X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-117-21792"

m
 
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-117-21792
 
| Well ID: 37-117-21792
| style="height=100%; align=center" rowspan="14" | {{#display_map: 41.943136, -77.356242 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.943136, -77.356242 | width=100% | height=100% }}
 
|-
 
|-
 
| Country: United States
 
| Country: United States
Line 21: Line 21:
 
| License Status: Active
 
| License Status: Active
 
|-
 
|-
| Spud Date: 10/13/2015
+
| Spud Date: 2015-10-13
 
|-
 
|-
| Permit Date: 8/6/2015
+
| Permit Date: 2015-08-06
 
|-
 
|-
 
| Unconventional Well: Y
 
| Unconventional Well: Y
Line 49: Line 49:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 2016-01-12
 +
| 2016-01-23
 +
| style="text-align: right;" | 10824
 +
| style="text-align: right;" | 11,582,600.0
 +
| style="text-align: right;" | 0
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="24"| 1
 +
| rowspan="6"| WFRA-2100
 +
| rowspan="6"| U.S. Well Services
 +
| rowspan="6"| Friction Reducer
 +
| Alcohol Ethoxylate
 +
| 68551-12-2
 +
| style="text-align: right;" | 2
 +
| style="text-align: right;" | 0.00129
 +
| style="text-align: right;" | 174.86
 +
|-
 +
| Alkanolamide
 +
| 93-83-4
 +
| style="text-align: right;" | 2
 +
| style="text-align: right;" | 0.00129
 +
| style="text-align: right;" | 174.86
 +
|-
 +
| Hydrotreated Petroleum Distillates
 +
| 64742-47-8
 +
| style="text-align: right;" | 20
 +
| style="text-align: right;" | 0.01041
 +
| style="text-align: right;" | 1748.6
 +
|-
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 50
 +
| style="text-align: right;" | 0.03213
 +
| style="text-align: right;" | 4371.5
 +
|-
 +
| Ammonium Chloride
 +
| 12125-02-9
 +
| style="text-align: right;" | 1
 +
| style="text-align: right;" | 0.00098
 +
| style="text-align: right;" | 87.43
 +
|-
 +
| Copolymer of 2-Propenamide
 +
| 69418-26-4
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.00231
 +
| style="text-align: right;" | 2622.9
 +
|-
 +
|- valign="top"
 +
| rowspan="4"| WFRA-405
 +
| rowspan="4"| U.S. Well Services
 +
| rowspan="4"| Friction Reducer
 +
| Hydrated light distillate (petroleum)
 +
| 64742-47-8
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.01618
 +
| style="text-align: right;" | 23575.2
 +
|-
 +
| 2-Propenoic acid, polymer with 2 propenamide
 +
| 9003-06-9
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.0201
 +
| style="text-align: right;" | 29285.9
 +
|-
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.0402
 +
| style="text-align: right;" | 58571.8
 +
|-
 +
| Ethoxylated alcohol blend
 +
| 68002-97-1
 +
| style="text-align: right;" | 4
 +
| style="text-align: right;" | 0.00268
 +
| style="text-align: right;" | 3904.79
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| K-BAC 1020
 +
| rowspan="2"| U.S. Well Services
 +
| rowspan="2"| Anti-Bacterial Agent
 +
| 2,2-dibromo-3-nitrilopropionamide
 +
| 10222-01-2
 +
| style="text-align: right;" | 20
 +
| style="text-align: right;" | 0.00978
 +
| style="text-align: right;" | 542.8
 +
|-
 +
| Deionized Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 28
 +
| style="text-align: right;" | 0.00559
 +
| style="text-align: right;" | 759.92
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| HCL Acid (12.6%-18.0%)
 +
| rowspan="2"| U.S. Well Services, LLC
 +
| rowspan="2"| Bulk Acid
 +
| Hydrogen Chloride
 +
| 7647-01-0
 +
| style="text-align: right;" | 18
 +
| style="text-align: right;" | 0.03799
 +
| style="text-align: right;" | 43104.7
 +
|-
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 87.5
 +
| style="text-align: right;" | 0.15904
 +
| style="text-align: right;" | 180454
 +
|-
 +
|- valign="top"
 +
| rowspan="4"| LGC-15
 +
| rowspan="4"| U.S. Well Services
 +
| rowspan="4"| Gelling Agents
 +
| Suspending agent (solid)
 +
| 14808-60-7
 +
| style="text-align: right;" | 3
 +
| style="text-align: right;" | 0.00004000
 +
| style="text-align: right;" | 2.07
 +
|-
 +
| Surfactant
 +
| 68439-51-0
 +
| style="text-align: right;" | 3
 +
| style="text-align: right;" | 0.00002000
 +
| style="text-align: right;" | 2.07
 +
|-
 +
| Guar Gum
 +
| 9000-30-0
 +
| style="text-align: right;" | 50
 +
| style="text-align: right;" | 0.00026
 +
| style="text-align: right;" | 34.5
 +
|-
 +
| Petroleum Distillates
 +
| 64742-47-8
 +
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.00024
 +
| style="text-align: right;" | 41.4
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Sand
 +
| rowspan="1"| U.S. Well Services, LLC
 +
| rowspan="1"| Proppant
 +
| Crystalline Silica, quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 14.5999
 +
| style="text-align: right;" | 16,566,000.0
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| AI-302
 +
| rowspan="2"| U.S. Well Services
 +
| rowspan="2"| Acid Corrosion Inhibitors
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 95
 +
| style="text-align: right;" | 0.00068
 +
| style="text-align: right;" | 93.1
 +
|-
 +
| 2-Propyn-1-olcompound with methyloxirane
 +
| 38172-91-7
 +
| style="text-align: right;" | 15
 +
| style="text-align: right;" | 0.00011
 +
| style="text-align: right;" | 14.7
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Water
 +
| rowspan="1"| Shell
 +
| rowspan="1"| Base Fluid
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 85.134
 +
| style="text-align: right;" | 96,598,500.0
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| SI-1200
 +
| rowspan="2"| U.S. Well Services
 +
| rowspan="2"| Scale Inhibitor
 +
| Ammonium Chloride
 +
| 12125-02-9
 +
| style="text-align: right;" | 2.5
 +
| style="text-align: right;" | 0.0008
 +
| style="text-align: right;" | 71.025
 +
|-
 +
| Phosphonated compound
 +
| Proprietary
 +
| style="text-align: right;" | 15
 +
| style="text-align: right;" | 0.00313
 +
| style="text-align: right;" | 426.15
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 120: Line 337:
 
