X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-029-21727

Well Details

Well ID: 34-029-21727
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Middleton Township
Operator Name: CHESAPEAKE EXPLORATION LLC
Well Pad ID: US-OH-000402
Farm/Lease Name: CARNEY 17-7-1
License Status: Plugged Back
License Date: 2012-04-02
Spud Date: 2012-04-15
Spud Drilling Contractor: NOMAC DRILLING CORP
Final Drill Date: 2012-05-02
Well Total Depth: 8845.00 ft
Configuration: Vertical
Latitude: 40.770000
Longitude: -80.600000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2012-03-30 Proposed Formations:POINT PLEASANT, Issued Date:3/30/2012, Expired Date:3/30/2014 12:00:00 PM, Drilling unit acres:153.4, Proposed Well Type:OG, Proposed Well Class:EDPW
APP 2012-04-02 Proposed Formations:TRENTON - BLACK RIVER, Issued Date:4/2/2012, Expired Date:4/2/2014 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
Reached Total Depth 2012-05-02
Completion Report Received 2012-06-27
End of Confidential Data 2013-05-02
Construction Permit Expires 2014-04-02
Record Last Modified 2015-07-01

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2014-09-09 8909 13446 320
8909 13446 320
8909 13446 320

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 07/20/2012 07/20/2012 8570.00 3,716,076.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 ALPHA 1427 Baker Hughes Antibacterial Agent Didecyl dimethyl ammonium chloride 7173-51-5 10.00 0.00134000
Ethanol 64-17-5 5.00 0.00067000
Glutaraldehyde 111-30-8 30.00 0.00402000
Quaternary ammonium compounds,

benzyl-C12-16-alkyldimethyl, chlorides

68424-85-1 7.00 0.00094000
Water 7732-18-5 60.00 0.00804000
BF-9L Baker Hughes pH Adjusting Agent Potassium hydroxide 1310-58-3 15.00 0.00557000
BF-9L, CI-14, ENZYME G-NE, FERROTROL

300L, FRW-18, GBW-15L, GW-3LDF, SCALETROL 720

Baker Hughes Breaker, Corrosion Inhibitor, Friction Reducer, Gelling Agent, Iron Control Agent, pH Adjusting Agent, Scale Inhibitor Hemicellulase Enzyme Concentrate 9025-56-3
Proprietary Surfactant
Proprietary Polymer
Proprietary Solvent
Calcium chloride 10043-52-4
Proprietary Biocide
Proprietary Enzyme
Proprietary Copolymer
Proprietary Alcohol
Proprietary Disinfectant
Water 7732-18-5
Proprietary Silica
Proprietary Acid
Proprietary Weak Acid
100 Mesh Sand Proppant Quartz 14808-60-7 100.00 2.64
CI-14 Baker Hughes Corrosion Inhibitor Methanol 67-56-1 68.00 0.00096000
Propargyl alcohol 107-19-7 5.00 0.00007000
FRW-18 Baker Hughes Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.01
SCALETROL 720 Baker Hughes Scale Inhibitor Ethylene glycol 107-21-1 35.00 0.00516000
Diethylene glycol 111-46-6 5.00 0.00074000
Additional Ingredients Not Listed on MSDS
Recycled Produced Water Carrier/Base Fluid 9.23
XLW-32 Baker Hughes Crosslinker Boric acid 10043-35-3 20.00 0.00491000
Methanol 67-56-1 90.00 0.02
GW-3LDF Baker Hughes Gelling Agent Petroleum Distillate Blend 60.00 0.12
Polysaccharide Blend 60.00 0.12
Ottawa Sand Proppant Quartz 14808-60-7 100.00 12.18
FERROTROL 300L Baker Hughes Iron Control Agent Citric acid 77-92-9 50.00 0.00097000
FRW-18 Hughes Friction Reducer
Fresh Water Carrier/Base Fluid 74.92
ClayCare Baker Hughes Clay Stabilizer Water 7732-18-5 30.00 0.01
Choline chloride 67-48-1 75.00 0.03
ENZYME G-NE Baker Hughes Breaker No Hazardous Components 0.00
GBW-15L Baker Hughes Breaker Sodium chloride 7647-14-5 100.00 0.02
Hydrochloric Acid 10.1-15 Baker Hughes Acid Hydrochloric acid 7647-01-0 15.00 0.08
Water 7732-18-5 85.00 0.49

