34-085-21230

Well Details

Well ID: 34-085-21230
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: INDUSTRY STANDARD SUPPLIES INC
Well Pad ID:
Farm/Lease Name: KIRTLAND FELLOWSHIP CHURCH
License Status: Producing
License Date: 2007-04-11
Spud Date: 2007-05-05
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2007-05-11
Well Total Depth: 3744.00 ft
Configuration: Vertical
Latitude: 41.590000
Longitude: -81.340000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-04-11 Proposed Formations:CLINTON, Issued Date:4/11/2007, Expired Date:4/10/2008 6:00:00 AM, Drilling unit acres:34, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2007-05-11
Completion Report Received 2008-02-28
Construction Permit Expires 2008-04-10
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-05-30 3529 3545 16
3529 3545 16
3529 3545 16

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 52500 Gal 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 INDUSTRY STANDARD SUPPLIES INC 18455.00 299.00 365
2009 INDUSTRY STANDARD SUPPLIES INC 8966.00 55.00 365
2010 INDUSTRY STANDARD SUPPLIES INC 7820.00 66.00 365
2011 INDUSTRY STANDARD SUPPLIES INC 7167.00 74.00 365
2012 INDUSTRY STANDARD SUPPLIES INC 6304.00 57.00 366
2013 INDUSTRY STANDARD SUPPLIES INC 5175.00 0.00 365
2014 INDUSTRY STANDARD SUPPLIES INC 4565.00 31.00 365
2015 INDUSTRY STANDARD SUPPLIES INC 4026.00 0.00 365
2016 INDUSTRY STANDARD SUPPLIES INC 3210.00 0.00 365
2017 INDUSTRY STANDARD SUPPLIES INC 3859.00 54.00 365
2018 INDUSTRY STANDARD SUPPLIES INC 3493.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2009 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2010 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2011 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2012 INDUSTRY STANDARD SUPPLIES INC Brine 0 366
2013 INDUSTRY STANDARD SUPPLIES INC Brine 152 365
2014 INDUSTRY STANDARD SUPPLIES INC Brine 75 365
2015 INDUSTRY STANDARD SUPPLIES INC Brine 247 365
2016 INDUSTRY STANDARD SUPPLIES INC Brine 248 365
2017 INDUSTRY STANDARD SUPPLIES INC Brine 154 365
2018 INDUSTRY STANDARD SUPPLIES INC Brine 169 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1083995400 2008-5-20 0:00: DD No Violations
-1608555594 2019-1-7 0:00:0 UP No Violations
-1663688636 2007-6-4 0:00:0 DD No Violations
-1836951035 2012-3-30 0:00: UP No Violations
-1888225489 2010-10-26 0:00 PW No Violations
-208827469 2007-8-15 0:00: PW No Violations
-251123092 2007-5-8 0:00:0 DD No Violations
-274460368 2007-6-1 0:00:0 DD No Violations
-400906276 2017-9-13 0:00: UP No Violations 0.50
-438874232 2010-12-10 0:00 PW No Violations
-481811087 2007-6-4 0:00:0 DD No Violations
-483125713 2007-6-1 0:00:0 DD No Violations
-804724432 2008-7-1 0:00:0 PW No Violations
-873199388 2010-12-13 0:00 PW No Violations
-971332273 2010-12-11 0:00 PW No Violations
0115910060 2011-02-18 Production Wells No Violations Recent clean-up work was done. There was new sorbent boom deployed at three points along stream.
0208827469 2007-08-15 Production Wells No Violations fence up area strawed wait till spring for grass
0251123092 2007-05-08 Drill / Deepen / Reopen No Violations checking site for pit closer
0274460368 2007-06-01 Drill / Deepen / Reopen Violations Noted Blow pit closed advised company that the pit will have to be dug up and solidified and put in a relined pit. Company Mike abernathy said the material will be due on Monday.
0400906276 2017-09-13 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger-lift system and associated tank battery in separate enclosures, both located on a parcel occupied by a church. The enclosure gates were locked and secure. The load-line valves were secure. Tank lids were closed and secure. The secondary containment was intact and dry. I walked the areas surrounding the well and battery and found no signs of impacts or problems.
0438874232 2010-12-10 Production Wells Violations Noted FOLLOW UP TO NOV # 1292413254 On December 10, the well owner discovered that a malfunction had caused the well to run continuously and overflow a 100 barrel tank. Furthermore, approximately 10 barrels of oil was found to have escaped the tank battery dike and traveled down the embank
0481811087 2007-06-04 Drill / Deepen / Reopen No Violations on site blow pit dug up put in relined pit and solidified. Closed
0483125713 2007-06-01 Drill / Deepen / Reopen No Violations pit problem need to dig up air pit and reline pit
0707224876 2008-07-01 Production Wells No Violations FOLLOW UP TO NOV # -804724432 called company advised to get ID sign up at tank battery
0804724432 2008-07-01 Production Wells Violations Noted called company advised to get ID sign up at tank battery
0873199388 2010-12-13 Production Wells No Violations The initial clean-up was completed. Boom was in place.