!scope="col" | Waste Facility ID
 
!scope="col" | Waste Facility ID
 
|-
 
|-
| 2015-2
+
| 2015-S02
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
 
| style="text-align: right;" | 284.46 Tons
 
| style="text-align: right;" | 284.46 Tons
Line 126: Line 343:
 
| 301358
 
| 301358
 
|-
 
|-
| 2015-2
+
| 2015-S02
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
 
| style="text-align: right;" | 606.04 Tons
 
| style="text-align: right;" | 606.04 Tons
Line 132: Line 349:
 
| WMGR097R017
 
| WMGR097R017
 
|-
 
|-
| 2015-2
+
| 2015-S02
 
| Drilling Fluid Waste (in Barrels)
 
| Drilling Fluid Waste (in Barrels)
 
| style="text-align: right;" | 528.50 Bbl
 
| style="text-align: right;" | 528.50 Bbl
Line 138: Line 355:
 
|  
 
|  
 
|-
 
|-
| 2016-1
+
| 2016-S01
 
| Drill Cuttings (in Tons) RWC 810
 
| Drill Cuttings (in Tons) RWC 810
 
| style="text-align: right;" | 13.29 Tons
 
| style="text-align: right;" | 13.29 Tons
Line 144: Line 361:
 
| 301358
 
| 301358
 
|-
 
|-
| 2016-1
+
| 2016-S01
 
| Drilling Fluid Waste (in Barrels) RWC 803
 
| Drilling Fluid Waste (in Barrels) RWC 803
 
| style="text-align: right;" | 54.99 Bbl
 
| style="text-align: right;" | 54.99 Bbl
Line 150: Line 367:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2016-1
+
| 2016-S01
 
| Fracturing Fluid Waste (in Tons) RWC 805
 
| Fracturing Fluid Waste (in Tons) RWC 805
 
| style="text-align: right;" | 13,882.86 Tons
 
| style="text-align: right;" | 13,882.86 Tons
Line 156: Line 373:
 
|  
 
|  
 
|-
 
|-
| 2016-1
+
| 2016-S01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 599.94 Bbl
 
| style="text-align: right;" | 599.94 Bbl
Line 162: Line 379:
 
|  
 
|  
 
|-
 
|-
| 2016-1
+
| 2016-S01
 
| Waste Water Treatment Sludge (in Tons) RWC 804
 
| Waste Water Treatment Sludge (in Tons) RWC 804
 
| style="text-align: right;" | 439.92 Tons
 
| style="text-align: right;" | 439.92 Tons
Line 168: Line 385:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2016-2
+
| 2016-S02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 6,189.28 Bbl
 
| style="text-align: right;" | 6,189.28 Bbl
Line 174: Line 391:
 
|  
 
|  
 
|-
 
|-
| 2016-2
+
| 2016-S02
 
| Synthetic Liner Materials (in Tons) RWC 806
 
| Synthetic Liner Materials (in Tons) RWC 806
 
| style="text-align: right;" | 1.80 Tons
 
| style="text-align: right;" | 1.80 Tons
Line 180: Line 397:
 
