If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-117-21583 | | Well ID: 37-117-21583 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 41.557836, -77.079067 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 21: | Line 21: | ||
| License Status: Active | | License Status: Active | ||
|- | |- | ||
− | | Spud Date: 11 | + | | Spud Date: 2012-11-18 |
|- | |- | ||
− | | Permit Date: | + | | Permit Date: 2012-08-24 |
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
Line 49: | Line 49: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | | 1 | ||
+ | | 2013-06-18 | ||
+ | | 2013-07-30 | ||
+ | | style="text-align: right;" | 6738 | ||
+ | | style="text-align: right;" | 4,770,820.0 | ||
+ | | style="text-align: right;" | 419832 | ||
+ | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="27"| 1 | ||
+ | | rowspan="1"| Plexgel Breaker 10L | ||
+ | | rowspan="1"| Chemplex, L.C. | ||
+ | | rowspan="1"| Breaker | ||
+ | | No Hazardous Ingredients | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00169205 | ||
+ | | style="text-align: right;" | 780 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| EDTA-ACID | ||
+ | | rowspan="2"| Univar | ||
+ | | rowspan="2"| Iron Control | ||
+ | | Ethylenediaminetetraacetic acid | ||
+ | | 60-00-4 | ||
+ | | style="text-align: right;" | 99 | ||
+ | | style="text-align: right;" | 0.000503277 | ||
+ | | style="text-align: right;" | 232 | ||
+ | |- | ||
+ | | Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 1 | ||
+ | | style="text-align: right;" | 0.00000434 | ||
+ | | style="text-align: right;" | 2 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Sand | ||
+ | | rowspan="1"| Operator | ||
+ | | rowspan="1"| Proppant | ||
+ | | Silicon Dioxide | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 13.0448 | ||
+ | | style="text-align: right;" | 6,013,380.0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| 15% Hydrochloric Acid | ||
+ | | rowspan="2"| Reagent | ||
+ | | rowspan="2"| Scale Dissolver | ||
+ | | 36% Hydrochloric Acid | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 15 | ||
+ | | style="text-align: right;" | 0.0743851 | ||
+ | | style="text-align: right;" | 34290 | ||
+ | |- | ||
+ | | Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 85 | ||
+ | | style="text-align: right;" | 0.421514 | ||
+ | | style="text-align: right;" | 194309 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Water | ||
+ | | rowspan="1"| Operator | ||
+ | | rowspan="1"| Base Carrier Fluid | ||
+ | | Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 86.3133 | ||
+ | | style="text-align: right;" | 39,788,700.0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| MSI-7 | ||
+ | | rowspan="1"| National Petrochem | ||
+ | | rowspan="1"| Scale Inhibitor | ||
+ | | Hydrogen Chloride | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00882686 | ||
+ | | style="text-align: right;" | 4069 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| FE-4 | ||
+ | | rowspan="2"| Chemplex, L.C. | ||
+ | | rowspan="2"| Iron Control Additive | ||
+ | | Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 55 | ||
+ | | style="text-align: right;" | 0.00095449 | ||
+ | | style="text-align: right;" | 440 | ||
+ | |- | ||
+ | | Citric Acid Anhydrous | ||
+ | | 77-92-9 | ||
+ | | style="text-align: right;" | 55 | ||
+ | | style="text-align: right;" | 0.00095449 | ||
+ | | style="text-align: right;" | 440 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| FR900 | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Friction Reducer | ||
+ | | Proprietary | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.0790752 | ||
+ | | style="text-align: right;" | 36452 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="4"| Petro-Flo | ||
+ | | rowspan="4"| Bio-Cide International, Inc | ||
+ | | rowspan="4"| Biocide | ||
+ | | Sodium Chloride | ||
+ | | 7647-14-5 | ||
+ | | style="text-align: right;" | 1 | ||
+ | | style="text-align: right;" | 0.000141004 | ||
+ | | style="text-align: right;" | 65 | ||
+ | |- | ||
+ | | Sodium Carbonate | ||
+ | | 497-19-8 | ||
+ | | style="text-align: right;" | 2 | ||
+ | | style="text-align: right;" | 0.000282008 | ||
+ | | style="text-align: right;" | 130 | ||
+ | |- | ||
+ | | Sodium Chlorite | ||
+ | | 7758-19-2 | ||
+ | | style="text-align: right;" | 8.35 | ||
+ | | style="text-align: right;" | 0.00117576 | ||
+ | | style="text-align: right;" | 542 | ||
+ | |- | ||
+ | | Sodium Hydroxide | ||
+ | | 1310-73-2 | ||
+ | | style="text-align: right;" | 1 | ||
+ | | style="text-align: right;" | 0.000141004 | ||
+ | | style="text-align: right;" | 65 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="9"| I-22 | ||
+ | | rowspan="9"| Nalco | ||
+ | | rowspan="9"| Corrosion Inhibitor | ||
+ | | Methanol | ||
+ | | 67-56-1 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00008894 | ||
+ | | style="text-align: right;" | 41 | ||
+ | |- | ||
+ | | Cyclic alkanes | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00008894 | ||
+ | | style="text-align: right;" | 41 | ||
+ | |- | ||
+ | | Quaternary ammonium compound | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00008894 | ||
