34-029-21737

Well Details

Well ID: 34-029-21737
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Salem Township
Operator Name: EAP OHIO LLC
Well Pad ID: US-OH-000347
Farm/Lease Name: RIFFLE 21-15-3
License Status: Producing
License Date: 2012-06-14
Spud Date: 2012-10-07
Spud Drilling Contractor: NOMAC DRILLING CORP
Final Drill Date: 2012-10-29
Well Total Depth: 12835.00 ft
Configuration: Horizontal
Latitude: 40.840000
Longitude: -80.810000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2012-06-14 Proposed Formations:POINT PLEASANT, Issued Date:6/14/2012, Expired Date:6/14/2014 12:00:00 PM, Drilling unit acres:129.5, Proposed Well Type:OG, Proposed Well Class:EDPW
Reached Total Depth 2012-10-29
Correction to Well 2013-03-22 CORRECTION TO TARGET INFORMATION: FOOTAGE AND X,Y COORDINATES FROM AS DRILLED SURVEY PLAT. UNIT SIZE CHANGED TO 114 ACRES.
End of Confidential Data 2013-10-29
Construction Permit Expires 2014-06-14
Completion Report Received 2014-08-22
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2014-06-06 8608 12680 280
8608 12680 280
8608 12680 280

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 11/14/2012 11/14/2012 7773.00 3,170,790.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 CI-150 (Corrosion Inhibitor) FTS International Corrosion Inhibitor Isopropanol 67-63-0 60.00 0.00066000
Proprietary Aromatic Aldehyde 10.00 0.00011000
N,N-Dimethylformamide 68-12-2 10.00 0.00011000
Proprietary Organic Amine Resin Salt 30.00 0.00033000
Proprietary Quaternary Ammonium Compound 10.00 0.00011000
MC B-8642 (WS) Multi-Chem Group Antibacterial Agent Quaternary ammonium compounds,

benzyl-C12-16-alkyldimethyl, chlorides

68424-85-1 10.00 0.00211000
Glutaraldehyde 111-30-8 60.00 0.01
Ethanol 64-17-5 1.00 0.00021000
100 Mesh Sand FTS International Proppant - Natural Quartz 14808-60-7 100.00 1.43
FRW-200 FTS International Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 26.00 0.01
FE 200 FTS International Iron Control Agent Ethylenediaminetetraacetic acid tetrasodium salt hydrate 64-02-8 41.00 0.00165000
Sodium hydroxide 1310-73-2 1.90 0.00008000
Glycine, N,N-bis(carboxymethyl)-, trisodium salt 5064-31-3 2.00 0.00008000
B10 (HIGH PH BUFFER) FTS International pH Adjusting Agent Potassium hydroxide 1310-58-3 20.00 0.00119000
Carbonic acid, dipotassium salt 584-08-7 48.00 0.00285000
NaturaLine MX 588-2 Multi-Chem Group Scale Inhibitor No Hazardous Components 0.00
APB-01 Ammonium Persulfate Breaker FTS International Breaker Peroxydisulfuric acid, diammonium salt 7727-54-0 100.00 0.00140000
Borate XL Instant XL (BXL02) FTS International Crosslinker Potassium hydroxide 1310-58-3 12.00 0.00485000
Sodium metaborate tetrahydrate 10555-76-7 25.00 0.01
Boric acid 10043-35-3 15.00 0.00606000
Additional Ingredients Not Listed on MSDS
HVG01 (TURQUOISE-1 BULK) FTS International Gelling Agent Distillates, petroleum, hydrotreated light 64742-47-8 55.00 0.06
Guar gum 9000-30-0 50.00 0.05
Ethoxylated propoxylated C12-14 alcohols 68439-51-0 2.00 0.00233000
Quartz 14808-60-7 2.00 0.00233000
LT Encapsulated AP Breaker (LTB01) FTS International Breaker Quartz 14808-60-7 25.00 0.02
Peroxydisulfuric acid, diammonium salt 7727-54-0 100.00 0.11
Proprietary Cured Acrylic Resin 25.00 0.02
Fresh Water Carrier/Base Fluid 83.55
MC B 8642 WS, NaturaLine MX 588-2 Multi-Chem Group Anti-Bacterial Agent, Scale Inhibitor Water 7732-18-5
Non-MSDS Components Not Provided by Supplier
Methanol 67-56-1
Northern White Sand FTS International Proppant - Natural Quartz 14808-60-7 100.00 13.99
APB01 (AMMONIUM PERSUFATE BREAKER),

