If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-115-21666 | | Well ID: 37-115-21666 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 41.831883, -75.5820 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 21: | Line 21: | ||
| License Status: Active | | License Status: Active | ||
|- | |- | ||
− | | Spud Date: 04 | + | | Spud Date: 2014-04-30 |
|- | |- | ||
− | | Permit Date: | + | | Permit Date: 2014-02-21 |
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
Line 49: | Line 49: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | | 1 | ||
+ | | 2014-07-17 | ||
+ | | 2014-08-06 | ||
+ | | style="text-align: right;" | 7060 | ||
+ | | style="text-align: right;" | 14,124,700.0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="25"| 1 | ||
+ | | rowspan="4"| Plexslick 957 | ||
+ | | rowspan="4"| Chemplex | ||
+ | | rowspan="4"| Friction Reducer | ||
+ | | Poly (acrylamide-co-acrylic acid), partial sodium salt | ||
+ | | 62649-23-4 | ||
+ | | style="text-align: right;" | 35 | ||
+ | | style="text-align: right;" | 0.0305006 | ||
+ | | style="text-align: right;" | 40946.4 | ||
+ | |- | ||
+ | | Nonionic Surfactants | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 1.5 | ||
+ | | style="text-align: right;" | 0.00130717 | ||
+ | | style="text-align: right;" | 1754.85 | ||
+ | |- | ||
+ | | Paraffinic, Naphtehenic Solvent | ||
+ | | 64742-47-8 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.0261433 | ||
+ | | style="text-align: right;" | 35096.9 | ||
+ | |- | ||
+ | | Ammonium Chloride | ||
+ | | 12125-02-9 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00435722 | ||
+ | | style="text-align: right;" | 5849.49 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="4"| Plexcide 15G | ||
+ | | rowspan="4"| Chemplex | ||
+ | | rowspan="4"| Biocide | ||
+ | | Glutaraldehyde | ||
+ | | 111-30-8 | ||
+ | | style="text-align: right;" | 14 | ||
+ | | style="text-align: right;" | 0.00310316 | ||
+ | | style="text-align: right;" | 4165.92 | ||
+ | |- | ||
+ | | Ethanol | ||
+ | | 64-17-5 | ||
+ | | style="text-align: right;" | 3 | ||
+ | | style="text-align: right;" | 0.000664962 | ||
+ | | style="text-align: right;" | 892.698 | ||
+ | |- | ||
+ | | Didecyl Dimethyl Ammonium Chloride | ||
+ | | 7173-51-5 | ||
+ | | style="text-align: right;" | 3 | ||
+ | | style="text-align: right;" | 0.000664962 | ||
+ | | style="text-align: right;" | 892.698 | ||
+ | |- | ||
+ | | Alkyl Dimethyl Benzyl Ammonium Chloride | ||
+ | | 68424-85-1 | ||
+ | | style="text-align: right;" | 3 | ||
+ | | style="text-align: right;" | 0.000664962 | ||
+ | | style="text-align: right;" | 892.698 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Water | ||
+ | | rowspan="1"| Rain for Rent | ||
+ | | rowspan="1"| Carrier/Base Fluid | ||
+ | | Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 88.2943 | ||
+ | | style="text-align: right;" | 118,533,000.0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| Greenhib 679 | ||
+ | | rowspan="2"| Chemplex | ||
+ | | rowspan="2"| Friction Reducer | ||
+ | | Proprietary | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 35 | ||
+ | | style="text-align: right;" | 0.00860404 | ||
+ | | style="text-align: right;" | 11550.7 | ||
+ | |- | ||
+ | | Glycerine | ||
+ | | 56-81-5 | ||
+ | | style="text-align: right;" | 20 | ||
+ | | style="text-align: right;" | 0.00491659 | ||
+ | | style="text-align: right;" | 6600.43 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="3"| Ferriplex 40 | ||
+ | | rowspan="3"| Chemplex | ||
+ | | rowspan="3"| Iron Control | ||
+ | | Sodium Hydroxide | ||
+ | | 1310-73-2 | ||
+ | | style="text-align: right;" | 1 | ||
+ | | style="text-align: right;" | 0.00003152 | ||
+ | | style="text-align: right;" | 42.309 | ||
+ | |- | ||
+ | | Sodium Sulfate Anhydrous | ||
+ | | 7757-82-6 | ||
+ | | style="text-align: right;" | 2 | ||
+ | | style="text-align: right;" | 0.00006303 | ||
+ | | style="text-align: right;" | 84.618 | ||
+ | |- | ||
+ | | Trisodium Nitrilotriacetate | ||
+ | | 5064-31-3 | ||
+ | | style="text-align: right;" | 40 | ||
+ | | style="text-align: right;" | 0.00126063 | ||
+ | | style="text-align: right;" | 1692.37 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="4"| Plexbreak 145 | ||
+ | | rowspan="4"| Chemplex | ||
+ | | rowspan="4"| Non-Emulsifier | ||
+ | | Cocamide Based Surfactant | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.00009309 | ||
