bbl INJECTION DISPOSAL WELL 34-133-20525
2012-S02 Produced Fluid (in Barrels) 242.00 Bbl INJECTION DISPOSAL WELL 34-151-23420
2012-S02 Produced Fluid (in Barrels) 976.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2012-S02 Produced Fluid (in Barrels) 1,040.00 Bbl INJECTION DISPOSAL WELL 34-155-21447
2012-S02 Produced Fluid (in Barrels) 1,076.00 Bbl INJECTION DISPOSAL WELL 34-155-21893
2012-S02 Produced Fluid (in Barrels) 1,076.00 Bbl INJECTION DISPOSAL WELL 34-155-21894
2012-S02 Produced Fluid (in Barrels) 1,076.00 Bbl INJECTION DISPOSAL WELL 34-155-23203
2012-S02 Produced Fluid (in Barrels) 2,748.00 Bbl INJECTION DISPOSAL WELL 34-155-23795
2012-S02 Produced Fluid (in Barrels) 135.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S01 Produced Fluid (in Barrels) 431.67 Bbl INJECTION DISPOSAL WELL 34-133-20525
2013-S01 Produced Fluid (in Barrels) 926.67 Bbl INJECTION DISPOSAL WELL 34-151-23420
2013-S01 Produced Fluid (in Barrels) 60.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2013-S01 Produced Fluid (in Barrels) 574.43 Bbl INJECTION DISPOSAL WELL 34-155-21893
2013-S01 Produced Fluid (in Barrels) 574.45 Bbl INJECTION DISPOSAL WELL 34-155-21894
2013-S01 Produced Fluid (in Barrels) 574.45 Bbl INJECTION DISPOSAL WELL 34-155-23203
2013-S01 Produced Fluid (in Barrels) 60.00 Bbl INJECTION DISPOSAL WELL 34-155-23732
2013-S01 Produced Fluid (in Barrels) 1,935.00 Bbl INJECTION DISPOSAL WELL 34-155-23795
2013-S01 Produced Fluid (in Barrels) 20.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S02 Produced Fluid (in Barrels) 80.00 Bbl INJECTION DISPOSAL WELL 34-007-24355
2013-S02 Produced Fluid (in Barrels) 778.33 Bbl INJECTION DISPOSAL WELL 34-133-20525
2013-S02 Produced Fluid (in Barrels) 40.00 Bbl INJECTION DISPOSAL WELL 34-151-21198
2013-S02 Produced Fluid (in Barrels) 439.90 Bbl INJECTION DISPOSAL WELL 34-151-23420
2013-S02 Produced Fluid (in Barrels) 20.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2013-S02 Produced Fluid (in Barrels) 239.40 Bbl INJECTION DISPOSAL WELL 34-155-21893
2013-S02 Produced Fluid (in Barrels) 239.40 Bbl INJECTION DISPOSAL WELL 34-155-21894
2013-S02 Produced Fluid (in Barrels) 58.33 Bbl INJECTION DISPOSAL WELL 34-155-22403
2013-S02 Produced Fluid (in Barrels) 239.40 Bbl INJECTION DISPOSAL WELL 34-155-23203
2013-S02 Produced Fluid (in Barrels) 723.33 Bbl INJECTION DISPOSAL WELL 34-155-23795
2013-S02 Produced Fluid (in Barrels) 1,149.31 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S01 Produced Fluid (in Barrels) 280.00 Bbl INJECTION DISPOSAL WELL 34-133-20525
2014-S01 Produced Fluid (in Barrels) 120.00 Bbl INJECTION DISPOSAL WELL 34-151-23420
2014-S01 Produced Fluid (in Barrels) 196.67 Bbl INJECTION DISPOSAL WELL 34-155-21438
2014-S01 Produced Fluid (in Barrels) 333.33 Bbl INJECTION DISPOSAL WELL 34-155-21447
2014-S01 Produced Fluid (in Barrels) 152.79 Bbl INJECTION DISPOSAL WELL 34-155-21893
2014-S01 Produced Fluid (in Barrels) 152.79 Bbl INJECTION DISPOSAL WELL 34-155-21894
2014-S01 Produced Fluid (in Barrels) 20.00 Bbl INJECTION DISPOSAL WELL 34-155-22403
2014-S01 Produced Fluid (in Barrels) 300.03 Bbl INJECTION DISPOSAL WELL 34-155-23196
2014-S01 Produced Fluid (in Barrels) 152.79 Bbl INJECTION DISPOSAL WELL 34-155-23203
2014-S01 Produced Fluid (in Barrels) 219.17 Bbl INJECTION DISPOSAL WELL 34-155-23223
2014-S01 Produced Fluid (in Barrels) 653.41 Bbl INJECTION DISPOSAL WELL 34-155-23732
2014-S01 Produced Fluid (in Barrels) 236.67 Bbl INJECTION DISPOSAL WELL 34-155-23759
2014-S01 Produced Fluid (in Barrels) 275.83 Bbl INJECTION DISPOSAL WELL 34-155-23795
2014-S01 Produced Fluid (in Barrels) 461.67 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S02 Produced Fluid (in Barrels) 2,020.98 Bbl INJECTION DISPOSAL WELL 34-007-21847
2014-S02 Produced Fluid (in Barrels) 20.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2014-S02 Produced Fluid (in Barrels) 40.00 Bbl INJECTION DISPOSAL WELL 34-155-23196
2014-S02 Produced Fluid (in Barrels) 20.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2014-S02 Produced Fluid (in Barrels) 20.00 Bbl INJECTION DISPOSAL WELL 34-155-23732
2014-S02 Produced Fluid (in Barrels) 678.33 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S01 Produced Fluid (in Barrels) 351.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2015-S01 Produced Fluid (in Barrels) 1,085.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2015-S01 Produced Fluid (in Barrels) 6.67 Bbl INJECTION DISPOSAL WELL 34-155-21893
2015-S01 Produced Fluid (in Barrels) 6.67 Bbl INJECTION DISPOSAL WELL 34-155-21894
2015-S01 Produced Fluid (in Barrels) 6.67 Bbl INJECTION DISPOSAL WELL 34-155-23203
