If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-085-21287 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.66,"lon":-81.23,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Lake | |
Municipality: Concord Township | |
Operator Name: ROCKEFELLER OIL COMPANY LLC | |
Well Pad ID: | |
Farm/Lease Name: BRADLEY | |
License Status: Producing | |
License Date: 2009-01-23 | |
Spud Date: 2009-02-15 | |
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC | |
Final Drill Date: 2009-02-22 | |
Well Total Depth: 3559.00 ft | |
Configuration: Vertical | |
Latitude: 41.660000 | |
Longitude: -81.230000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2009-01-23 | Proposed Formations:CLINTON, Issued Date:1/23/2009, Expired Date:1/23/2010 6:00:00 AM, Drilling unit acres:21.4, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2009-02-22 | |
Change of Owner | 2009-03-30 | Operator changed from 7909, JOHN D OIL & GAS COMPANY to 7447, GREAT PLAINS EXPLORATION LLC |
Completion Report Received | 2009-03-30 | |
Construction Permit Expires | 2010-01-23 | |
Change of Owner | 2016-12-05 | Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2009-06-11 | 3367 | 3396 | 28 |
3367 | 3396 | 28 | |
3367 | 3396 | 28 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 431 Bbl | 98500 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2009 | GREAT PLAINS EXPLORATION LLC | 15375.00 | 0.00 | 291 |
2010 | GREAT PLAINS EXPLORATION LLC | 6769.00 | 0.00 | 365 |
2011 | GREAT PLAINS EXPLORATION LLC | 5364.00 | 16.00 | 365 |
2012 | GREAT PLAINS EXPLORATION LLC | 6326.00 | 0.00 | 366 |
2013 | GREAT PLAINS EXPLORATION LLC | 4845.00 | 0.00 | 365 |
2014 | GREAT PLAINS EXPLORATION LLC | 3649.00 | 0.00 | 365 |
2015 | GREAT PLAINS EXPLORATION LLC | 3117.00 | 0.00 | 365 |
2016 | ROCKEFELLER OIL COMPANY LLC | 550.00 | 0.00 | 61 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2009 | GREAT PLAINS EXPLORATION LLC | Brine | 1060 | 291 |
2010 | GREAT PLAINS EXPLORATION LLC | Brine | 500 | 365 |
2011 | GREAT PLAINS EXPLORATION LLC | Brine | 560 | 365 |
2012 | GREAT PLAINS EXPLORATION LLC | Brine | 480 | 366 |
2013 | GREAT PLAINS EXPLORATION LLC | Brine | 160 | 365 |
2014 | GREAT PLAINS EXPLORATION LLC | Brine | 240 | 365 |
2015 | GREAT PLAINS EXPLORATION LLC | Brine | 80 | 365 |
2016 | GREAT PLAINS EXPLORATION LLC | Brine | 0 | 304 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1028385790 | 2018-2-13 0:00: | UP | No Violations | 0.50 |
-1939390673 | 2017-12-5 0:00: | UP | No Violations | |
-2005622329 | 2015-2-13 0:00: | UP | No Violations | 0.50 |
-478683344 | 2013-10-9 0:00: | UP | No Violations | |
-858838870 | 2018-4-17 0:00: | UP | No Violations | 1.00 |
-981003884 | 2009-10-26 0:00 | PL | No Violations | |
0478683344 | 2013-10-09 | UrbanProduction Wells | No Violations | The producing unit consists of a wellhead and aboveground storage tank (AST) battery in separate board-on-board enclosures. The wellhead is a mechanical plunger lift unit and is producing. The battery is comprised of 2 140-barrel steel tanks and separator. Secondary containment, spacing, and signage is good. Process safety equipment (spark arrestor, carbon filter, and low-pressure relief valve) are present. Gates are locked. No problems noted. |
0505625395 | 2012-12-05 | UrbanProduction Wells | No Violations | The unit is comprised of a two-tank battery (2 140-barrel production) and a wellhead with mechanical plunger lift, and mechanical separator, each in separate wood board-on-board enclosures. The well is currently in production. The tank and well spacing is in accordance with 1509:9-9-05 . Unit identification is present and legible at the tank battery. The tank battery secondary containment is adequate. I did not observe any leaks, spills, or other signs of contamination. The gates are locked. |
0711781427 | 2011-07-28 | UrbanProduction Wells | Violations Noted | Dike, ID, and spacing in compliance. Lease road is stable. Fencing in place, no locks on gates. Vent hatches installed and closed. Lighting arrestor and charcoal filter not installed. |
0858838870 | 2018-04-17 | UrbanProduction Wells | No Violations | inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked, and the 8.625-inch casing was not gauged nor fitted with a pressure relief device as required under the special permit conditions which were part of the drilling permit. At the time of this inspection, I observed the following: the were no locks at the load-line valves, and the surface casing nipple was not gauged or fitted with a pressure relief device. The ID signage remained from ownership and not accurate. I had previously contacted the company on several occasions since the issuance of the compliance notice regarding the deficiencies. The company had made pledges to remedy the deficiencies. |
0873314079 | 2016-02-09 | UrbanProduction Wells | Violations Noted | I inspected this well as part of routine inspection activity. The well and associated battery are located in an open portion of an otherwise wooded lot along Crile Rd. The well and battery are accessed via a short, unpaved road that enters from Crile Road. At the time of this inspection, I observed the following: a wellhead with mechanical plunger lift system in a board-on-board enclosure. Fittings and connections at the wellhead were secure. The 8.625-inch casing is valved at surface but not gauged. The battery is comprised of two 100-barrel steel production tanks and separator in a separate board-on-board enclosure. Enclosure gates were locked and secure. Hatches were closed and sealed. Secondary containment was present and intact. Fittings and connections were secure and free from signs of leakage or problems. I walked the areas surround both the well and battery and did not observe any signs of impact relative to the production activity. Signage was present. I noted the following safety issues: The load-line valves were not locked. The owner must remedy the following by 04/08/2016: secure the load-line valves with locks. Place and maintain a gauge at the surface casing nipple as required by permit condition. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection. |
