If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-147-61168 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.16,"lon":-83.2,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Seneca | |
Municipality: Hopewell Township | |
Operator Name: EWALD HERBERT O FAMILY FARM LL | |
Well Pad ID: | |
Farm/Lease Name: DYSARD | |
License Status: Final Restoration | |
License Date: 2011-06-10 | |
Spud Date: | |
Spud Drilling Contractor: | |
Final Drill Date: | |
Well Total Depth: | |
Configuration: Vertical | |
Latitude: 41.160000 | |
Longitude: -83.200000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2011-06-10 | Proposed Formations:TRENTON, Issued Date:6/10/2011, Expired Date:6/9/2013 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2011-07-21 | INSPECTED BY TOM BENKO ON 2/2/05. 10 & 8 INCH CASING, TUBING AND RODS. PUMP JACK AND PRODUCTION LINE. WELL SHUT-IN AND POLISH RODS ARE RUSTED IN. LANDOWNER INDICATED THAT THE WELL WAS DRILLED IN THE 1930'S. |
Construction Permit Expires | 2013-06-09 | INSPECTED BY TOM BENKO ON 2/2/05. 10 & 8 INCH CASING, TUBING AND RODS. PUMP JACK AND PRODUCTION LINE. WELL SHUT-IN AND POLISH RODS ARE RUSTED IN. LANDOWNER INDICATED THAT THE WELL WAS DRILLED IN THE 1930'S. |
Record Last Modified | 2015-09-24 | INSPECTED BY TOM BENKO ON 2/2/05. 10 & 8 INCH CASING, TUBING AND RODS. PUMP JACK AND PRODUCTION LINE. WELL SHUT-IN AND POLISH RODS ARE RUSTED IN. LANDOWNER INDICATED THAT THE WELL WAS DRILLED IN THE 1930'S. |
For data sources see[2]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1450365232 | 2011-7-20 0:00: | PB | No Violations | |
-1949158763 | 2005-2-2 0:00:0 | PW | No Violations | |
-808737534 | 2001-6-15 0:00: | PW | No Violations | |
-808737534167090 | 2001-6-15 0:00: | PW | No Violations | |
-904687880 | 2011-8-2 0:00:0 | FR | No Violations | |
0808737534 | 2001-06-15 | Production Wells | Violations Noted | FOLLOW UP TO NOV # 1210i18 Well inspection result of complaint (Linda Taylor). ID posted but faded. Gas leak at fitting on separator 1/4 inch line from separator to murphy switch. Small leak of raw gas. ( H2S). Wellhead leaking from casing head strong l |
0904687880 | 2011-08-02 | Final Restoration | No Violations | Inspect well location. Well plugged. Restoration complete. Site ok. |
1296588723 | 2011-01-04 | Production Wells | No Violations | Inspect well with Craig Frantz. Well may be plugged with land conservation funding. 10 inch orange peal, 6 inch casing, well head, 2 inch tubing, rods, pump jack w/ electric motor. Overgrown with weeds. |
1311187563 | 2011-07-13 | Plug / Plug Back | No Violations | On site for bottom plug of well. Well was drilled out to 1200 and 2 3/8 upset pipe set at 1150. 90 sacks Class A cement weighing 15 lb/gal at 6 gal/sack. Circulation throughout job. Tubing pulled out and will tag cement and fill remainder at a later date. |
1450365232 | 2011-07-20 | Plug / Plug Back | No Violations | On site for upper plug of well. Tagged bottom plug from 7/13/2011 at 870 and set pipe to 864. Ran 100 sacks class A weighing 14.7 as measured by inspector w/ good circulation then pulled 18 joints (576) leaving 9 joints (288) in hole. Next cement truck came w/ 65 sacks class A weighing 15.1 as measured by inspector. Cement circulated to surface in roughly 45 sacks. Tubing pulled and cement dropped back. Will tag and top off at later date. |
1489953801 | 2011-08-16 | Final Restoration | No Violations | Well Plugged in July, 2011. Site graded back suitable for farming next spring. Final Restoration Passed. |
1949158763 | 2005-02-02 | Production Wells | No Violations | Inspect Well. Well does not correlate with existing permit number. Add well to system. Ten inch casing, eight inch casing, tubing and rods, Pump jack and production line. Well shut in and Polish rod is rusted in. Landowner indicated the well was drilled in the 1930s. |
8087375341 | 2001-06-15 | Production Wells | No Violations | FOLLOW UP TO NOV # 1210i18 Well inspection result of complaint (Linda Taylor). ID posted but faded. Gas leak at fitting on separator 1/4 inch line from separator to murphy switch. Small leak of raw gas. ( H2S). Wellhead leaking from casing head strong leak of H2S gas. Gas meter at |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0808737534 | US-OH-129202 | 2001-06-15 | Failure to legibly identify well | |
0808737534 | US-OH-129203 | 2001-06-15 | Unlawful venting or flaring of gas | |
0808737534 | US-OH-129204 | 2002-04-03 | Disposal of muds or cuttings in violation of a rule |
For data sources see[3]