2015-S01 Produced Fluid (in Barrels) 232.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015-S01 Produced Fluid (in Barrels) 1,103.17 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S02 Produced Fluid (in Barrels) 223.17 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2015-S02 Produced Fluid (in Barrels) 954.33 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2015-S02 Produced Fluid (in Barrels) 70.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2015-S02 Produced Fluid (in Barrels) 119.83 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015-S02 Produced Fluid (in Barrels) 136.83 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015-S02 Produced Fluid (in Barrels) 574.83 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S01 Produced Fluid (in Barrels) RWC 802 231.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2016-S01 Produced Fluid (in Barrels) RWC 802 1,640.67 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016-S01 Produced Fluid (in Barrels) RWC 802 7.00 Bbl INJECTION DISPOSAL WELL 34-007-2-3097
2016-S01 Produced Fluid (in Barrels) RWC 802 7.00 Bbl INJECTION DISPOSAL WELL 34-007-2-3177
2016-S01 Produced Fluid (in Barrels) RWC 802 7.00 Bbl INJECTION DISPOSAL WELL 34-007-2-3692
2016-S01 Produced Fluid (in Barrels) RWC 802 70.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2016-S01 Produced Fluid (in Barrels) RWC 802 7.00 Bbl INJECTION DISPOSAL WELL 34-007-23262
2016-S01 Produced Fluid (in Barrels) RWC 802 7.00 Bbl INJECTION DISPOSAL WELL 34-007-24355
2016-S02 Produced Fluid (in Barrels) RWC 802 102.33 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0102784
2016-S02 Produced Fluid (in Barrels) RWC 802 35.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2016-S02 Produced Fluid (in Barrels) RWC 802 1,805.83 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2017-M01 Other Oil & Gas Wastes (in Barrels) RWC 899 56.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-M01 Produced Fluid (in Barrels) RWC 802 35.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017-M01 Produced Fluid (in Barrels) RWC 802 247.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-M02 Other Oil & Gas Wastes (in Barrels) RWC 899 30.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-M02 Produced Fluid (in Barrels) RWC 802 264.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-M03 Other Oil & Gas Wastes (in Barrels) RWC 899 21.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-M03 Produced Fluid (in Barrels) RWC 802 280.17 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-M05 Produced Fluid (in Barrels) RWC 802 298.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-M06 Other Oil & Gas Wastes (in Barrels) RWC 899 25.83 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-M06 Produced Fluid (in Barrels) RWC 802 54.17 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017-M06 Produced Fluid (in Barrels) RWC 802 261.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-M07 Produced Fluid (in Barrels) RWC 802 353.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-M08 Produced Fluid (in Barrels) RWC 802 271.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-M09 Produced Fluid (in Barrels) RWC 802 18.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017-M09 Produced Fluid (in Barrels) RWC 802 324.17 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-M09 Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 0.03 Tons LANDFILL 101397
2017-M10 Produced Fluid (in Barrels) RWC 802 256.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-M11 Produced Fluid (in Barrels) RWC 802 310.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-M12 Produced Fluid (in Barrels) RWC 802 287.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-M01 Produced Fluid (in Barrels) RWC 802 30.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2018-M01 Produced Fluid (in Barrels) RWC 802 35.83 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-M01 Produced Fluid (in Barrels) RWC 802 73.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-M01 Produced Fluid (in Barrels) RWC 802 93.33 Bbl REUSE (AT WELL PAD)
2018-M02 Other Oil & Gas Wastes (in Barrels) RWC 899 45.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-M02 Produced Fluid (in Barrels) RWC 802 161.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-M02 Produced Fluid (in Barrels) RWC 802 73.33 Bbl REUSE (AT WELL PAD)
2018-M03 Produced Fluid (in Barrels) RWC 802 330.83 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-M04 Produced Fluid (in Barrels) RWC 802 18.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018-M04 Produced Fluid (in Barrels) RWC 802 200.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-M05 Produced Fluid (in Barrels) RWC 802 300.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-M06 Produced Fluid (in Barrels) RWC 802 287.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-M06 Produced Fluid (in Barrels) RWC 802 18.33 Bbl REUSE (AT WELL PAD)