For data sources see[4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2016 GEOPETRO LLC Brine 0 0
2019 GEOPETRO LLC Brine 0 0

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1072978957 2016-12-6 0:00: PW No Violations 1.00
-1396742135 2020-3-23 0:00: PB No Violations 1.00
-1557401513 2018-9-19 0:00: PW No Violations 0.50
-1605547817 2016-6-22 0:00: PW No Violations 2.50
-1820283607 2018-11-13 0:00 PW No Violations 0.40
-830629787 2016-3-4 0:00:0 PW No Violations 0.70
0830629787 2016-03-04 Production Wells No Violations I was on location for a status check. My inspection found the access road gate locked and the access road in good repair. The pad is fenced and all man doors were locked. An identification sign is posted at the access road entrance and well. The #3H is not in production. The well is equipped with a christmas tree valve assembly.

The equipment on the pad consists of the following:

Site fenced and man doors locked

0877353489 2014-12-11 Preliminary Restoration No Violations

-established ground cover. The soil stockpile is well stabilized with vegetation. Crops, woodlands and/or underbrush are growing normally outside the area of disturbance. Drainage and erosion controls outside the pad are in place and functioning. A closed-loop, above-

1072978957 2016-12-06 Production Wells No Violations The purpose of my inspection was to conduct a status check on well #2-1727-01. The well is currently in temporary inactive status. The new owner has corrected well identification present at the entrance and well head. Lease access and the well pad facilities remain in good repair. No other equipment is on the pad. The Owner raised and identified the 9.625 intermediate annular casing pressure gauge and the 5.5 production annular casing pressure gauge. The intermediate annular casing gauge indicated 0 psi. The production casing annular gauge indicated 160 psi. The 9.625 intermediate casing seat is set at 2870 Maximum allowable annular surface pressure (MAASP) at the surface per ORC 1501:9-1-08 (N) (2) is 869 psi. The production casing valve was closed. The production casing and tubing pressure gauges indicated 0 psi. I will continue to monitor casing pressures on a regular basis to ensure compliance.
1097332322 2017-07-13 Production Wells Violations Noted The purpose of my inspection was to conduct a status check on well #1727-01. Correct signage remained posted at the entrance. The access road remained in good repair. No evidence of accelerated erosion or sedimentation was present along the road. The pad was enclosed by a locked chain-link fence perimeter. The fence remained in good repair with no signs of vandalism. An earthen berm perimeter was present outside of the fencing. I walked the perimeter of the pad and found no evidence of erosion or sedimentation. The pad was composed of crushed gravel that remained in good repair. A jersey barrier perimeter was present around the well head. Correct signage was present on the well head. Annular pressure gauges were identified. The 13.375 annular gauge identified 0 psi. The 9.625 annular gauge identified 155 psi. The 5.5 production casing gauge identified 0 psi. The tubing gauge identified 0 psi. No audible or visual leaks were detected. The second year inactive status permit issued to Chesapeake on 6/3/2016 expired 6/3/2017. At the time of inspection a valid third year temporary inactive status permit has not been issued. The well has no reported production for eight consecutive reporting periods as reported in accordance with section 1509.11. The Owner shall plug the well in accordance with section 1509.12 of the Revised Code, obtain temporary inactive well status in accordance 1509.062, or perform another activity regarding the well that is approved by the chief of the division of oil and gas resources management.
1159224840 2015-03-11 Production Wells No Violations

-established ground cover. The soil stockpile is well stabilized with vegetation. Drainage and erosion controls at the pad are in place and functioning. I emailed Steve Ault of Chesapeake on 4/24/2015 about the identification signs. He replied on 4/27/2015 that they had located the wellhead identification signs and they would be installed within the week. I recommend temporary inactive status be granted.

