Revision as of 17:50, 15 August 2019

Well Details

Well ID: 34-139-20089
Loading map...
Country: United States
State: Ohio
County: Richland
Municipality: Monroe Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: VAIL JESSIE W
License Status: Storage Well
License Date:
Spud Date: 1948-08-26
Spud Drilling Contractor:
Final Drill Date: 1948-10-06
Well Total Depth: 2410 ft
Configuration: Vertical
Latitude: 40.713815210
Longitude: -82.36968819

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1948-08-26 GL=1023.6
Completed 1948-10-06 GL=1023.6
Reached Total Depth 1948-10-06 GL=1023.6
Change of Owner 2011-10-18 Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION
Record Last Modified 2013-03-11 GL=1023.6

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2015-09-03 FOAM 0 10176 Gal 24200 C&J Energy Services The job utilized nitrogen assisted cross-linked gel fluid. 200 gallons of hydrochloric acid were pumped ahead of the fracture job. 80,200 cubic feet of nitrogen gas was used with the gel. No breakdown pressure was measured. At the end of the job the flow meter was giving abnormal readings which was caused by a blockage on the pump truck. No problems resulted from the flow meter issue. Proppant sand was 30/50 mesh instead of 20/40.

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0375701026 2016-12-07 Storage Well No Violations ID is posted and the location is maintained. The annulus is open. The well is equipped with a separator.
0495952798 2015-09-03 Storage Well No Violations The operator requested an inspection to witness fracture stimulation of the well. See the stimulation report for details.
1416006565 2017-12-05 Storage Well No Violations ID is posted and the location is maintained. The annulus is open. The well is equipped with a separator.
1544111076 2018-12-06 Storage Well No Violations Identification is posted and wellsite is maintained. Large separator on well. No observed violations at this time. Multiple domestic meters at this site.
1834792236 2015-12-01 Storage Well No Violations ID is posted and the location is maintained. The annulus is shut in.
1942408452 2014-03-19 Storage Well No Violations ID posted, location maintained.
2067934644 2019-04-03 Storage Well No Violations Identification is posted . Wellsite is maintained. Rural tap domestic meter at wellsite.

For data sources see[4]