34-085-21161

Well Details

Well ID: 34-085-21161
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: ROCKEFELLER OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: NEWELL CREEK
License Status: Producing
License Date: 2005-07-15
Spud Date: 2006-02-04
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2006-02-11
Well Total Depth: 3366.00 ft
Configuration: Vertical
Latitude: 41.640000
Longitude: -81.340000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-07-15 Proposed Formations:CLINTON, Issued Date:7/15/2005, Expired Date:7/15/2006 6:00:00 AM, Drilling unit acres:20.57, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2006-02-04 RBDMS Rec
Completed 2006-02-11 RBDMS Rec
Reached Total Depth 2006-02-11 RBDMS Rec
Completion Report Received 2006-05-08 RBDMS Rec
Construction Permit Expires 2006-07-15 RBDMS Rec
Change of Owner 2016-12-05 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-07-28 3192 3210 15
3192 3210 15
3192 3210 15

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 549 Bbl 120000 699M SCF NITROGEN ASSIST

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 GREAT PLAINS EXPLORATION LLC 10342.00 78.00 241
2007 GREAT PLAINS EXPLORATION LLC 9766.00 339.00 365
2008 GREAT PLAINS EXPLORATION LLC 4060.00 235.00 365
2009 GREAT PLAINS EXPLORATION LLC 3888.00 73.00 365
2010 GREAT PLAINS EXPLORATION LLC 3823.00 35.00 365
2011 GREAT PLAINS EXPLORATION LLC 2783.00 60.00 365
2012 GREAT PLAINS EXPLORATION LLC 1895.00 66.00 366
2013 GREAT PLAINS EXPLORATION LLC 1319.00 54.00 365
2014 GREAT PLAINS EXPLORATION LLC 1027.00 34.00 365
2015 GREAT PLAINS EXPLORATION LLC 1121.00 0.00 365
2016 ROCKEFELLER OIL COMPANY LLC 393.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 GREAT PLAINS EXPLORATION LLC Brine 0 241
2007 GREAT PLAINS EXPLORATION LLC Brine 920 365
2008 GREAT PLAINS EXPLORATION LLC Brine 830 365
2009 GREAT PLAINS EXPLORATION LLC Brine 480 365
2010 GREAT PLAINS EXPLORATION LLC Brine 320 365
2011 GREAT PLAINS EXPLORATION LLC Brine 560 365
2012 GREAT PLAINS EXPLORATION LLC Brine 240 366
2013 GREAT PLAINS EXPLORATION LLC Brine 280 365
2014 GREAT PLAINS EXPLORATION LLC Brine 235 365
2015 GREAT PLAINS EXPLORATION LLC Brine 316 365
2016 GREAT PLAINS EXPLORATION LLC Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1089193535 2019-3-28 0:00: UP No Violations
-192239438 2006-2-6 0:00:0 DD No Violations
-2004620303 2019-11-4 0:00: UP No Violations
-299814119 2009-8-3 0:00:0 PL No Violations
-677504774 2018-6-14 0:00: UP No Violations 1.00
-940272134 2017-4-14 0:00: UP No Violations 0.50
-990543749 2010-4-23 0:00: PW No Violations
0192239438 2006-02-06 Drill / Deepen / Reopen No Violations drilling 640

