Well ID: 34-085-21230 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.59,"lon":-81.34,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: INDUSTRY STANDARD SUPPLIES INC | |
Well Pad ID: | |
Farm/Lease Name: KIRTLAND FELLOWSHIP CHURCH | |
License Status: Producing | |
License Date: 2007-04-11 | |
Spud Date: 2007-05-05 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2007-05-11 | |
Well Total Depth: 3744.00 ft | |
Configuration: Vertical | |
Latitude: 41.590000 | |
Longitude: -81.340000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2007-04-11 | Proposed Formations:CLINTON, Issued Date:4/11/2007, Expired Date:4/10/2008 6:00:00 AM, Drilling unit acres:34, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2007-05-11 | |
Completion Report Received | 2008-02-28 | |
Construction Permit Expires | 2008-04-10 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-05-30 | 3529 | 3545 | 16 |
3529 | 3545 | 16 | |
3529 | 3545 | 16 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 52500 Gal | 30000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | INDUSTRY STANDARD SUPPLIES INC | 18455.00 | 299.00 | 365 |
2009 | INDUSTRY STANDARD SUPPLIES INC | 8966.00 | 55.00 | 365 |
2010 | INDUSTRY STANDARD SUPPLIES INC | 7820.00 | 66.00 | 365 |
2011 | INDUSTRY STANDARD SUPPLIES INC | 7167.00 | 74.00 | 365 |
2012 | INDUSTRY STANDARD SUPPLIES INC | 6304.00 | 57.00 | 366 |
2013 | INDUSTRY STANDARD SUPPLIES INC | 5175.00 | 0.00 | 365 |
2014 | INDUSTRY STANDARD SUPPLIES INC | 4565.00 | 31.00 | 365 |
2015 | INDUSTRY STANDARD SUPPLIES INC | 4026.00 | 0.00 | 365 |
2016 | INDUSTRY STANDARD SUPPLIES INC | 3210.00 | 0.00 | 365 |
2017 | INDUSTRY STANDARD SUPPLIES INC | 3859.00 | 54.00 | 365 |
2018 | INDUSTRY STANDARD SUPPLIES INC | 3493.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | INDUSTRY STANDARD SUPPLIES INC | Brine | 0 | 365 |
2009 | INDUSTRY STANDARD SUPPLIES INC | Brine | 0 | 365 |
2010 | INDUSTRY STANDARD SUPPLIES INC | Brine | 0 | 365 |
2011 | INDUSTRY STANDARD SUPPLIES INC | Brine | 0 | 365 |
2012 | INDUSTRY STANDARD SUPPLIES INC | Brine | 0 | 366 |
2013 | INDUSTRY STANDARD SUPPLIES INC | Brine | 152 | 365 |
2014 | INDUSTRY STANDARD SUPPLIES INC | Brine | 75 | 365 |
2015 | INDUSTRY STANDARD SUPPLIES INC | Brine | 247 | 365 |
2016 | INDUSTRY STANDARD SUPPLIES INC | Brine | 248 | 365 |
2017 | INDUSTRY STANDARD SUPPLIES INC | Brine | 154 | 365 |
2018 | INDUSTRY STANDARD SUPPLIES INC | Brine | 169 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1083995400 | 2008-5-20 0:00: | DD | No Violations | |
-1608555594 | 2019-1-7 0:00:0 | UP | No Violations | |
-1663688636 | 2007-6-4 0:00:0 | DD | No Violations | |
-1836951035 | 2012-3-30 0:00: | UP | No Violations | |
-1888225489 | 2010-10-26 0:00 | PW | No Violations | |
-208827469 | 2007-8-15 0:00: | PW | No Violations | |
-251123092 | 2007-5-8 0:00:0 | DD | No Violations | |
-274460368 | 2007-6-1 0:00:0 | DD | No Violations | |
-400906276 | 2017-9-13 0:00: | UP | No Violations | 0.50 |
-438874232 | 2010-12-10 0:00 | PW | No Violations | |
-481811087 | 2007-6-4 0:00:0 | DD | No Violations | |
-483125713 | 2007-6-1 0:00:0 | DD | No Violations | |
-804724432 | 2008-7-1 0:00:0 | PW | No Violations | |
-873199388 | 2010-12-13 0:00 | PW | No Violations | |
-971332273 | 2010-12-11 0:00 | PW | No Violations | |
0115910060 | 2011-02-18 | Production Wells | No Violations | Recent clean-up work was done. There was new sorbent boom deployed at three points along stream. |
0208827469 | 2007-08-15 | Production Wells | No Violations | fence up area strawed wait till spring for grass |
0251123092 | 2007-05-08 | Drill / Deepen / Reopen | No Violations | checking site for pit closer |
0274460368 | 2007-06-01 | Drill / Deepen / Reopen | Violations Noted | Blow pit closed advised company that the pit will have to be dug up and solidified and put in a relined pit. Company Mike abernathy said the material will be due on Monday. |
0400906276 | 2017-09-13 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger-lift system and associated tank battery in separate enclosures, both located on a parcel occupied by a church. The enclosure gates were locked and secure. The load-line valves were secure. Tank lids were closed and secure. The secondary containment was intact and dry. I walked the areas surrounding the well and battery and found no signs of impacts or problems. |
0438874232 | 2010-12-10 | Production Wells | Violations Noted | FOLLOW UP TO NOV # 1292413254 On December 10, the well owner discovered that a malfunction had caused the well to run continuously and overflow a 100 barrel tank. Furthermore, approximately 10 barrels of oil was found to have escaped the tank battery dike and traveled down the embank |
0481811087 | 2007-06-04 | Drill / Deepen / Reopen | No Violations | on site blow pit dug up put in relined pit and solidified. Closed |
0483125713 | 2007-06-01 | Drill / Deepen / Reopen | No Violations | pit problem need to dig up air pit and reline pit |
0707224876 | 2008-07-01 | Production Wells | No Violations | FOLLOW UP TO NOV # -804724432 called company advised to get ID sign up at tank battery |
0804724432 | 2008-07-01 | Production Wells | Violations Noted | called company advised to get ID sign up at tank battery |
0873199388 | 2010-12-13 | Production Wells | No Violations | The initial clean-up was completed. Boom was in place.