B10 (HIGH PH BUFFER), BXL02 Borate XL, CI-150, FE 200, FRW-200, LTB-01

FTS International Breaker, Corrosion Inhibitor, Cross Linker, Friction Reducer, Iron Control Agent, pH Adjusting Agent Proprietary Corrosion Inhibitor Additive (CI-150)
Proprietary Iron Control Additive (FE-200L)
Proprietary Breaker (APB01) Additive
Water 7732-18-5
Proprietary Breaker Additive (LTB-1)
Proprietary Friction Reducer Additive

(FRW-200 and FRW-200W)

10.1 - 15 HCL FTS International Acid Water 7732-18-5 85.00 0.55
Hydrochloric acid 7647-01-0 15.00 0.09

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2012-11-14 H2O 15 11092 Bbl 699408 Frac Tech Services STAGE 4

40 SHOTS

2012-11-14 H2O 15 10579 Bbl 699730 Frac Tech Services STAGE 1

40 SHOTS

0 0 0
2012-11-14 H2O 15 10633 Bbl 699730 Frac Tech Services STAGE 2

40 SHOTS

2012-11-15 H2O 15 10334 Bbl 698408 Frac Tech Services STAGE 5

40 SHOTS

2012-11-15 H2O 15 10551 Bbl 703624 Frac Tech Services STAGE 7

40 SHOTS

2012-11-15 H2O 15 10474 Bbl 695442 Frac Tech Services STAGE 6

40 SHOTS

2012-11-14 H2O 15 10765 Bbl 696390 Frac Tech Services STAGE 3

40 SHOTS

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2013 CHESAPEAKE EXPLORATION LLC 0 0 2
2014 CHESAPEAKE EXPLORATION LLC 267714 1651 174
2015 CHESAPEAKE EXPLORATION LLC 252982 1054 363
2016 CHESAPEAKE EXPLORATION LLC 178293 483 366
2017 CHESAPEAKE EXPLORATION LLC 140773 368 365
2018 CHESAPEAKE EXPLORATION LLC 120412 314 365
2019 CHESAPEAKE EXPLORATION LLC 27683 88 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2013 CHESAPEAKE EXPLORATION LLC Brine 816 2
2014 CHESAPEAKE EXPLORATION LLC Brine 6027 174
2015 CHESAPEAKE EXPLORATION LLC Brine 4185 363
2016 CHESAPEAKE EXPLORATION LLC Brine 2516 366
2017 CHESAPEAKE EXPLORATION LLC Brine 1602 365
2018 CHESAPEAKE EXPLORATION LLC Brine 1241 365
2019 CHESAPEAKE EXPLORATION LLC Brine 467 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1193860219 2012-10-14 0:00 DD No Violations
-1929721836 2012-10-12 0:00 DD No Violations
-193270321 2016-10-24 0:00 PW No Violations 1.50
-33698122 2016-4-4 0:00:0 PW No Violations
-446483847 2016-3-2 0:00:0 PL No Violations
-805651358 2102-10-30 0:00 DD No Violations
-918304266 2013-9-13 0:00: DD No Violations
0033698122 2016-04-04 Production Wells No Violations I was on location for a status check. My inspection found the access road gate locked and the

access road is in good repair. An identification sign at the access road entrance, well, and tank battery. The pad is fenced and all man doors are locked. The #10H well is in production. The well is equipped with a christmas tree valve assembly. There is a steel dike around the tank battery. The equipment on the pad consists of the following: 2 - Storage tanks 400 bbl 1 - Vapor recovery unit (VRU) 1 - Gas processing unit (GPU) 1 - Sand separator 1 - Thermal electric generator 1 - Producing well Site fenced and man doors locked

0193270321 2016-10-24 Production Wells No Violations The purpose for my inspection was to conduct a status check on the Riffle 21-15-3 #10H (#2-1737-00-
0446483847 2016-03-02 Preliminary Restoration No Violations I was on location for a status check. My inspection found the access road gate locked and the access road is in good repair. An identification sign at the access road entrance, well, and tank battery. The pad is fenced and all man doors are locked. The #10H well is in production. The well is equipped with a plunger lift assembly. There is a steel dike around the tank battery.

