If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-029-21657 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.82,"lon":-81.03,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Columbiana | |
Municipality: Knox Township | |
Operator Name: NORTH AMERICAN PETROLEUM INC | |
Well Pad ID: | |
Farm/Lease Name: WILLIAMS | |
License Status: Producing | |
License Date: 2007-11-30 | |
Spud Date: 2007-12-04 | |
Spud Drilling Contractor: ADVENT DRLG | |
Final Drill Date: 2007-12-09 | |
Well Total Depth: 5723.00 ft | |
Configuration: Vertical | |
Latitude: 40.820000 | |
Longitude: -81.030000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2007-11-30 | Proposed Formations:CLINTON, Issued Date:11/30/2007, Expired Date:11/29/2008 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2007-12-09 | |
Construction Permit Expires | 2008-11-29 | |
Completion Report Received | 2009-03-09 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2009-06-05 | 5501 | 5569 | 25 |
5501 | 5569 | 25 | |
5501 | 5569 | 25 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 7 | 105000 Gal | 80000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | NORTH AMERICAN PETROLEUM INC | 4129.00 | 494.00 | 365 |
2009 | NORTH AMERICAN PETROLEUM INC | 13649.00 | 347.00 | 365 |
2010 | NORTH AMERICAN PETROLEUM INC | 12124.00 | 444.00 | 365 |
2011 | NORTH AMERICAN PETROLEUM INC | 11168.00 | 94.00 | 365 |
2012 | NORTH AMERICAN PETROLEUM INC | 8556.00 | 233.00 | 366 |
2013 | NORTH AMERICAN PETROLEUM INC | 6850.00 | 205.00 | 306 |
2014 | NORTH AMERICAN PETROLEUM INC | 7038.00 | 122.00 | 60 |
2015 | NORTH AMERICAN PETROLEUM INC | 4909.00 | 158.00 | 365 |
2016 | NORTH AMERICAN PETROLEUM INC | 3365.00 | 0.00 | 172 |
2017 | NORTH AMERICAN PETROLEUM INC | 5545.00 | 208.00 | 249 |
2018 | NORTH AMERICAN PETROLEUM INC | 3502.00 | 88.00 | 249 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | NORTH AMERICAN PETROLEUM INC | Brine | 320 | 365 |
2009 | NORTH AMERICAN PETROLEUM INC | Brine | 120 | 365 |
2010 | NORTH AMERICAN PETROLEUM INC | Brine | 140 | 365 |
2011 | NORTH AMERICAN PETROLEUM INC | Brine | 50 | 365 |
2012 | NORTH AMERICAN PETROLEUM INC | Brine | 0 | 366 |
2013 | NORTH AMERICAN PETROLEUM INC | Brine | 0 | 306 |
2014 | NORTH AMERICAN PETROLEUM INC | Brine | 365 | 60 |
2015 | NORTH AMERICAN PETROLEUM INC | Brine | 0 | 365 |
2016 | NORTH AMERICAN PETROLEUM INC | Brine | 0 | 172 |
2017 | NORTH AMERICAN PETROLEUM INC | Brine | 0 | 249 |
2018 | NORTH AMERICAN PETROLEUM INC | Brine | 0 | 249 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1880572909 | 2017-11-1 0:00: | PW | No Violations | 0.70 |
-1951983057 | 2007-12-26 0:00 | CT | No Violations | 1.00 |
-754412503 | 2008-10-21 0:00 | PL | No Violations | 0.50 |
-852737122 | 2017-11-21 0:00 | PW | No Violations | 0.20 |
0417235479 | 2017-11-30 | Production Wells | No Violations | The purpose of my inspection was to document repairs to well #2-1657. Lease operator AJ Strawn reported that he had replaced parts of the well head flow line that had caused fluid to leak onto the ground. At the time of my inspection I observed that the well head assembly had been repaired and the ground area cleaned up. No additional leaks were observed. No further action is necessary. |
0754412503 | 2008-10-21 | Preliminary Restoration | No Violations | Inspection revealed that the preliminary restoration can be approved at this time. No violations at this time. |
0852737122 | 2017-11-21 | Production Wells | No Violations | The purpose of my inspection was to document the status of repair of a well head leak at well #2-1657. At the time of my inspection the source of the leak had not been repaired. I called and spoke with Rick Betta while on location. Mr. Betta reported that he had spoke with the lease operator and directed him to make repairs. Mr. Betta continued that he would contact the operator again to make the repair. I later received a voice mail from lease operator AJ Strawn to report that he had replaced the leaking nipple on the well head flow line. I will schedule a follow up inspection to document the repair. |
1880572909 | 2017-11-01 | Production Wells | No Violations | The purpose of my inspection was to conduct a status check inspection on well #2-1657. Production was current. The access and locations were stable. Correct identification was present. The 8.625 well head was above grade. The 4.5 production casing was equipped with a plunger lift assembly. A tubing pressure gauge indicated 350 psi. Production valves were in the open position. The U-tube assembly had a small leak that was collecting on the ground. A domestic supply connection was present. The tank battery consisted of one (1) horizontal separator, one (1) 140 bbl production tank and one (1) 50 bbl brine tank. A stable earthen dike that was free of fluid was constructed around the equipment. The separator remained in good repair and contained a current 16 day chart. The production tank remained in good repair and contained correct identification. Valves were closed and plugged. The brine tank remained in good repair. The hatch lid was open. Some staining was observed on the ground at the tank base. The staining was not live or fresh. I will contact the owner to make repairs to the well head flow line. I called and spoke with Rick Betta who stated that he would have an operator out to repair the leak. I will schedule a follow-up inspection to confirm the leak was repaired. |
1951983057 | 2007-12-26 | Completion Testing | No Violations | Inspection of the drilling pits revealed that the pit liners are intact and the fluid levels are acceptable. Inspection also revealed that they are grading the leaseroad . No violations at this time. |
417235479 | 2017-11-30 0:00 | PW | No Violations | 0.20 |
For data sources see[9]