34-167-29658

Well Details

Well ID: 34-167-29658
Loading map...
Country: United States
State: Ohio
County: Washington
Municipality: Newport Township
Operator Name: OOGC DISPOSAL COMPANY 1 LLC
Well Pad ID:
Farm/Lease Name: LONG RUN DISPOSAL WELL(SWIW #8)
License Status: Active Injection
License Date: 2008-02-05
Spud Date: 2008-05-13
Spud Drilling Contractor: WARREN DRLG
Final Drill Date: 2008-05-22
Well Total Depth: 7246.00 ft
Configuration: Vertical
Latitude: 39.390000
Longitude: -81.310000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-02-05 Proposed Formations:CLINTON/MEDINA, Issued Date:2/5/2008, Expired Date:2/4/2009 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:SWD, Proposed Well Class:SWIW
Reached Total Depth 2008-05-22
Annulus Pressure Monitoring Approved 2008-08-07
Last Compliance Report 2008-10-15
Completion Report Received 2009-01-06
Construction Permit Expires 2009-02-04
Change of Owner 2015-11-24 Operator changed from 2153, OOGC DISPOSAL CO 1 LLC to 9503, OOGC DISPOSAL COMPANY 1 LLC
Record Last Modified 2015-11-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-02-24 6978 7042 218
2009-02-24 7120 7134 57
6978 7042 218
7120 7134 57
6978 7042 218

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2012-03-28 ACID 20 1200 Gal 0 Producers Service Corporation
H2O 0 48000 Gal 20000
H2O 0 52000 Gal 20000
2012-03-28 ACID 20 1200 Gal 0 Producers Service Corporation Yearly acidizing of disposal well - all went smooth.

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1009930694 2010-8-23 0:00: SW No Violations 0.70
-1025084211 2009-8-31 0:00: SW No Violations
-1031027108 2009-7-23 0:00: PL No Violations
-1178067936 2020-6-30 0:00: SW No Violations
-1332328564 2008-11-19 0:00 SW No Violations
-1400338893 2016-11-15 0:00 SW No Violations
-1430863003 2012-11-20 0:00 SW No Violations
-1449408671 2017-9-8 0:00:0 SW No Violations
-1477582439 2012-10-30 0:00 SW No Violations 4.50
-1480015238 2013-1-16 0:00: SW No Violations
-1530501340 2010-5-24 0:00: SW No Violations 1.00
-1554212147 2017-4-6 0:00:0 SW No Violations
-1565442962 2008-7-15 0:00: SW No Violations
-1699657349 2018-3-27 0:00: SW No Violations
-1795359153 2016-7-26 0:00: SW No Violations
-182746821 2008-8-21 0:00: SW No Violations
-1864530562 2018-2-16 0:00: SW No Violations
-1893203788 2008-7-24 0:00: SW No Violations
-2022594955 2012-8-23 0:00: SW No Violations
-325442367 2019-8-26 0:00: SW No Violations
-402575674 2008-7-28 0:00: SW No Violations
-411408206 2012-6-13 0:00: SW No Violations
-423092397 2019-9-30 0:00: SW No Violations
-443796612 2009-8-31 0:00: PL No Violations
-508920119 2008-6-2 0:00:0 DD No Violations
-626328716 2012-2-10 0:00: SW No Violations 0.70
-639076516 2014-6-16 0:00: SW No Violations
-660465936 2009-11-20 0:00 PW No Violations
-66582596 2015-6-8 0:00:0 SW No Violations
-667772071 2011-5-24 0:00: SW No Violations 0.70
-674622757 2009-2-12 0:00: SW No Violations
-767145449 2014-12-11 0:00 SW No Violations
-823111750 2017-2-1 0:00:0 SW No Violations
-844688922 2016-3-1 0:00:0 SW No Violations
0020272458 2014-04-10 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that pump house has been recently cleaned and organized.
0066582596 2015-06-08 Salt Water Injection Well No Violations Inspection revealed that well was in operation during my inspection and it was noted that 1/4 valves on annulus of tubing has been replaced since my last inspection.

Note: Creek crossing will need repaired in the near future.

0172349328 2016-12-06 Salt Water Injection Well No Violations Inspection revealed that injection pump to this well was in operation today.
0182746821 2008-08-21 Salt Water Injection Well No Violations Inspection this day due to complaint by landowner 1/4-1/2 mile south on Long Run Rd. ---10 on tab for chlorides. I do not feel the disposal well has anything to do with their well water problem - I think maybe they had pumped their well low and stirred up some sediment - well probably needs cleaned out. Will wait to hear from Cambridge lab and then call home owners. 9/2/2008 - Received water analyses from water wells. Called Mr. Seevers and Mr. Murphy and told them water did not show any brine, no chlorides or heavy metals. Investigation closed.
0199717251 2013-12-02 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.