+ | | style="text-align: right;" | 41 | ||
+ | |- | ||
+ | | Quaternary ammonium compound | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.000531477 | ||
+ | | style="text-align: right;" | 245 | ||
+ | |- | ||
+ | | Isopropanol | ||
+ | | 67-63-0 | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.000177882 | ||
+ | | style="text-align: right;" | 82 | ||
+ | |- | ||
+ | | 2-Mercaptoethyl Alcohol | ||
+ | | 60-24-2 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00008894 | ||
+ | | style="text-align: right;" | 41 | ||
+ | |- | ||
+ | | Oxyalkylated Fatty Acid Derivative | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.000531477 | ||
+ | | style="text-align: right;" | 245 | ||
+ | |- | ||
+ | | Formic Acid | ||
+ | | 64-18-6 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.00106512 | ||
+ | | style="text-align: right;" | 491 | ||
+ | |- | ||
+ | | Aromatic aldehyde | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.000531477 | ||
+ | | style="text-align: right;" | 245 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Plexgel 907 | ||
+ | | rowspan="1"| Chemplex, L.C. | ||
+ | | rowspan="1"| Gellant | ||
+ | | Guar Gum | ||
+ | | 9000-30-0 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.0188165 | ||
+ | | style="text-align: right;" | 8674 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| Bio-Clear 5000 | ||
+ | | rowspan="2"| Clearwater International LLC | ||
+ | | rowspan="2"| Biocide | ||
+ | | Proprietary | ||
+ | | Proprietart | ||
+ | | style="text-align: right;" | 95 | ||
+ | | style="text-align: right;" | 0.0184867 | ||
+ | | style="text-align: right;" | 8522 | ||
+ | |- | ||
+ | | 2,2-dibromo-3-nitril oprop ionam ide | ||
+ | | 10222-01-2 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.000974014 | ||
+ | | style="text-align: right;" | 449 | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =FracFocus Fracking Chemicals Database | ||
+ | | date = 2019-04-02 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-06-19 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 147: | Line 394: | ||
!scope="col" | Waste Facility ID | !scope="col" | Waste Facility ID | ||
|- | |- | ||
− | | 2012- | + | | 2012-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 1,029.24 Tons | | style="text-align: right;" | 1,029.24 Tons | ||
Line 153: | Line 400: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2012- | + | | 2012-S02 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 12.00 Bbl | | style="text-align: right;" | 12.00 Bbl | ||
Line 159: | Line 406: | ||
| WMGR123 | | WMGR123 | ||
|- | |- | ||
− | | 2012- | + | | 2012-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 87.62 Bbl | | style="text-align: right;" | 87.62 Bbl | ||
Line 165: | Line 412: | ||
| WMGR123 | | WMGR123 | ||
|- | |- | ||
− | | 2012- | + | | 2012-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 40.00 Bbl | | style="text-align: right;" | 40.00 Bbl | ||
Line 171: | Line 418: | ||
| WMGR123NC006 | | WMGR123NC006 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S01 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 613.37 Tons | | style="text-align: right;" | 613.37 Tons | ||
Line 177: | Line 424: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S01 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 238.90 Bbl | | style="text-align: right;" | 238.90 Bbl | ||
Line 183: | Line 430: | ||
| WMGR123 | | WMGR123 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S01 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 65.60 Bbl | | style="text-align: right;" | 65.60 Bbl | ||
Line 189: | Line 436: | ||
| WMGR123NC006 | | WMGR123NC006 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S01 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 617.02 Bbl | | style="text-align: right;" | 617.02 Bbl | ||
Line 195: | Line 442: | ||
| | | | ||
|- | |- | ||
− | | 2013- | + | | 2013-S01 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 409.55 Bbl | | style="text-align: right;" | 409.55 Bbl | ||
Line 201: | Line 448: | ||
| | | | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 5.43 Tons | | style="text-align: right;" | 5.43 Tons | ||
Line 207: | Line 454: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 52.50 Bbl | | style="text-align: right;" | 52.50 Bbl | ||
Line 213: | Line 460: | ||
| WMGR119 | | WMGR119 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 233.86 Bbl | | style="text-align: right;" | 233.86 Bbl | ||
Line 219: | Line 466: | ||
| WMGR123 | | WMGR123 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 6.98 Bbl | | style="text-align: right;" | 6.98 Bbl | ||
Line 225: | Line 472: | ||
| 7-3115-00193 | | 7-3115-00193 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 5,176.18 Bbl | | style="text-align: right;" | 5,176.18 Bbl | ||
Line 231: | Line 478: | ||
| | | | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 31.75 Bbl | | style="text-align: right;" | 31.75 Bbl | ||
Line 237: | Line 484: | ||
| WMGR119 | | WMGR119 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 165.86 Bbl | | style="text-align: right;" | 165.86 Bbl | ||
Line 243: | Line 490: | ||
