Well ID: 34-005-21121 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.8,"lon":-82.36,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Ashland | |
Municipality: Mifflin Township | |
Operator Name: COLUMBIA GAS TRANSMISSION LLC | |
Well Pad ID: | |
Farm/Lease Name: MARKLEY EARL F | |
License Status: Storage Well | |
License Date: | |
Spud Date: 1954-11-05 | |
Spud Drilling Contractor: | |
Final Drill Date: 1954-12-13 | |
Well Total Depth: 2665.00 ft | |
Configuration: Vertical | |
Latitude: 40.800000 | |
Longitude: -82.360000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1954-11-05 | |
Completed | 1954-12-13 | |
Reached Total Depth | 1954-12-13 | |
Record Last Modified | 2013-05-23 |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2014-08-04 | H2O | 0 | 11274 Gal | 26900 | Universal Well Services Inc. | The job was a nitrogen assisted fracture stimulation. 43,750 cubic ft of nitrogen gas was used. The liquid was a cross linked fresh water gel. This was a refracture and cleanout of the well and there was no observed break of the formation. Injection test pressure was 1748 psi at 18 barrels per minute. 250 gallons of hydrochloric acid was pumped ahead of the sand. |
For data sources see[3]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1275482662 | 2020-4-22 0:00: | SO | No Violations | |
-132336051 | 2014-8-4 0:00:0 | SO | No Violations | 5.00 |
-1820956778 | 2016-5-25 0:00: | SO | No Violations | 0.50 |
-1856753647 | 2015-7-24 0:00: | SO | No Violations | 0.50 |
-972431943 | 2019-3-7 0:00:0 | SO | No Violations | |
0132336051 | 2014-08-04 | Storage Well | No Violations | The operator is conducting a fracture stimulation on the well. See the report for details. |
0477464142 | 2017-04-24 | Storage Well | No Violations | ID is posted and the location is maintained. The gate valve is open; the annulus is shut in. There is a house gas meter at the well. The well is not equipped with a separator. |
0972431943 | 2019-03-07 | Storage Well | No Violations | Performed annual inspection for Columbia Gas Storage Well #9422 on 03/07/2019. The well is equipped with a flanged wellhead with 1-master valve and 1-wing valve, and 1-meter with 2-regulators. Well identification is clearly displayed. The well is located ~120 from its RBDMS location. A map showing the location discrepancy, as well as a request for the location to be updated in RBDMS was sent to Aaron Lantz (DOGRM Columbus). No other problems were noted at the time of the inspection. |
1172848227 | 2013-11-06 | Storage Well | No Violations | The well and location are in compliance. |
1524162904 | 2018-04-19 | Storage Well | No Violations | ID is posted and the location is maintained. The annulus is shut in. There is a house gas connection at the pipeline tie in. |
1820956778 | 2016-05-25 | Storage Well | No Violations | ID is posted and the location is maintained. There is no separator at the well. The annulus is shut in. |
1856753647 | 2015-07-24 | Storage Well | No Violations | ID is posted. The location is maintained. Backside valves are closed and have pipe plugs in them. |
477464142 | 2017-4-24 0:00: | SO | No Violations | 0.50 |
For data sources see[4]