Note: Storage tanks are located at the Bells Run Facility.

0226236489 2012-12-27 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.

Note: Pump house was clean and neat and floors were recently cleaned.

0245645025 2018-11-21 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.


1.1 SG

0372175993 2015-08-13 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation on the day of my inspection.
0382705366 2008-07-29 Salt Water Injection Well No Violations Inspection this day for testing of pipe integrity. Set A-3 Lock Set packer, unset packer to load hole. Circulation broke at 29 bbl. Circulated 62 bbl of corrosion inhibitor with 8 bbl going into pit, @ 2bbl left in tubing to cover packer. 30 bbl fresh water to load tubing. Reset packer. Pressured up to 1905# with pump truck. After 15 min., my gauge read 1850#. Passed test. Will start volume and rate testing tomorrow.
0402575674 2008-07-28 Salt Water Injection Well No Violations Ran A-3 Lock Set packer in well on 2 3/8 tubing to 6906 - Baker on location to supervise running of packer. Well set and pressure test next morning.
0411408206 2012-06-13 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.

Note: Curbing needs installed at pump house entrances to prevent any brine from leaving building it appears that when care taker washes out building that there is salt residue out on stone in front of building.

0443796612 2009-08-31 Preliminary Restoration No Violations Inspection this day found pumps running - all looks good. Reclamation has been done, grass growing.
0508920119 2008-06-02 Drill / Deepen / Reopen No Violations Inspection this day found drill pit has been squeezed down to about half. OOG representative out on locationn and reports A & R Energy has filed an injuction preventing further work until OOG gets a valid lease Crew out there today putting in temporary electric, water truck emptying frac tanks used for drilling. Water is being hauled.
0588227173 2014-08-14 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that two 1/4 valves on wellhead have been changed since my last inspection.
0626328716 2012-02-10 Salt Water Injection Well No Violations My inspection this day due to quarterly requirements. Pressure readings are taken off the company computer that is constantly monitoring the wells. Tubing pressure is 1940#, annulus is 430#. The pump is running this day. Identification as required. The operator reports no problems.
0639076516 2014-06-16 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.
0660465936 2009-11-20 Production Wells No Violations Inspection this day found no violations, small fence built around well, grass growing nicely. Pressures were 1700# tubing, 0# on annulus.
0663610721 2008-07-10 Salt Water Injection Well No Violations Inspection found service rig on location - were supposed to run packer on tubing and pressure test but having trouble with the well - cant get down the casing with tools, black, sticky substance coming out of well and took sample to be analyzed. Analysis back today says it is parafin - where coming from? Choices are dirty frac tanks or from formation, I would say. Waiting on plan to remove blockage and run tubing.
0667772071 2011-05-24 Salt Water Injection Well No Violations Inspection this day found pumps running, well taking water, flow being charted. Pump and location clean, good IDs. Tubing 1900#, annulus is 350#.
0674622757 2009-02-12 Salt Water Injection Well No Violations Quarterly inspection this day found no violations, pump running, good IDs, location still needs reclaimed but weather has not permitted - hopes to have done in next couple months, Bruce says. Also says water has been done some, last couple months.
0681028416 2009-05-27 Salt Water Injection Well No Violations Inspection this day found pump running, from location along the river. Reclamation stills needs finished up - ground has been smoothed but small pit still needs filled in, grass sown.
0757152930 2011-02-23 Salt Water Injection Well No Violations Inspection found no violations, pump at station running, pressures 1880#, 40# on annulus. Pressures are being tracted and monitored by computer, gate for house not closing easily.
0767145449 2014-12-11 Salt Water Injection Well No Violations Inspection revealed that well was in operation today and it was noted that company has winterized wellhead and associated plumbing coming from buried flow line.
0823111750 2017-02-01 Salt Water Injection Well No Violations Inspection revealed that injection pump to this well was in operation during my inspection.
0844688922 2016-03-01 Salt Water Injection Well No Violations Injection pump was in operation today.

Note: Two pen recorder needs to be recalibrated.