The equipment on the pad consists of the following: 2 - Storage tanks 400 bbl 1 - Vapor recovery unit (VRU) 1 - Gas processing unit (GPU) 1 - Sand separator 1 - Thermal electric generator 1 - Producing well Site fenced and man doors locked

0729864468 2012-10-09 Drill / Deepen / Reopen No Violations I went to the site to check on the progress of completion of the surface casing installation. Nomac 310 had spudded the well on 10/07/2012, and TDd the surface hole at 591 KB on 10/07/2012. The rig had installed the 13.375 OD casing to the bottom of the hole and attempted to circulate. The casing pressured up, as it appeared to be packed off. The rig began to remove the casing, and got hung up. The casing parted and part of the casing string fell down hole. The rig had to fish it out. At the time of my site visit, there was still one joint of casing in the hole. Fishing would continue until the last joint was removed. A new string of surface casing would then be installed.
0763189225 2012-09-07 Drill / Deepen / Reopen No Violations
0805651358 2102-10-30 Drill / Deepen / Reopen No Violations

-Tex Pumping was the cementing contractor. The cement job was done in stages. Following a spacer designed to recover the oil-based mud used to drill the hole and condition the hole, a scavenger cement followed by a tail cement were pumped. The scavenger cement was mudscaled at 13.0 pounds per gallon (ppg). O-Tex pumped 229 bbls of scavenger cement at 13.0 ppg. O-Tex then pumped 393 bbls of tail cement at 15.3 ppg. The plug was dropped, and displaced with 283 bbls of water. When the displacement volume reached 195 bbls, circulation was lost. According to a representative of O-

0918304266 2013-09-13 Drill / Deepen / Reopen No Violations I went to the site to check the completion of the mousehole and the cellar. The mousehole was installed within the cellar, and both were well cemented. The site is ready for the arrival of the drilling rig.
1193860219 2012-10-14 Drill / Deepen / Reopen No Violations

-Tex Pumping was the cementing contractor. There was good fluid circulation throughout the cementing operation. The cement was mudscaled at 15.6 pounds per gallon (ppg), and O-Tex and pumped 106 bbls of cement slurry at 15.6 ppg. Cement returns to the surface were observed. An estimated 8 bbls of cement returned to the surface. The plug was displaced with 96 bbls of water. The plug bumped the float collar at 11:23am. Pressure held. The float held when the pressure was released, and 0.5 bbls of water bled back.

1367953544 2012-09-05 Drill / Deepen / Reopen No Violations I was at the site to check the progress on the conductor drilling operation. United Drilling was on location and in the process of drilling the conductor hole. The cellar was installed.
1368100671 2012-10-10 Drill / Deepen / Reopen No Violations

-Tex Pumping was the cementing contractor. There was good fluid circulation throughout the cementing operation. The cement was mudscaled at 15.8 lbs per gallon (ppg), and then adjusted to 15.6 ppg. O-Tex pumped 117.5 bbls of cement slurry at 15.6 ppg. Cement returns to surface were observed. An estimated 23 bbls of cement returned to surface. The plug was displaced with 85 bbls of water. The plug bumped the float collar at 4:37pm. O-Tex pressured up on the casing, and the pressure held. When the pressure was released, approximately 0.5 bbl of water flowed back, and the float held.

1409837557 2014-06-17 Preliminary Restoration No Violations I stopped by the site to check on the status of well completion and restoration. The well has been hydraulically fractured. There is two 400 barrel tanks and one GPU production unit. The well is equipped with a Christmas tree. Values are locked out. Tanks or the wellhead do note have ID signs posted. I walked the entire site, and found the location to be in good condition. All erosion and sedimentation controls, and drainage controls appear to be functioning. Ground cover is well established along the access road and around the drilling pad. No areas of erosion are present. Preliminary restoration approval will not be finalized until well is in production and ID sigs are posted.
1563976565 2019-7-23 0:00: PW No Violations 2.00
1929721836 2012-10-12 Drill / Deepen / Reopen No Violations I stopped at the site to check on the drilling progress for the intermediate casing. I met with drilling consultant, Joe Bailey. Drilling hadnt resumed due to mechanical issues.
2011006015 2012-10-05 Drill / Deepen / Reopen No Violations I went to the site to have a pre-spud meeting with drilling consultant Mike Kirkpatrick of Chesapeake. Nomac 310 was onsite, and rigging up. I reviewed the new well construction regulations with Mr. Kirkpatrick, and provided him with a copy. Drilling superintendent John Snook requested a copy as well. The rig anticipated spudding on Saturday 10/06/2012.
729864468 2012-10-9 0:00: DD No Violations
763189225 2012-9-7 0:00:0 DD No Violations

For data sources see[10]