+ | | style="text-align: right;" | 124.975 | ||
+ | |- | ||
+ | | Diethanolamine | ||
+ | | 111-42-2 | ||
+ | | style="text-align: right;" | 3 | ||
+ | | style="text-align: right;" | 0.00002793 | ||
+ | | style="text-align: right;" | 37.492 | ||
+ | |- | ||
+ | | Methyl Alcohol | ||
+ | | 67-56-1 | ||
+ | | style="text-align: right;" | 15 | ||
+ | | style="text-align: right;" | 0.000139639 | ||
+ | | style="text-align: right;" | 187.462 | ||
+ | |- | ||
+ | | 2-Butoxyethanol | ||
+ | | 111-76-2 | ||
+ | | style="text-align: right;" | 15 | ||
+ | | style="text-align: right;" | 0.000139639 | ||
+ | | style="text-align: right;" | 187.462 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="5"| Plexhib 256 | ||
+ | | rowspan="5"| Chemplex | ||
+ | | rowspan="5"| Acid Inhibitor | ||
+ | | Thiourea/Formaldehyde Copolymer | ||
+ | | 68527-49-1 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.000250186 | ||
+ | | style="text-align: right;" | 335.87 | ||
+ | |- | ||
+ | | C-14 to C-16 Alpha Olefins | ||
+ | | 64743-02-8 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00004170 | ||
+ | | style="text-align: right;" | 55.978 | ||
+ | |- | ||
+ | | Methyl Alcohol | ||
+ | | 67-56-1 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.000500372 | ||
+ | | style="text-align: right;" | 671.739 | ||
+ | |- | ||
+ | | Propargyl Alcohol | ||
+ | | 107-19-7 | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.00008340 | ||
+ | | style="text-align: right;" | 111.957 | ||
+ | |- | ||
+ | | Polyethoxylated Alcohol Surfactant | ||
+ | | 68951-67-7 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.000250186 | ||
+ | | style="text-align: right;" | 335.87 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Sand (Proppant) | ||
+ | | rowspan="1"| TSS | ||
+ | | rowspan="1"| Proppant | ||
+ | | Silica Substrate | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 11.0481 | ||
+ | | style="text-align: right;" | 14,831,800.0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Hydrochloric Acid (15%) | ||
+ | | rowspan="1"| Reagent | ||
+ | | rowspan="1"| Acidizing | ||
+ | | Hydrochloric Acid | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 15 | ||
+ | | style="text-align: right;" | 0.0778195 | ||
+ | | style="text-align: right;" | 104471 | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =FracFocus Fracking Chemicals Database | ||
+ | | date = 2019-04-02 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-06-19 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 129: | Line 352: | ||
!scope="col" | Waste Facility ID | !scope="col" | Waste Facility ID | ||
|- | |- | ||
− | | 2014- | + | | 2014-S01 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 1,483.41 Tons | | style="text-align: right;" | 1,483.41 Tons | ||
Line 135: | Line 358: | ||
| 101247 | | 101247 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 223.33 Tons | | style="text-align: right;" | 223.33 Tons | ||
Line 141: | Line 364: | ||
| 101247 | | 101247 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 1,692.30 Bbl | | style="text-align: right;" | 1,692.30 Bbl | ||
Line 147: | Line 370: | ||
| WMGR123NE001 | | WMGR123NE001 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 12,504.79 Bbl | | style="text-align: right;" | 12,504.79 Bbl | ||
Line 153: | Line 376: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 8,137.23 Bbl | | style="text-align: right;" | 8,137.23 Bbl | ||
Line 159: | Line 382: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 679.00 Bbl | | style="text-align: right;" | 679.00 Bbl | ||
Line 165: | Line 388: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 40.88 Bbl | | style="text-align: right;" | 40.88 Bbl | ||
Line 171: | Line 394: | ||
| WMGR123NE001 | | WMGR123NE001 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 13,469.94 Bbl | | style="text-align: right;" | 13,469.94 Bbl | ||
Line 177: | Line 400: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2016- | + | | 2016-S01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 4,453.61 Bbl | | style="text-align: right;" | 4,453.61 Bbl | ||
Line 183: | Line 406: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2016- | + | | 2016-S02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 83.24 Bbl | | style="text-align: right;" | 83.24 Bbl | ||
Line 189: | Line 412: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2016- | + | | 2016-S02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 1,920.68 Bbl | | style="text-align: right;" | 1,920.68 Bbl | ||
