If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 9: | Line 9: | ||
| State: Ohio | | State: Ohio | ||
|- | |- | ||
− | | County: | + | | County: <County> |
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[Milton Township,_Wayne_County,_Ohio|Milton Township]] |
|- | |- | ||
| Operator Name: [[MS PRODUCING LLC]] | | Operator Name: [[MS PRODUCING LLC]] |
Well ID: 34-169-25458 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.986610247,"lon":-81.84708597,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: Milton Township | |
Operator Name: MS PRODUCING LLC | |
Well Pad ID: | |
Farm/Lease Name: BOWMAN KENNETH L MARVIN # 3 | |
License Status: Producing | |
License Date: 2002-09-25 | |
Spud Date: 2002-10-12 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2002-10-19 | |
Well Total Depth: 5610 ft | |
Configuration: Vertical | |
Latitude: 40.986610247 | |
Longitude: -81.84708597 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2002-09-25 | Proposed Formations:KNOX, Issued Date:9/25/2002, Expired Date:9/25/2003 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:EDPW |
APP | 2002-10-09 | Proposed Formations:KNOX, Issued Date:10/9/2002, Expired Date:10/9/2003 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:EDPW |
Original Spud | 2002-10-11 | RBDMS Rec |
Correction to Well | 2002-10-18 | CORRECTION TO X, Y COORDINATES: X= 2,180,255 AND Y= 481,552. |
Reached Total Depth | 2002-10-19 | RBDMS Rec |
Completion Report Received | 2003-02-13 | RBDMS Rec |
Construction Permit Expires | 2003-09-25 | RBDMS Rec |
Change of Owner | 2013-01-07 | Operator changed from 265, CSAPO LIMITED to 8423, C & C PRODUCING LLC |
Change of Owner | 2018-01-10 | Operator changed from 8423, C & C PRODUCING LLC to 9842, MS PRODUCING LLC |
Record Last Modified | 2018-01-10 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2003-03-20 | 5562 | 5566 | 5 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 15 | 1000 Gal | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2003 | CSAPO LIMITED | 53388 | 1128 | 365 |
2004 | CSAPO LIMITED | 11618 | 570 | 365 |
2005 | CSAPO LIMITED | 3956 | 320 | 365 |
2006 | CSAPO LIMITED | 2899 | 263 | 365 |
2007 | CSAPO LIMITED | 1575 | 435 | 365 |
2008 | CSAPO LIMITED | 2151 | 279 | 365 |
2009 | CSAPO LIMITED | 1252 | 120 | 365 |
2010 | CSAPO LIMITED | 694 | 173 | 365 |
2011 | CSAPO LIMITED | 568 | 168 | 365 |
2012 | CSAPO LIMITED | 456 | 281 | 366 |
2013 | C & C PRODUCING LLC | 449 | 178 | 365 |
2014 | C & C PRODUCING LLC | 360 | 201 | 365 |
2015 | C & C PRODUCING LLC | 347 | 90 | 365 |
2016 | C & C PRODUCING LLC | 359 | 191 | 365 |
2017 | C & C PRODUCING LLC | 304 | 159 | 365 |
2018 | MS PRODUCING LLC | 332 | 88 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2003 | CSAPO LIMITED | Brine | 360 | 365 |
2004 | CSAPO LIMITED | Brine | 5 | 365 |
2005 | CSAPO LIMITED | Brine | 200 | 365 |
2006 | CSAPO LIMITED | Brine | 138 | 365 |
2007 | CSAPO LIMITED | Brine | 31 | 365 |
2008 | CSAPO LIMITED | Brine | 55 | 365 |
2009 | CSAPO LIMITED | Brine | 18 | 365 |
2010 | CSAPO LIMITED | Brine | 40 | 365 |
2011 | CSAPO LIMITED | Brine | 28 | 365 |
2012 | CSAPO LIMITED | Brine | 26 | 366 |
2013 | C & C PRODUCING LLC | Brine | 62 | 365 |
2014 | C & C PRODUCING LLC | Brine | 38 | 365 |
2015 | C & C PRODUCING LLC | Brine | 42 | 365 |
2016 | C & C PRODUCING LLC | Brine | 106 | 365 |
2017 | C & C PRODUCING LLC | Brine | 121 | 365 |
2018 | MS PRODUCING LLC | Brine | 62 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
001220i305 | 2002-10-23 | Production Wells | No Violations | Solidifing drilling pits in flood plain area. Service rig setting up over well. Rain 40 degrees. |
0027778774 | 2002-10-09 | Drill / Deepen / Reopen | No Violations | Called by Frank Csapo to inspect drilling pits in floodplain. Approved pit demensions of 6 depth and taper walls. Line pits with reenforced plastic liners. Pits are to be pumped, solidified and closed immediately after drilling the well. Location is being revised but Lat and Long readings are for new location. Sunny, dry 55 degrees. No tank battery demensions at this time. |
0029578786 | 2002-10-21 | Production Wells | No Violations | Flood plain location pumping drilling pits at this time. 60 degrees, sunny. Need pits solidified when fluid is removed. |
0166225462 | 2015-05-21 | Production Wells | No Violations | This pump jack well has no apparent problems or violations at this time. |
0191872725 | 2018-03-19 | Production Wells | No Violations | Inspected production well on 03/19/2018. The tank battery consists of 1-210 bbl steel tank, located within an earthen dike; 1-vertical separator and 1-meter box with a drip are located within a separate earthen dike nearby. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection. |
0239653299 | 2014-05-14 | Production Wells | No Violations | This pumping unit well appears to have no problems at time of inspection. |
0389961739 | 2017-06-05 | Production Wells | No Violations | Inspected production well on 06/05/2017. The tank battery consists of 1-210 bbl steel tank and 1-vertical separator, each located within separate earthen dikes. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection. |
0617569264 | 2017-06-05 | Preliminary Restoration | No Violations | Inspected production well on 06/05/2017. All drilling equipment and debris have been removed, pits closed, and the well placed into production. Preliminary restoration passes. |
0641312757 | 2015-11-02 | Production Wells | No Violations | Inspected production well on 11/02/2015. The tank battery consists of 1-210 bbl steel tank located within an earthen dike; 1-vertical separator is located nearby. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection. |
1245442573 | 2016-08-10 | Production Wells | No Violations | Inspected production well on 08/10/2016. The tank battery consists of 1-210 bbl steel tank and 1-vertical separator, each located within a separate earthen dike. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection. |
1446151399 | 2013-05-24 | Production Wells | No Violations | This pumping unit well appears to have no problems at this time. |
For data sources see[9]