2018-M07 Produced Fluid (in Barrels) RWC 802 139.17 Bbl INJECTION DISPOSAL WELL 34-007-21847
2018-M07 Produced Fluid (in Barrels) RWC 802 94.17 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-M07 Produced Fluid (in Barrels) RWC 802 17.50 Bbl REUSE (AT WELL PAD)
2018-M08 Produced Fluid (in Barrels) RWC 802 124.17 Bbl INJECTION DISPOSAL WELL 34-007-21847
2018-M08 Produced Fluid (in Barrels) RWC 802 195.00 Bbl REUSE (AT WELL PAD)
2018-M09 Produced Fluid (in Barrels) RWC 802 35.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2018-M09 Produced Fluid (in Barrels) RWC 802 62.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018-M09 Produced Fluid (in Barrels) RWC 802 266.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-M09 Produced Fluid (in Barrels) RWC 802 18.33 Bbl REUSE (AT WELL PAD)
2018-M10 Produced Fluid (in Barrels) RWC 802 18.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018-M10 Produced Fluid (in Barrels) RWC 802 223.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-M10 Produced Fluid (in Barrels) RWC 802 55.00 Bbl REUSE (AT WELL PAD)
2018-M11 Produced Fluid (in Barrels) RWC 802 66.67 Bbl INJECTION DISPOSAL WELL 34-007-21847
2018-M11 Produced Fluid (in Barrels) RWC 802 55.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018-M11 Produced Fluid (in Barrels) RWC 802 91.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-M11 Produced Fluid (in Barrels) RWC 802 18.33 Bbl REUSE (AT WELL PAD)
2018-M12 Produced Fluid (in Barrels) RWC 802 201.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-M12 Produced Fluid (in Barrels) RWC 802 55.00 Bbl REUSE (AT WELL PAD)
2019-M01 Produced Fluid (in Barrels) RWC 802 88.33 Bbl INJECTION DISPOSAL WELL 34-007-21847
2019-M01 Produced Fluid (in Barrels) RWC 802 55.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019-M01 Produced Fluid (in Barrels) RWC 802 18.33 Bbl REUSE (AT WELL PAD)
2019-M02 Produced Fluid (in Barrels) RWC 802 73.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019-M02 Produced Fluid (in Barrels) RWC 802 108.33 Bbl REUSE (AT WELL PAD)
2019-M03 Produced Fluid (in Barrels) RWC 802 60.00 Bbl INJECTION DISPOSAL WELL 34-155-24079
2019-M03 Produced Fluid (in Barrels) RWC 802 36.67 Bbl INJECTION DISPOSAL WELL PAS2D215BWAR
2019-M03 Produced Fluid (in Barrels) RWC 802 91.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1946129 Primary Facility 2011-01-27 Routine/Partial Inspection No Violations Noted
1947488 Primary Facility 2011-01-27 Routine/Complete Inspection Violation(s) Noted
1972506 Primary Facility 2011-05-12 Routine/Partial Inspection No Violations Noted Bubbles observed at well head- told Bob Young & he said they were aware of it
2045183 Primary Facility 2012-02-24 Routine/Complete Inspection No Violations Noted An inspection was conducted at the Fisk Hollow Pad A on Feb. 24, 2012. The ground was frozen and snow covered. The site ID sign and E&S plan and site perimeter were observed. The collection systems for production fluid were also observed. There were no erosion issues or leaks and spills detected. No new violations were cited during this inspection. - MRN
2106233 Primary Facility 2012-10-10 Routine/Partial Inspection No Violations Noted
2127818 Primary Facility 2012-12-11 Follow-up Inspection Violation(s) Noted
2221374 Primary Facility 2013-11-12 Routine/Partial Inspection No Violations Noted A routine partial inspection of the Fisk Hollow Pleasant Valley Pad A site in Pleasant Valley Township, Potter County was conducted on 11/12/13, 2013 in response to a Notice of Termination and Well Site Restoration Reports received by the Department. The FH1949 (105-21302) well has been plugged. Six other wells are in production. The site was determined to meet the requirements of 25 Pa Code §102.22(a)(2) (i) Permanent Stabilization at this time. A minimum uniform 70% perennial vegetative cover, with a density capable of resisting accelerated erosion and sedimentation was observed. Other areas are stabilized with stone. The Well Site Restoration Report will be approved at this time. The approval of the Notice of Termination will be recommended. No violations were cited during this inspection.
2485776 Primary Facility 2016-05-19 Routine/Complete Inspection No Violations Noted
2529267 Primary Facility 2016-10-13 Routine/Complete Inspection No Violations Noted Routine inspection at Fisk Hollow Pleasant Valley Pad A. Site is stable, no erosion issues noted or evidence of spills/releases. TLT
2556019 Primary Facility 2017-01-26 Routine/Complete Inspection No Violations Noted
2631713 Primary Facility 2017-08-29 Incident- Response to Accident or Event No Violations Noted On 8/29/17 at 1014 hrs I conducted an inspection at the Fisk Hollow Pad A well site to follow up on a small spill (less than 1 barrel) that was reported by PGE. It was mostly cloudy and 59 degrees F.