0863571910 2013-08-21 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.
1009930694 2010-08-23 Salt Water Injection Well No Violations Inspection this day found well in production, pump running. Pressure on tubing is 1820#, 0# on annulus. Good IDs, all looks good. Well is being charted.
1025084211 2009-08-31 Salt Water Injection Well No Violations Inspection this day found pumps running, well taking water. All looks good.
1031027108 2009-07-23 Preliminary Restoration No Violations Inspection this day found location has been reclaimed, completely finished and grass growing, no debris. Injection well.
1053242287 2010-11-22 Salt Water Injection Well No Violations Inspection this day found well hooked up to computer - no longer have a way to put my gauge on. Chart shows annulus and tubing pressure, also is being monitored thru computer at pump house. All looks good - pumphouse is spotless! Talked to T. Tomastic and he said fine if I use their computer readings for pressure.
1222789100 2008-10-06 Salt Water Injection Well No Violations On Friday, 9/26, service rig set up with Baker man and unhooked packer. Ran dye down tubing to try and determine where leaking - dye circulated with the conclusion that tubing had the leak, not the packer. Tubing was re-connected to packer and both were pulled, finishing up on 9/29/08. As tubing was pulled, found all the joints to be lose enough to leak, surprising as power tongs were used to tighten pipe. Also, several plastic collars used with the coated pipe were found in the tubing, some crushed, and coating on the pipe appears to be damaged. Also marks on packer indicating some rough treatment. New coated pipe was ordered. 10/2 Packer was run back in hole along with new coated pipe and collars. Tally on tubing that had come out of hole was off about 25 - maybe measured wrong or missed a joint. Baker man present to run packer back in and observe. 10/4 Pulled tubing and packer, 10/5- Ran tubing, packer back in, this time tightening joints over recommended limits, 10/6- Set packer, closed valve, tested tubing and annulus, both holding, circulated inhibitor, tested tubing again and started injecting.
1312378559 2011-08-02 Salt Water Injection Well No Violations
1322067122 2011-11-21 Salt Water Injection Well No Violations Inspection this day found no change in well or facility. Facility is clean, the integrity of pipe good, proper identification is posted, operational flowmeter and pressure gauge at well. Pressure readings were taken off computer at office.
1332328564 2008-11-19 Salt Water Injection Well No Violations Inspection this day found no one at well. Pump running, reclamation is being worked on and needs to be finished, not done yet, due to the weather, I believe. Pressure chart at well, good IDs, water coming thru pipeline from 2+ miles away - other well at this facility on the river where tanks, pump are located.
1386965570 2013-12-13 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation and it was noted that injection pump has been slowed down at request from Central Office.
1388100657 2013-12-23 Salt Water Injection Well No Violations On site with company personnel to test annulus of tubing they pressured up too 300# and we monitored pressure with a small leak detected within tubing head, bleed pressure off and tighten head and retested and it still leaked a little so decision was made to order new packing for tubing head and once packing comes in we will retest well.
1400338893 2016-11-15 Salt Water Injection Well No Violations Injection pump too this well was in operation today.
1405438296 2019-02-28 Salt Water Injection Well No Violations Inspection revealed that injection pump to this well was not in operation during my inspection.
1430863003 2012-11-20 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and well site was in satisfactory condition this inspection.
1436275155 2016-10-14 Salt Water Injection Well No Violations Inspection revealed that injection pump to this well was in operation during my inspection.
1447494134 2010-02-24 Salt Water Injection Well No Violations Inspection this day found no violations, pumps running and this well taking water at 1675# on tubing, 0 on annulus.
1449408671 2017-09-08 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.
1450657412 2018-07-19 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.
1453617165 2008-07-31 Completion Testing No Violations Inspection this day found crew doing flow testing. Well injecting at 56 bbl/hour at 1200# - water being trucked into tanks on location - short piece of line connecting well to tanks. Pipeline not completed yet.
1475059360 2008-07-16 Surface Facility Construction No Violations Called out today as they are ready to pump saltwater into the temporary pit at the oil gathering facility. Heavy plastic liner has been hot-welded together to prevent leaks - water will start going in 7/17/2009 - they will have 120 days.
1477582439 2012-10-30 Salt Water Injection Well No Violations I met today with Tim Leftwich & Doug Aden, OGS and Glenda Besana-Ostman, DNR- UIC, to show them possible good sites for further seismic monitors. We discussed the requirements needed for a good site and I showed them one outside Newport, located between 2 soon-to-be approved new disposal wells and they installed one of the units this day. Also showed them several other sites (one of which is near this well) to choose from for monitors they will bring in following weeks.
1480015238 2013-01-16 Salt Water Injection Well No Violations Inspection on this day revealed that injection pumps were in operation and found pump house clean and neat and facility appears to be in satisfactory condition this inspection.
1510999919 2017-11-15 Salt Water Injection Well No Violations Inspection revealed that injection pump to this well was in operation on the day of my inspection.
1527438315 2018-05-27 Salt Water Injection Well No Violations Inspection today revealed that injection pumps were in operation during my inspection.