Line 195: | Line 418: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2016- | + | | 2016-S02 |
| Waste Water Treatment Sludge (in Tons) RWC 804 | | Waste Water Treatment Sludge (in Tons) RWC 804 | ||
| style="text-align: right;" | 6.17 Tons | | style="text-align: right;" | 6.17 Tons | ||
Line 201: | Line 424: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 144.33 Bbl | | style="text-align: right;" | 144.33 Bbl | ||
Line 207: | Line 430: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 180.42 Bbl | | style="text-align: right;" | 180.42 Bbl | ||
Line 213: | Line 436: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 181.12 Bbl | | style="text-align: right;" | 181.12 Bbl | ||
Line 219: | Line 442: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 43.92 Bbl | | style="text-align: right;" | 43.92 Bbl | ||
Line 225: | Line 448: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 30.67 Bbl | | style="text-align: right;" | 30.67 Bbl | ||
Line 231: | Line 454: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 304.15 Bbl | | style="text-align: right;" | 304.15 Bbl | ||
Line 237: | Line 460: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 204.19 Bbl | | style="text-align: right;" | 204.19 Bbl | ||
Line 243: | Line 466: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 190.82 Bbl | | style="text-align: right;" | 190.82 Bbl | ||
Line 249: | Line 472: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 22.51 Bbl | | style="text-align: right;" | 22.51 Bbl | ||
Line 255: | Line 478: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 99.28 Bbl | | style="text-align: right;" | 99.28 Bbl | ||
Line 261: | Line 484: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 26.61 Bbl | | style="text-align: right;" | 26.61 Bbl | ||
Line 267: | Line 490: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 103.77 Bbl | | style="text-align: right;" | 103.77 Bbl | ||
Line 273: | Line 496: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M07 |
| Synthetic Liner Materials (in Tons) RWC 806 | | Synthetic Liner Materials (in Tons) RWC 806 | ||
| style="text-align: right;" | 0.89 Tons | | style="text-align: right;" | 0.89 Tons | ||
Line 279: | Line 502: | ||
| 101247 | | 101247 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 171.43 Bbl | | style="text-align: right;" | 171.43 Bbl | ||
Line 285: | Line 508: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 278.27 Bbl | | style="text-align: right;" | 278.27 Bbl | ||
Line 291: | Line 514: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 188.86 Bbl | | style="text-align: right;" | 188.86 Bbl | ||
Line 297: | Line 520: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 330.94 Bbl | | style="text-align: right;" | 330.94 Bbl | ||
Line 303: | Line 526: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 197.69 Bbl | | style="text-align: right;" | 197.69 Bbl | ||
Line 309: | Line 532: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 171.70 Bbl | | style="text-align: right;" | 171.70 Bbl | ||
Line 315: | Line 538: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 167.92 Bbl | | style="text-align: right;" | 167.92 Bbl | ||
Line 321: | Line 544: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 98.64 Bbl | | style="text-align: right;" | 98.64 Bbl | ||
Line 327: | Line 550: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 64.11 Bbl | | style="text-align: right;" | 64.11 Bbl | ||
Line 333: | Line 556: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 136.44 Bbl | | style="text-align: right;" | 136.44 Bbl | ||
Line 339: | Line 562: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 34.11 Bbl | | style="text-align: right;" | 34.11 Bbl | ||
Line 345: | Line 568: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 96.22 Bbl | | style="text-align: right;" | 96.22 Bbl | ||
Line 351: | Line 574: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 24.05 Bbl | | style="text-align: right;" | 24.05 Bbl | ||
Line 357: | Line 580: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 18.58 Bbl | | style="text-align: right;" | 18.58 Bbl | ||
Line 363: | Line 586: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 74.32 Bbl | | style="text-align: right;" | 74.32 Bbl | ||
Line 369: | Line 592: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 45.16 Bbl | | style="text-align: right;" | 45.16 Bbl | ||
