X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-099-22082"

m
m
Line 11: Line 11:
 
| County: [[Mahoning_County,_Ohio|Mahoning]]
 
| County: [[Mahoning_County,_Ohio|Mahoning]]
 
|-
 
|-
| Municipality: [[Boardman_Township,_Mahoning_County,_Ohio|Boardman Township]]
+
| Municipality: [[Boardman Township,_Mahoning_County,_Ohio|Boardman Township]]
 
|-
 
|-
 
| Operator Name: [[EVERFLOW EASTERN PTNS L P]]
 
| Operator Name: [[EVERFLOW EASTERN PTNS L P]]

Revision as of 17:57, 14 August 2019

Well Details

Well ID: 34-099-22082
Loading map...
Country: United States
State: Ohio
County: Mahoning
Municipality: Boardman Township
Operator Name: EVERFLOW EASTERN PTNS L P
Well Pad ID:
Farm/Lease Name: OHLIN
License Status: Producing
License Date: 1986-11-22
Spud Date: 1987-01-01
Spud Drilling Contractor: CUBBY DRLG
Final Drill Date: 1987-01-06
Well Total Depth: 5946 ft
Configuration: Vertical
Latitude: 40.990121461
Longitude: -80.63689534

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1987-01-01
Completed 1987-01-06
Reached Total Depth 1987-01-06
Completion Report Received 1987-04-24
Record Last Modified 2013-10-03

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1998-09-21 5741 5810 20
1998-09-21 5898 5908 11

