If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 11: | Line 11: | ||
| County: [[Columbiana_County,_Ohio|Columbiana]] | | County: [[Columbiana_County,_Ohio|Columbiana]] | ||
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[Perry Township,_Columbiana_County,_Ohio|Perry Township]] |
|- | |- | ||
| Operator Name: [[ERIC PETROLEUM CORP]] | | Operator Name: [[ERIC PETROLEUM CORP]] | ||
Line 33: | Line 33: | ||
| Configuration: Vertical | | Configuration: Vertical | ||
|- | |- | ||
− | | Latitude: | + | | Latitude: <Latitude> |
|- | |- | ||
| Longitude: -80.89449341 | | Longitude: -80.89449341 |
Well ID: 34-029-21645 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.923037182,"lon":-80.89449341,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Columbiana | |
Municipality: Perry Township | |
Operator Name: ERIC PETROLEUM CORP | |
Well Pad ID: | |
Farm/Lease Name: SLANKER WILLIAM ETAL | |
License Status: Producing | |
License Date: 2006-07-19 | |
Spud Date: 2007-01-18 | |
Spud Drilling Contractor: ADVENT DRLG | |
Final Drill Date: 2007-01-22 | |
Well Total Depth: 5683 ft | |
Configuration: Vertical | |
Latitude: <Latitude> | |
Longitude: -80.89449341 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2006-07-19 | Proposed Formations:CLINTON, Issued Date:7/19/2006, Expired Date:7/19/2007 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL |
Completed | 2007-01-22 | |
Reached Total Depth | 2007-01-22 | |
Construction Permit Expires | 2007-07-19 | |
Completion Report Received | 2008-01-10 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-03-11 | 5473 | 5532 | 54 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 12 | 81000 Gal | 40000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | ERIC PETROLEUM CORP | 462 | 0 | 65 |
2009 | ERIC PETROLEUM CORP | 585 | 122 | 65 |
2010 | ERIC PETROLEUM CORP | 51 | 0 | 365 |
2011 | ERIC PETROLEUM CORP | 319 | 44 | 365 |
2012 | ERIC PETROLEUM CORP | 173 | 66 | 366 |
2013 | ERIC PETROLEUM CORP | 0 | 0 | 365 |
2014 | ERIC PETROLEUM CORP | 22 | 0 | 365 |
2015 | ERIC PETROLEUM CORP | 75 | 0 | 365 |
2016 | ERIC PETROLEUM CORP | 44 | 0 | 365 |
2017 | ERIC PETROLEUM CORP | 2 | 0 | 365 |
2018 | ERIC PETROLEUM CORP | 2 | 0 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | ERIC PETROLEUM CORP | Brine | 972 | 65 |
2009 | ERIC PETROLEUM CORP | Brine | 803 | 65 |
2010 | ERIC PETROLEUM CORP | Brine | 128 | 365 |
2011 | ERIC PETROLEUM CORP | Brine | 844 | 365 |
2012 | ERIC PETROLEUM CORP | Brine | 0 | 366 |
2013 | ERIC PETROLEUM CORP | Brine | 435 | 365 |
2014 | ERIC PETROLEUM CORP | Brine | 0 | 365 |
2015 | ERIC PETROLEUM CORP | Brine | 0 | 365 |
2016 | ERIC PETROLEUM CORP | Brine | 0 | 365 |
2017 | ERIC PETROLEUM CORP | Brine | 0 | 365 |
2018 | ERIC PETROLEUM CORP | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0054699249 | 2008-01-29 | Preliminary Restoration | No Violations | Inspection revealed that the preliminary restoration can be approved at this time. No violations at this time. |
1044704558 | 2016-11-02 | Production Wells | No Violations | The purpose of my inspection was to conduct a status check of well # 2-1645. A review of RBDMS indicates the Owner is current with reporting production. The lease access is also utilized for agriculture and remains stable. The well location is within an agricultural field and is stable. No identification is posted at the well head. The 8.625 well is at grade. The 4.5 production casing is equipped with a casing gas powered pump jack. A pressure gauge installed on the production casing indicated 120#. The lower production valve was in the open position. No audible or visual leaks were detected. A domestic supply connection is present. An earthen dike that is stable and sufficient is constructed around the production equipment. Equipment within the dike consists of one (1) vertical separator, one (1) 100 bbl production tank and one (1) 35 bbl poly brine tank. Minimum spacing requirements are met. The separator remains in good repair with no audible or visual leaks. A current 7 day production chart is in the meter house. The production tank contains correct and legible identification placed conspicuously on the tank body. The tank remains in good repair with no leaks. The drain line valve is closed and plugged. The brine drain valve is closed and plumbed to the brine tank. The hatch lid was closed. The poly brine tank is in good repair with no cracks. The inlet valve is closed. The brine tank was not holding any production fluid. No violations were observed during this inspection. |
1435191069 | 2014-09-17 | Production Wells | No Violations | I was on site to conduct a status check. Identification was posted on the tank battery and was legible. The tank battery consists of one 100 bbl production tank, a 50 bbl poly brine tank, and one vertical separator. The tank valves were plugged. There is a meter box with a current chart. The dike is present and in good repair. The wellhead is equipped with a gas powered pump jack and a domestic supply line. The access road, wellhead, and tank battery sites are stable. |
1735350904 | 2007-01-16 | Drill / Deepen / Reopen | No Violations | Trying to find location because Advent Drlg is suppose to be building location and moving onto location this week. Inspection revealed equipment on site building the location. No violations at this time. |
1967071621 | 2007-01-22 | Drill / Deepen / Reopen | No Violations |
For data sources see[9]