Line 375: | Line 598: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 97.64 Bbl | | style="text-align: right;" | 97.64 Bbl | ||
Line 381: | Line 604: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 47.03 Bbl | | style="text-align: right;" | 47.03 Bbl | ||
Line 387: | Line 610: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 15.05 Bbl | | style="text-align: right;" | 15.05 Bbl | ||
Line 393: | Line 616: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 95.52 Bbl | | style="text-align: right;" | 95.52 Bbl | ||
Line 399: | Line 622: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 23.88 Bbl | | style="text-align: right;" | 23.88 Bbl | ||
Line 405: | Line 628: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 146.57 Bbl | | style="text-align: right;" | 146.57 Bbl | ||
Line 411: | Line 634: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 197.42 Bbl | | style="text-align: right;" | 197.42 Bbl | ||
Line 417: | Line 640: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 46.08 Bbl | | style="text-align: right;" | 46.08 Bbl | ||
Line 423: | Line 646: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 159.17 Bbl | | style="text-align: right;" | 159.17 Bbl | ||
Line 429: | Line 652: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 44.96 Bbl | | style="text-align: right;" | 44.96 Bbl | ||
Line 435: | Line 658: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2019- | + | | 2019-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 144.33 Bbl | | style="text-align: right;" | 144.33 Bbl | ||
Line 441: | Line 664: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2019- | + | | 2019-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 12.12 Bbl | | style="text-align: right;" | 12.12 Bbl | ||
Line 447: | Line 670: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2019- | + | | 2019-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 156.40 Bbl | | style="text-align: right;" | 156.40 Bbl | ||
Line 453: | Line 676: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2019- | + | | 2019-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 79.16 Bbl | | style="text-align: right;" | 79.16 Bbl | ||
Line 459: | Line 682: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2019- | + | | 2019-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 116.99 Bbl | | style="text-align: right;" | 116.99 Bbl | ||
Line 484: | Line 707: | ||
| 2264730 | | 2264730 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2014-04-21 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 491: | Line 714: | ||
| 2266520 | | 2266520 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2014-04-29 |
| Preoperation Inspection | | Preoperation Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 498: | Line 721: | ||
| 2269181 | | 2269181 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2014-05-07 |
| Incident- Response to Accident or Event | | Incident- Response to Accident or Event | ||
| Violation(s) Noted | | Violation(s) Noted | ||
Line 505: | Line 728: | ||
| 2269675 | | 2269675 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2014-05-12 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 512: | Line 735: | ||
| 2272009 | | 2272009 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2014-04-17 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 519: | Line 742: | ||
| 2272015 | | 2272015 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2014-04-10 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 526: | Line 749: | ||
| 2272146 | | 2272146 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2014-05-21 |
| Administrative/File Review | | Administrative/File Review | ||
| No Violations Noted | | No Violations Noted | ||
Line 533: | Line 756: | ||
| 2273676 | | 2273676 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2014-05-21 |
| Follow-up Inspection | | Follow-up Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 540: | Line 763: | ||
| 2285941 | | 2285941 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2014-05-21 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 633: | Line 856: | ||
| 695359 | | 695359 | ||
| 05/07/2014 | | 05/07/2014 | ||
− | | | + | | 2014-05-07 |
| 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | ||
| Environmental Health & Safety | | Environmental Health & Safety | ||
Line 641: | Line 864: | ||
| 695361 | | 695361 | ||
| 05/07/2014 | | 05/07/2014 | ||