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 115000 Gal 64000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1987 EVERFLOW EASTERN PTNS L P 1524 0 365
1988 EVERFLOW EASTERN PTNS L P 25307 0 365
1989 EVERFLOW EASTERN PTNS L P 17733 0 365
1990 EVERFLOW EASTERN PTNS L P 11770 0 365
1991 EVERFLOW EASTERN PTNS L P 8235 0 365
1992 EVERFLOW EASTERN PTNS L P 6188 0 365
1993 EVERFLOW EASTERN PTNS L P 4630 0 365
1994 EVERFLOW EASTERN PTNS L P 6121 0 365
1995 EVERFLOW EASTERN PTNS L P 4839 0 365
1996 EVERFLOW EASTERN PTNS L P 3773 0 365
1997 EVERFLOW EASTERN PTNS L P 4416 0 365
1998 EVERFLOW EASTERN PTNS L P 2717 0 365
1999 EVERFLOW EASTERN PTNS L P 3644 0 365
2000 EVERFLOW EASTERN PTNS L P 2739 0 365
2001 EVERFLOW EASTERN PTNS L P 2488 0 365
2002 EVERFLOW EASTERN PTNS L P 1652 0 365
2003 EVERFLOW EASTERN PTNS L P 1877 0 365
2004 EVERFLOW EASTERN PTNS L P 1359 0 365
2005 EVERFLOW EASTERN PTNS L P 1138 0 365
2006 EVERFLOW EASTERN PTNS L P 1114 0 365
2007 EVERFLOW EASTERN PTNS L P 878 0 365
2008 EVERFLOW EASTERN PTNS L P 1021 0 365
2009 EVERFLOW EASTERN PTNS L P 1080 0 365
2010 EVERFLOW EASTERN PTNS L P 984 0 365
2011 EVERFLOW EASTERN PTNS L P 911 0 365
2012 EVERFLOW EASTERN PTNS L P 596 0 276
2013 EVERFLOW EASTERN PTNS L P 452 0 185
2014 EVERFLOW EASTERN PTNS L P 576 0 95
2015 EVERFLOW EASTERN PTNS L P 41 0 365
2016 EVERFLOW EASTERN PTNS L P 137 0 365
2017 EVERFLOW EASTERN PTNS L P 766 0 365
2018 EVERFLOW EASTERN PTNS L P 468 0 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1987 EVERFLOW EASTERN PTNS L P Brine 0 365
1988 EVERFLOW EASTERN PTNS L P Brine 309 365
1989 EVERFLOW EASTERN PTNS L P Brine 185 365
1990 EVERFLOW EASTERN PTNS L P Brine 139 365
1991 EVERFLOW EASTERN PTNS L P Brine 70 365
1992 EVERFLOW EASTERN PTNS L P Brine 0 365
1993 EVERFLOW EASTERN PTNS L P Brine 151 365
1994 EVERFLOW EASTERN PTNS L P Brine 122 365
1995 EVERFLOW EASTERN PTNS L P Brine 51 365
1996 EVERFLOW EASTERN PTNS L P Brine 70 365
1997 EVERFLOW EASTERN PTNS L P Brine 55 365
1998 EVERFLOW EASTERN PTNS L P Brine 67 365
1999 EVERFLOW EASTERN PTNS L P Brine 34 365
2000 EVERFLOW EASTERN PTNS L P Brine 24 365
2001 EVERFLOW EASTERN PTNS L P Brine 0 365
2002 EVERFLOW EASTERN PTNS L P Brine 12 365
2003 EVERFLOW EASTERN PTNS L P Brine 20 365
2004 EVERFLOW EASTERN PTNS L P Brine 0 365
2005 EVERFLOW EASTERN PTNS L P Brine 0 365
2006 EVERFLOW EASTERN PTNS L P Brine 0 365
2007 EVERFLOW EASTERN PTNS L P Brine 0 365
2008 EVERFLOW EASTERN PTNS L P Brine 0 365
2009 EVERFLOW EASTERN PTNS L P Brine 0 365
2010 EVERFLOW EASTERN PTNS L P Brine 0 365
2011 EVERFLOW EASTERN PTNS L P Brine 0 365
2012 EVERFLOW EASTERN PTNS L P Brine 0 276
2013 EVERFLOW EASTERN PTNS L P Brine 0 185
2014 EVERFLOW EASTERN PTNS L P Brine 0 95
2015 EVERFLOW EASTERN PTNS L P Brine 0 365
2016 EVERFLOW EASTERN PTNS L P Brine 0 365
2017 EVERFLOW EASTERN PTNS L P Brine 0 365
2018 EVERFLOW EASTERN PTNS L P Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
001216i609 2002-05-29 Production Wells No Violations Obtained GPS coordinates for the wellhead only. Unable to locate the tank battery at this time.
0102324873 2007-04-10 Production Wells No Violations I had Dave Claus give me his opinion on the tank battery that the Boardman fire departments had complained on. Dave also found no reason for a fence to go around tank battery or increase of the dikes. There were no violations at this time.
0710335322 2018-06-13 Production Wells No Violations The purpose of my inspection was to conduct a status check on well #2-2082. RBDMS indicated reported production was current. Well and tank battery access remained stable and drivable through a commercial parking lot. The well was located within a board on board fence enclosure that contained correct identification. The 8.625 well head was plumbed above grade and open to atmosphere. The 4.5 production casing was equipped with a plunger lift assembly. The master gate valve was closed. No leaks were observed. A stable earthen dike that was free of fluid was present around the production equipment. Mature evergreens and neighboring privacy shielded the equipment from view. Equipment on location consisted of one (1) horizontal separator The separator remained in good repair and contained correct identification. No violations were observed during this inspection.
1327392638 2004-03-19 Production Wells No Violations The tank battery consists of 1-25 bbl storage tank, 1-separator and a dike.
1562915824 2007-03-28 Production Wells No Violations This inspection was due to the Boardman Township Fire Departments request. Tank battery was GPSd. Tank battery had cedar fence around 2 sides of battery with the other 2 sides of pine trees. The battery had inside a mound of dirt 6 foot high. Talked to condo owner to the north of tank battery. She said she has heard of no complaints. ID sign posted. There were no violations at this time.

For data sources see[9]

References