Remedial clean-up will need to continue.

0903497580 2012-03-30 UrbanProduction Wells Violations Noted FOLLOW UP TO NOV # -1836951035 My inspection of this well site found that the equipment spacing at the tank battery is not correct. The separator is approximately 3 from the production tank. The rules state a minimum of 10 should be maintained between these two pieces of equipment and the well owner was instructed to switch the brine tank and the production tank to meet spacing requirements. The soil of the tank battery floor is stained with crude oil, which must be removed and disposed of properly. There is a seep in the north west corner of the tank battery, where the sales line comes out of it. There is approximately one quart of free oil below the seep. There is water accumulating at the seep that has bacterial iron in it, causing red discoloring. I tested this water for chlorides and they were below drinking water standards. Oil soaked debris remains below the tank battery from a previous release from the tank battery. The well owner was instructed to clean up this debris and dispose of it properly. The valve at the south end of the load line has separated but the load line does have a second valve at the tank. The well owner has a thread protector screwed onto the south end of the load line but has been instructed to replace the valve. This valve needs to be located inside of the dike. The well owner was notified, by phone, during inspection of the needed clean up and repairs.
0971332273 2010-12-11 Production Wells No Violations The clean up was progressing. Two siphon dams were constructed and additional sorbent boom was deployed. Two vacuum trucks and a water truck were in use to recover the oil.
0998582587 2010-12-10 Production Wells Violations Noted FOLLOW UP TO NOV # 1345224672 FOLLOW UP TO NOV # 1292413254 On December 10, the well owner discovered that a malfunction had caused the well to run continuously and overflow a 100 barrel tank. Furthermore, approximately 10 barrels of oil was found to have escaped the tank battery dike and traveled down the embank
1083995400 2008-05-20 Drill / Deepen / Reopen No Violations addviced company that lease road ditch needs work and needs more restoration work
1090978805 2008-07-01 Production Wells No Violations FOLLOW UP TO NOV # -804724432 called company advised to get ID sign up at tank battery
115910060 2011-2-18 0:00: PW No Violations
1292413254 2010-12-10 Production Wells Violations Noted On December 10, the well owner discovered that a malfunction had caused the well to run continuously and overflow a 100 barrel tank. Furthermore, approximately 10 barrels of oil was found to have escaped the tank battery dike and traveled down the embank
1345224672 2010-12-10 Production Wells No Violations FOLLOW UP TO NOV # 1292413254 On December 10, the well owner discovered that a malfunction had caused the well to run continuously and overflow a 100 barrel tank. Furthermore, approximately 10 barrels of oil was found to have escaped the tank battery dike and traveled down the embank
1352299148 2012-11-06 UrbanProduction Wells Violations Noted I inspected this unit as a follow-up to the inspection and subsequent issuance of a Compliance Notice issued on 03/30/2012. At that time, the owner was advised to make repairs to address non-compliance with the following items: The mechanical separator is 24 inches from the existing production tank. The rules mandate a separation distance of 10 feet. The tank battery dike is failing at the northwest corner where a seep is actively draining. There are several trash-bags filled with soil, located outside the tank battery fence that are now decaying and split open. The load-line valves located outside the dike and are not secured. These conditions which were extant on 03/30/2012 have not been addressed as of 11/06/2012. In addition, I noted that the ID sign for the unit is not readable. On 11/07/2012, I contacted the owners representative Tim Levengood of Industry Standard Supplies. He indicated that they were not aware that this issue had been established as a Compliance Notice, and had reportedly attempted to contact someone within the ODNR Oil and Gas Division to get clarification. We agreed to meet at the site on 11/14/2012 to review the compliance issues.