| WMGR123 | | WMGR123 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 4,698.55 Bbl | | style="text-align: right;" | 4,698.55 Bbl | ||
Line 249: | Line 496: | ||
| | | | ||
|- | |- | ||
− | | 2014- | + | | 2014-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 6,288.94 Bbl | | style="text-align: right;" | 6,288.94 Bbl | ||
Line 255: | Line 502: | ||
| | | | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 0.02 Tons | | style="text-align: right;" | 0.02 Tons | ||
Line 261: | Line 508: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 51.86 Bbl | | style="text-align: right;" | 51.86 Bbl | ||
Line 267: | Line 514: | ||
| WMGR123 | | WMGR123 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 214.26 Bbl | | style="text-align: right;" | 214.26 Bbl | ||
Line 273: | Line 520: | ||
| | | | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 275.05 Bbl | | style="text-align: right;" | 275.05 Bbl | ||
Line 279: | Line 526: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 1,516.79 Bbl | | style="text-align: right;" | 1,516.79 Bbl | ||
Line 285: | Line 532: | ||
| | | | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 74.84 Bbl | | style="text-align: right;" | 74.84 Bbl | ||
Line 291: | Line 538: | ||
| | | | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 183.37 Bbl | | style="text-align: right;" | 183.37 Bbl | ||
Line 297: | Line 544: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 1,029.91 Bbl | | style="text-align: right;" | 1,029.91 Bbl | ||
Line 303: | Line 550: | ||
| | | | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 30.23 Bbl | | style="text-align: right;" | 30.23 Bbl | ||
Line 309: | Line 556: | ||
| WMGR123 | | WMGR123 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 500.93 Bbl | | style="text-align: right;" | 500.93 Bbl | ||
Line 315: | Line 562: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 444.69 Bbl | | style="text-align: right;" | 444.69 Bbl | ||
Line 321: | Line 568: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-S02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 1,002.02 Bbl | | style="text-align: right;" | 1,002.02 Bbl | ||
Line 327: | Line 574: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2016- | + | | 2016-S02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 1,596.26 Bbl | | style="text-align: right;" | 1,596.26 Bbl | ||
Line 333: | Line 580: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-S02 |
| Synthetic Liner Materials (in Tons) RWC 806 | | Synthetic Liner Materials (in Tons) RWC 806 | ||
| style="text-align: right;" | 0.26 Tons | | style="text-align: right;" | 0.26 Tons | ||
Line 339: | Line 586: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 33.33 Bbl | | style="text-align: right;" | 33.33 Bbl | ||
Line 345: | Line 592: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 33.33 Bbl | | style="text-align: right;" | 33.33 Bbl | ||
Line 351: | Line 598: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 133.33 Bbl | | style="text-align: right;" | 133.33 Bbl | ||
Line 357: | Line 604: | ||
| WMGR123NC022 | | WMGR123NC022 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 33.33 Bbl | | style="text-align: right;" | 33.33 Bbl | ||
Line 363: | Line 610: | ||
| WMGR123NC022 | | WMGR123NC022 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 133.33 Bbl | | style="text-align: right;" | 133.33 Bbl | ||
Line 369: | Line 616: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 233.33 Bbl | | style="text-align: right;" | 233.33 Bbl | ||
Line 375: | Line 622: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M04 |
| Waste Water Treatment Sludge (in Tons) RWC 804 | | Waste Water Treatment Sludge (in Tons) RWC 804 | ||
| style="text-align: right;" | 2.06 Tons | | style="text-align: right;" | 2.06 Tons | ||
Line 381: | Line 628: | ||
| WMGR123 | | WMGR123 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 143.00 Bbl | | style="text-align: right;" | 143.00 Bbl | ||
Line 387: | Line 634: | ||
| WMGR123NC022 | | WMGR123NC022 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 233.33 Bbl | | style="text-align: right;" | 233.33 Bbl | ||
Line 393: | Line 640: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 66.67 Bbl | | style="text-align: right;" | 66.67 Bbl | ||
Line 399: | Line 646: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 54.20 Bbl | | style="text-align: right;" | 54.20 Bbl | ||
Line 405: | Line 652: | ||
| WMGR123NC010 | | WMGR123NC010 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 133.33 Bbl | | style="text-align: right;" | 133.33 Bbl | ||
Line 411: | Line 658: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 35.03 Bbl | | style="text-align: right;" | 35.03 Bbl | ||
Line 417: | Line 664: | ||
| WMGR123NC010 | | WMGR123NC010 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 16.00 Bbl | | style="text-align: right;" | 16.00 Bbl | ||
Line 423: | Line 670: | ||
| WMGR123NC022 | | WMGR123NC022 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 116.67 Bbl | | style="text-align: right;" | 116.67 Bbl | ||
Line 429: | Line 676: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 158.00 Bbl | | style="text-align: right;" | 158.00 Bbl | ||