− | | | + | | 2014-05-07 |
| 91.34A - Failure to take all necessary measures to prevent spill. Inadequate diking, potential pollution | | 91.34A - Failure to take all necessary measures to prevent spill. Inadequate diking, potential pollution | ||
| Environmental Health & Safety | | Environmental Health & Safety | ||
Line 649: | Line 872: | ||
| 695362 | | 695362 | ||
| 05/07/2014 | | 05/07/2014 | ||
− | | | + | | 2014-05-07 |
| SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | ||
| Environmental Health & Safety | | Environmental Health & Safety | ||
Line 671: | Line 894: | ||
| Administrative Close Out | | Administrative Close Out | ||
| | | | ||
− | | 09 | + | | 2014-09-10 |
| style="text-align: right;" | | | style="text-align: right;" | | ||
| style="text-align: right;" | | | style="text-align: right;" | | ||
Line 680: | Line 903: | ||
| Administrative Close Out | | Administrative Close Out | ||
| | | | ||
− | | 09 | + | | 2014-09-10 |
| style="text-align: right;" | | | style="text-align: right;" | | ||
| style="text-align: right;" | | | style="text-align: right;" | | ||
Line 689: | Line 912: | ||
| Administrative Close Out | | Administrative Close Out | ||
| | | | ||
− | | 09 | + | | 2014-09-10 |
| style="text-align: right;" | | | style="text-align: right;" | | ||
| style="text-align: right;" | | | style="text-align: right;" | | ||
Line 700: | Line 923: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==References== | ==References== | ||
<references/> | <references/> |
Well ID: 37-115-21666 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.831883,"lon":-75.582,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Jackson Township | |
Operator Name: CABOT OIL & GAS CORP | |
Well Pad ID: 150898 | |
Farm/Lease Name: SLOCUM S 1 | |
License Status: Active | |
Spud Date: 2014-04-30 | |
Permit Date: 2014-02-21 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.831883 | |
Longitude: -75.5820 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2014-07-17 | 2014-08-06 | 7060 | 14,124,700.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Plexslick 957 | Chemplex | Friction Reducer | Poly (acrylamide-co-acrylic acid), partial sodium salt | 62649-23-4 | 35 | 0.0305006 | 40946.4 |
Nonionic Surfactants | Proprietary | 1.5 | 0.00130717 | 1754.85 | ||||
Paraffinic, Naphtehenic Solvent | 64742-47-8 | 30 | 0.0261433 | 35096.9 | ||||
Ammonium Chloride | 12125-02-9 | 5 | 0.00435722 | 5849.49 | ||||
Plexcide 15G | Chemplex | Biocide | Glutaraldehyde | 111-30-8 | 14 | 0.00310316 | 4165.92 | |
Ethanol | 64-17-5 | 3 | 0.000664962 | 892.698 | ||||
Didecyl Dimethyl Ammonium Chloride | 7173-51-5 | 3 | 0.000664962 | 892.698 | ||||
Alkyl Dimethyl Benzyl Ammonium Chloride | 68424-85-1 | 3 | 0.000664962 | 892.698 | ||||
Water | Rain for Rent | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 88.2943 | 118,533,000.0 | |
Greenhib 679 | Chemplex | Friction Reducer | Proprietary | Proprietary | 35 | 0.00860404 | 11550.7 | |
Glycerine | 56-81-5 | 20 | 0.00491659 | 6600.43 | ||||
Ferriplex 40 | Chemplex | Iron Control | Sodium Hydroxide | 1310-73-2 | 1 | 0.00003152 | 42.309 | |
Sodium Sulfate Anhydrous | 7757-82-6 | 2 | 0.00006303 | 84.618 | ||||
Trisodium Nitrilotriacetate | 5064-31-3 | 40 | 0.00126063 | 1692.37 | ||||
Plexbreak 145 | Chemplex | Non-Emulsifier | Cocamide Based Surfactant | Proprietary | 10 | 0.00009309 | 124.975 | |
Diethanolamine | 111-42-2 | 3 | 0.00002793 | 37.492 | ||||
Methyl Alcohol | 67-56-1 | 15 | 0.000139639 | 187.462 | ||||
2-Butoxyethanol | 111-76-2 | 15 | 0.000139639 | 187.462 | ||||
Plexhib 256 | Chemplex | Acid Inhibitor | Thiourea/Formaldehyde Copolymer | 68527-49-1 | 30 | 0.000250186 | 335.87 | |
C-14 to C-16 Alpha Olefins | 64743-02-8 | 5 | 0.00004170 | 55.978 | ||||
Methyl Alcohol | 67-56-1 | 60 | 0.000500372 | 671.739 | ||||
Propargyl Alcohol | 107-19-7 | 10 | 0.00008340 | 111.957 | ||||
Polyethoxylated Alcohol Surfactant | 68951-67-7 | 30 | 0.000250186 | 335.87 | ||||
Sand (Proppant) | TSS | Proppant | Silica Substrate | 14808-60-7 | 100 | 11.0481 | 14,831,800.0 | |
Hydrochloric Acid (15%) | Reagent | Acidizing | Hydrochloric Acid | 7647-01-0 | 15 | 0.0778195 | 104471 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | CABOT OIL & GAS CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | CABOT OIL & GAS CORP | 1,836,796.58 | 219 | 0.00 | 0 | 0.00 | 0 |