| 301358
 
| 301358
 
|-
 
|-
| 2016-2
+
| 2016-S02
 
| Waste Water Treatment Sludge (in Tons) RWC 804
 
| Waste Water Treatment Sludge (in Tons) RWC 804
 
| style="text-align: right;" | 36.59 Tons
 
| style="text-align: right;" | 36.59 Tons
Line 186: Line 403:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2017-01
+
| 2017-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 300.00 Bbl
 
| style="text-align: right;" | 300.00 Bbl
Line 192: Line 409:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2017-01
+
| 2017-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 148.50 Bbl
 
| style="text-align: right;" | 148.50 Bbl
Line 198: Line 415:
 
|  
 
|  
 
|-
 
|-
| 2017-02
+
| 2017-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 749.99 Bbl
 
| style="text-align: right;" | 749.99 Bbl
Line 204: Line 421:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2017-03
+
| 2017-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 549.99 Bbl
 
| style="text-align: right;" | 549.99 Bbl
Line 210: Line 427:
 
|  
 
|  
 
|-
 
|-
| 2017-04
+
| 2017-M04
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 649.99 Bbl
 
| style="text-align: right;" | 649.99 Bbl
Line 216: Line 433:
 
|  
 
|  
 
|-
 
|-
| 2017-05
+
| 2017-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 294.49 Bbl
 
| style="text-align: right;" | 294.49 Bbl
Line 222: Line 439:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2017-06
+
| 2017-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 49.99 Bbl
 
| style="text-align: right;" | 49.99 Bbl
Line 228: Line 445:
 
|  
 
|  
 
|-
 
|-
| 2017-06
+
| 2017-M06
 
| Waste Water Treatment Sludge (in Tons) RWC 804
 
| Waste Water Treatment Sludge (in Tons) RWC 804
 
| style="text-align: right;" | 5.66 Tons
 
| style="text-align: right;" | 5.66 Tons
Line 234: Line 451:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2017-07
+
| 2017-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 300.00 Bbl
 
| style="text-align: right;" | 300.00 Bbl
Line 240: Line 457:
 
|  
 
|  
 
|-
 
|-
| 2017-08
+
| 2017-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 51.50 Bbl
 
| style="text-align: right;" | 51.50 Bbl
Line 246: Line 463:
 
| WMGR123NC010
 
| WMGR123NC010
 
|-
 
|-
| 2017-08
+
| 2017-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 469.99 Bbl
 
| style="text-align: right;" | 469.99 Bbl
Line 252: Line 469:
 
|  
 
|  
 
|-
 
|-
| 2017-09
+
| 2017-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 49.99 Bbl
 
| style="text-align: right;" | 49.99 Bbl
Line 258: Line 475:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2017-09
+
| 2017-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 150.00 Bbl
 
| style="text-align: right;" | 150.00 Bbl
Line 264: Line 481:
 
|  
 
|  
 
|-
 
|-
| 2017-10
+
| 2017-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 462.00 Bbl
 
| style="text-align: right;" | 462.00 Bbl
Line 270: Line 487:
 
|  
 
|  
 
|-
 
|-
| 2017-11
+
| 2017-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 100.50 Bbl
 
| style="text-align: right;" | 100.50 Bbl
Line 276: Line 493:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2017-11
+
| 2017-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 150.00 Bbl
 
| style="text-align: right;" | 150.00 Bbl
Line 282: Line 499:
 
|  
 
|  
 
|-
 
|-
| 2017-12
+
| 2017-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 224.00 Bbl
 
| style="text-align: right;" | 224.00 Bbl
Line 288: Line 505:
 
|  
 
|  
 
|-
 
|-
| 2018-01
+
| 2018-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 324.00 Bbl
 
| style="text-align: right;" | 324.00 Bbl
Line 294: Line 511:
 
|  
 
|  
 
|-
 
|-
| 2018-01
+
| 2018-M01
 
| Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811
 
| Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811
 
| style="text-align: right;" | 0.15 Tons
 
| style="text-align: right;" | 0.15 Tons
Line 300: Line 517:
 
| 7-3115-00193
 
| 7-3115-00193
 
|-
 
|-
| 2018-02
+
| 2018-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 133.33 Bbl
 
| style="text-align: right;" | 133.33 Bbl
Line 306: Line 523:
 
|  
 
|  
 
|-
 
|-
| 2018-03
+
| 2018-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 50.00 Bbl
 
| style="text-align: right;" | 50.00 Bbl
Line 312: Line 529:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2018-03
+
| 2018-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 50.00 Bbl
 
| style="text-align: right;" | 50.00 Bbl
Line 318: Line 535:
 
|  
 
|  
 
|-
 
|-
| 2018-04
+
| 2018-M04
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 303.00 Bbl
 
| style="text-align: right;" | 303.00 Bbl
Line 324: Line 541:
 
|  
 
|  
 
|-
 
|-
| 2018-05
+
| 2018-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 170.95 Bbl
 
| style="text-align: right;" | 170.95 Bbl
Line 330: Line 547:
 
| WMGR123NC010
 
| WMGR123NC010
 
|-
 
|-
| 2018-06
+
| 2018-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 412.49 Bbl
 