On 8/24/17 Amber Oyler, PGE Environmental Manager, contacted the Department of Environmental Protection (DEP) to report that approximately 25 gallons of hydraulic oil had been released to the pad surface at the Fisk Hollow pad A well site. She stated that she was notified of the spill at 1030 hrs on 8/24/17 by personnel at the site. At that time, absorbent pads were being used to soak up standing liquid. She stated that affected pad material would be removed and sent for disposal.

On 8/25/17, Ms. Oyler provided an update by email and included a photo to document that the spill had been cleaned up.

During my inspection, I observed the well pad and spill area. A new area of gravel was observed on the well pad to the southwest of the compressor building. It was apparent that pad soil had been removed in the spil

2700024 Primary Facility 2018-02-21 Routine/Complete Inspection Outstanding Violations - Viols Req'd At the time of this inspection there was an open violation(OUSTS) associated with this well. On 1-27-2011 a 78.86 violation for defective cement ,violation ID# 604081 included in inspection ID # 1947488 was issued to the operator. At the time of this inspection this violation had not been corrected. No new violations were noted at the time of this inspection.
2733595 Primary Facility 2018-05-18 Routine/Complete Inspection No Violations Noted At the time of this inspection there was an open violation(OUSTS) associated with this well. On 1-27-2011 a 78.86 violation for defective cement, violation ID # 604081 included in inspection ID # 1947488 was issued to the operator. At the time of this inspection the violation had not been corrected. No new violations were noted at the time of this inspection.
2802413 Primary Facility 2018-11-09 Administrative/File Review No Violations Noted Admin inspection for purpose of linking to a plugging COA.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1947488 604081 01/27/2011 2011-01-27 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days Administrative
2127818 657136 12/11/2012 2012-12-11 201H - Failure to properly install the permit number, issued by the department, on a completed well. Administrative
2700024 811637 2018-02-21 2018-11-09 78.86* Administrative

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
604081 267687 NOV - Notice of Violation
811637 369373 COA - Consent Order and Agreement

For data sources see[7]

References