Remedial clean-up will need to continue. |
0903497580 | 2012-03-30 | UrbanProduction Wells | Violations Noted | FOLLOW UP TO NOV # -1836951035 My inspection of this well site found that the equipment spacing at the tank battery is not correct. The separator is approximately 3 from the production tank. The rules state a minimum of 10 should be maintained between these two pieces of equipment and the well owner was instructed to switch the brine tank and the production tank to meet spacing requirements. The soil of the tank battery floor is stained with crude oil, which must be removed and disposed of properly. There is a seep in the north west corner of the tank battery, where the sales line comes out of it. There is approximately one quart of free oil below the seep. There is water accumulating at the seep that has bacterial iron in it, causing red discoloring. I tested this water for chlorides and they were below drinking water standards. Oil soaked debris remains below the tank battery from a previous release from the tank battery. The well owner was instructed to clean up this debris and dispose of it properly. The valve at the south end of the load line has separated but the load line does have a second valve at the tank. The well owner has a thread protector screwed onto the south end of the load line but has been instructed to replace the valve. This valve needs to be located inside of the dike. The well owner was notified, by phone, during inspection of the needed clean up and repairs. |
0971332273 | 2010-12-11 | Production Wells | No Violations | The clean up was progressing. Two siphon dams were constructed and additional sorbent boom was deployed. Two vacuum trucks and a water truck were in use to recover the oil. |
0998582587 | 2010-12-10 | Production Wells | Violations Noted | FOLLOW UP TO NOV # 1345224672 FOLLOW UP TO NOV # 1292413254 On December 10, the well owner discovered that a malfunction had caused the well to run continuously and overflow a 100 barrel tank. Furthermore, approximately 10 barrels of oil was found to have escaped the tank battery dike and traveled down the embank |
1083995400 | 2008-05-20 | Drill / Deepen / Reopen | No Violations | addviced company that lease road ditch needs work and needs more restoration work |
1090978805 | 2008-07-01 | Production Wells | No Violations | FOLLOW UP TO NOV # -804724432 called company advised to get ID sign up at tank battery |
115910060 | 2011-2-18 0:00: | PW | No Violations | |
1292413254 | 2010-12-10 | Production Wells | Violations Noted | On December 10, the well owner discovered that a malfunction had caused the well to run continuously and overflow a 100 barrel tank. Furthermore, approximately 10 barrels of oil was found to have escaped the tank battery dike and traveled down the embank |
1345224672 | 2010-12-10 | Production Wells | No Violations | FOLLOW UP TO NOV # 1292413254 On December 10, the well owner discovered that a malfunction had caused the well to run continuously and overflow a 100 barrel tank. Furthermore, approximately 10 barrels of oil was found to have escaped the tank battery dike and traveled down the embank |
1352299148 | 2012-11-06 | UrbanProduction Wells | Violations Noted | I inspected this unit as a follow-up to the inspection and subsequent issuance of a Compliance Notice issued on 03/30/2012. At that time, the owner was advised to make repairs to address non-compliance with the following items: The mechanical separator is 24 inches from the existing production tank. The rules mandate a separation distance of 10 feet. The tank battery dike is failing at the northwest corner where a seep is actively draining. There are several trash-bags filled with soil, located outside the tank battery fence that are now decaying and split open. The load-line valves located outside the dike and are not secured. These conditions which were extant on 03/30/2012 have not been addressed as of 11/06/2012. In addition, I noted that the ID sign for the unit is not readable. On 11/07/2012, I contacted the owners representative Tim Levengood of Industry Standard Supplies. He indicated that they were not aware that this issue had been established as a Compliance Notice, and had reportedly attempted to contact someone within the ODNR Oil and Gas Division to get clarification. We agreed to meet at the site on 11/14/2012 to review the compliance issues. |