| style="text-align: right;" | 412.49 Bbl
Line 336: Line 553:
 
|  
 
|  
 
|-
 
|-
| 2018-07
+
| 2018-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 100.00 Bbl
 
| style="text-align: right;" | 100.00 Bbl
Line 342: Line 559:
 
|  
 
|  
 
|-
 
|-
| 2018-07
+
| 2018-M07
 
| Waste Water Treatment Sludge (in Tons) RWC 804
 
| Waste Water Treatment Sludge (in Tons) RWC 804
 
| style="text-align: right;" | 5.66 Tons
 
| style="text-align: right;" | 5.66 Tons
Line 348: Line 565:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2018-08
+
| 2018-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 50.00 Bbl
 
| style="text-align: right;" | 50.00 Bbl
Line 354: Line 571:
 
|  
 
|  
 
|-
 
|-
| 2018-09
+
| 2018-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 152.00 Bbl
 
| style="text-align: right;" | 152.00 Bbl
Line 360: Line 577:
 
|  
 
|  
 
|-
 
|-
| 2018-10
+
| 2018-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 57.90 Bbl
 
| style="text-align: right;" | 57.90 Bbl
Line 366: Line 583:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2018-10
+
| 2018-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 47.05 Bbl
 
| style="text-align: right;" | 47.05 Bbl
Line 372: Line 589:
 
| WMGR123NC010
 
| WMGR123NC010
 
|-
 
|-
| 2018-10
+
| 2018-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 50.00 Bbl
 
| style="text-align: right;" | 50.00 Bbl
Line 378: Line 595:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2018-10
+
| 2018-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 50.00 Bbl
 
| style="text-align: right;" | 50.00 Bbl
Line 384: Line 601:
 
|  
 
|  
 
|-
 
|-
| 2018-11
+
| 2018-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 90.52 Bbl
 
| style="text-align: right;" | 90.52 Bbl
Line 390: Line 607:
 
| WMGR123NC010
 
| WMGR123NC010
 
|-
 
|-
| 2018-11
+
| 2018-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 50.00 Bbl
 
| style="text-align: right;" | 50.00 Bbl
Line 396: Line 613:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2018-12
+
| 2018-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 50.00 Bbl
 
| style="text-align: right;" | 50.00 Bbl
Line 402: Line 619:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2018-12
+
| 2018-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 152.00 Bbl
 
| style="text-align: right;" | 152.00 Bbl
Line 408: Line 625:
 
|  
 
|  
 
|-
 
|-
| 2019-01
+
| 2019-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 50.00 Bbl
 
| style="text-align: right;" | 50.00 Bbl
Line 414: Line 631:
 
|  
 
|  
 
|-
 
|-
| 2019-02
+
| 2019-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 67.00 Bbl
 
| style="text-align: right;" | 67.00 Bbl
Line 537: Line 754:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
== Fracking Activities ==
 
==== Fracking Jobs ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Job Start Date
 
!scope="col" | Job End Date
 
!scope="col" | True Vertical Depth (ft)
 
!scope="col" | Total Water Volume (gal)
 
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
| 1
 
| 01/12/2016
 
| 01/23/2016
 
| style="text-align: right;" | 10824
 
| style="text-align: right;" | 11,582,600.0
 
| style="text-align: right;" | 0
 
|-
 
|}
 
==== Fluid Composition Data ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Trade Name
 
!scope="col" | Supplier
 
!scope="col" | Purpose
 
!scope="col" | Ingredient Name
 
!scope="col" | CAS Number
 
!scope="col" | Additive Percentage by Mass
 
!scope="col" | Job Percentage by Mass
 
!scope="col" | Mass Used (lb)
 
|-
 
|- valign="top"
 
| rowspan="24"| 1
 
| rowspan="6"| WFRA-2100
 
| rowspan="6"| U.S. Well Services
 
| rowspan="6"| Friction Reducer
 
| Alcohol Ethoxylate
 
| 68551-12-2
 
| style="text-align: right;" | 2
 
| style="text-align: right;" | 0.00129
 
| style="text-align: right;" | 174.86
 
|-
 
| Alkanolamide
 
| 93-83-4
 
| style="text-align: right;" | 2
 
| style="text-align: right;" | 0.00129
 
| style="text-align: right;" | 174.86
 
|-
 
| Hydrotreated Petroleum Distillates
 
| 64742-47-8
 
| style="text-align: right;" | 20
 
| style="text-align: right;" | 0.01041
 
| style="text-align: right;" | 1748.6
 
|-
 
| Water
 
| 7732-18-5
 
| style="text-align: right;" | 50
 
| style="text-align: right;" | 0.03213
 
| style="text-align: right;" | 4371.5
 
|-
 
| Ammonium Chloride
 
| 12125-02-9
 
| style="text-align: right;" | 1
 
| style="text-align: right;" | 0.00098
 
| style="text-align: right;" | 87.43
 
|-
 
| Copolymer of 2-Propenamide
 
| 69418-26-4
 
| style="text-align: right;" | 30
 
| style="text-align: right;" | 0.00231
 
| style="text-align: right;" | 2622.9
 
|-
 
|- valign="top"
 
