| County: [[Trumbull_County,_Ohio|Trumbull]] | | County: [[Trumbull_County,_Ohio|Trumbull]] | ||
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[Howland Township,_Trumbull_County,_Ohio|Howland Township]] |
|- | |- | ||
| Operator Name: [[EVERFLOW EASTERN PTNS L P]] | | Operator Name: [[EVERFLOW EASTERN PTNS L P]] |
Well ID: 34-155-23250 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.214230292,"lon":-80.73180188,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Howland Township | |
Operator Name: EVERFLOW EASTERN PTNS L P | |
Well Pad ID: | |
Farm/Lease Name: STERLE | |
License Status: Producing | |
License Date: 1988-12-09 | |
Spud Date: 1989-07-05 | |
Spud Drilling Contractor: [[JL COATS [COATS-GOFF]]] | |
Final Drill Date: 1989-07-10 | |
Well Total Depth: 4963 ft | |
Configuration: Vertical | |
Latitude: 41.214230292 | |
Longitude: -80.73180188 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1988-12-09 | Issued Date 12/9/88 Expired Date 12/9/89 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 04963 Proposed Drill Depth 04963 |
Original Spud | 1989-06-30 | CHG. FTG. 3-24-90 |
Completed | 1989-07-10 | CHG. FTG. 3-24-90 |
Reached Total Depth | 1989-07-10 | CHG. FTG. 3-24-90 |
CO | 1989-08-10 | 2651 D & L ENERGY INC GeoDate 12/9/88 |
Completion Report Received | 1989-08-17 | CHG. FTG. 3-24-90 |
Construction Permit Expires | 1989-12-09 | CHG. FTG. 3-24-90 |
Change of Owner | 2013-08-13 | Operator changed from 2651, D & L ENERGY INC to 84, EVERFLOW EASTERN PTNS L P |
Record Last Modified | 2017-02-15 | CHG. FTG. 3-24-90 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 4645 | 4800 | 0 |
2006-09-11 | 4704 | 4752 | 35 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 96000 Gal | 70000 | FRAC:SAND/WATER |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0871494665 | 2016-11-16 | UrbanProduction Wells | No Violations | At the time of my inspection, I found the well in production. The well is equipped with a plunger lift assembly. The diked tank battery has two (2) storage tanks and a locked separator. An identification sign is posted at the tank battery. The load line is secure with a plug. The access road is in good repair.
The equipment on the site consists of the following:
|
1296169054 | 2014-01-13 | UrbanProduction Wells | No Violations | My inspection found the well in production. The well was equipped with a plunger lift unit. The tank battery consisted of a 100 barrel production tank, a 50 barrel brine tank, and a separator. The dike met containment requirements. There was a lock and plug on the load line. Half of the identification sign was missing. All of the production equipment spacing was incompliance. The lease road was in good condition. I contacted Everflow and told the well tender to replace the identification sign. The well was placed into production prior to House Bill 278. |
1390482822 | 2014-01-23 | UrbanProduction Wells | No Violations | My inspection found a new identification sign properly posted per my request. |
For data sources see[9]