If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-083-24545 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.26,"lon":-82.31,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Knox | |
Municipality: Clay Township | |
Operator Name: R & J WELL SERVICE LLC | |
Well Pad ID: | |
Farm/Lease Name: KIDWELL KEVIN | |
License Status: Producing | |
License Date: 2011-12-07 | |
Spud Date: 2011-12-14 | |
Spud Drilling Contractor: R & J DRILLING | |
Final Drill Date: 2013-07-20 | |
Well Total Depth: 784.00 ft | |
Configuration: Vertical | |
Latitude: 40.260000 | |
Longitude: -82.310000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2011-12-07 | Proposed Formations:BEREA, Issued Date:12/7/2011, Expired Date:12/6/2013 12:00:00 PM, Drilling unit acres:137.5, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2013-07-20 | |
Completion Report Received | 2013-09-15 | |
Construction Permit Expires | 2013-12-06 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
GEL | 0 | 80 Lbs | 0 |
For data sources see[3]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | R & J WELL SERVICE LLC | 0.00 | 15.00 | 180 |
2014 | R & J WELL SERVICE LLC | 0.00 | 15.00 | 250 |
2015 | R & J WELL SERVICE LLC | 0.00 | 0.00 | 0 |
2016 | R & J WELL SERVICE LLC | 0.00 | 15.00 | 250 |
2017 | R & J WELL SERVICE LLC | 0.00 | 15.00 | 365 |
2018 | R & J WELL SERVICE LLC | 0.00 | 15.00 | 250 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | R & J WELL SERVICE LLC | Brine | 0 | 180 |
2014 | R & J WELL SERVICE LLC | Brine | 0 | 250 |
2015 | R & J WELL SERVICE LLC | Brine | 0 | 0 |
2016 | R & J WELL SERVICE LLC | Brine | 0 | 250 |
2017 | R & J WELL SERVICE LLC | Brine | 0 | 365 |
2018 | R & J WELL SERVICE LLC | Brine | 0 | 250 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1060535955 | 2012-1-3 0:00:0 | DD | No Violations | |
-1182437581 | 2011-12-23 0:00 | DD | No Violations | |
-1867894267 | 2012-6-29 0:00: | DD | No Violations | |
-2146853501 | 2012-5-31 0:00: | DD | No Violations | |
-374966455 | 2012-1-6 0:00:0 | DD | No Violations | |
-555958284 | 2012-1-9 0:00:0 | DD | No Violations | |
-577218636 | 2012-7-10 0:00: | AM | No Violations | |
-746936560 | 2012-2-2 0:00:0 | DD | No Violations | |
0300526261 | 2012-07-05 | Drill / Deepen / Reopen | No Violations | I inspected this location today. No one was working during inspection. No work has been done on the pit. |
0374966455 | 2012-01-06 | Drill / Deepen / Reopen | No Violations | An inspection of drilling operations revealed driller, Dean Moran, at well location. 5.5 casing has been set and cement will be scheduled for next week. Instructed to provide notification. |
0379161010 | 2012-06-19 | Drill / Deepen / Reopen | No Violations | Today I inspected the well location. No one was working during inspection. Inspection revealed oil in the pit and the liner is not containing the oil. |
0555958284 | 2012-01-09 | Drill / Deepen / Reopen | No Violations | I witnessed the cementing of the surface casing today. |
0577218636 | 2012-07-10 | Administrative Inspection | No Violations | I made a phone call to Mr. Randy Moran today inquiring about the pit closure. He informed me that he did not want to remove the soil that came in contact with the oil and that he closed the pit in with a dozer. |
0678689782 | 2012-05-31 | Drill / Deepen / Reopen | Violations Noted | Jeff Fry accompanied me on this visit. Cable tool rig is on location. No one working at the time of inspection. The mud pit for the well has oil in it. The liner is not containing the oil in the pit. The fluid in the pit will need pumped out and the liner removed. Any soil that came in contact with the oil will need to be removed and taken off site. Inspection revealed there was no permit posted anywhere at the rig. |
0741013731 | 2012-01-17 | Drill / Deepen / Reopen | No Violations | An inspection of drilling operation revealed depth of 570. No violations were noted. |
0746936560 | 2012-02-02 | Drill / Deepen / Reopen | No Violations | An inspection revealed that this well has been drilled to total depth. The well is currently shut-in with a swage and valve palced on casing. No violations were noted. |
0789747561 | 2012-06-21 | Administrative Inspection | No Violations | I made a phone call to Mr. Randy Moran concerning the pit liner not containing oil in the pit. He informed me that Dean Moran still needs to clean out well and will need the pit. I informed Randy that soil will still need to be removed when finished with the pit. |
0927338913 | 2012-01-23 | Drill / Deepen / Reopen | No Violations | An inspection of drilling operations revealed no violations. The depth at time of inspection was 560 and approximately 16 from top of Berea. |