| rowspan="4"| WFRA-405
 
| rowspan="4"| U.S. Well Services
 
| rowspan="4"| Friction Reducer
 
| Hydrated light distillate (petroleum)
 
| 64742-47-8
 
| style="text-align: right;" | 30
 
| style="text-align: right;" | 0.01618
 
| style="text-align: right;" | 23575.2
 
|-
 
| 2-Propenoic acid, polymer with 2 propenamide
 
| 9003-06-9
 
| style="text-align: right;" | 30
 
| style="text-align: right;" | 0.0201
 
| style="text-align: right;" | 29285.9
 
|-
 
| Water
 
| 7732-18-5
 
| style="text-align: right;" | 60
 
| style="text-align: right;" | 0.0402
 
| style="text-align: right;" | 58571.8
 
|-
 
| Ethoxylated alcohol blend
 
| 68002-97-1
 
| style="text-align: right;" | 4
 
| style="text-align: right;" | 0.00268
 
| style="text-align: right;" | 3904.79
 
|-
 
|- valign="top"
 
| rowspan="2"| K-BAC 1020
 
| rowspan="2"| U.S. Well Services
 
| rowspan="2"| Anti-Bacterial Agent
 
| 2,2-dibromo-3-nitrilopropionamide
 
| 10222-01-2
 
| style="text-align: right;" | 20
 
| style="text-align: right;" | 0.00978
 
| style="text-align: right;" | 542.8
 
|-
 
| Deionized Water
 
| 7732-18-5
 
| style="text-align: right;" | 28
 
| style="text-align: right;" | 0.00559
 
| style="text-align: right;" | 759.92
 
|-
 
|- valign="top"
 
| rowspan="2"| HCL Acid (12.6%-18.0%)
 
| rowspan="2"| U.S. Well Services, LLC
 
| rowspan="2"| Bulk Acid
 
| Hydrogen Chloride
 
| 7647-01-0
 
| style="text-align: right;" | 18
 
| style="text-align: right;" | 0.03799
 
| style="text-align: right;" | 43104.7
 
|-
 
| Water
 
| 7732-18-5
 
| style="text-align: right;" | 87.5
 
| style="text-align: right;" | 0.15904
 
| style="text-align: right;" | 180454
 
|-
 
|- valign="top"
 
| rowspan="4"| LGC-15
 
| rowspan="4"| U.S. Well Services
 
| rowspan="4"| Gelling Agents
 
| Suspending agent (solid)
 
| 14808-60-7
 
| style="text-align: right;" | 3
 
| style="text-align: right;" | 0.00004000
 
| style="text-align: right;" | 2.07
 
|-
 
| Surfactant
 
| 68439-51-0
 
| style="text-align: right;" | 3
 
| style="text-align: right;" | 0.00002000
 
| style="text-align: right;" | 2.07
 
|-
 
| Guar Gum
 
| 9000-30-0
 
| style="text-align: right;" | 50
 
| style="text-align: right;" | 0.00026
 
| style="text-align: right;" | 34.5
 
|-
 
| Petroleum Distillates
 
| 64742-47-8
 
| style="text-align: right;" | 60
 
| style="text-align: right;" | 0.00024
 
| style="text-align: right;" | 41.4
 
|-
 
|- valign="top"
 
| rowspan="1"| Sand
 
| rowspan="1"| U.S. Well Services, LLC
 
| rowspan="1"| Proppant
 
| Crystalline Silica, quartz
 
| 14808-60-7
 
| style="text-align: right;" | 100
 
| style="text-align: right;" | 14.5999
 
| style="text-align: right;" | 16,566,000.0
 
|-
 
|- valign="top"
 
| rowspan="2"| AI-302
 
| rowspan="2"| U.S. Well Services
 
| rowspan="2"| Acid Corrosion Inhibitors
 
| Water
 
| 7732-18-5
 
| style="text-align: right;" | 95
 
| style="text-align: right;" | 0.00068
 
| style="text-align: right;" | 93.1
 
|-
 
| 2-Propyn-1-olcompound with methyloxirane
 
| 38172-91-7
 
| style="text-align: right;" | 15
 
| style="text-align: right;" | 0.00011
 
| style="text-align: right;" | 14.7
 
|-
 
|- valign="top"
 
| rowspan="1"| Water
 
| rowspan="1"| Shell
 
| rowspan="1"| Base Fluid
 
| Water
 
| 7732-18-5
 
| style="text-align: right;" | 100
 
| style="text-align: right;" | 85.134
 
| style="text-align: right;" | 96,598,500.0
 
|-
 
|- valign="top"
 
| rowspan="2"| SI-1200
 
| rowspan="2"| U.S. Well Services
 
| rowspan="2"| Scale Inhibitor
 
| Ammonium Chloride
 
| 12125-02-9
 
| style="text-align: right;" | 2.5
 
| style="text-align: right;" | 0.0008
 
| style="text-align: right;" | 71.025
 
|-
 
| Phosphonated compound
 
| Proprietary
 
| style="text-align: right;" | 15
 
| style="text-align: right;" | 0.00313
 
| style="text-align: right;" | 426.15
 
|-
 
|}
 
For data sources see<ref>{{cite web
 
| title =FracFocus Fracking Chemicals Database
 
| date = 2019-04-02
 
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
| accessdate = 2019-06-19 }}</ref>
 
