Line 11: | Line 11: | ||
| County: [[Mahoning_County,_Ohio|Mahoning]] | | County: [[Mahoning_County,_Ohio|Mahoning]] | ||
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[Canfield_Township,_Mahoning_County,_Ohio|Canfield Township]] |
|- | |- | ||
| Operator Name: [[EVERFLOW EASTERN PTNS L P]] | | Operator Name: [[EVERFLOW EASTERN PTNS L P]] |
Well ID: 34-099-22640 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.039829562,"lon":-80.75170063,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Mahoning | |
Municipality: Canfield Township | |
Operator Name: EVERFLOW EASTERN PTNS L P | |
Well Pad ID: | |
Farm/Lease Name: CANFIELD BOYS BASEBALL UNIT | |
License Status: Producing | |
License Date: 1994-11-07 | |
Spud Date: 1994-12-03 | |
Spud Drilling Contractor: J & J DIRECTIONAL SERVICE | |
Final Drill Date: 1994-12-15 | |
Well Total Depth: 6376 ft | |
Configuration: Directional | |
Latitude: 41.039829562 | |
Longitude: -80.75170063 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1994-11-07 | 84 EVERFLOW EASTERN PTNS L P GeoDate 11/7/94 |
Oil and Gas | 1994-11-07 | Issued Date 11/7/94 Expired Date Acres 0063910 Tool Type RTAF Proposed Formation CLINTON Proposed Depth Proposed Drill Depth |
Original Spud | 1994-12-03 | |
Completed | 1994-12-15 | |
Reached Total Depth | 1994-12-15 | |
Completion Report Received | 1995-01-04 | |
Construction Permit Expires | 1995-11-07 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 5978 | 6132 | 0 |
2006-09-11 | 5993 | 6058 | 86 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 118670 Gal | 80000 | FRAC W/118,670 GAL WATER AND 80M# |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0000000867 | 2002-08-20 | Production Wells | No Violations | Obtained GPS coordinates. |
0000002164 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 9/18/95 INSPECTOR KEITH WHITE DATE 09/1819/95 DATA FROM OLD VAX INFO | |
0135415035 | 2018-08-14 | Production Wells | No Violations | The purpose of my inspection was to conduct a status check on well #2-2640. RBDMS indicated reported production was current. Access to the well remained drivable and stable. The well was located within a locked chain-link enclosure that contained correct identification. The 8.625 well head was above grade and open to atmosphere. The 4.5 production casing was equipped with a plunger lift assembly. Production valves were in the closed position. No leaks were observed. The tank battery was shared with 2-2641, 2645, 2673 and 2882. A stable earthen dike that was free of fluid was present around the equipment. A locked chain-link fence enclosure was constructed along the inner perimeter of the dike. Correct identification for all wells produced into the battery was present on the fence. Equipment on location consisted of five (5) horizontal separators and two (2) 100 bbl production tanks and two (2) 70 bbl production tanks. The separators remained in good repair and contained current 7 day production charts. The tanks remained in good repair. Valves were closed and plugged. The hatch lids were closed. No violations were observed during this inspection. |
1378546177 | 2004-02-11 | Production Wells | No Violations | The tank battery is shared with permits 2641, 2645, 2673 and 2882 and consists of 2-100 bbl storage tanks, 2-50 bbl salt water tanks, 5-separators, a dike and a fence. |
1583134095 | 2009-03-11 | Production Wells | No Violations | I performed a random field inspection. I GPSd both the tank battery and the wellhead. I continued to walk around both the tank battery and the wellhead and found both to be in good shape. There were no violations at this time. |