Line 435: | Line 682: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M12 |
| Waste Water Treatment Sludge (in Tons) RWC 804 | | Waste Water Treatment Sludge (in Tons) RWC 804 | ||
| style="text-align: right;" | 1.33 Tons | | style="text-align: right;" | 1.33 Tons | ||
Line 441: | Line 688: | ||
| PA-0678 | | PA-0678 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 140.92 Bbl | | style="text-align: right;" | 140.92 Bbl | ||
Line 447: | Line 694: | ||
| WMGR123NC010 | | WMGR123NC010 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 146.67 Bbl | | style="text-align: right;" | 146.67 Bbl | ||
Line 453: | Line 700: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 1,198.00 Bbl | | style="text-align: right;" | 1,198.00 Bbl | ||
Line 459: | Line 706: | ||
| WMGR123 | | WMGR123 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M06 |
| Synthetic Liner Materials (in Tons) RWC 806 | | Synthetic Liner Materials (in Tons) RWC 806 | ||
| style="text-align: right;" | 2.20 Tons | | style="text-align: right;" | 2.20 Tons | ||
Line 465: | Line 712: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 83.40 Bbl | | style="text-align: right;" | 83.40 Bbl | ||
Line 471: | Line 718: | ||
| WMGR123NC010 | | WMGR123NC010 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 130.00 Bbl | | style="text-align: right;" | 130.00 Bbl | ||
Line 477: | Line 724: | ||
| WMGR123 | | WMGR123 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 841.12 Bbl | | style="text-align: right;" | 841.12 Bbl | ||
Line 483: | Line 730: | ||
| WMGR123NC010 | | WMGR123NC010 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 154.00 Bbl | | style="text-align: right;" | 154.00 Bbl | ||
Line 489: | Line 736: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Produced Fluid (in Tons) RWC 802 | | Produced Fluid (in Tons) RWC 802 | ||
| style="text-align: right;" | 14.06 Tons | | style="text-align: right;" | 14.06 Tons | ||
Line 495: | Line 742: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Synthetic Liner Materials (in Tons) RWC 806 | | Synthetic Liner Materials (in Tons) RWC 806 | ||
| style="text-align: right;" | 0.95 Tons | | style="text-align: right;" | 0.95 Tons | ||
Line 501: | Line 748: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 50.00 Bbl | | style="text-align: right;" | 50.00 Bbl | ||
Line 507: | Line 754: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M08 |
| Synthetic Liner Materials (in Tons) RWC 806 | | Synthetic Liner Materials (in Tons) RWC 806 | ||
| style="text-align: right;" | 0.77 Tons | | style="text-align: right;" | 0.77 Tons | ||
Line 513: | Line 760: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M09 |
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 63.00 Bbl | | style="text-align: right;" | 63.00 Bbl | ||
Line 519: | Line 766: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 292.00 Bbl | | style="text-align: right;" | 292.00 Bbl | ||
Line 525: | Line 772: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M09 |
| Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 | | Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 | ||
| style="text-align: right;" | 31.05 Tons | | style="text-align: right;" | 31.05 Tons | ||
Line 531: | Line 778: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M09 |
| Synthetic Liner Materials (in Tons) RWC 806 | | Synthetic Liner Materials (in Tons) RWC 806 | ||
| style="text-align: right;" | 2.81 Tons | | style="text-align: right;" | 2.81 Tons | ||
Line 537: | Line 784: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 126.00 Bbl | | style="text-align: right;" | 126.00 Bbl | ||
Line 543: | Line 790: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 400.00 Bbl | | style="text-align: right;" | 400.00 Bbl | ||
Line 549: | Line 796: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M11 |
| Synthetic Liner Materials (in Tons) RWC 806 | | Synthetic Liner Materials (in Tons) RWC 806 | ||
| style="text-align: right;" | 0.99 Tons | | style="text-align: right;" | 0.99 Tons | ||
Line 555: | Line 802: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M12 |
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 64.80 Bbl | | style="text-align: right;" | 64.80 Bbl | ||
Line 561: | Line 808: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 335.00 Bbl | | style="text-align: right;" | 335.00 Bbl | ||
Line 567: | Line 814: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M12 |
| Synthetic Liner Materials (in Tons) RWC 806 | | Synthetic Liner Materials (in Tons) RWC 806 | ||
| style="text-align: right;" | 0.54 Tons | | style="text-align: right;" | 0.54 Tons | ||
Line 573: | Line 820: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2019- | + | | 2019-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 497.80 Bbl | | style="text-align: right;" | 497.80 Bbl | ||
Line 579: | Line 826: | ||
| | | | ||
|- | |- | ||
− | | 2019- | + | | 2019-M02 |
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 227.33 Bbl | | style="text-align: right;" | 227.33 Bbl | ||
Line 585: | Line 832: | ||
| | | | ||
|- | |- | ||
− | | 2019- | + | | 2019-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 52.00 Bbl | | style="text-align: right;" | 52.00 Bbl | ||
