X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-035-22032"

m
m
Line 11: Line 11:
 
| County: [[Cuyahoga_County,_Ohio|Cuyahoga]]
 
| County: [[Cuyahoga_County,_Ohio|Cuyahoga]]
 
|-
 
|-
| Municipality: [[Chagrin_Falls_Township,_Cuyahoga_County,_Ohio|Chagrin Falls Township]]
+
| Municipality: [[Bentleyville Village,_Cuyahoga_County,_Ohio|Bentleyville Village]]
 
|-
 
|-
 
| Operator Name: [[EOS ENERGY LLC]]
 
| Operator Name: [[EOS ENERGY LLC]]
Line 33: Line 33:
 
| Configuration: Vertical
 
| Configuration: Vertical
 
|-
 
|-
| Latitude: 41.402390582
+
| Latitude: <Latitude>
 
|-
 
|-
 
| Longitude: -81.41892560
 
| Longitude: -81.41892560

Revision as of 10:25, 14 August 2019

Well Details

Well ID: 34-035-22032
Loading map...
Country: United States
State: Ohio
County: Cuyahoga
Municipality: Bentleyville Village
Operator Name: EOS ENERGY LLC
Well Pad ID:
Farm/Lease Name: FELKER-PARKER UNIT
License Status: Producing
License Date: 2008-04-16
Spud Date: 2008-10-13
Spud Drilling Contractor: H A D INC
Final Drill Date: 2008-10-17
Well Total Depth: 3842 ft
Configuration: Vertical
Latitude: <Latitude>
Longitude: -81.41892560

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-04-16 Proposed Formations:OHIO SHALE-CLINTON, Issued Date:4/16/2008, Expired Date:4/16/2009 6:00:00 AM, Drilling unit acres:20.467, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-10-17
Completion Report Received 2008-12-23
Construction Permit Expires 2009-04-16
Change of Owner 2018-07-31 Operator changed from 1249, CUTTER OIL COMPANY to 10185, EOS ENERGY LLC
Record Last Modified 2018-07-31

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-01-20 3591 3609 18

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 180 Mscf 47500

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 CUTTER OIL COMPANY 0 0 365
2009 CUTTER OIL COMPANY 35930 0 365
2010 CUTTER OIL COMPANY 24298 75 365
2011 CUTTER OIL COMPANY 23393 34 365
2012 CUTTER OIL COMPANY 17398 0 366
2013 CUTTER OIL COMPANY 10964 53 365
2014 CUTTER OIL COMPANY 11507 0 365
2015 CUTTER OIL COMPANY 9148 0 365
2016 CUTTER OIL COMPANY 8156 0 365
2017 CUTTER OIL COMPANY 8514 0 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 CUTTER OIL COMPANY Brine 1570 365
2009 CUTTER OIL COMPANY Brine 497 365
2010 CUTTER OIL COMPANY Brine 328 365
2011 CUTTER OIL COMPANY Brine 237 365
2012 CUTTER OIL COMPANY Brine 192 366
2013 CUTTER OIL COMPANY Brine 188 365
2014 CUTTER OIL COMPANY Brine 348 365
2015 CUTTER OIL COMPANY Brine 74 365
2016 CUTTER OIL COMPANY Brine 218 365
2017 CUTTER OIL COMPANY Brine 261 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0234653006 2017-07-07 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The wellhead and battery are located in a small clearing in a mostly wooded area. The wellhead plunger and battery are in separate board-on-board enclosures which are locked. Fittings and connections are secure and free from signs of leakage or problems. The load-outs are secure, plugged, and locked. Process safety gear is present. Signage is in place. I walked the areas surrounding the well and battery and found no observable signs of impact to the natural greenscape.
0617168065 2013-10-07 UrbanProduction Wells No Violations The producing unit consists of a pump jack unit at the wellhead, enclosed in a board-on-board enclosure and aboveground storage tank (AST) battery in separate board-on-board enclosure. The battery is comprised of 2 140-barrel steel production tanks, a 50 barrel poly brine tank. And a separator unit. There is a remote heater unit in a chain-link enclosure. Spacing and secondary containment is good. Unit identification is good. Lease road is in good condition. No problems noted.
1373309782 2013-07-08 UrbanPreliminary Restoration No Violations The producing unit consists of a an above-ground storage tank (AST) battery with 2 140-barrel steel production tanks, and 1 50-barrel steel brine tank, a mechanical separator, and metering run. Identification is present. There is an earthen secondary containment which is in good condition. The load-outs are bull-plugged. Safety equipment is present. The wellhead is located 50 feet north of the battery. The wellhead consists of a pumpjack system and associated valve-tree. There is earthen secondary containment at the wellhead as well. The wellhead and battery are in separate board-on-board enclosures which are locked. There is a separate indirect-fire heater located 50 feet from the wellhead in a chain-link enclosure. The lease road is primarily shared with the residential driveway. A small dedicated portion is paved with mixed, coarse limestone aggregate. I did not observe any problems or violations. Preliminary restoration passes.
1593589844 2008-10-14 Drill / Deepen / Reopen No Violations on site for surface cementing
1645972941 2009-04-27 Preliminary Restoration No Violations
1712568768 2018-06-22 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of my inspection, I found the following: a wellhead with pump jack system and associated tank battery in separate board-on-board enclosures. The enclosure gates were locked and secure. The load lines were secure and locked. Fittings and connections were free from leakage or problems. The well was in production with active chart record.

For data sources see[9]