2016 | CABOT OIL & GAS CORP | 1,771,194.61 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CABOT OIL & GAS CORP | 1,164,060.63 | 359 | 0.00 | 0 | 0.00 | 0 |
2018 | CABOT OIL & GAS CORP | 978,178.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CABOT OIL & GAS CORP | 219,342.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2014-S01 | Drill Cuttings (in Tons) | 1,483.41 Tons | LANDFILL | 101247 |
2014-S02 | Drill Cuttings (in Tons) | 223.33 Tons | LANDFILL | 101247 |
2014-S02 | Fracing Fluid Waste (in Barrels) | 1,692.30 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2014-S02 | Fracing Fluid Waste (in Barrels) | 12,504.79 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015-S01 | Fracing Fluid Waste (in Barrels) | 8,137.23 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015-S01 | Produced Fluid (in Barrels) | 679.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015-S02 | Produced Fluid (in Barrels) | 40.88 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2015-S02 | Produced Fluid (in Barrels) | 13,469.94 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2016-S01 | Produced Fluid (in Barrels) RWC 802 | 4,453.61 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 83.24 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE004 |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 1,920.68 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2016-S02 | Waste Water Treatment Sludge (in Tons) RWC 804 | 6.17 Tons | LANDFILL | 301358 |
2017-M01 | Produced Fluid (in Barrels) RWC 802 | 144.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017-M01 | Produced Fluid (in Barrels) RWC 802 | 180.42 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2017-M02 | Produced Fluid (in Barrels) RWC 802 | 181.12 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017-M02 | Produced Fluid (in Barrels) RWC 802 | 43.92 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 30.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 304.15 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2017-M04 | Produced Fluid (in Barrels) RWC 802 | 204.19 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2017-M05 | Produced Fluid (in Barrels) RWC 802 | 190.82 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 22.51 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 99.28 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 26.61 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 103.77 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2017-M07 | Synthetic Liner Materials (in Tons) RWC 806 | 0.89 Tons | LANDFILL | 101247 |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 171.43 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 278.27 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017-M10 | Produced Fluid (in Barrels) RWC 802 | 188.86 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017-M11 | Produced Fluid (in Barrels) RWC 802 | 330.94 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 197.69 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 171.70 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 167.92 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 98.64 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 64.11 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 136.44 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 34.11 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 96.22 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 24.05 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 18.58 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 74.32 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 45.16 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 97.64 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 47.03 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 15.05 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 95.52 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 23.88 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 146.57 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 197.42 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 46.08 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 159.17 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 44.96 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 144.