Line 591: | Line 838: | ||
| | | | ||
|- | |- | ||
− | | 2019- | + | | 2019-M02 |
| Synthetic Liner Materials (in Tons) RWC 806 | | Synthetic Liner Materials (in Tons) RWC 806 | ||
| style="text-align: right;" | 6.88 Tons | | style="text-align: right;" | 6.88 Tons | ||
Line 597: | Line 844: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2019- | + | | 2019-M03 |
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 231.60 Bbl | | style="text-align: right;" | 231.60 Bbl | ||
Line 603: | Line 850: | ||
| | | | ||
|- | |- | ||
− | | 2019- | + | | 2019-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 154.40 Bbl | | style="text-align: right;" | 154.40 Bbl | ||
Line 609: | Line 856: | ||
| | | | ||
|- | |- | ||
− | | 2019- | + | | 2019-M03 |
| Synthetic Liner Materials (in Tons) RWC 806 | | Synthetic Liner Materials (in Tons) RWC 806 | ||
| style="text-align: right;" | 3.71 Tons | | style="text-align: right;" | 3.71 Tons | ||
Line 634: | Line 881: | ||
| 2118705 | | 2118705 | ||
| Primary Facility | | Primary Facility | ||
− | | 11 | + | | 2012-11-19 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| Violation(s) Noted | | Violation(s) Noted | ||
Line 641: | Line 888: | ||
| 2128609 | | 2128609 | ||
| Primary Facility | | Primary Facility | ||
− | | 01 | + | | 2013-01-02 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 648: | Line 895: | ||
| 2182247 | | 2182247 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2013-07-10 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 655: | Line 902: | ||
| 2194920 | | 2194920 | ||
| Primary Facility | | Primary Facility | ||
− | | 08 | + | | 2013-08-07 |
| Incident- Response to Accident or Event | | Incident- Response to Accident or Event | ||
| No Violations Noted | | No Violations Noted | ||
Line 662: | Line 909: | ||
| 2207795 | | 2207795 | ||
| Primary Facility | | Primary Facility | ||
− | | 09 | + | | 2013-09-25 |
| Follow-up Inspection | | Follow-up Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 669: | Line 916: | ||
| 2215563 | | 2215563 | ||
| Primary Facility | | Primary Facility | ||
− | | 10 | + | | 2013-10-22 |
| Follow-up Inspection | | Follow-up Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 676: | Line 923: | ||
| 2230612 | | 2230612 | ||
| Primary Facility | | Primary Facility | ||
− | | 12 | + | | 2013-12-18 |
| Compliance Evaluation | | Compliance Evaluation | ||
| No Violations Noted | | No Violations Noted | ||
Line 683: | Line 930: | ||
| 2265776 | | 2265776 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2014-04-23 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 690: | Line 937: | ||
| 2361296 | | 2361296 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2015-04-15 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 770: | Line 1,017: | ||
| 654842 | | 654842 | ||
| 11/19/2012 | | 11/19/2012 | ||
− | | | + | | 2012-11-19 |
| 201F - Failure to notify DEP, landowner, political subdivision, or coal owner 24 hrs prior to commencement of drilling | | 201F - Failure to notify DEP, landowner, political subdivision, or coal owner 24 hrs prior to commencement of drilling | ||
| Administrative | | Administrative | ||
Line 778: | Line 1,025: | ||
| 654843 | | 654843 | ||
| 11/19/2012 | | 11/19/2012 | ||
− | | | + | | 2012-11-19 |
| 201E - Failure to comply with terms and conditions of permit | | 201E - Failure to comply with terms and conditions of permit | ||
| Environmental Health & Safety | | Environmental Health & Safety | ||
Line 802: | Line 1,049: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==References== | ==References== | ||
<references/> | <references/> |
Well ID: 37-117-21583 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.557836,"lon":-77.079067,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Tioga | |
Municipality: Liberty Township | |
Operator Name: ROCKDALE MARCELLUS LLC | |
Well Pad ID: 145419 | |
Farm/Lease Name: LYNN D 719W 3H | |
License Status: Active | |
Spud Date: 2012-11-18 | |
Permit Date: 2012-08-24 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.557836 | |
Longitude: -77.079067 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-06-18 | 2013-07-30 | 6738 | 4,770,820.0 | 419832 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Plexgel Breaker 10L | Chemplex, L.C. | Breaker | No Hazardous Ingredients | Proprietary | 100 | 0.00169205 | 780 |
EDTA-ACID | Univar | Iron Control | Ethylenediaminetetraacetic acid | 60-00-4 | 99 | 0.000503277 | 232 | |
Water | 7732-18-5 | 1 | 0.00000434 | 2 | ||||
Sand | Operator | Proppant | Silicon Dioxide | 14808-60-7 | 100 | 13.0448 | 6,013,380.0 | |
15% Hydrochloric Acid | Reagent | Scale Dissolver | 36% Hydrochloric Acid | 7647-01-0 | 15 | 0.0743851 | 34290 | |
Water | 7732-18-5 | 85 | 0.421514 | 194309 | ||||
Water | Operator | Base Carrier Fluid | Water | 7732-18-5 | 100 | 86.3133 | 39,788,700.0 | |
MSI-7 | National Petrochem | Scale Inhibitor | Hydrogen Chloride | 7647-01-0 | 100 | 0.00882686 | 4069 | |
FE-4 | Chemplex, L.C. | Iron Control Additive | Water | 7732-18-5 | 55 | 0.00095449 | 440 | |
Citric Acid Anhydrous | 77-92-9 | 55 | 0.00095449 | 440 | ||||
