If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 11: | Line 11: | ||
| County: [[Morgan_County,_Ohio|Morgan]] | | County: [[Morgan_County,_Ohio|Morgan]] | ||
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[Center Township,_Morgan_County,_Ohio|Center Township]] |
|- | |- | ||
| Operator Name: [[NORTHWOOD ENERGY CORP]] | | Operator Name: [[NORTHWOOD ENERGY CORP]] |
Well ID: 34-115-23702 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.617509968,"lon":-81.62835007,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Morgan | |
Municipality: Center Township | |
Operator Name: NORTHWOOD ENERGY CORP | |
Well Pad ID: | |
Farm/Lease Name: CLARK HEIRS | |
License Status: Producing | |
License Date: 1984-10-30 | |
Spud Date: 1984-12-17 | |
Spud Drilling Contractor: BURDETTE DRLG | |
Final Drill Date: 1984-12-21 | |
Well Total Depth: 5647 ft | |
Configuration: Vertical | |
Latitude: 39.617509968 | |
Longitude: -81.62835007 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1984-10-30 | 1634 NORTHWOOD ENERGY CORP GeoDate 10/30/84 |
Oil and Gas | 1984-10-30 | Issued Date 10/30/84 Expired Date 4/28/85 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 05647 Proposed Drill Depth 05647 |
Original Spud | 1984-12-17 | |
Completed | 1984-12-21 | |
Reached Total Depth | 1984-12-21 | |
Completion Report Received | 1985-01-10 | |
Construction Permit Expires | 1985-04-28 | |
Last Compliance Report | 2016-11-10 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 5400 | 5460 | 0 |
2006-09-11 | 5409 | 5525 | 15 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
N2 | 0 | 174 Mscf | 55000 | FRAC: H2O,SAND,N2 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0000PL9465 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0684396131 | 2004-03-15 | Production Wells | No Violations | Rabbit well,no violations noted on the day of my inspection. |
1123881622 | 2005-08-09 | Production Wells | No Violations | No violations noted,well is equipped with 1-100bbl tank,separator(rabbit well).
I.D. needs to be refreshed and dike repaired when SPPC rules go into effect. |
1440845940 | 2016-09-07 | Temporary Abandoned Annular Disposal | No Violations | The inspection today revealed that this well is capable of production through the casing. The AD is not hooked up at the time of inspection and there are no issues to report at this time. I was unable to locate the tanks at the time of inspection. |
1898917603 | 2017-02-27 | Production Wells | No Violations | The inspection this day revealed that this well is equipped with a plunger lift system, 4 1/2 inch diameter wellhead, and 1 1/2 inch diameter production tubing. The valves on the wellhead are currently open at the time of inspection. The tank battery is equipped with a separator and a 100 barrel steel tank. There are no issues to report at this time and the well is producing at the time of inspection. |
For data sources see[9]