1557401513 2018-09-19 Production Wells No Violations The purpose of my inspection was to document the status of well #2-1727-01. The current temporary inactive status permit was issued on 8/14/2017. At the time of my inspection the identification sign at the entrance was lying on the ground. Access to the well pad remained stable and drivable. Mature vegetation was established in the erosion and sedimentation controls. The pad perimeter security fence remained in good repair. The cut and fill slopes remained stable. Correct identification remained in place at the well head. A perimeter of jersey barriers were in place around the well head. Steel grating remained in place over the cellar to prevent falls. The cellar contained freshwater. I did not witness any evidence of leaking. The annular gauges were plumbed above grade and labeled. The intermediate casing annular gauge indicated 0 psi. The production casing annular gauge indicated 150 psi. The well head was equipped with a production tree. All valves remained closed. A chain was placed through all of the valves and locked. The production casing annular gauge indicated 150 psi. The production casing gauge indicated 650 psi. The tubing gauge on top of the production tree indicated 4100 psi. No other equipment was on location. While on location I called the Geopetro office to report the condition of the entrance sign and to request it be repaired. I will schedule a follow-up inspection to document the status of the sign.
1605547817 2016-06-22 Production Wells No Violations My purpose for inspection was to conduct a second year temporary inactive well status inspection.

There is one well on the pad. The sign board posted at the lease entrance displayed signs with the well name, address, permit number and emergency contact information. The lease road was graveled and in good repair with a gate at Vale Road. Erosion and sedimentation controls were in place and ground cover was well established along the road. I walked the entire location and found the well pad constructed with an earthen berm perimeter in good repair, being stabilized with well-established vegetation. Erosion and sedimentation controls are in place and functioning. The well pad was found to be enclosed by a chain link fence with barbed wire at the top. The primary entrance and escape doors were found locked. The surface of the well pad consists of gravel and is in good repair. Soil stockpile is stabilized with well-established vegetation. The Carney 3H was constructed with 120 of 20 conductor, 835 of 13 3/8 surface casing, 2869 of 9 5/8 intermediate casing and 13596 of 5 1/2 production casing. Drilling was completed 5/5/2012. The well was stimulated 7/20/2012 and completed with 8183 of 2 7/8 tubing. The well head was constructed with a Christmas tree valve assembly and found to be protected by steel cattle gates further protected by concrete Jersey barriers. Proper well identification signage was displayed. A cellar grate was in place to prevent falls. The cellar contained water with approximately 5 feet of freeboard. The pressure gaugse on the production casing, intermediate casing, and surface casing all indicated 0 psi. No sheen or leaking gas was observed on the water in the cellar. The mousehole was cemented. Gate valves are chained and locked. No other production equipment is on the pad. I recommend that the pressures associated with the respective casing strings be tested and documented with an ODNR DOGRM Inspector present as a

1820283607 2018-11-13 Production Wells Violations Noted The purpose of my inspection was to document the status of the well site entrance sign. At the time of my inspection, a mature tree was positioned across the entrance that prevented access to the well location. The entrance sign remained on the ground. I walked back to the well pad and found the perimeter security fence in good repair. I did not witness any other signs of vandalism. While on location I called the Geopetro office and spoke with the receptionist. I stated the reason for my call and indicated that I would be issuing a compliance notice due to the sign not being repaired after my previous inspection and phone call on 9/19/2018 (Inspection # 1557401513). The receptionist stated that she would have the field superintendent call back to discuss the situation. I will schedule a follow-up inspection to document the status of repairs.
1852752306 2018-11-20 Production Wells No Violations The purpose of my inspection was to follow-up on compliance notice # 1820283607. I had spoke with owner representative Andy Iezzi on 11/15/2018. Mr. Iezzi reported that the entrance sign was repaired and that he had updated emergency phone number stickers that would be installed when weather conditions were favorable. He also reported that the land owner had placed the tree across the entrance road due to trespassers. At the time of my inspection I found the entrance sign standing. The emergency phone number was not updated. I met with the surface owner, Mr. Carney, who confirmed trespassers had been leaving trash on the road at various times and had likely vandalized the entrance sign. I will follow-up with Mr. Iezzi in a few weeks to confirm the emergency number is updated. No further action is necessary at this time.
877353489 2014-12-11 0:00 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1097332322 US-OH-102323 2018-01-23 NONE16 Temporary inactive; failure to comply with terms or conditions of the permit, rules, or orders
1820283607 US-OH-118178 2018-11-28 9-9-05(A)10 Failure to legibly identify well

For data sources see[7]

References