FR900 | Nalco | Friction Reducer | Proprietary | Proprietary | 100 | 0.0790752 | 36452 | |
Petro-Flo | Bio-Cide International, Inc | Biocide | Sodium Chloride | 7647-14-5 | 1 | 0.000141004 | 65 | |
Sodium Carbonate | 497-19-8 | 2 | 0.000282008 | 130 | ||||
Sodium Chlorite | 7758-19-2 | 8.35 | 0.00117576 | 542 | ||||
Sodium Hydroxide | 1310-73-2 | 1 | 0.000141004 | 65 | ||||
I-22 | Nalco | Corrosion Inhibitor | Methanol | 67-56-1 | 5 | 0.00008894 | 41 | |
Cyclic alkanes | Proprietary | 5 | 0.00008894 | 41 | ||||
Quaternary ammonium compound | Proprietary | 5 | 0.00008894 | 41 | ||||
Quaternary ammonium compound | Proprietary | 30 | 0.000531477 | 245 | ||||
Isopropanol | 67-63-0 | 10 | 0.000177882 | 82 | ||||
2-Mercaptoethyl Alcohol | 60-24-2 | 5 | 0.00008894 | 41 | ||||
Oxyalkylated Fatty Acid Derivative | Proprietary | 30 | 0.000531477 | 245 | ||||
Formic Acid | 64-18-6 | 60 | 0.00106512 | 491 | ||||
Aromatic aldehyde | Proprietary | 30 | 0.000531477 | 245 | ||||
Plexgel 907 | Chemplex, L.C. | Gellant | Guar Gum | 9000-30-0 | 100 | 0.0188165 | 8674 | |
Bio-Clear 5000 | Clearwater International LLC | Biocide | Proprietary | Proprietart | 95 | 0.0184867 | 8522 | |
2,2-dibromo-3-nitril oprop ionam ide | 10222-01-2 | 5 | 0.000974014 | 449 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | SWEPI LP | 552,695.73 | 118 | 0.00 | 0 | 0.00 | 0 |
2014 | SWEPI LP | 1,025,494.72 | 363 | 0.00 | 0 | 0.00 | 0 |
2015 | SWEPI LP | 699,845.28 | 358 | 0.00 | 0 | 0.00 | 0 |
2016 | SWEPI LP | 547,857.99 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | SWEPI LP | 455,795.80 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | ROCKDALE MARCELLUS LLC | 334,408.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | ROCKDALE MARCELLUS LLC | 55,806.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2012-S02 | Drill Cuttings (in Tons) | 1,029.24 Tons | LANDFILL | 301358 |
2012-S02 | Drilling Fluid Waste (in Barrels) | 12.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2012-S02 | Fracing Fluid Waste (in Barrels) | 87.62 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2012-S02 | Produced Fluid (in Barrels) | 40.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC006 |
2013-S01 | Drill Cuttings (in Tons) | 613.37 Tons | LANDFILL | 301358 |
2013-S01 | Drilling Fluid Waste (in Barrels) | 238.90 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013-S01 | Drilling Fluid Waste (in Barrels) | 65.60 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC006 |
2013-S01 | Drilling Fluid Waste (in Barrels) | 617.02 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S01 | Fracing Fluid Waste (in Barrels) | 409.55 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S02 | Drill Cuttings (in Tons) | 5.43 Tons | LANDFILL | 301358 |
2013-S02 | Fracing Fluid Waste (in Barrels) | 52.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2013-S02 | Fracing Fluid Waste (in Barrels) | 233.86 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013-S02 | Fracing Fluid Waste (in Barrels) | 6.98 Bbl | RESIDUAL WASTE TRANSFER FACILITY | 7-3115-00193 |
2013-S02 | Fracing Fluid Waste (in Barrels) | 5,176.18 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S02 | Produced Fluid (in Barrels) | 31.75 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2013-S02 | Produced Fluid (in Barrels) | 165.86 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013-S02 | Produced Fluid (in Barrels) | 4,698.55 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S01 | Produced Fluid (in Barrels) | 6,288.94 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S02 | Drill Cuttings (in Tons) | 0.02 Tons | LANDFILL | 301358 |
2014-S02 | Fracing Fluid Waste (in Barrels) | 51.86 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2014-S02 | Fracing Fluid Waste (in Barrels) | 214.26 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S02 | Produced Fluid (in Barrels) | 275.05 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2014-S02 | Produced Fluid (in Barrels) | 1,516.79 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S01 | Fracing Fluid Waste (in Barrels) | 74.84 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S01 | Produced Fluid (in Barrels) | 183.37 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015-S01 | Produced Fluid (in Barrels) | 1,029.91 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S02 | Produced Fluid (in Barrels) | 30.23 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015-S02 | Produced Fluid (in Barrels) | 500.93 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015-S02 | Produced Fluid (in Barrels) | 444.69 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 1,002.02 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 1,596.26 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S02 | Synthetic Liner Materials (in Tons) RWC 806 | 0.26 Tons | LANDFILL | 301358 |
2017-M01 | Produced Fluid (in Barrels) RWC 802 | 33.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017-M01 | Produced Fluid (in Barrels) RWC 802 | 33.33 Bbl | REUSE (AT WELL PAD) | |
2017-M02 | Produced Fluid (in Barrels) RWC 802 | 133.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 33.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 133.33 Bbl | REUSE (AT WELL PAD) | |