 
==References==
 
==References==
 
<references/>
 
<references/>

Revision as of 15:09, 2 August 2019

Well Details

Well ID: 37-117-21792
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Osceola Township
Operator Name: SWEPI LP
Well Pad ID: 149357
Farm/Lease Name: STANLEY 1106 23H
License Status: Active
Spud Date: 2015-10-13
Permit Date: 2015-08-06
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.943136
Longitude: -77.356242

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2016-01-12 2016-01-23 10824 11,582,600.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 WFRA-2100 U.S. Well Services Friction Reducer Alcohol Ethoxylate 68551-12-2 2 0.00129 174.86
Alkanolamide 93-83-4 2 0.00129 174.86
Hydrotreated Petroleum Distillates 64742-47-8 20 0.01041 1748.6
Water 7732-18-5 50 0.03213 4371.5
Ammonium Chloride 12125-02-9 1 0.00098 87.43
Copolymer of 2-Propenamide 69418-26-4 30 0.00231 2622.9
WFRA-405 U.S. Well Services Friction Reducer Hydrated light distillate (petroleum) 64742-47-8 30 0.01618 23575.2
2-Propenoic acid, polymer with 2 propenamide 9003-06-9 30 0.0201 29285.9
Water 7732-18-5 60 0.0402 58571.8
Ethoxylated alcohol blend 68002-97-1 4 0.00268 3904.79
K-BAC 1020 U.S. Well Services Anti-Bacterial Agent 2,2-dibromo-3-nitrilopropionamide 10222-01-2 20 0.00978 542.8
Deionized Water 7732-18-5 28 0.00559 759.92
HCL Acid (12.6%-18.0%) U.S. Well Services, LLC Bulk Acid Hydrogen Chloride 7647-01-0 18 0.03799 43104.7
Water 7732-18-5 87.5 0.15904 180454
LGC-15 U.S. Well Services Gelling Agents Suspending agent (solid) 14808-60-7 3 0.00004000 2.07
Surfactant 68439-51-0 3 0.00002000 2.07
Guar Gum 9000-30-0 50 0.00026 34.5
Petroleum Distillates 64742-47-8 60 0.00024 41.4
Sand U.S. Well Services, LLC Proppant Crystalline Silica, quartz 14808-60-7 100 14.5999 16,566,000.0
AI-302 U.S. Well Services Acid Corrosion Inhibitors Water 7732-18-5 95 0.00068 93.1
2-Propyn-1-olcompound with methyloxirane 38172-91-7 15 0.00011 14.7
Water Shell Base Fluid Water 7732-18-5 100 85.134 96,598,500.0
SI-1200 U.S. Well Services Scale Inhibitor Ammonium Chloride 12125-02-9 2.5 0.0008 71.025
Phosphonated compound Proprietary 15 0.00313 426.15