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 12.12 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 156.40 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 79.16 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 116.99 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2264730 | Primary Facility | 2014-04-21 | Routine/Complete Inspection | No Violations Noted | . With all of the above mentioned changes that have occurred on the site, the Department requires that Cabot have the design engineer review conditions on the ground and submit a new revised site plan reflecting the site changes along with BMP changes that may be required. This inspection does not qualify as a preoperational inspection. A preoperational inspection will be conducted after the Department reviews the updated site plan. |
2266520 | Primary Facility | 2014-04-29 | Preoperation Inspection | No Violations Noted | The Department was on site on 4/29/14 at the Cabot Slocum S. Well Site to conduct a Preoperational Inspection. Well permits that have been issued for this pad are the 1H (115-21666), 3H (115-21667), and the 5H (115-21668). |
2269181 | Primary Facility | 2014-05-07 | Incident- Response to Accident or Event | Violation(s) Noted | On 5/7/14, the Department conducted a site visit of the Cabot Slocum S Pad in response to a reported release of diesel fuel. On 5/6/14 at approximately 10:00 A.M., Steve Watson contacted the Department to report the release of approximately 6 gallons of diesel fuel on the pad. Steve stated that the spill occurred at approximately 9:30 A.M. Later that day, at approximately 5:00P.M., Steve contacted the Department and stated that he was revising the release estimate to at least 30 to 40 gallons. |
2269675 | Primary Facility | 2014-05-12 | Drilling/Alteration | No Violations Noted | |
2272009 | Primary Facility | 2014-04-17 | Routine/Complete Inspection | No Violations Noted | The Department was on site on 4/17/14 at the Cabot Slocum S. Well Site to conduct an inspection. Inspection is a follow-up inspection to evaluate how the pad construction is progressing. Well permits that have been issued for this pad are the 1H (115-21666), 3H (115-21667), and the 5H (115-21668). The tank pad is approximately 95% complete. The perimeter BMP’s are in place for this pad. The top soil stock pile and a timber pile that have been installed above the cut slope of the tank pad have not been red lined onto the site plans. The well pad has been cleared and grubbed. Large pools of standing water are present on the well pad location. The site has still not evolved to the point where a pre-operational inspection would be warranted. This inspection does not qualify as a pre-operational inspection. Will re-inspect in near future |
2272015 | Primary Facility | 2014-04-10 | Routine/Complete Inspection | No Violations Noted | The Department was on site on 4/10/14 at the Cabot Slocum S. Well Site to conduct an inspection. Inspection based on Cabot notification that well spudding of this pad is to occur in the very near future, but that site conditions exist which are impeding construction. Well permits that have been issued for this pad are the 1H (115-21666), 3H (115-21667), and the 5H (115-21668). The tank pad is approximately 90% complete. The perimeter BMP’s are in place for this pad. A top soil stock pile and a timber pile have been installed on above the cut slope of the tank pad. Pointed out to George Bishop, GDS foreman, that these features were not on the E&S plans and that they needed to be red lined onto the site plans. The well pad has been cleared, and is currently being grubbed. This inspection does not qualify as a pre-operational inspection. Will re-inspect in near future |
2272146 | Primary Facility | 2014-05-21 | Administrative/File Review | No Violations Noted | This administrative inspection has been created to document Cabot’s response letter related to violations noted in the 4/29/14 NOV/inspection record # 2266507 and the associated enforcement record # 310543. Attached is a copy of the response letter. |
2273676 | Primary Facility | 2014-05-21 | Follow-up Inspection | No Violations Noted | The Department was on site on 5//14 at the Cabot Slocum S. Well Site to conduct a follow up inspection. Well permits that have been issued for this pad are the 1H (115-21666), 3H (115-21667), and the 5H (115-21668). |