1352909881 2012-11-14 Preliminary Restoration No Violations Site meeting with Tim Levengood of Industry Standard Supplies regarding the need to address the items outlined in the current Compliance Notice. Tim agreed to address the following items: move the mechanical separator to the east side of the interior of the tank battery to comply with the spacing requirements of 1501:9-9-05(A)(5), repair and reinforce the secondary containment dike in the northwest corner, move the load-out valves to the interior of the battery, remove residual refuse in trash bags, fix the Unit ID, regrade the area on the north side of the dike where runoff is washing out the berm. He indicated that the repairs would be made within the next two weeks. I asked him to contact me when the issues had been adressed.
1371731696 2013-06-19 Production Wells No Violations The ID at the wellhead is still missing-so I called Tim Levengood and he indicated that it would be taken care of.
1428440000 2009-10-22 Preliminary Restoration No Violations Preliminary restoration was completed.
1446856314 2007-05-09 Drill / Deepen / Reopen No Violations drilling 3000
1608555594 2019-01-07 UrbanProduction Wells No Violations I conducted an inspection on this well. The well was equipped with a plunger lift assembly and in production, at the time of this inspection. The well was fenced and locked with legible identification. The tank battery was comprised of one 100 BBL tank, one 50 BBL tank and a mechanical separator. Valves on the separator were open. The diked tank battery was fenced with a locked door and legible identification. Lease access to the well and tank battery were stable.
1663688636 2007-06-04 Drill / Deepen / Reopen No Violations on site to reline and solidified the air pit
1774379580 2013-10-09 UrbanProduction Wells No Violations The producing unit consists of a wellhead and aboveground storage tank (AST) battery in separate board-on-board enclosures. The wellhead is a plunger lift unit and is producing. The battery is comprised of 1 140-barrel and 1 50-barrel steel tank and separator. Secondary containment, spacing, and signage is good. Process safety equipment (spark arrestor, carbon filter, and low-pressure relief valve) are present. Gates are locked. ID placard has been replaced. No problems noted. Impact relating to the release that occurred on 12/10/2010 has been effectively remedied.
1836951035 2012-03-30 UrbanProduction Wells Violations Noted My inspection of this well site found that the equipment spacing at the tank battery is not correct. The separator is approximately 3 from the production tank. The rules state a minimum of 10 should be maintained between these two pieces of equipment and the well owner was instructed to switch the brine tank and the production tank to meet spacing requirements. The soil of the tank battery floor is stained with crude oil, which must be removed and disposed of properly. There is a seep in the north west corner of the tank battery, where the sales line comes out of it. There is approximately one quart of free oil below the seep. There is water accumulating at the seep that has bacterial iron in it, causing red discoloring. I tested this water for chlorides and they were below drinking water standards. Oil soaked debris remains below the tank battery from a previous release from the tank battery. The well owner was instructed to clean up this debris and dispose of it properly. The valve at the south end of the load line has separated but the load line does have a second valve at the tank. The well owner has a thread protector screwed onto the south end of the load line but has been instructed to replace the valve. This valve needs to be located inside of the dike. The well owner was notified, by phone, during inspection of the needed clean up and repairs.
1888225489 2010-10-26 Production Wells No Violations ID was posted at the tank battery. NOV resolved.
707224876 2008-7-1 0:00:0 PW No Violations
903497580 2012-3-30 0:00: UP No Violations
998582587 2010-12-10 0:00 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0274460368 US-OH-122837 2007-06-12 Failure to comply with permit conditions
0438874232 US-OH-124725 2013-10-09 Well operation causing pollution and contamination
0804724432 US-OH-129137 2008-08-14 Failure to legibly identify well
0903497580 US-OH-130315 2015-03-27 Well operation causing pollution and contamination
0998582587 US-OH-131466 2013-10-09 Well operation causing pollution and contamination
1292413254 US-OH-108249 2010-12-15 Well operation causing pollution and contamination
1352299148 US-OH-110193 2015-02-05 Well operation causing pollution and contamination
1836951035 US-OH-118346 2012-04-02 Failure to meet mechanical seperator spacing requirements from oil tanks

For data sources see[9]

References