2017-M04 | Produced Fluid (in Barrels) RWC 802 | 233.33 Bbl | REUSE (AT WELL PAD) | |
2017-M04 | Waste Water Treatment Sludge (in Tons) RWC 804 | 2.06 Tons | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017-M05 | Produced Fluid (in Barrels) RWC 802 | 143.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 233.33 Bbl | REUSE (AT WELL PAD) | |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 66.67 Bbl | REUSE (AT WELL PAD) | |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 54.20 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 133.33 Bbl | REUSE (AT WELL PAD) | |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 35.03 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 16.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 116.67 Bbl | REUSE (AT WELL PAD) | |
2017-M10 | Produced Fluid (in Barrels) RWC 802 | 158.00 Bbl | REUSE (AT WELL PAD) | |
2017-M12 | Waste Water Treatment Sludge (in Tons) RWC 804 | 1.33 Tons | STORAGE PENDING DISPOSAL OR REUSE | PA-0678 |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 140.92 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 146.67 Bbl | REUSE (AT WELL PAD) | |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 1,198.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018-M06 | Synthetic Liner Materials (in Tons) RWC 806 | 2.20 Tons | LANDFILL | 301358 |
2018-M07 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 83.40 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 130.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 841.12 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 154.00 Bbl | REUSE (AT WELL PAD) | |
2018-M07 | Produced Fluid (in Tons) RWC 802 | 14.06 Tons | LANDFILL | 301358 |
2018-M07 | Synthetic Liner Materials (in Tons) RWC 806 | 0.95 Tons | LANDFILL | 301358 |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 50.00 Bbl | REUSE (AT WELL PAD) | |
2018-M08 | Synthetic Liner Materials (in Tons) RWC 806 | 0.77 Tons | LANDFILL | 301358 |
2018-M09 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 63.00 Bbl | REUSE (AT WELL PAD) | |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 292.00 Bbl | REUSE (AT WELL PAD) | |
2018-M09 | Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 | 31.05 Tons | LANDFILL | 301358 |
2018-M09 | Synthetic Liner Materials (in Tons) RWC 806 | 2.81 Tons | LANDFILL | 301358 |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 126.00 Bbl | REUSE (AT WELL PAD) | |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 400.00 Bbl | REUSE (AT WELL PAD) | |
2018-M11 | Synthetic Liner Materials (in Tons) RWC 806 | 0.99 Tons | LANDFILL | 301358 |
2018-M12 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 64.80 Bbl | REUSE (AT WELL PAD) | |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 335.00 Bbl | REUSE (AT WELL PAD) | |
2018-M12 | Synthetic Liner Materials (in Tons) RWC 806 | 0.54 Tons | LANDFILL | 301358 |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 497.80 Bbl | REUSE (AT WELL PAD) | |
2019-M02 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 227.33 Bbl | REUSE (AT WELL PAD) | |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 52.00 Bbl | REUSE (AT WELL PAD) | |
2019-M02 | Synthetic Liner Materials (in Tons) RWC 806 | 6.88 Tons | LANDFILL | 301358 |
2019-M03 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 231.60 Bbl | REUSE (AT WELL PAD) | |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 154.40 Bbl | REUSE (AT WELL PAD) | |
2019-M03 | Synthetic Liner Materials (in Tons) RWC 806 | 3.71 Tons | LANDFILL | 301358 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2118705 | Primary Facility | 2012-11-19 | Routine/Complete Inspection | Violation(s) Noted | the 1-6H wells on the pad were spud without electronic notification or pre-operational inspection |
2128609 | Primary Facility | 2013-01-02 | Routine/Complete Inspection | No Violations Noted | |
2182247 | Primary Facility | 2013-07-10 | Routine/Complete Inspection | No Violations Noted | |
2194920 | Primary Facility | 2013-08-07 | Incident- Response to Accident or Event | No Violations Noted | 5 bbl spill on 8/3/13. Violations cited against the 1H permit. TLT |
2207795 | Primary Facility | 2013-09-25 | Follow-up Inspection | No Violations Noted | |
2215563 | Primary Facility | 2013-10-22 | Follow-up Inspection | No Violations Noted | |
2230612 | Primary Facility | 2013-12-18 | Compliance Evaluation | No Violations Noted | |
2265776 | Primary Facility | 2014-04-23 | Routine/Complete Inspection | No Violations Noted | |
2361296 | Primary Facility | 2015-04-15 | Routine/Complete Inspection | No Violations Noted | Temporary stabilization generally >70% cover. Temp BMPs in place. One filter sock near access road entrance needs repair. Elevated conductivity in sediment/infiltration basin on north side of pad (2.3 mS/cm). Several stained spots on pad surface. |
2496423 | Primary Facility | 2016-06-27 | Routine/Complete Inspection | No Violations Noted | Routine inspection to assess overall site conditions. No SWEPI representatives were present.