1352909881 | 2012-11-14 | Preliminary Restoration | No Violations | Site meeting with Tim Levengood of Industry Standard Supplies regarding the need to address the items outlined in the current Compliance Notice. Tim agreed to address the following items: move the mechanical separator to the east side of the interior of the tank battery to comply with the spacing requirements of 1501:9-9-05(A)(5), repair and reinforce the secondary containment dike in the northwest corner, move the load-out valves to the interior of the battery, remove residual refuse in trash bags, fix the Unit ID, regrade the area on the north side of the dike where runoff is washing out the berm. He indicated that the repairs would be made within the next two weeks. I asked him to contact me when the issues had been adressed. |
1371731696 | 2013-06-19 | Production Wells | No Violations | The ID at the wellhead is still missing-so I called Tim Levengood and he indicated that it would be taken care of. |
1428440000 | 2009-10-22 | Preliminary Restoration | No Violations | Preliminary restoration was completed. |
1446856314 | 2007-05-09 | Drill / Deepen / Reopen | No Violations | drilling 3000 |
1608555594 | 2019-01-07 | UrbanProduction Wells | No Violations | I conducted an inspection on this well. The well was equipped with a plunger lift assembly and in production, at the time of this inspection. The well was fenced and locked with legible identification. The tank battery was comprised of one 100 BBL tank, one 50 BBL tank and a mechanical separator. Valves on the separator were open. The diked tank battery was fenced with a locked door and legible identification. Lease access to the well and tank battery were stable. |
1663688636 | 2007-06-04 | Drill / Deepen / Reopen | No Violations | on site to reline and solidified the air pit |
1774379580 | 2013-10-09 | UrbanProduction Wells | No Violations | The producing unit consists of a wellhead and aboveground storage tank (AST) battery in separate board-on-board enclosures. The wellhead is a plunger lift unit and is producing. The battery is comprised of 1 140-barrel and 1 50-barrel steel tank and separator. Secondary containment, spacing, and signage is good. Process safety equipment (spark arrestor, carbon filter, and low-pressure relief valve) are present. Gates are locked. ID placard has been replaced. No problems noted. Impact relating to the release that occurred on 12/10/2010 has been effectively remedied. |
1836951035 | 2012-03-30 | UrbanProduction Wells | Violations Noted | My inspection of this well site found that the equipment spacing at the tank battery is not correct. The separator is approximately 3 from the production tank. The rules state a minimum of 10 should be maintained between these two pieces of equipment and the well owner was instructed to switch the brine tank and the production tank to meet spacing requirements. The soil of the tank battery floor is stained with crude oil, which must be removed and disposed of properly. There is a seep in the north west corner of the tank battery, where the sales line comes out of it. There is approximately one quart of free oil below the seep. There is water accumulating at the seep that has bacterial iron in it, causing red discoloring. I tested this water for chlorides and they were below drinking water standards. Oil soaked debris remains below the tank battery from a previous release from the tank battery. The well owner was instructed to clean up this debris and dispose of it properly. The valve at the south end of the load line has separated but the load line does have a second valve at the tank. The well owner has a thread protector screwed onto the south end of the load line but has been instructed to replace the valve. This valve needs to be located inside of the dike. The well owner was notified, by phone, during inspection of the needed clean up and repairs. |
1888225489 | 2010-10-26 | Production Wells | No Violations | ID was posted at the tank battery. NOV resolved. |
707224876 | 2008-7-1 0:00:0 | PW | No Violations | |
903497580 | 2012-3-30 0:00: | UP | No Violations | |
998582587 | 2010-12-10 0:00 | PW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0274460368 | US-OH-122837 | 2007-06-12 | Failure to comply with permit conditions | |
0438874232 | US-OH-124725 | 2013-10-09 | Well operation causing pollution and contamination | |
0804724432 | US-OH-129137 | 2008-08-14 | Failure to legibly identify well | |
0903497580 | US-OH-130315 | 2015-03-27 | Well operation causing pollution and contamination | |
0998582587 | US-OH-131466 | 2013-10-09 | Well operation causing pollution and contamination | |
1292413254 | US-OH-108249 | 2010-12-15 | Well operation causing pollution and contamination | |
1352299148 | US-OH-110193 | 2015-02-05 | Well operation causing pollution and contamination | |
1836951035 | US-OH-118346 | 2012-04-02 | Failure to meet mechanical seperator spacing requirements from oil tanks |
For data sources see[9]