no Violation

0299814119 2009-08-03 Preliminary Restoration No Violations
0677504774 2018-06-14 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked. At the time of this inspection, I observed the following: there were no locks at the load-line valves. The unit identification reamained unchanged and required updating to reflect the new ownership. A portion of the wellhead enclosure had fallen over. The well was not in active production and there was not an active chart record. I have contacted the company on several occasions since the issuance of the compliance notice. The company has reported that problems with personnel and/or lack of funds, have prevented them from being in compliance.
0940272134 2017-04-14 UrbanProduction Wells No Violations I inspected this producing well as a follow-up to a previously-issued Compliance Notice. At the time of the previous inspection, I had noted that the load-line valves and enclosure gates were not secure with locks as required. At the time of this inspection, I observed the following: the access road to the well and battery, which is comprised of a gravel-paved road that enters from Norton Parkway and travels 300 feet to the well and battery, was in fair condition with some pot-holing but was passable. The separate enclosure gates were unlocked. The wellhead enclosure was partially broken down. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure and free from leakage. I walked the areas surrounding both the well and the battery and found no signs problems or impact to the surrounding in-situ features. I did observe the following maintenance and safety deficiencies; the load line valves remain unsecured with locks, the ID signage had not been updated to reflect the recent change in ownership. In addition, I observed that the tanks were lacking the required process safety equipment (spark arrestor, low-pressure relief valve, carbon filter). I attempted to contact both company representatives John Magnussen and Richard Osborne and, as of the filing of this report, no representative of the company has responded.
0990543749 2010-04-23 Production Wells No Violations No violations were found at the time of inspection.
1089193535 2019-03-28 UrbanProduction Wells Violations Noted I was on location conducting a compliance notice follow-up inspection for compliance notice # 1509520352, regarding the installation of locks on the load lines and tank valves. At the time of this inspection, the load line and tank valves have not been equipped with locks. The well was not in production and the gate valve on the tubing and the 2 inch flow line were closed. The well was surrounded by a board on board enclosure with a locked door. The mechanical separator had open valves but no chart was present. The board on board enclosure surrounding the separator was missing sections and the door was not equipped with a lock. The tank battery consisted of one 210 BBL tank and one 100 BBL tank. The required urban safety equipment (low-pressure relief valve, spark arrestor, carbon filter), has not been installed on the production tanks and needs installed. The tank valves still needed locks installed. Board on board fencing surrounded the tanks, but a tree has fallen onto the enclosure. Some damage has occurred to the enclosure that needs repaired. The door on the enclosure was locked. Identification on the tank battery enclosure has not been updated to reflect current owner information. Lease access was stable. I contacted Rockefeller Oil Co. and spoke with Jenny Corrao, regarding the locks for tank valves needing installed and installing the urban safety equipment on the production tanks. I also addressed the enclosure repair needed at the tank and separator location along with a lock needing installed on the separator enclosure door, and updated identification.
1235806187 2006-07-17 Preliminary Restoration No Violations site no violation.
1250860761 2019-5-16 0:00: UP No Violations
1456334416 2006-07-17 Preliminary Restoration No Violations
1509520352 2016-02-18 UrbanProduction Wells Violations Noted I inspected this producing well as part of routine inspection activity. At the time of my inspection, I observed the following elements: a wellhead with mechanical plunger lift and tank battery consisting of one 210-barrel steel, storage tank, one 100-barrel steel brine storage tank, with mechanical separator. The battery and wellhead were in in separate board-on-board enclosures. Fittings and connections are free from leakage. The dedicated access road is in good condition. The enclosure gates were not locked and secure. The load-line valves were not locked and must be secured with locks. The owner must remedy the following by 04/01/2016: secure the load-line valves and enclosure gates with locks. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
1556722462 2019-5-1 0:00:0 UP No Violations
1585244816 2020-3-26 0:00: UP No Violations
1726149846 2017-09-01 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: the load-lines and well enclosure were no secured with locks and the system was missing spark arrestor, low-pressure relief valve, and carbon filter. In addition, the identifying signage had remained unchanged since the previous change of ownership and had not been updated to reflect new ownership. At the time of this inspection, the aforementioned deficiencies had not been remedied. The owner has made repeated pledges to address the issues, but with no demonstrable progress.
1824815001 2014-07-29 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well was completed in 02/11/2006. The unit is producing and production reports are current. Elements of the well consist of a production wellhead with standard valve assembly and mechanical plunger-lift system and aboveground storage tank (AST) battery. The wellhead and battery are accessed via a dedicated gravel access road which travels south from Norton Parkway, to an isolated, mostly undeveloped area. The surrounding areas beyond are comprised of a newer offcie park development. The aboveground storage tank (AST) battery is located 50 feet to the northeast in a separate board-on-board enclosure. The battery is comprised of a total of 1 steel 100-barrel production tank and 1 100-barrel brine tank, and horizontal separator in a 3rd, separate, locked enclosure. Spacing from well to battery, and spacing of elements within the battery meet regulations. The load-outs are bull-plugged. The secondary containment at the battery is present but very low and not adequate to contain a release. I did not observe any signs or evidence of leakage, spills, or problems. There is ID signage at the battery which is legible and in good condition. The area surrounding the wellhead slopes to the south towards a small pond which is 200 feet west-southwest of the unit. I did not observe any signs of drainage or erosional deficits associated with the unit. I notified Great Plains about the containment dike deficiency.
1981445496 2017-12-12 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: The load-lines were no locked and secure. At the time of this inspection, I observed the following: the noted deficiencies remained. In addition, the unit ID signage had not been updated to reflect the change in ownership that had occurred in 2016. I had previously contacted the company about the deficiencies and they had reported various issues regarding lack of personnel and funds preventing them from being in compliance.
2051152751 2019-11-19 0:00 UP No Violations
686070202 2020-6-2 0:00:0 UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1089193535 US-OH-102067 2019-04-04 9-05E1 ID (a-i)
1089193535 US-OH-102068 2019-04-04 9-05E2 FENCING (a-d)
1089193535 US-OH-102069 2019-04-04 9-05E4 TANKS (a-i)
1509520352 US-OH-114274 2016-04-27 LOCKS

For data sources see[9]