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2015 SWEPI LP 0.00 0 0.00 0 0.00 0
2016 SWEPI LP 4,080,702.69 294 0.00 0 0.00 0
2017 SWEPI LP 3,232,212.90 362 0.00 0 0.00 0
2018 SWEPI LP 1,767,550.11 356 0.00 0 0.00 0
2019 SWEPI LP 360,352.47 89 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2015-S02 Drill Cuttings (in Tons) 284.46 Tons LANDFILL 301358
2015-S02 Drill Cuttings (in Tons) 606.04 Tons RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR097R017
2015-S02 Drilling Fluid Waste (in Barrels) 528.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S01 Drill Cuttings (in Tons) RWC 810 13.29 Tons LANDFILL 301358
2016-S01 Drilling Fluid Waste (in Barrels) RWC 803 54.99 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2016-S01 Fracturing Fluid Waste (in Tons) RWC 805 13,882.86 Tons REUSE OTHER THAN ROAD SPREADING
2016-S01 Produced Fluid (in Barrels) RWC 802 599.94 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S01 Waste Water Treatment Sludge (in Tons) RWC 804 439.92 Tons RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2016-S02 Produced Fluid (in Barrels) RWC 802 6,189.28 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S02 Synthetic Liner Materials (in Tons) RWC 806 1.80 Tons LANDFILL 301358
2016-S02 Waste Water Treatment Sludge (in Tons) RWC 804 36.59 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017-M01 Produced Fluid (in Barrels) RWC 802 300.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-M01 Produced Fluid (in Barrels) RWC 802 148.50 Bbl REUSE (AT WELL PAD)
2017-M02 Produced Fluid (in Barrels) RWC 802 749.99 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-M03 Produced Fluid (in Barrels) RWC 802 549.99 Bbl REUSE (AT WELL PAD)
2017-M04 Produced Fluid (in Barrels) RWC 802 649.99 Bbl REUSE (AT WELL PAD)
2017-M05 Produced Fluid (in Barrels) RWC 802 294.49 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-M06 Produced Fluid (in Barrels) RWC 802 49.99 Bbl REUSE (AT WELL PAD)
2017-M06 Waste Water Treatment Sludge (in Tons) RWC 804 5.66 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-M07 Produced Fluid (in Barrels) RWC 802 300.00 Bbl REUSE (AT WELL PAD)
2017-M08 Produced Fluid (in Barrels) RWC 802 51.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017-M08 Produced Fluid (in Barrels) RWC 802 469.99 Bbl REUSE (AT WELL PAD)
2017-M09 Produced Fluid (in Barrels) RWC 802 49.99 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-M09 Produced Fluid (in Barrels) RWC 802 150.00 Bbl REUSE (AT WELL PAD)
2017-M10 Produced Fluid (in Barrels) RWC 802 462.00 Bbl REUSE (AT WELL PAD)
2017-M11 Produced Fluid (in Barrels) RWC 802 100.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-M11 Produced Fluid (in Barrels) RWC 802 150.00 Bbl REUSE (AT WELL PAD)
2017-M12 Produced Fluid (in Barrels) RWC 802 224.00 Bbl REUSE (AT WELL PAD)
2018-M01 Produced Fluid (in Barrels) RWC 802 324.00 Bbl REUSE (AT WELL PAD)
2018-M01 Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 0.15 Tons RESIDUAL WASTE TRANSFER FACILITY 7-3115-00193
2018-M02 Produced Fluid (in Barrels) RWC 802 133.33 Bbl REUSE (AT WELL PAD)
2018-M03 Produced Fluid (in Barrels) RWC 802 50.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-M03 Produced Fluid (in Barrels) RWC 802 50.00 Bbl REUSE (AT WELL PAD)
2018-M04 Produced Fluid (in Barrels) RWC 802 303.00 Bbl REUSE (AT WELL PAD)
2018-M05 Produced Fluid (in Barrels) RWC 802 170.95 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-M06 Produced Fluid (in Barrels) RWC 802 412.49 Bbl REUSE (AT WELL PAD)
2018-M07 Produced Fluid (in Barrels) RWC 802 100.00 Bbl REUSE (AT WELL PAD)
2018-M07 Waste Water Treatment Sludge (in Tons) RWC 804 5.66 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018-M08 Produced Fluid (in Barrels) RWC 802 50.00 Bbl REUSE (AT WELL PAD)
2018-M09 Produced Fluid (in Barrels) RWC 802 152.00 Bbl REUSE (AT WELL PAD)
2018-M10 Produced Fluid (in Barrels) RWC 802 57.90 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018-M10 Produced Fluid (in Barrels) RWC 802 47.05 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-M10 Produced Fluid (in Barrels) RWC 802 50.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-M10 Produced Fluid (in Barrels) RWC 802 50.00 Bbl REUSE (AT WELL PAD)
2018-M11 Produced Fluid (in Barrels) RWC 802 90.52 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-M11 Produced Fluid (in Barrels) RWC 802 50.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-M12 Produced Fluid (in Barrels) RWC 802 50.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-M12 Produced Fluid (in Barrels) RWC 802 152.00 Bbl REUSE (AT WELL PAD)
2019-M01 Produced Fluid (in Barrels) RWC 802 50.00 Bbl REUSE (AT WELL PAD)
2019-M02 Produced Fluid (in Barrels) RWC 802 67.00 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2446961 Primary Facility 2016-02-02 Incident- Response to Accident or Event Viol(s) Noted & Immediately Corrected The Department inspected the SWEPI LP - Stanley 1106 (ESX10-117-0243) located in Osceola Twp., Tioga Co. in response to notification of a spill by Patrick Bernethy, Environmental/Regulatory Tech from Shell Appalachia. Mr. Bernethy contact the WSQ @ 1150 hours on 1/26/2016 to notify the Department that SWEPI LP removed the temporary containment liner used during well completion activities on the 23 H well (API#117-21792) at the Stanley 1106 pad. As part of SWEPI LP’s standard procedures, soil conductivity readings were collected from the pad following the liner removal. Soil conductivity measurement points exhibited readings above background in the area of the temporary liner; approximately 6-8 mS. SWEPI LP was not notified during completion activities of any spills by the completions contractor, US Well Services.
2481524 Primary Facility 2016-04-28 Administrative/File Review No Violations Noted 4/28/16: The DEP has received a Remedial Action Completion Report noting the following:

