X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-133-24364"

m
m
Line 11: Line 11:
 
| County: [[Portage_County,_Ohio|Portage]]
 
| County: [[Portage_County,_Ohio|Portage]]
 
|-
 
|-
| Municipality: [[Kent City,_Portage_County,_Ohio|Kent City]]
+
| Municipality: [[Kent,_Ohio|Kent]]
 
|-
 
|-
 
| Operator Name: [[EOS ENERGY LLC]]
 
| Operator Name: [[EOS ENERGY LLC]]

Revision as of 03:02, 1 September 2019

Well Details

Well ID: 34-133-24364
Loading map...
Country: United States
State: Ohio
County: Portage
Municipality: Kent
Operator Name: EOS ENERGY LLC
Well Pad ID:
Farm/Lease Name: SCHOTERMAN A OR D UNIT
License Status: Producing
License Date: 2008-06-17
Spud Date: 2008-07-22
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2008-07-29
Well Total Depth: 4367 ft
Configuration: Vertical
Latitude: 41.145853857
Longitude: -81.32870712

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-06-17 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:6/17/2008, Expired Date:6/17/2009 6:00:00 AM, Drilling unit acres:50, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2008-07-22
Reached Total Depth 2008-07-29
Completion Report Received 2008-12-23
Construction Permit Expires 2009-06-17
Change of Owner 2018-07-31 Operator changed from 1249, CUTTER OIL COMPANY to 10185, EOS ENERGY LLC
Record Last Modified 2018-07-31

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-02-13 4142 4192 73

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 7 200 Mscf 70000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 CUTTER OIL COMPANY 0 169 100
2009 CUTTER OIL COMPANY 41176 724 365
2010 CUTTER OIL COMPANY 26708 334 365
2011 CUTTER OIL COMPANY 24410 239 365
2012 CUTTER OIL COMPANY 22479 194 366
2013 CUTTER OIL COMPANY 15774 97 365
2014 CUTTER OIL COMPANY 14067 91 365
2015 CUTTER OIL COMPANY 9701 0 365
2016 CUTTER OIL COMPANY 11431 107 365
2017 CUTTER OIL COMPANY 12133 188 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 CUTTER OIL COMPANY Brine 1980 100
2009 CUTTER OIL COMPANY Brine 471 365
2010 CUTTER OIL COMPANY Brine 356 365
2011 CUTTER OIL COMPANY Brine 145 365
2012 CUTTER OIL COMPANY Brine 225 366
2013 CUTTER OIL COMPANY Brine 117 365
2014 CUTTER OIL COMPANY Brine 172 365
2015 CUTTER OIL COMPANY Brine 248 365
2016 CUTTER OIL COMPANY Brine 103 365
2017 CUTTER OIL COMPANY Brine 296 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0417077795 2009-09-16 Preliminary Restoration No Violations Preliminary restoration is approved.
0706038603 2008-07-28 Drill / Deepen / Reopen No Violations Drilling will be completed today with logging and running production casing to follow. The rig should be moving off tomorrow.
0735910623 2008-09-17 Drill / Deepen / Reopen No Violations The well and tank battery have been fenced. The site has been graded and seeded. The well will be turned on as soon as the Dominion tap has been made. No violations at this time.
0957824327 2008-08-01 Drill / Deepen / Reopen No Violations Chemtech and Cutter Oil were on site to solidify the drilling pits.
1246869413 2018-11-27 UrbanProduction Wells No Violations Status check inspection of this Clinton Sandstone well. My inspection found the wellhead and tank battery fenced with board on board fencing and the man doors locked. The wellhead is equipped with 2.375 tubing and rods and is operating with the aid of an electric powered pumping unit. There is a domestic tap on the 4.5 production casing that is currently disconnected. This well produces to a diked tank battery on location containing two (2) 140 barrel tanks, a 35 barrel poly tank, and a horizontal separator. There is a Dominion Roots meter run inside the battery. The tank hatch lids are sealed and the tanks are vented through a 42 gallon charcoal filter. The required ID signage is posted at the wellhead and at the tank battery. No violations.
1342787641 2008-10-21 Production Wells No Violations The well is in production. The required fencing and identification are in place.
2129403864 2008-07-21 Drill / Deepen / Reopen No Violations Poulson Drilling is moving on site and will spud the well on 7/22. The working pits has been dug and lined and is being filled with fresh water. The sign is posted at the lease entrance and the fence around the pits will be installed as soon as the blow pit has been dug.

For data sources see[9]

References