1060535955 | 2012-01-03 | Drill / Deepen / Reopen | No Violations | An inspection revealed no personnel or activity. 5.5 casing has been placed in wellbore. Notification was not received. |
1128091542 | 2012-07-09 | Drill / Deepen / Reopen | No Violations | I inspected this location today. No one was working. The inspection revealed that the pit had been closed and that the soil had not been removed. |
1182437581 | 2011-12-23 | Drill / Deepen / Reopen | No Violations | An inspection revealed no drilling activity or personnel at location. A GPS reading was obtained for the wellbore. |
1379002915 | 2013-09-11 | Production Wells | No Violations | This inspection was conducted as a NOV follow-up to NOV# 678689782. Jeff Fry accompanied me on this inspection. The pit has been closed. No contamination was observed during the inspection in or around the pit area. The violation has been resolved. |
1380137126 | 2013-09-20 | Preliminary Restoration | No Violations | This inspection was conducted as a NOV follow-up to NOV #1692506664. The inspection revealed that the rig and drilling equipment has been removed. The area around the well has been graded. No seed or straw. Identification has been posted on the pumping unit. Violations have been resolved. Preliminary restoration will be passed when vegetation/erosion control is established. |
1480454957 | 2012-07-06 | Drill / Deepen / Reopen | No Violations | I inspected this location today. No one was working during inspection. The pit was not closed and soil has not been removed. |
1692506664 | 2013-09-11 | Preliminary Restoration | Violations Noted | This inspection was conducted as a preliminary restoration status check. Jeff Fry accompanied me on this visit. The inspection revealed that the well is equipped with a pumping unit and motor. It was not pumping during inspection. The rig that was used to drill the well was rigged up on the well and other various parts of the rig were laying on the location. The area around the well has not been graded with a dozer. No identification was posted at the wellhead. According to ORC 1509.072 the owner is required to remove all drilling supplies and drilling equipment within two months after the date upon which the drilling of a well is completed. Also, as part of ORC 1509.072, the owner is required to grade or terrace and plant, seed, or sod the area disturbed that is not required in production of the well where necessary to bind the soil and prevent substantial erosion and sedimentation. Proper identification with the owner, permit number, well number, lease name, county, and an emergency phone number is required at the tank battery and each wellhead as multiple wells are being produced into a common tank battery. The owner will need to resolve these violations by 9/20/2013. Failure to comply may result in further enforcement action. Photos were taken for documentation purposes. |
1867894267 | 2012-06-29 | Drill / Deepen / Reopen | No Violations | I made a phone call to Mr. Randy Moran concerning the status of the pit closure. I extended the deadline for the pit to be closed and soil to be removed to 7/6/2012. I informed Randy that if the deadline is not met the contaminated soil will have to be hauled to an Ohio EPA approved landfill. |
1924676193 | 2012-06-28 | Drill / Deepen / Reopen | No Violations | During this visit my inspection revealed that the pit has been pumped out but the liner has not been removed. No one working during inspection. |
2134654971 | 2011-12-29 | Drill / Deepen / Reopen | No Violations | An inspection revealed no drilling activity or personnel. |
2146853501 | 2012-05-31 | Drill / Deepen / Reopen | Violations Noted | FOLLOW UP TO NOV # 678689782 Jeff Fry accompanied me on this visit. Cable tool rig is on location. No one working at the time of inspection. The mud pit for the well has oil in it. The liner is not containing the oil in the pit. The fluid in the pit will need pumped out and the liner removed. Any soil that came in contact with the oil will need to be removed and taken off site. Inspection revealed there was no permit posted anywhere at the rig. |
300526261 | 2012-7-5 0:00:0 | DD | No Violations | |
379161010 | 2012-6-19 0:00: | DD | No Violations | |
678689782 | 2012-5-31 0:00: | DD | No Violations | |
741013731 | 2012-1-17 0:00: | DD | No Violations | |
789747561 | 2012-6-21 0:00: | AM | No Violations | |
927338913 | 2012-1-23 0:00: | DD | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0678689782 | US-OH-127671 | 2012-06-01 | Drilling operation causing pollution and contamination | |
0678689782 | US-OH-127672 | 2012-06-09 | Failure to post permit | |
1692506664 | US-OH-116781 | 2013-09-25 | Failure to restore within six months | |
2146853501 | US-OH-122050 | 2014-04-10 | Drilling operation causing pollution and contamination |
For data sources see[8]