| County: [[Gallia_County,_Ohio|Gallia]] | | County: [[Gallia_County,_Ohio|Gallia]] | ||
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[Cheshire_Township,_Gallia_County,_Ohio|Cheshire Township]] |
|- | |- | ||
| Operator Name: [[WYANT EXPLORATION COMPANY]] | | Operator Name: [[WYANT EXPLORATION COMPANY]] | ||
Line 33: | Line 33: | ||
| Configuration: Vertical | | Configuration: Vertical | ||
|- | |- | ||
− | | Latitude: | + | | Latitude: 38.951431987 |
|- | |- | ||
| Longitude: -82.14389614 | | Longitude: -82.14389614 |
Well ID: 34-053-20783 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":38.951431987,"lon":-82.14389614,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Gallia | |
Municipality: Cheshire Township | |
Operator Name: WYANT EXPLORATION COMPANY | |
Well Pad ID: | |
Farm/Lease Name: OHIO POWER CO | |
License Status: Final Restoration | |
License Date: 2013-02-05 | |
Spud Date: 1982-10-02 | |
Spud Drilling Contractor: GARD DRILLING | |
Final Drill Date: 1982-10-06 | |
Well Total Depth: 1770 ft | |
Configuration: Vertical | |
Latitude: 38.951431987 | |
Longitude: -82.14389614 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1982-07-30 | 161 KRAMER EXPLORATION CO GeoDate 7/30/82 |
Oil and Gas | 1982-07-30 | Issued Date 7/30/82 Expired Date 1/15/83 Acres 0010000 Tool Type RTF Proposed Formation BEREA Proposed Depth 01770 Proposed Drill Depth 01770 |
Original Spud | 1982-10-02 | |
Completed | 1982-10-06 | |
Reached Total Depth | 1982-10-06 | |
Completion Report Received | 1982-11-09 | |
Change of Owner | 2009-12-18 | Operator changed from 161, KRAMER EXPLORATION CO to 8592, WYANT EXPLORATION COMPANY |
APP | 2013-02-05 | Proposed Formations:BEREA, Issued Date:2/5/2013, Expired Date:2/5/2015 12:00:00 PM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2013-08-08 | |
Construction Permit Expires | 2015-02-05 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 1704 | 1720 | 17 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1300 Bbl | 40000 | FRAC: 1300 BBL H20, 40M SAND |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0622331403 | 2015-06-16 | Final Restoration | No Violations | On my inspection I found that the location had been restored according to 1509.072. I passed the final restoration at this time. |
0669261784 | 2004-08-18 | Production Wells | No Violations | No violations |
0819279751 | 2014-04-24 | Plug / Plug Back | No Violations | Upon inspection, it was observed that this site is still largely bare. The pits were filled in. Surface casing was sticking approximately 2 out of the ground and cement could be seen at the top. I contacted Tim Wyant of Wyant Exploration Co. to discuss the restoration of this site, and he informed me that AEP waived the final restoration because they have plans to expand their landfill into the area where these wells were plugged. We do not have the landowner waiver on file. I will contact Tim Wyant again to see if he has a copy of this waiver. The restoration will not be passed until the waiver is approved. |
1381325972 | 2013-08-06 | Plug / Plug Back | No Violations | Huffman-Bowers was contracted by Wyant Exploration Co to plug this well at the request of AEP so AEP could expand their landfill operation in this area. Barry Bowers has expanded his well service operation to provide plugging services with service rig work at the well site. They showed up at 0830 hours and started to bring the 1-1/2 inch production tubing to surface. Tubing was tallied to ensure well depth at 1705-feet with a 16.1 feet mud anchor. Bowers bullhead the first plug over the Berea sand at 1720 to 1704 feet with 32 sacks of Class A neet cement. Shut well-in and shut down overnight to let plug set. |
1798192645 | 2013-08-07 | Plug / Plug Back | No Violations | Second day of plugging this well. Bowers crew set up wire line with mud joint on end to tag the top of yesterdays plug over the Berea sandstone. Top was at 1307-feet. Top of displaced water was at 27-feet below ground surface. This was the same location as yesterday and indicated a good plug was set. Ripped the 4-1/2 inch production casing at 1200-feet, their first telegraph point. Removed 35 joints of 4-1/2 inch casing. Ran 1-1/2 inch tubing to set the plug 100-feet in/ 100-feet out at the bottom of the 7-inch surface casing at 309-feet. Circulated 40 sacks of Class A neet cement over this interval. Removed tubing to set the top of the 7-inch plug from 100-feet to surface. Circulated 20 sacks of Class A neet cement through the 1-1/2 inch production tubing to plug this interval. Moved service rig to the next well location and left the cement pumper at this location to top off the top of the surface plug in the well if necessary. |
1961270046 | 2013-08-09 | Plug / Plug Back | No Violations | Arrived early to check status of the surface plug on this well. Bowers added more cement, 10 sacks to top off the surface casing yesterday. I observed that the top of the cement plug was 5-1/2 inches below the top of the 7-inch surface casing and it was hard. They had already dewatered the pit and covered it yesterday. The site was cleaned up and all equipment from the well was removed including the 4-1/2 inch production casing and the 1-1/2 inch tubing. |
For data sources see[9]