0981003884 | 2009-10-26 | Preliminary Restoration | No Violations | Preliminary restoration meets all requirements. |
1028385790 | 2018-02-13 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked, and the 8.625-inch casing was not gauged nor fitted with a pressure relief device as required under the special permit conditions which were part of the drilling permit. At the time of this inspection, I observed the following: the were no locks at the load-line valves, and the surface casing nipple was not gauged or fitted with a pressure relief device. The ID signage remained from ownership and not accurate. I had previously contacted the company on several occasions since the issuance of the compliance notice regarding the deficiencies. The company had made pledges to remedy the deficiencies. |
1162669597 | 2017-04-10 | UrbanProduction Wells | No Violations | I inspected this producing well as a follow-up to a previously-issued Compliance Notice. At the time of the previous inspection, I had noted that the load-line valves were not secure with locks as required and the surface casing annulus was not gauged. At the time of this inspection, I observed the following: the access road to the well and battery, which is comprised of a gravel-paved road that enters from Crile Road and travels 700 feet to the well and battery, was in good condition with no drainage problems or wash-outs. The separate enclosure gates were locked and secure. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure and free from leakage. I walked the areas surrounding both the well and the battery and found no signs problems or impact to the surrounding in-situ features. I did observe the following maintenance and safety deficiencies; the load line valves remain unsecured, the ID signage had not been updated to reflect the recent change in ownership, and the wellhead enclosure has been partially dismantled, and the surface casing annulus is not gauged. I contacted John Magnussen with David Oil and advised him about the continuing deficiency. He indicated that the items are being worked on as they are able. I contacted Richard Osborne Sr. with David Oil Co., and as of the date of this report, I have not received a response. |
1344173238 | 2019-02-14 | UrbanProduction Wells | No Violations | I conducted an compliance notice follow-up inspection for compliance notice 873314079, regarding the load-line valves nneding locks installed and the 8.625-inch casing was not gauged nor fitted with a pressure relief device as required under the special permit conditions which were part of the drilling permit. At the time of this inspection, it was observed that the plunger lift assembly equipped well was not in production and the surface casing nipple was not gauged or fitted with a pressure relief device. The tank battery consisted of two 100 BBL tanks and a mechanical separator. The tank valves were still not equipped with locks and the identification still needed updated to reflect current owner information. Lease access to the site was stable with a gate at the entrance. |
1887523115 | 2017-09-25 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: missing locks on load-line valves and missing gauge on the surface casing as required as a special permit condition. At the time of this inspection, the noted deficiencies remained. In addition, the well signage remains unchanged since the change in ownership that occurred in 2016. Repeated calls to the owner have not produced any demonstrable action or results. |
1939390673 | 2017-12-05 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked, and the 8.625-inch casing was not gauged nor fitted with a pressure relief device as required under the special permit conditions which were part of the drilling permit. At the time of this inspection, I observed the following: the ere no locks at the load-line valves, and the surface casing nipple was not gauged or fitted with a pressure relief device. In addition, the ID signage has not been updated to reflect the change of ownership that occurred over 12 months prior to this inspection. I have contacted the company on several occasions since the issuance of the compliance notice. The company has reported that problems with personnel and/or lack of funds, have prevented them from being in compliance. |
2005622329 | 2015-02-13 | UrbanProduction Wells | No Violations | I inspected this producing unit as part of routine inspection activity. The well is located in a commercial/light industrial area on the north side of Crile Rd. The well is comprised of a wellhead with mechanical plunger lift located 200 feet from the tank battery. The battery, mechanical separator, and battery are in separate board-on-board enclosures. The enclosure for the battery is unlocked and I found the gate to be left open. Load outs at the battery are bull-plugged. Connections and fittings are secure and free from signs of leakage or problems. At the time of this inspection, there are 10 to 15 inches of snowfall, which hinders a thorough inspection of surficial features (e.g. access road, secondary containment interior. I notified Tim Reilly (John D. Oil & Gas) about the need for a lock on the gate. I will follow-up in 30 days. |
505625395 | 2012-12-5 0:00: | UP | No Violations | |
711781427 | 2011-7-28 0:00: | UP | No Violations | |
873314079 | 2016-2-9 0:00:0 | UP | No Violations | 0.50 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0711781427 | US-OH-128066 | 2011-08-01 | LOCKS | |
0711781427 | US-OH-128067 | 2011-08-01 | General Safety | |
0873314079 | US-OH-129942 | 2016-04-27 | LOCKS | |
0873314079 | US-OH-129943 | 2016-04-27 | General Safety |