If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 11: | Line 11: | ||
| County: [[Mahoning_County,_Ohio|Mahoning]] | | County: [[Mahoning_County,_Ohio|Mahoning]] | ||
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[Canfield_Township,_Mahoning_County,_Ohio|Canfield Township]] |
|- | |- | ||
| Operator Name: [[ENERGY RESOURCES OF AMERICA IN]] | | Operator Name: [[ENERGY RESOURCES OF AMERICA IN]] |
Well ID: 34-099-22847 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.051032785,"lon":-80.79952597,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Mahoning | |
Municipality: Canfield Township | |
Operator Name: ENERGY RESOURCES OF AMERICA IN | |
Well Pad ID: | |
Farm/Lease Name: MAYLE RALPH & NAOMI | |
License Status: Producing | |
License Date: 1999-12-16 | |
Spud Date: 2000-01-14 | |
Spud Drilling Contractor: ADVENT DRLG | |
Final Drill Date: 2000-01-19 | |
Well Total Depth: 5261 ft | |
Configuration: Vertical | |
Latitude: 41.051032785 | |
Longitude: -80.79952597 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 1999-12-16 | Proposed Formations:CLINTON, Issued Date:12/16/99, Expired Date:12/15/00 6:00:00 AM, Drilling unit acres:48.5, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 2000-01-14 | RBDMS Rec |
Completed | 2000-01-19 | RBDMS Rec |
Reached Total Depth | 2000-01-19 | RBDMS Rec |
Completion Report Received | 2000-02-14 | RBDMS Rec |
Construction Permit Expires | 2000-12-15 | RBDMS Rec |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2000-05-24 | 5102 | 5212 | 59 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 100050 Gal | 60000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2000 | ENERGY RESOURCES OF AMERICA IN | 16970 | 191 | 301 |
2001 | ENERGY RESOURCES OF AMERICA IN | 12101 | 69 | 365 |
2002 | ENERGY RESOURCES OF AMERICA IN | 10137 | 0 | 365 |
2003 | ENERGY RESOURCES OF AMERICA IN | 8776 | 81 | 365 |
2004 | ENERGY RESOURCES OF AMERICA IN | 10516 | 0 | 365 |
2005 | ENERGY RESOURCES OF AMERICA IN | 6877 | 0 | 365 |
2006 | ENERGY RESOURCES OF AMERICA IN | 6372 | 54 | 365 |
2007 | ENERGY RESOURCES OF AMERICA IN | 5786 | 0 | 365 |
2008 | ENERGY RESOURCES OF AMERICA IN | 3884 | 28 | 365 |
2009 | ENERGY RESOURCES OF AMERICA IN | 3349 | 0 | 365 |
2010 | ENERGY RESOURCES OF AMERICA IN | 5219 | 0 | 365 |
2011 | ENERGY RESOURCES OF AMERICA IN | 4536 | 0 | 365 |
2012 | ENERGY RESOURCES OF AMERICA IN | 4920 | 0 | 366 |
2013 | ENERGY RESOURCES OF AMERICA IN | 3420 | 0 | 365 |
2014 | ENERGY RESOURCES OF AMERICA IN | 2263 | 0 | 365 |
2015 | ENERGY RESOURCES OF AMERICA IN | 0 | 0 | 365 |
2016 | ENERGY RESOURCES OF AMERICA IN | 29 | 0 | 365 |
2017 | ENERGY RESOURCES OF AMERICA IN | 0 | 0 | 365 |
2018 | ENERGY RESOURCES OF AMERICA IN | 0 | 0 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2000 | ENERGY RESOURCES OF AMERICA IN | Brine | 110 | 301 |
2001 | ENERGY RESOURCES OF AMERICA IN | Brine | 0 | 365 |
2002 | ENERGY RESOURCES OF AMERICA IN | Brine | 0 | 365 |
2003 | ENERGY RESOURCES OF AMERICA IN | Brine | 0 | 365 |
2004 | ENERGY RESOURCES OF AMERICA IN | Brine | 0 | 365 |
2005 | ENERGY RESOURCES OF AMERICA IN | Brine | 0 | 365 |
2006 | ENERGY RESOURCES OF AMERICA IN | Brine | 0 | 365 |
2007 | ENERGY RESOURCES OF AMERICA IN | Brine | 57 | 365 |
2008 | ENERGY RESOURCES OF AMERICA IN | Brine | 57 | 365 |
2009 | ENERGY RESOURCES OF AMERICA IN | Brine | 0 | 365 |
2010 | ENERGY RESOURCES OF AMERICA IN | Brine | 0 | 365 |
2011 | ENERGY RESOURCES OF AMERICA IN | Brine | 35 | 365 |
2012 | ENERGY RESOURCES OF AMERICA IN | Brine | 15 | 366 |
2013 | ENERGY RESOURCES OF AMERICA IN | Brine | 0 | 365 |
2014 | ENERGY RESOURCES OF AMERICA IN | Brine | 0 | 365 |
2015 | ENERGY RESOURCES OF AMERICA IN | Brine | 0 | 365 |
2016 | ENERGY RESOURCES OF AMERICA IN | Brine | 0 | 365 |
2017 | ENERGY RESOURCES OF AMERICA IN | Brine | 0 | 365 |
2018 | ENERGY RESOURCES OF AMERICA IN | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0080677508 | 2000-10-25 | Preliminary Restoration | No Violations | Meets requirements. |
0434043544 | 2012-02-17 | Production Wells | No Violations | FOLLOW UP TO NOV # 1329490908 - On 02/17/2012, DNR Inspector Richard Skidmore conducted a production well inspection for DNR Inspector Chris Grimm. My inspection found the identification sign was improperly marked with another permit number, County and Township location, and well owner name. There was a small gas leak coming from the plunger lift unit (rabbit). I immediately contacted Joe Glista (Energy Resources America) at his cell number (330-720-8137) to inform him of the issues with this well site. Joe said he would send out his well tender to repair the problems. A follow-up inspection will be conducted by 02/21/2012 to ensure compliance with state regulations. |
1329490908 | 2012-02-17 | Production Wells | Violations Noted | On 02/17/2012, DNR Inspector Richard Skidmore conducted an production well inspection. My inspection found the identification sign was improperly marked with another permit number, County and Township location, and well owner name. There was a small gas leak coming from the plunger unit (rabbit). I immediately contacted Joe Glista (Energy Resources America) at his cell number (330-720-8137) to inform him of the issues with this well site. Joe said he would send out his well tender to repair the problems. A follow-up inspection will be conducted by 02/21/2012 to ensure compliance with state regulations. |
1675487347 | 2008-01-02 | Production Wells | No Violations | I performed a random field inspection. GPSd both the tank battery and the well for the first time. The ID sign was posted. The tank battery was in good shape. There were no violations at this time. |
1776120983 | 2012-02-21 | Production Wells | No Violations | On 2/21/2012, DNR Inspector Richard Skidmore completed a production well followup inspection. The identification sign was corrected with the proper information, a bull plug was installed into a ball valve at the base of the storage tank, and the leak at the plunger lift was repaired, as specified from the initial status check on 2/17/2012. The lease road, well head, and tank battery locations are in compliance with 1501:9-9-05. Inspection passed. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1329490908 | US-OH-109431 | 2012-02-17 | Well insufficiently equipped to prevent escape of oil and gas | |
1329490908 | US-OH-109432 | 2012-02-17 | Failure to legibly identify well |