On January 26, 2016, while conducting an environmental assessment following well development activities at the Stanley 1106 well pad, SWEPI personnel identified an area of the pad exhibiting soil conductivities readings above background. Shell notified the Department of its findings that same day and elected to remediate the area affected area. SWEPI LP contracted Matt Bailey (AMEC Foster Wheeler) to conduct an environmental pad screening from 1-26-16 to 1-28-16 for both well and staging pad, screening was also conducted on drainage ditches and the sediment basin to the north of the well pad. Impacts were not detected beyond the gravel surface of the pad. From Jan. 27, 2016 through Jan. 29, 2016 approximately 800 tons of impacted gravel were excavated and disposed of at the Waste Management Landfill. The Remedial Action Completion Report documents the post remediation sample locations, sample results and disposal rece

2487541 Primary Facility 2016-05-26 Routine/Complete Inspection No Violations Noted he Department of Environmental Protection (DEP) inspected the SWEPI LP – Stanley 1106 site, in Osceola Twp., Tioga Co. on 5/26/2016 @0950 hours, in response to notification by SWEPI of suspected vandalism. The weather was mostly cloudy 75 degrees with winds S 7mph. SWEPI Env. Coordinator, Pat Bernethy stated the production tank that was installed for the 23H well appeared to have a faulty gasket around the heater. This had allowed production fluid to seep into the permanent causing elevated conductivity in the accumulated fluid. The gasket was repaired and the fluid was removed from the containment. According to Mr. Bernethy ~1-2 weeks later a small area of damp soil appeared to be coming from underneath the permanent containment. The gravel inside the containment was removed and the liner was inspected for holes. Approximately 8 puncture holes and 1 large gash were observed along a 5 foot length of containment. SWEPI stated it suspects it was an act of vandalism. There is no gate at the site entrance and no
2542025 Primary Facility 2016-05-09 Administrative/File Review No Violations Noted The Department of Environmental Protection has reviewed the April 20, 2016 document titled “Remedial Action Completion Report” for the SWEPI – Stanley 1106 Well Pad prepared by SWEPI and submitted to the DEP. The DEP has reviewed the subject document in accordance with the Alternative Remediation provision of the department policy document 800 – 5000–001 addressing spills and releases at oil and gas Well Sites or Access Roads. No technical deficiencies were noted.
2553030 Primary Facility 2017-01-18 Routine/Complete Inspection No Violations Noted The Department of Environmental Protection (DEP) conducted a routine inspection at the Stanley 1106 well site located in Deerfield Twp., Tioga Co. on 1/30/2017. The weather is 29° and cloudy northwest winds 13 mph. Three wells wereobserved drilled on the pad. Two wells appear to be in production. A large puddle near the well heads and some production equipment has a field measured conductivity of 150 microsiemens/cm. A new ESCGP-2 has been issued for the site to facilitate a pad build-out complete with installation of PCSM features. Cut and fill slopes appear stabilized by >70% perennial vegetation. No violations were noted during this inspection. Please contact me with any questions. Pictures are attached to the ESCGP file copy of the inspection report.
2595394 Primary Facility 2017-05-18 Routine/Partial Inspection No Violations Noted EC readings w an Oakton PCSTestr 35: wheelie trl liner--0.24 mS/cm, prod tank liner--0.50 mS/cm, basin--0.61

On site ~1355-1445 hrs

2639226 Primary Facility 2017-09-22 Site Restoration No Violations Noted Electrical conductivity readings with Oakton PCSTestr 35 (mS/cm): wheelie trailer containment--2.7, pad--0.45, production tank containment--0.51.
2855599 Primary Facility 2019-03-19 Routine/Complete Inspection No Violations Noted The DEP conducted a routine inspection of SWEPI's Stanley 1106 Well Pad in Osceola Twp, Tioga County on 3/19/2019 at 1145 hours. The weather was partly cloudy and 41 degrees. The act 9 sign was observed at the site entrance. The E&S Plan was in the mailbox by the entrance. The inspection log was in the mailbox by the production tank and company personnel last inspected the site on 3/16/2019, noting no issues.

There is currently 2 producing wells onsite. The 2H is a Marcellus well and the 23H is a Utica well. The site is very well vegetated and stabilized. The reclaimed pony pad to the north was hardly noticeable. No erosion was observed onsite. Containment structures were intact and no leaks or spills were observed. PCSM BMPs were installed per the site plan.

No violations or issues noted. I departed the site at 1215 hours.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2446961 745063 2016-02-02 2016-02-02 78.57(a) Environmental Health & Safety The Department inspected the SWEPI LP - Stanley 1106 (ESX10-117-0243) located in Osceola Twp., Tioga Co. in response to notification of a spill by Patrick Bernethy, Environmental/Regulatory Tech from Shell Appalachia. Mr. Bernethy contact the WSQ @ 1150 hours on 1/26/2016 to notify the Department th

For data sources see[7]