Vegetative cover on site is greater than 70%. No evidence of accelerated erosion or sedimentation was observed. Per § 3216(c) of the 2012 Oil and Gas Act (58 Pa.C.S. §3216(c)), site restoration is required to occur within 9 months of completion of well drilling, unless an extension request is filed with, and approved by the Department. A restoration extension request was approved by the Department on 04/09/2015, which extends the restoration deadline until 04/09/2017. No violations were cited during this inspection. |
2543586 | Primary Facility | 2016-12-08 | Routine/Complete Inspection | No Violations Noted | Routine inspection to assess overall site conditions. No SWEPI representatives were present.
Vegetative cover on site is greater than 70%. Temporary erosion and sediment control BMPs have been removed. No evidence of accelerated erosion or sedimentation was observed. A restoration extension request was approved by the Department on 04/09/2015, which extends the restoration deadline until 04/09/2017. The Erosion and Sediment Control General Permit for the site expires on 05/01/2017. No violations were cited during this inspection. |
2717063 | Primary Facility | 2018-04-11 | Routine/Complete Inspection | No Violations Noted | Weather was 33° and sunny at time of inspection. Thrre were no Rockdale representatives on location at time of inspection. Well had one analog pressure gauge attached above the swab valve. The pressure gauge attached above the swab valve read approximately 250 psi at time of inspection. There were three annulus vents plumbed to surface. Unable to determine the origin point of each individual annulus vent due to the cellar being full of gravel. Annulus vents were 2", 1 1/2" and 1". The 2" vent had 30% methane by volume detected. No combustible gas was detected on the other 2 vents at time of inspection. No violations noted at time of inspection. |
2732087 | Primary Facility | 2018-05-14 | Routine/Complete Inspection | No Violations Noted | At the time of the inspection; containment, tanks, and equipment were installed in anticipation of completions activities on several of the wells onsite. PCSM/Site Restoration plans have been partially implemented. Infiltration basins have been installed but the impervious gravel pad surface has not been reduced as depicted in the approved plans. A 2-year extension on site restoration was approved on 10/20/2017. The Department recommends the PCSM/Site Restoration plans be implemented as permitted by 10/20/2019 or modified to account for the impervious pad surface. |
2738679 | Primary Facility | 2018-06-05 | Routine/Complete Inspection | No Violations Noted | I met Luke Chesner and Levi Lee of Rockdale when I arrived. Coil tubing rig on location drilling out plugs on the 6H prior to moving to the 4H. I noted two areas on the pad that were wet and muddy, one between the coil tubing rig and a pump truck (approximately 5-8 gallons of free water and 30' x 40'), and one between two Baker tank batteries (approximately 10-15 gallons of free water and 30' x 50'). Conductance reading in the former was 9.22 mS/cm, and was over the limit of my meter (19.99mS/cm) in the latter. I pointed both of these areas out to Luke and Levi, and took a grab sample (ID#0939066) from a puddle in the area between the Baker tank batteries. Luke and Levi had a vac truck working in the area between the pump truck and the coil tubing rig almost immediately, and I recommended that they vac the area between the Baker tank batteries and start to remove the affected soil ASAP. The elevated conductance in these areas is an indication of a potential release of produced water or flowback to the |
2761140 | Primary Facility | 2018-08-06 | Incident- Response to Accident or Event | No Violations Noted | I arrived on site in response to a spill notification from Rockdale called in at 09:45 on 8/4/18. Regina Logue of Rockdale reported that approximately 2 barrels of potentially contaminated rainwater was released to the pad due to a failed containment, and stated that the release was near the aboveground storage tank. The only person present at the pad when I arrived was Brady Bryington of Principal Enterprise. He pointed out the area of the release, and when I inquired informed me that the AST contained fresh water. I screened the release area, which was at the corner of an upright tank containment, with my soil conductance meter; most readings were in the range of .10-2.2 mS/cm, and the readings dropped dramatically when I pushed the meter 1/4" into the soil. I did locate a spot that seemed to be somewhat removed from the spill area near the center of the upright tank containment that was over limit on my soil meter (greater than 4.0 mS/cm). Towards the rock-lined ditch from the release area, soil con |
2791184 | Primary Facility | 2018-10-17 | Routine/Partial Inspection | No Violations Noted | No activity on site. Due to time constraints, only a partial inspection was performed. Site had a large puddle (50-100 gallons) present in the area of the release documented in the 6/5/18 inspection. Soil conductance readings in this area ranged from .20-.53 mS/cm. Violations remain outstanding. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2118705 | 654842 | 11/19/2012 | 2012-11-19 | 201F - Failure to notify DEP, landowner, political subdivision, or coal owner 24 hrs prior to commencement of drilling | Administrative | the 1-6H wells on the pad were spud without electronic notification or pre-operational inspection |
2118705 | 654843 | 11/19/2012 | 2012-11-19 | 201E - Failure to comply with terms and conditions of permit | Environmental Health & Safety | the 1-6H wells on the pad were spud without electronic notification or pre-operational inspection |
For data sources see[7]