X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-111-23743

Well Details

Well ID: 34-111-23743
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Salem Township
Operator Name: GENESIS RESOURCES LLC
Well Pad ID:
Farm/Lease Name: WEFLER
License Status: Producing
License Date: 2000-01-27
Spud Date: 1999-10-08
Spud Drilling Contractor: WARREN DRLG
Final Drill Date: 1999-10-14
Well Total Depth: 6636.00 ft
Configuration: Vertical
Latitude: 39.730000
Longitude: -80.900000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 1999-09-16 Proposed Formations:BEREA/GORDON/DEV. SHALE/ORISKANY, Issued Date:9/16/99, Expired Date:9/15/2000 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:EDPW
APP 2000-01-27 Proposed Formations:GORDON, Issued Date:1/27/00, Expired Date:1/26/01 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Change of Owner 2006-02-03 Operator changed from 2789, SMELTZER BENJAMIN CO to 1634, NORTHWOOD ENERGY CORP

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-04-12 6472 6470 32
2000-04-12 2980 2985 21
2980 2985 21
6472 6470 32
2980 2985 21

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 45000 Gal 7500 500 GALLONS HCL ACID….COULD NOT TREAT ORISKANY DUE TO HOLE IN CASING

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2005 NORTHWOOD ENERGY CORP 0.00 0.00 0
2006 NORTHWOOD ENERGY CORP 17.00 0.00 365
2007 NORTHWOOD ENERGY CORP 0.00 0.00 0
2008 NORTHWOOD ENERGY CORP 14.00 0.00 365
2009 NORTHWOOD ENERGY CORP 363.00 0.00 365
2010 NORTHWOOD ENERGY CORP 718.00 0.00 365
2011 NORTHWOOD ENERGY CORP 192.00 0.00 0
2012 NORTHWOOD ENERGY CORP 271.00 0.00 366
2013 NORTHWOOD ENERGY CORP 198.00 0.00 365
2014 NORTHWOOD ENERGY CORP 211.00 0.00 365
2015 NORTHWOOD ENERGY CORP 90.00 0.00 365
2016 NORTHWOOD ENERGY CORP 211.00 0.00 365
2017 NORTHWOOD ENERGY CORP 142.00 0.00 365
2018 NORTHWOOD ENERGY CORP 280.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2005 NORTHWOOD ENERGY CORP Brine 0 0
2006 NORTHWOOD ENERGY CORP Brine 0 365
2007 NORTHWOOD ENERGY CORP Brine 0 0
2008 NORTHWOOD ENERGY CORP Brine 0 365
2009 NORTHWOOD ENERGY CORP Brine 0 365
2010 NORTHWOOD ENERGY CORP Brine 0 365
2011 NORTHWOOD ENERGY CORP Brine 52
2012 NORTHWOOD ENERGY CORP Brine 0 366
2013 NORTHWOOD ENERGY CORP Brine 0 365
2014 NORTHWOOD ENERGY CORP Brine 0 365
2015 NORTHWOOD ENERGY CORP Brine 0 365
2016 NORTHWOOD ENERGY CORP Brine 63 365
2017 NORTHWOOD ENERGY CORP Brine 0 365
2018 NORTHWOOD ENERGY CORP Brine 14 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-516771897 2019-4-18 0:00: PW No Violations 0.20
0011577020 2002-09-24 Production Wells No Violations
0516771897 2019-04-18 Production Wells No Violations On this day, I found the well equipped with 4.5 inch diameter casing with the production valve closed, and 2.375 inch diameter upset tubing with the production valve open. It is setup to be produced by means of a pumping unit with rods and a gas engine. The production facility consists of (1) 100 barrel steel tank, drip tank, vertical separator, and an orifice sales meter with a current chart all contained within an earthen dike. The production records are current and the tank is properly identified.
11577020 2002-9-24 0:00: PW No Violations
1445978740 2015-10-27 Preliminary Restoration No Violations Preliminary Restoration status check inspection found the following equipment present at the well head 4.5 production casing 2.375 tubing and pumping rods with the production valves in the open position. At the production fluid storage are a single 100 barrel production tank is present along with a mechanical separator and gas sales meter with a current 31 day sales chart present.
1585848198 2020-4-2 0:00:0 PW No Violations 0.40
1879882637 2007-03-15 Preliminary Restoration No Violations Restoration work at site satisfactory, well is equipped with pump jack and tubing and rods and 1-100 bbl tank in need of prper dike construction around it.

For data sources see[9]

References