Note: 2 valve on tubing head will need to be replaced in the near future its getting hard to open and 1/4 valve needs to be replaced also.

1530501340 2010-05-24 Salt Water Injection Well No Violations Inspection this day found pump running, pressure on well. Good IDs, no violations.
1549716940 2018-01-09 Salt Water Injection Well No Violations Inspection revealed that injection pump to this well was in operation today.
1554212147 2017-04-06 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation during my inspection.
1564243424 2019-7-22 0:00: SW No Violations
1565442962 2008-07-15 Salt Water Injection Well No Violations Rig crew on location, getting ready to leave. Waiting on orders, was told a parafin block in 4.5 casing, rental tubing on location and will go in with small bit and drill out blockage - well flowing this day so are not going to work on it. Water getting around this blockage so not solid, my idea to go in with solvent, let set and see if that doesnt take care of it. Hopefully, can run packer 7/21/2008.
1621469158 2008-09-08 Salt Water Injection Well No Violations Met with Bruce Phipps of OOG regarding tubing leak. Well showed 600# on tubing, 600# on casing, and had been shut down since Friday (9/5/08). Talked to Tom Tomastik to get his opinion, then shut well down until tubing leak fixed. Service rig could have been on location today but Baker who operates packer could not get there for 2 weeks, Tom Roberts reports.
1625873439 2012-12-12 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and pump house was clean and tidy this inspection.

Note: Lease road to wellhead is in need of grade work preformed.

1699657349 2018-03-27 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.
1701304756 2008-08-18 Salt Water Injection Well No Violations First inspection since pipeline has been completed and are injecting water from their facility along the river, not tanks on location which they were temporarily hauling into. Tubing pressure 1400#, annulus pressure 800#. Still need IDs. Location has not been reclaimed. Operator reports tubing or packer is leaking - they think tubing and have rig scheduled for 8/25/08 to pull and find problem.
1701853248 2020-4-20 0:00: SW No Violations
1712979403 2016-06-06 Salt Water Injection Well No Violations Inspection revealed that injection pump to this well was in operation during my inspection.
172349328 2016-12-6 0:00: SW No Violations
1726141211 2016-09-06 Salt Water Injection Well No Violations Injection pump too this well was in operation during my inspection.
1776054022 2013-04-30 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.

Note: 2 nipple on injection line is showing signs of needed replacement and also high pressure hose going to meter box is showing signs of fatigue.

1795359153 2016-07-26 Salt Water Injection Well No Violations Inspection revealed that injection pump to this well was in operation today.
1864530562 2018-02-16 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 4th quarter of 2017 . Please submit the appropriate reports by March 17, 2018. FEES AND REPORTS RECEIVED 3/9/2018
1893203788 2008-07-24 Salt Water Injection Well No Violations Inspection this day found service rig circulating on hole thru the bit and 2 7/8 casing. Got back down to bottom, will come out and start running coated pipe with packer on Monday morning. Well perfd at 6978-7134 - blockage had been at 6405 - they believed it to be paraffin. Pressure test late Monday or Tues. morning.
1978567385 2017-07-24 Salt Water Injection Well No Violations Inspection today indicated that injection pump to this well was in operation during my inspection.
199717251 2013-12-2 0:00: SW No Violations
2022594955 2012-08-23 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was discussed that small leak on injection pump would be fixed by the end of the day.
20272458 2014-4-10 0:00: SW No Violations
226236489 2012-12-27 0:00 SW No Violations
245645025 2018-11-21 0:00 SW No Violations
311138971 2019-12-3 0:00: SW No Violations
372175993 2015-8-13 0:00: SW No Violations
382705366 2008-7-29 0:00: SW No Violations
588227173 2014-8-14 0:00: SW No Violations
663610721 2008-7-10 0:00: SW No Violations
681028416 2009-5-27 0:00: SW No Violations
757152930 2011-2-23 0:00: SW No Violations 0.70
863571910 2013-8-21 0:00: SW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1864530562 US-OH-118676 2018-03-21 NONE Failure to report disposal fees

For data sources see[5]