2285941 | Primary Facility | 2014-05-21 | Routine/Complete Inspection | No Violations Noted | H&P Drilling Rig #371 is the active rig on location currently drilling the S Slocum 5H well. The current drilling depth is (4,743.21) feet. Cabot is drilling the lateral section of the well below the intermediate string through the process of water based mud drilling. A white powdery susbstance, was observed spilled to the drilling rig containment. A light tower did not have properly secured containment. The secondary containment berm in the backyard next to the drill cuttings containers was not secured properly. Mr. Wyant contacted rig hands just before the Department left the site to request the white powdery substance spilled to containment be cleaned up immediately and all insecure areas of secondary containment on the location be compleltely secured immediately as well. |
2477061 | Primary Facility | 2016-04-21 | Routine/Complete Inspection | No Violations Noted | |
2484891 | Primary Facility | 2016-05-17 | Routine/Complete Inspection | No Violations Noted | On 5/17/16, the Department conducted an inspection of the COG Slocum, S. Pad located in Jackson Township, Susquehanna County. The inspection was in response to Cabot’s self-reporting of a spill of 12 gallons of antifreeze on the access road of the pad. According to Steve Watson, COG EH&S Specialist at around 7:00 PM, 5/16/16, the previous evening the driver of a low boy who was delivering a piece of machinery noticed that his truck was leaking antifreeze, a line had sprung a leak. J.P. Reilly is the contractor and began the clean-up of the spill. Not sure exactly how much material spilled on the access road as opposed to how much was lost in travel, but after the line was fixed, 12 gallons of antifreeze was added to the reservoir, hence the 12 gallon reporting. Today’s inspection revealed that approximately 3 tons of material has been excavated and placed in a lined roll-off container. According to Jose Fernandez of J.P. Reilly, Resource Environmental had just left, and that they had collected soil sam |
2493194 | Primary Facility | 2016-06-15 | Routine/Complete Inspection | No Violations Noted | |
2531814 | Primary Facility | 2016-10-24 | Routine/Complete Inspection | No Violations Noted | |
2563584 | Primary Facility | 2017-02-21 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 13:45p.m., the cellar was about a quarter full of ice. The (13x9) annulus vent pipe was open and venting into a small plastic tank, the (9x5) annulus vent pipe was open and venting into a small plastic tank. There was 642psi on the production casing. I took a walk around the location and there were no obvious concerns noticed.
I left the site at 14:15p.m. |
2679487 | Primary Facility | 2018-01-08 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The cellar was full of ice and was unable to check for gas. The (13x9) and (9x5) annuli vent pipes were connected together and venting to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2708525 | Primary Facility | 2018-03-21 | Routine/Complete Inspection | No Violations Noted | Today's inspection was conducted as a routine inspection. No E&S issues were identified. No violations noted. |
2779287 | Primary Facility | 2018-09-25 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was water 5' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2844382 | Primary Facility | 2019-02-25 | Routine/Complete Inspection | No Violations Noted | Today's inspection was conducted as a routine inspection. Overall the site appears to have good stabilization. No E&S issues identified. No violations noted. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2269181 | 695359 | 05/07/2014 | 2014-05-07 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | NERO EC&B granted Act 2 ROL on 9/10/14, viols closed. |
2269181 | 695361 | 05/07/2014 | 2014-05-07 | 91.34A - Failure to take all necessary measures to prevent spill. Inadequate diking, potential pollution | Environmental Health & Safety | NERO EC&B granted Act 2 ROL on 9/10/14, viols closed. |
2269181 | 695362 | 05/07/2014 | 2014-05-07 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | NERO EC&B granted Act 2 ROL on 9/10/14, viols closed. |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
695359 | 310846 | NOV - Notice of Violation | Administrative Close Out | 2014-09-10 | |||
695361 | 310846 | NOV - Notice of Violation | Administrative Close Out | 2014-09-10 | |||
695362 | 310846 | NOV - Notice of Violation | Administrative Close Out | 2014-09-10 |
For data sources see[7]